Skip to main content
Top
Published in: Journal of Digital Imaging 6/2018

01-12-2018

Three-Dimensional Surface Point Cloud Ultrasound for Better Understanding and Transmission of Ultrasound Scan Information

Author: Joseph Nathaniel Stember

Published in: Journal of Imaging Informatics in Medicine | Issue 6/2018

Login to get access

Abstract

Ultrasound is notoriously plagued by high user dependence. There is a steep drop-off in information in going from what the sonographer sees during image acquisition and what the interpreting radiologist is able to view at the reading station. One countermeasure is probe localization and tracking. Current implementations are too difficult and expensive to use and/or do not provide adequate detail and perspective. The aim of this work was to demonstrate that a protocol combining surface three-dimensional photographic imaging with traditional ultrasound images may be a solution to the problem of probe localization, this approach being termed surface point cloud ultrasound (SPC-US). Ultrasound images were obtained of major vessels in an ultrasound training phantom, while simultaneously obtaining surface point cloud (SPC) 3D photographic images, with additional scanning performed on the right forearm soft tissues, kidneys, chest, and pelvis. The resulting sets of grayscale/color Doppler ultrasound and SPC images are juxtaposed and displayed for interpretation in a manner analogous to current text-based annotation or computer-generated stick figure probe position illustrations. Clearly demonstrated is that SPC-US better communicates information of probe position and orientation. Overall, it is shown that SPC-US provides much richer image representations of probe position on the patients than the current prevailing schemes. SPC-US turns out to be a rather general technique with many anticipated future applications, though only a few sample applications are illustrated in the present work.
Literature
1.
go back to reference Harris-Love MO, Ismail C, Monfaredi R, Hernandez HJ, Pennington D, Woletz P et al.: Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience. PeerJ. 4:e2146, 2016CrossRef Harris-Love MO, Ismail C, Monfaredi R, Hernandez HJ, Pennington D, Woletz P et al.: Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience. PeerJ. 4:e2146, 2016CrossRef
2.
go back to reference Dhyani M, Roll SC, Gilbertson MW, Orlowski M, Anvari A, Li Q et al.: A pilot study to precisely quantify forces applied by sonographers while scanning: a step toward reducing ergonomic injury. Work. 58(2):241–247, 2017CrossRef Dhyani M, Roll SC, Gilbertson MW, Orlowski M, Anvari A, Li Q et al.: A pilot study to precisely quantify forces applied by sonographers while scanning: a step toward reducing ergonomic injury. Work. 58(2):241–247, 2017CrossRef
3.
go back to reference Gilbertson MW, Anthony BW: An ergonomic, instrumented ultrasound probe for 6-axis force/torque measurement. Conf Proc IEEE Eng Med Biol Soc. 2013:140–143, 2013PubMed Gilbertson MW, Anthony BW: An ergonomic, instrumented ultrasound probe for 6-axis force/torque measurement. Conf Proc IEEE Eng Med Biol Soc. 2013:140–143, 2013PubMed
4.
go back to reference Du X, Anthony B: Controlled angular and radial scanning for super resolution concentric circular imaging. Opt Express. 24(20):22581–22595, 2016CrossRef Du X, Anthony B: Controlled angular and radial scanning for super resolution concentric circular imaging. Opt Express. 24(20):22581–22595, 2016CrossRef
5.
go back to reference Sun SY, Gilbertson M, Anthony BW: Probe localization for freehand 3D ultrasound by tracking skin features. Med Image Comput Comput Assist Interv. 17(Pt 2):365–372, 2014PubMed Sun SY, Gilbertson M, Anthony BW: Probe localization for freehand 3D ultrasound by tracking skin features. Med Image Comput Comput Assist Interv. 17(Pt 2):365–372, 2014PubMed
