Skip to main content
Top
Published in: Journal of Digital Imaging 2/2014

01-04-2014

Design and Validation of Automated Femoral Bone Morphology Measurements in Cerebral Palsy

Authors: Noyeol Park, Jehee Lee, Ki Hyuk Sung, Moon Seok Park, Seungbum Koo

Published in: Journal of Imaging Informatics in Medicine | Issue 2/2014

Login to get access

Abstract

Accurate quantification of bone morphology is important for monitoring the progress of bony deformation in patients with cerebral palsy. The purpose of the study was to develop an automatic bone morphology measurement method using one or two radiographs. The study focused on four morphologic measurements—neck-shaft angle, femoral anteversion, shaft bowing angle, and neck length. Fifty-four three-dimensional (3D) geometrical femur models were generated from the computed tomography (CT) of cerebral palsy patients. Principal component analysis was performed on the combined data of geometrical femur models and manual measurements of the four morphologic measurements to generate a statistical femur model. The 3D–2D registration of the statistical femur model for radiography computes four morphological measurements of the femur in the radiographs automatically. The prediction performance was tested here by means of leave-one-out cross-validation and was quantified by the intraclass correlation coefficient (ICC) and by measuring the absolute differences between automatic prediction from two radiographs and manual measurements using original CT images. For the neck-shaft angle, femoral anteversion, shaft bowing angle, and neck length, the ICCs were 0.812, 0.960, 0.834, and 0.750, respectively, and the mean absolute differences were 2.52°, 2.85°, 0.92°, and 1.88 mm, respectively. Four important dimensions of the femur could be predicted from two views with very good agreement with manual measurements from CT and hip radiographs. The proposed method can help young patients avoid instances of large radiation exposure from CT, and their femoral deformities can be quantified robustly and effectively from one or two radiograph(s).
Literature
1.
go back to reference Bax M, Goldstein M, Rosenbaum P, Leviton A, Paneth N, Dan B, Jacobsson B, Damiano D: Proposed definition and classification of cerebral palsy. Dev Med Child Neurol 47(8):571–576, 2005PubMedCrossRef Bax M, Goldstein M, Rosenbaum P, Leviton A, Paneth N, Dan B, Jacobsson B, Damiano D: Proposed definition and classification of cerebral palsy. Dev Med Child Neurol 47(8):571–576, 2005PubMedCrossRef
2.
go back to reference Bobroff ED, Chambers HG, Sartoris DJ, Wyatt MP, Sutherland DH: Femoral anteversion and neck-shaft angle in children with cerebral palsy. Clin Orthop Relat Res 364:194–204, 1999PubMedCrossRef Bobroff ED, Chambers HG, Sartoris DJ, Wyatt MP, Sutherland DH: Femoral anteversion and neck-shaft angle in children with cerebral palsy. Clin Orthop Relat Res 364:194–204, 1999PubMedCrossRef
3.
go back to reference Crane L: Femoral torsion and its relation to toeing-in and toeing-out. J Bone Joint Surg Am 41-A(3):421–428, 1959PubMed Crane L: Femoral torsion and its relation to toeing-in and toeing-out. J Bone Joint Surg Am 41-A(3):421–428, 1959PubMed
4.
go back to reference Laplaza FJ, Root L, Tassanawipas A, Glasser DB: Femoral torsion and neck-shaft angles in cerebral palsy. J Pediatr Orthop 13(2):192–199, 1993PubMed Laplaza FJ, Root L, Tassanawipas A, Glasser DB: Femoral torsion and neck-shaft angles in cerebral palsy. J Pediatr Orthop 13(2):192–199, 1993PubMed
5.
go back to reference Laplaza FJ, Root L: Femoral anteversion and neck-shaft angles in hip instability in cerebral palsy. J Pediatr Orthop 6:719–723, 1994CrossRef Laplaza FJ, Root L: Femoral anteversion and neck-shaft angles in hip instability in cerebral palsy. J Pediatr Orthop 6:719–723, 1994CrossRef
6.
go back to reference O’Sullivan R, Walsh M, Hewart P, Jenkinson A, Ross LA, O’Brien T: Factors associated with internal hip rotation gait in patients with cerebral palsy. J Pediatr Orthop 26(4):537–541, 2006PubMedCrossRef O’Sullivan R, Walsh M, Hewart P, Jenkinson A, Ross LA, O’Brien T: Factors associated with internal hip rotation gait in patients with cerebral palsy. J Pediatr Orthop 26(4):537–541, 2006PubMedCrossRef
