Skip to main content
Top
Published in: Journal of Digital Imaging 1/2017

01-02-2017

Digitizing an Analog Radiography Teaching File Under Time Constraint: Trade-Offs in Efficiency and Image Quality

Authors: Thomas W. Loehfelm, Adam B. Prater, Tequam Debebe, Aarti K. Sekhar

Published in: Journal of Imaging Informatics in Medicine | Issue 1/2017

Login to get access

Abstract

We digitized the radiography teaching file at Black Lion Hospital (Addis Ababa, Ethiopia) during a recent trip, using a standard digital camera and a fluorescent light box. Our goal was to photograph every radiograph in the existing library while optimizing the final image size to the maximum resolution of a high quality tablet computer, preserving the contrast resolution of the radiographs, and minimizing total library file size. A secondary important goal was to minimize the cost and time required to take and process the images. Three workers were able to efficiently remove the radiographs from their storage folders, hang them on the light box, operate the camera, catalog the image, and repack the radiographs back to the storage folder. Zoom, focal length, and film speed were fixed, while aperture and shutter speed were manually adjusted for each image, allowing for efficiency and flexibility in image acquisition. Keeping zoom and focal length fixed, which kept the view box at the same relative position in all of the images acquired during a single photography session, allowed unused space to be batch-cropped, saving considerable time in post-processing, at the expense of final image resolution. We present an analysis of the trade-offs in workflow efficiency and final image quality, and demonstrate that a few people with minimal equipment can efficiently digitize a teaching file library.
Literature
1.
go back to reference Yang G, Lim C: Creating teaching files. Biomed Imaging Intervention J 2(4), e53, 2006CrossRef Yang G, Lim C: Creating teaching files. Biomed Imaging Intervention J 2(4), e53, 2006CrossRef
2.
go back to reference Scarsbrook AF, Foley PT, Perriss RW, Graham RN: Radiological digital teaching file development: an overview. Clin Radiol 60(8):831–837, 2005CrossRefPubMed Scarsbrook AF, Foley PT, Perriss RW, Graham RN: Radiological digital teaching file development: an overview. Clin Radiol 60(8):831–837, 2005CrossRefPubMed
3.
4.
go back to reference Cone SW, Carucci LR, Yu J, Rafiq A, Doarn CR, Merrell RC: Acquisition and evaluation of radiography images by digital camera. Telemed J e-Health Off J Am Telemed Assoc 11(2):130–136, 2005CrossRef Cone SW, Carucci LR, Yu J, Rafiq A, Doarn CR, Merrell RC: Acquisition and evaluation of radiography images by digital camera. Telemed J e-Health Off J Am Telemed Assoc 11(2):130–136, 2005CrossRef
5.
go back to reference Brault B, Hoskinson J, Armbrust L, Milliken G: Comparison of seven digital cameras for digitizing radiographs. Vet Radiol Ultrasound 45(4):298–304, 2004CrossRefPubMed Brault B, Hoskinson J, Armbrust L, Milliken G: Comparison of seven digital cameras for digitizing radiographs. Vet Radiol Ultrasound 45(4):298–304, 2004CrossRefPubMed
6.
go back to reference Peretz B, Kaffe I, Amir E: Digital images obtained with a digital camera are not associated with a loss of critical information - preliminary study. Brit Dent J 206(5):E9, 2009CrossRefPubMed Peretz B, Kaffe I, Amir E: Digital images obtained with a digital camera are not associated with a loss of critical information - preliminary study. Brit Dent J 206(5):E9, 2009CrossRefPubMed
7.
go back to reference Salazar AJ, Camacho JC, Aguirre DA: Comparison between differently priced devices for digital capture of X-ray films using computed tomography as a gold standard: a multireader-multicase receiver operating characteristic curve study. Telemed J e-Health Off J Am Telemed Assoc 17(4):275–282, 2011CrossRef Salazar AJ, Camacho JC, Aguirre DA: Comparison between differently priced devices for digital capture of X-ray films using computed tomography as a gold standard: a multireader-multicase receiver operating characteristic curve study. Telemed J e-Health Off J Am Telemed Assoc 17(4):275–282, 2011CrossRef
8.
go back to reference Licurse MY, Kim SH, Kim W, Ruutiainen AT, Cook TS: Comparison of diagnostic accuracy of plain film radiographs between original film and smartphone capture: a pilot study. J Digit Imaging 28(6):646–653, 2015CrossRefPubMedPubMedCentral Licurse MY, Kim SH, Kim W, Ruutiainen AT, Cook TS: Comparison of diagnostic accuracy of plain film radiographs between original film and smartphone capture: a pilot study. J Digit Imaging 28(6):646–653, 2015CrossRefPubMedPubMedCentral
Metadata
Title
Digitizing an Analog Radiography Teaching File Under Time Constraint: Trade-Offs in Efficiency and Image Quality
Authors
Thomas W. Loehfelm
Adam B. Prater
Tequam Debebe
Aarti K. Sekhar
Publication date
01-02-2017
Publisher
Springer International Publishing
Published in
Journal of Imaging Informatics in Medicine / Issue 1/2017
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-016-9906-9

Other articles of this Issue 1/2017

Journal of Digital Imaging 1/2017 Go to the issue