6.
go back to reference Xiang Z, Fincke J, Kuzmin A, Lempitsky V, Anthony B: A single element 3D ultrasound tomography system. Conf Proc IEEE Eng Med Biol Soc. 2015:5541–5544, 2015 Xiang Z, Fincke J, Kuzmin A, Lempitsky V, Anthony B: A single element 3D ultrasound tomography system. Conf Proc IEEE Eng Med Biol Soc. 2015:5541–5544, 2015
7.
go back to reference Beller S, Hunerbein M, Eulenstein S, Lange T, Schlag PM: Feasibility of navigated resection of liver tumors using multiplanar visualization of intraoperative 3-dimensional ultrasound data. Ann Surg. 246(2):288–294, 2007CrossRef Beller S, Hunerbein M, Eulenstein S, Lange T, Schlag PM: Feasibility of navigated resection of liver tumors using multiplanar visualization of intraoperative 3-dimensional ultrasound data. Ann Surg. 246(2):288–294, 2007CrossRef
8.
go back to reference Kucukkaya F, Aribal E, Tureli D, Altas H, Kaya H: Use of a volume navigation technique for combining real-time ultrasound and contrast-enhanced MRI: accuracy and feasibility of a novel technique for locating breast lesions. AJR Am J Roentgenol. 206(1):217–225, 2016CrossRef Kucukkaya F, Aribal E, Tureli D, Altas H, Kaya H: Use of a volume navigation technique for combining real-time ultrasound and contrast-enhanced MRI: accuracy and feasibility of a novel technique for locating breast lesions. AJR Am J Roentgenol. 206(1):217–225, 2016CrossRef
9.
go back to reference Muns A, Meixensberger J, Arnold S, Schmitgen A, Arlt F, Chalopin C et al.: Integration of a 3D ultrasound probe into neuronavigation. Acta Neurochir (Wien). 153(7):1529–1533, 2011CrossRef Muns A, Meixensberger J, Arnold S, Schmitgen A, Arlt F, Chalopin C et al.: Integration of a 3D ultrasound probe into neuronavigation. Acta Neurochir (Wien). 153(7):1529–1533, 2011CrossRef
10.
go back to reference Putzer D, Arco D, Schamberger B, Schanda F, Mahlknecht J, Widmann G et al.: Comparison of two electromagnetic navigation systems for CT-guided punctures: a phantom study. Rofo. 188(5):470–478, 2016CrossRef Putzer D, Arco D, Schamberger B, Schanda F, Mahlknecht J, Widmann G et al.: Comparison of two electromagnetic navigation systems for CT-guided punctures: a phantom study. Rofo. 188(5):470–478, 2016CrossRef
11.
go back to reference Joh JH, Han SA, Kim SH, Park HC: Ultrasound fusion imaging with real-time navigation for the surveillance after endovascular aortic aneurysm repair. Ann Surg Treat Res. 92(6):436–439, 2017CrossRef Joh JH, Han SA, Kim SH, Park HC: Ultrasound fusion imaging with real-time navigation for the surveillance after endovascular aortic aneurysm repair. Ann Surg Treat Res. 92(6):436–439, 2017CrossRef
12.
go back to reference Ma L, Nakamae K, Wang J, Kiyomatsu H, Tsukihara H, Kobayashi E et al.: Image-guided laparoscopic pelvic lymph node dissection using stereo visual tracking free-hand laparoscopic ultrasound. Conf Proc IEEE Eng Med Biol Soc. 2017:3240–3243, 2017PubMed Ma L, Nakamae K, Wang J, Kiyomatsu H, Tsukihara H, Kobayashi E et al.: Image-guided laparoscopic pelvic lymph node dissection using stereo visual tracking free-hand laparoscopic ultrasound. Conf Proc IEEE Eng Med Biol Soc. 2017:3240–3243, 2017PubMed
13.
go back to reference Ungi T, Moult E, Schwab JH, Fichtinger G: Tracked ultrasound snapshots in percutaneous pedicle screw placement navigation: a feasibility study. Clin Orthop Relat Res. 471(12):4047–4055, 2013CrossRef Ungi T, Moult E, Schwab JH, Fichtinger G: Tracked ultrasound snapshots in percutaneous pedicle screw placement navigation: a feasibility study. Clin Orthop Relat Res. 471(12):4047–4055, 2013CrossRef
