Skip to main content
Top
Published in: Journal of Digital Imaging 6/2011

01-12-2011

Five Levels of PACS Modularity: Integrating 3D and Other Advanced Visualization Tools

Authors: Kenneth C. Wang, Ross W. Filice, James F. Philbin, Eliot L. Siegel, Paul G. Nagy

Published in: Journal of Imaging Informatics in Medicine | Issue 6/2011

Login to get access

Abstract

The current array of PACS products and 3D visualization tools presents a wide range of options for applying advanced visualization methods in clinical radiology. The emergence of server-based rendering techniques creates new opportunities for raising the level of clinical image review. However, best-of-breed implementations of core PACS technology, volumetric image navigation, and application-specific 3D packages will, in general, be supplied by different vendors. Integration issues should be carefully considered before deploying such systems. This work presents a classification scheme describing five tiers of PACS modularity and integration with advanced visualization tools, with the goals of characterizing current options for such integration, providing an approach for evaluating such systems, and discussing possible future architectures. These five levels of increasing PACS modularity begin with what was until recently the dominant model for integrating advanced visualization into the clinical radiologist's workflow, consisting of a dedicated stand-alone post-processing workstation in the reading room. Introduction of context-sharing, thin clients using server-based rendering, archive integration, and user-level application hosting at successive levels of the hierarchy lead to a modularized imaging architecture, which promotes user interface integration, resource efficiency, system performance, supportability, and flexibility. These technical factors and system metrics are discussed in the context of the proposed five-level classification scheme.
Literature
1.
go back to reference Kato Y, Katada K, Hayakawa M, Nakane M, Ogura Y, Sano K, Kanno T: Can 3D-CTA surpass DSA in diagnosis of cerebral aneurysm? Acta Neurochir 143:245–250, 2001CrossRef Kato Y, Katada K, Hayakawa M, Nakane M, Ogura Y, Sano K, Kanno T: Can 3D-CTA surpass DSA in diagnosis of cerebral aneurysm? Acta Neurochir 143:245–250, 2001CrossRef
2.
go back to reference Matsumoto M, Kodama N, Endo Y, Sakuma J, Suzuki KY, Sasaki T, Murakami K, Suzuki KE, Katakura T, Shishido: Dynamic 3D-CT angiography. Am J Neuroradiol 28:299–304, 2007PubMed Matsumoto M, Kodama N, Endo Y, Sakuma J, Suzuki KY, Sasaki T, Murakami K, Suzuki KE, Katakura T, Shishido: Dynamic 3D-CT angiography. Am J Neuroradiol 28:299–304, 2007PubMed
3.
go back to reference Rubin GD, Dake MD, Napel SA, McDonnell CH, Jeffrey RB: Three-dimensional spiral CT angiography of the abdomen: initial clinical experience. Radiology 186:147–152, 1993PubMed Rubin GD, Dake MD, Napel SA, McDonnell CH, Jeffrey RB: Three-dimensional spiral CT angiography of the abdomen: initial clinical experience. Radiology 186:147–152, 1993PubMed
4.
go back to reference Willmann JK, Wildermuth S: Multidetector-row CT angiography of upper- and lower-extremity peripheral arteries. Eur Radiol 15:D3–D9, 2005PubMedCrossRef Willmann JK, Wildermuth S: Multidetector-row CT angiography of upper- and lower-extremity peripheral arteries. Eur Radiol 15:D3–D9, 2005PubMedCrossRef
5.
go back to reference Desjardins B, Kazerooni EA: ECG-gated cardiac CT. Am J Roentgenol 182:993–1010, 2004 Desjardins B, Kazerooni EA: ECG-gated cardiac CT. Am J Roentgenol 182:993–1010, 2004
6.
go back to reference Lawler LP, Pannu HK, Fishman EK: MDCT evaluation of the coronary arteries, 2004: How we do it—data acquisition, postprocessing, display, and interpretation. Am J Roentgenol 184:1402–1412, 2005 Lawler LP, Pannu HK, Fishman EK: MDCT evaluation of the coronary arteries, 2004: How we do it—data acquisition, postprocessing, display, and interpretation. Am J Roentgenol 184:1402–1412, 2005