7.
go back to reference Robin J, Graham H, Selber P, Dobson F, Smith K, Baker R: Proximal femoral geometry in cerebral palsy: a population-based cross-sectional study. J Bone Joint Surg Br 90(10):1372–1379, 2008PubMedCrossRef Robin J, Graham H, Selber P, Dobson F, Smith K, Baker R: Proximal femoral geometry in cerebral palsy: a population-based cross-sectional study. J Bone Joint Surg Br 90(10):1372–1379, 2008PubMedCrossRef
8.
go back to reference Abel MF, Sutherland DH, Wenger DR, Mubarak SJ: Evaluation of CT scans and 3-D reformatted images for quantitative assessment of the hip. J Pediatr Orthop 14(1):48–53, 1994PubMedCrossRef Abel MF, Sutherland DH, Wenger DR, Mubarak SJ: Evaluation of CT scans and 3-D reformatted images for quantitative assessment of the hip. J Pediatr Orthop 14(1):48–53, 1994PubMedCrossRef
9.
go back to reference Abel MF, Wenger DR, Mubarak SJ, Sutherland DH: Quantitative analysis of hip dysplasia in cerebral palsy: a study of radiographs and 3-D reformatted images. J Pediatr Orthop 14(3):283–289, 1994PubMedCrossRef Abel MF, Wenger DR, Mubarak SJ, Sutherland DH: Quantitative analysis of hip dysplasia in cerebral palsy: a study of radiographs and 3-D reformatted images. J Pediatr Orthop 14(3):283–289, 1994PubMedCrossRef
10.
go back to reference Mubarak SJ, Valencia FG, Wenger DR: One-stage correction of the spastic dislocated hip. Use of pericapsular acetabuloplasty to improve coverage. J Bone Joint Surg Am 74(9):1347–1357, 1992PubMed Mubarak SJ, Valencia FG, Wenger DR: One-stage correction of the spastic dislocated hip. Use of pericapsular acetabuloplasty to improve coverage. J Bone Joint Surg Am 74(9):1347–1357, 1992PubMed
11.
go back to reference Sugano N, Noble PC, Kamaric E: A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr 22(4):610–614, 1998PubMedCrossRef Sugano N, Noble PC, Kamaric E: A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr 22(4):610–614, 1998PubMedCrossRef
12.
go back to reference Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN: Radiation exposure from musculoskeletal computerized tomographic scans. J Bone Joint Surg Am 91(8):1882–1889, 2009PubMedCrossRef Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN: Radiation exposure from musculoskeletal computerized tomographic scans. J Bone Joint Surg Am 91(8):1882–1889, 2009PubMedCrossRef
13.
go back to reference Davids JR, Marshall AD, Blocker ER, Frick SL, Blackhurst DW, Skewes E: Femoral anteversion in children with cerebral palsy. Assessment with two and three-dimensional computed tomography scans. J Bone Joint Surg Am 85(3):481–488, 2003PubMed Davids JR, Marshall AD, Blocker ER, Frick SL, Blackhurst DW, Skewes E: Femoral anteversion in children with cerebral palsy. Assessment with two and three-dimensional computed tomography scans. J Bone Joint Surg Am 85(3):481–488, 2003PubMed
14.
go back to reference Chung CY, Lee KM, Park MS, Lee SH, Choi IH, Cho TJ: Validity and reliability of measuring femoral anteversion and neck-shaft angle in patients with cerebral palsy. J Bone Joint Surg Am 92(5):1195–1205, 2010PubMedCrossRef Chung CY, Lee KM, Park MS, Lee SH, Choi IH, Cho TJ: Validity and reliability of measuring femoral anteversion and neck-shaft angle in patients with cerebral palsy. J Bone Joint Surg Am 92(5):1195–1205, 2010PubMedCrossRef
15.
go back to reference Zheng G, Ballester MA, Styner M, Nolte LP: Reconstruction of patient-specific 3D bone surface from 2D calibrated fluoroscopic images and point distribution model. In: Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention. MICCAI’06; Copenhagen, Denmark. Berlin: Springer, 2006 Zheng G, Ballester MA, Styner M, Nolte LP: Reconstruction of patient-specific 3D bone surface from 2D calibrated fluoroscopic images and point distribution model. In: Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention. MICCAI’06; Copenhagen, Denmark. Berlin: Springer, 2006
16.