14.
go back to reference Takamoto T, Mise Y, Satou S, Kobayashi Y, Miura K, Saiura A et al.: Feasibility of intraoperative navigation for liver resection using real-time virtual sonography with novel automatic registration system. World J Surg., 2017 Takamoto T, Mise Y, Satou S, Kobayashi Y, Miura K, Saiura A et al.: Feasibility of intraoperative navigation for liver resection using real-time virtual sonography with novel automatic registration system. World J Surg., 2017
15.
go back to reference Doba N, Fukuda H, Numata K, Hao Y, Hara K, Nozaki A et al.: A new device for fiducial registration of image-guided navigation system for liver RFA. Int J Comput Assist Radiol Surg., 2017 Doba N, Fukuda H, Numata K, Hao Y, Hara K, Nozaki A et al.: A new device for fiducial registration of image-guided navigation system for liver RFA. Int J Comput Assist Radiol Surg., 2017
16.
go back to reference Marin JR, Lewiss RE, American Academy of Pediatrics CoPEM, Society for Academic Emergency Medicine AoEU, American College of Emergency Physicians PEMC, World Interactive Network Focused on Critical U: Point-of-care ultrasonography by pediatric emergency medicine physicians. Pediatrics. 135(4):e1113–e1122, 2015CrossRef Marin JR, Lewiss RE, American Academy of Pediatrics CoPEM, Society for Academic Emergency Medicine AoEU, American College of Emergency Physicians PEMC, World Interactive Network Focused on Critical U: Point-of-care ultrasonography by pediatric emergency medicine physicians. Pediatrics. 135(4):e1113–e1122, 2015CrossRef
17.
go back to reference Chung E, Marchetti MA, Scope A, Dusza SW, Fonseca M, DaSilva D et al.: Towards three-dimensional temporal monitoring of naevi: a comparison of methodologies for assessing longitudinal changes in skin surface area around naevi. Br J Dermatol. 175(6):1376–1378, 2016CrossRef Chung E, Marchetti MA, Scope A, Dusza SW, Fonseca M, DaSilva D et al.: Towards three-dimensional temporal monitoring of naevi: a comparison of methodologies for assessing longitudinal changes in skin surface area around naevi. Br J Dermatol. 175(6):1376–1378, 2016CrossRef
18.
go back to reference Margolin EJ, Mlynarczyk CM, Mulhall JP, Stember DS, Stahl PJ: Three-dimensional photography for quantitative assessment of penile volume-loss deformities in Peyronie’s disease. J Sex Med. 14(6):829–833, 2017CrossRef Margolin EJ, Mlynarczyk CM, Mulhall JP, Stember DS, Stahl PJ: Three-dimensional photography for quantitative assessment of penile volume-loss deformities in Peyronie’s disease. J Sex Med. 14(6):829–833, 2017CrossRef
19.
go back to reference Halula SE, Leino DG, Patel MN, Racadio JM, Lungren MP: Isolated upper extremity posttransplant lymphoproliferative disorder in a child. Case Rep Radiol. 2015:813989, 2015PubMedPubMedCentral Halula SE, Leino DG, Patel MN, Racadio JM, Lungren MP: Isolated upper extremity posttransplant lymphoproliferative disorder in a child. Case Rep Radiol. 2015:813989, 2015PubMedPubMedCentral
20.
go back to reference Hansen KL, Nielsen MB, Ewertsen C: Ultrasonography of the kidney: a pictorial review. Diagnostics (Basel). 6(1), 2015CrossRef Hansen KL, Nielsen MB, Ewertsen C: Ultrasonography of the kidney: a pictorial review. Diagnostics (Basel). 6(1), 2015CrossRef
Metadata
Title
Three-Dimensional Surface Point Cloud Ultrasound for Better Understanding and Transmission of Ultrasound Scan Information
Author
Joseph Nathaniel Stember
Publication date
01-12-2018
Publisher
Springer International Publishing
Published in
Journal of Imaging Informatics in Medicine / Issue 6/2018
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-017-0046-7

Other articles of this Issue 6/2018

Journal of Digital Imaging 6/2018 Go to the issue