7.
go back to reference Macari M, Bini EJ, Jacobs SL, Lange N, Lui YW: Filling defects at CT colonography: pseudo- and diminutive lesions (the good), polyps (the bad), flat lesions, masses, and carcinomas (the ugly). Radiographics 23:1073–1091, 2003PubMedCrossRef Macari M, Bini EJ, Jacobs SL, Lange N, Lui YW: Filling defects at CT colonography: pseudo- and diminutive lesions (the good), polyps (the bad), flat lesions, masses, and carcinomas (the ugly). Radiographics 23:1073–1091, 2003PubMedCrossRef
8.
go back to reference Shi R, Schraedley-Desmond P, Napel S, Olcott EW, Jeffrey RB, Yee J, Zalis ME, Margolis D, Paik DS, Sherbondy AJ, Sundaram P, Beaulieu CF: CT colonography: influence of 3D viewing and polyp candidate features on interpretation with computer-aided detection. Radiology 239:768–776, 2006PubMedCrossRef Shi R, Schraedley-Desmond P, Napel S, Olcott EW, Jeffrey RB, Yee J, Zalis ME, Margolis D, Paik DS, Sherbondy AJ, Sundaram P, Beaulieu CF: CT colonography: influence of 3D viewing and polyp candidate features on interpretation with computer-aided detection. Radiology 239:768–776, 2006PubMedCrossRef
9.
go back to reference Soto JA, Lucey BC, Stuhlfaut JW, Varghese JC: Use of 3D imaging in CT of the acute trauma patient: impact of a PACS-based software package. Emergency Radiology 11:173–176, 2005PubMedCrossRef Soto JA, Lucey BC, Stuhlfaut JW, Varghese JC: Use of 3D imaging in CT of the acute trauma patient: impact of a PACS-based software package. Emergency Radiology 11:173–176, 2005PubMedCrossRef
10.
go back to reference Rodt T, Bartling SO, Zajaczek JE, Vafa MA, Kapapa T, Majdani O, Krauss JK, Zumkeller M, Matthies H, Becker H, Kaminsky J: Evaluation of surface and volume rendering in 3D-CT of facial fractures. Dentomaxillofacial Radiol 35:227–231, 2006CrossRef Rodt T, Bartling SO, Zajaczek JE, Vafa MA, Kapapa T, Majdani O, Krauss JK, Zumkeller M, Matthies H, Becker H, Kaminsky J: Evaluation of surface and volume rendering in 3D-CT of facial fractures. Dentomaxillofacial Radiol 35:227–231, 2006CrossRef
11.
go back to reference Horton KM, Fishman EK: Multidetector CT angiography of pancreatic carcinoma: part I, evaluation of arterial involvement. Am J Roentgenol 178:827–831, 2002 Horton KM, Fishman EK: Multidetector CT angiography of pancreatic carcinoma: part I, evaluation of arterial involvement. Am J Roentgenol 178:827–831, 2002
12.
go back to reference Takeshita K, Kutomi K, Takada K, Kohtake H, Furui S: 3D pancreatic arteriography with MDCT during intraarterial infusion of contrast material in the detection and localization of insulinomas. Am J Roentgenol 184:852–854, 2005 Takeshita K, Kutomi K, Takada K, Kohtake H, Furui S: 3D pancreatic arteriography with MDCT during intraarterial infusion of contrast material in the detection and localization of insulinomas. Am J Roentgenol 184:852–854, 2005
13.
go back to reference Silverman PM, Zeiberg AS, Sessions RB, Troost TR, Davros WJ, Zeman RK: Helical CT of the upper airway: normal and abnormal findings on three-dimensional reconstructed images. Am J Roentgenol 165:541–546, 1995 Silverman PM, Zeiberg AS, Sessions RB, Troost TR, Davros WJ, Zeman RK: Helical CT of the upper airway: normal and abnormal findings on three-dimensional reconstructed images. Am J Roentgenol 165:541–546, 1995
14.
go back to reference Horton KM, Horton MR, Fishman EK: Advanced visualization of airways with 64-MDCT: 3D mapping and virtual bronchoscopy. Am J Roentgenol 189:1387–1396, 2007CrossRef Horton KM, Horton MR, Fishman EK: Advanced visualization of airways with 64-MDCT: 3D mapping and virtual bronchoscopy. Am J Roentgenol 189:1387–1396, 2007CrossRef
15.
go back to reference Croitoru S, Gross M, Barmeir E: Duplicated ectopic ureter with vaginal insertion: 3D CT urography with IV and percutaneous contrast administration. AJR 189:W272–W274, 2007PubMedCrossRef Croitoru S, Gross M, Barmeir E: Duplicated ectopic ureter with vaginal insertion: 3D CT urography with IV and percutaneous contrast administration. AJR 189:W272–W274, 2007PubMedCrossRef