go back to reference Ferrarini L, Olofsen H, Palm WM, van Buchem MA, Reiber JHC, Admiraal-Behloul F: GAMES: growing and adaptive meshes for fully automatic shape modeling and analysis. Med Image Anal 11(3):302–314, 2007PubMedCrossRef Ferrarini L, Olofsen H, Palm WM, van Buchem MA, Reiber JHC, Admiraal-Behloul F: GAMES: growing and adaptive meshes for fully automatic shape modeling and analysis. Med Image Anal 11(3):302–314, 2007PubMedCrossRef
17.
go back to reference Bookstein F: Morphometric tools for landmark data: geometry and biology. Cambridge: Cambridge University Press, 1997 Bookstein F: Morphometric tools for landmark data: geometry and biology. Cambridge: Cambridge University Press, 1997
18.
go back to reference Cootes T, Taylor C, Cooper DH, Graham J: Training models of shape from sets of examples. In: Proceedings of the British Machine Vision Conference. Berlin: Springer, 1992 Cootes T, Taylor C, Cooper DH, Graham J: Training models of shape from sets of examples. In: Proceedings of the British Machine Vision Conference. Berlin: Springer, 1992
19.
go back to reference Kendall DG: A survey of the statistical theory of shape. Statist. Sci. 4(2):87–99 Kendall DG: A survey of the statistical theory of shape. Statist. Sci. 4(2):87–99
20.
go back to reference Park MS, Kim SJ, Chung CY, Choi IH, Lee SH, Lee KM: Statistical consideration for bilateral cases in orthopaedic research. J Bone Joint Surg Am 92(8):1732–1737, 2010PubMedCrossRef Park MS, Kim SJ, Chung CY, Choi IH, Lee SH, Lee KM: Statistical consideration for bilateral cases in orthopaedic research. J Bone Joint Surg Am 92(8):1732–1737, 2010PubMedCrossRef
21.
go back to reference Fleiss JL: Statistical methods for rates and proportions, 2nd edition. Wiley, New York, 1981 Fleiss JL: Statistical methods for rates and proportions, 2nd edition. Wiley, New York, 1981
22.
go back to reference Baka N, Kaptein BL, de Bruijne M, van Walsum T, Giphart JE, Niessen WJ, Lelieveldt BPF: 2D–3D shape reconstruction of the distal femur from stereo X-ray imaging using statistical shape models. Med Image Anal 15(6):840–850, 2011PubMedCrossRef Baka N, Kaptein BL, de Bruijne M, van Walsum T, Giphart JE, Niessen WJ, Lelieveldt BPF: 2D–3D shape reconstruction of the distal femur from stereo X-ray imaging using statistical shape models. Med Image Anal 15(6):840–850, 2011PubMedCrossRef
23.
go back to reference Chaibi Y, Cresson T, Aubert B, Hausselle J, Neyret P, Hauger O, de Guise JA, Skalli W: Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Eng 15(5):457–466, 2012CrossRef Chaibi Y, Cresson T, Aubert B, Hausselle J, Neyret P, Hauger O, de Guise JA, Skalli W: Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Eng 15(5):457–466, 2012CrossRef
24.
go back to reference Heimann T, Meinzer HP: Statistical shape models for 3D medical image segmentation: a review. Med Image Anal 13(4):543–563, 2009PubMedCrossRef Heimann T, Meinzer HP: Statistical shape models for 3D medical image segmentation: a review. Med Image Anal 13(4):543–563, 2009PubMedCrossRef
25.
go back to reference Hartley RI, Zisserman A: Multiple view geometry in computer vision, Second edition. Cambridge University Press, Cambridge, 2004 Hartley RI, Zisserman A: Multiple view geometry in computer vision, Second edition. Cambridge University Press, Cambridge, 2004
26.
go back to reference Thelen P, Delin C, Folinais D, Radier C: Evaluation of a new low-dose biplanar system to assess lower-limb alignment in 3D: a phantom study. Skeletal Radiol 41:1287–1293, 2012PubMedCrossRef Thelen P, Delin C, Folinais D, Radier C: Evaluation of a new low-dose biplanar system to assess lower-limb alignment in 3D: a phantom study. Skeletal Radiol 41:1287–1293, 2012PubMedCrossRef
Metadata
Title
Design and Validation of Automated Femoral Bone Morphology Measurements in Cerebral Palsy
Authors
Noyeol Park
Jehee Lee
Ki Hyuk Sung
Moon Seok Park
Seungbum Koo
Publication date
01-04-2014
Publisher
Springer US
Published in
Journal of Imaging Informatics in Medicine / Issue 2/2014
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-013-9643-2

Other articles of this Issue 2/2014

Journal of Digital Imaging 2/2014 Go to the issue