16.
go back to reference Levoy M. Polygon-assisted JPEG and MPEG compression of synthetic images. Proceedings Special Interest Group on Computer Graphics and Interactive Techniques, 21–28, 1995. Levoy M. Polygon-assisted JPEG and MPEG compression of synthetic images. Proceedings Special Interest Group on Computer Graphics and Interactive Techniques, 21–28, 1995.
17.
go back to reference Yoon I, Neumann U (2000) Web-based remote rendering with IBRAC (image-based rendering acceleration and compression). Eurographics 19:321–330 Yoon I, Neumann U (2000) Web-based remote rendering with IBRAC (image-based rendering acceleration and compression). Eurographics 19:321–330
18.
go back to reference Bohne-Lang A, Groch W-D, Ranzinger R: AISMIG – An interactive server-side molecule image generator. Nucleic Acids Res 33:W705–W709, 2005PubMedCrossRef Bohne-Lang A, Groch W-D, Ranzinger R: AISMIG – An interactive server-side molecule image generator. Nucleic Acids Res 33:W705–W709, 2005PubMedCrossRef
19.
go back to reference Poliakov AV, Albright E, Corina D et al. (2001) Server-based approach to web visualization of integrated 3D medical image data. Proc Am Med Inform Assoc Symp 533–537 Poliakov AV, Albright E, Corina D et al. (2001) Server-based approach to web visualization of integrated 3D medical image data. Proc Am Med Inform Assoc Symp 533–537
20.
go back to reference Erickson BJ, Persons KR, Hangiandreou NJ, James EM, Hanna CJ, Gehring DG: Requirements for an enterprise digital image archive. Journal of Digit Imaging 14:72–82, 2001CrossRef Erickson BJ, Persons KR, Hangiandreou NJ, James EM, Hanna CJ, Gehring DG: Requirements for an enterprise digital image archive. Journal of Digit Imaging 14:72–82, 2001CrossRef
21.
go back to reference Liu BJ, Cao F, Zhou MZ, Mogel G, Documet L: Trends in PACS image storage and archive. Computerized Medical Imaging Graphics 27:165–174, 2003CrossRef Liu BJ, Cao F, Zhou MZ, Mogel G, Documet L: Trends in PACS image storage and archive. Computerized Medical Imaging Graphics 27:165–174, 2003CrossRef
22.
go back to reference Huang HK: Enterprise PACS and image distribution. Computerized Medical Imaging and Graphics 27:241–253, 2003PubMedCrossRef Huang HK: Enterprise PACS and image distribution. Computerized Medical Imaging and Graphics 27:241–253, 2003PubMedCrossRef
23.
go back to reference Toland C, Meenan C, Toland M, Safdar N, Vandermeer P, Nagy P: A suggested classification guide for PACS client applications: the five degrees of thickness. Journal of Digital Imaging 19:78–83, 2006PubMedCrossRef Toland C, Meenan C, Toland M, Safdar N, Vandermeer P, Nagy P: A suggested classification guide for PACS client applications: the five degrees of thickness. Journal of Digital Imaging 19:78–83, 2006PubMedCrossRef
25.
go back to reference Paladini G, Azar FS: An extensible imaging platform for optical imaging applications. Proc SPIE 7171:717108, 2009CrossRef Paladini G, Azar FS: An extensible imaging platform for optical imaging applications. Proc SPIE 7171:717108, 2009CrossRef
26.
go back to reference Prior FW, Erickson BJ, Tarbox L: Open source software projects of the caBIG in vivo imaging workspace software special interest group. Journal of Digital Imaging 20:94–100, 2007PubMedCrossRef Prior FW, Erickson BJ, Tarbox L: Open source software projects of the caBIG in vivo imaging workspace software special interest group. Journal of Digital Imaging 20:94–100, 2007PubMedCrossRef
Metadata
Title
Five Levels of PACS Modularity: Integrating 3D and Other Advanced Visualization Tools
Authors
Kenneth C. Wang
Ross W. Filice
James F. Philbin
Eliot L. Siegel
Paul G. Nagy
Publication date
01-12-2011
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 6/2011
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-011-9366-1

Other articles of this Issue 6/2011

Journal of Digital Imaging 6/2011 Go to the issue