Abstract

Some renal diseases cause changes in the structure of the glomerular basement membranes (GBM). Measurement of the thickness of the GBM can be performed on transmission electron microscopy (TEM) images of renal biopsy samples. Increased thickness of the GBM is observed in patients with diabetic nephropathy. Abnormally thin GBMs are associated with hematuria. We propose image processing methods for the detection and measurement of the GBM. The methods include edge detection, morphological image processing, active contour modeling, skeletonization, and statistical analysis of the width of the GBM. In the present pilot study, the methods were tested with 34 TEM images of six patients. The estimated mean and standard deviation of the GBM width for a patient with normal GBM were 348 ± 135 nm; those for a patient with thin GBMs due to hematuria were 227 ± 94 nm; and those for a patient with diabetic nephropathy were 1,152 ± 411 nm. Comparison with manual measurements by an experienced renal pathologist indicated low error in the range of 36 ± 11 nm.
Literature
1.
go back to reference Vize PD, Woolf AS, Bard JBL: The Kidney, From Normal Development to Congenital Disease. London, UK: Academic, 2003 Vize PD, Woolf AS, Bard JBL: The Kidney, From Normal Development to Congenital Disease. London, UK: Academic, 2003
2.
go back to reference Schwartz MM, Jennette JH, Olson JL, Silva FG: Pathology of the Kidney, 6th edition. New York, NY: Lippincott Williams & Wilkins, 2007 Schwartz MM, Jennette JH, Olson JL, Silva FG: Pathology of the Kidney, 6th edition. New York, NY: Lippincott Williams & Wilkins, 2007
3.
go back to reference Moriya T, Groppoli TJ, Kim Y, Mauer M: Quantitative immunoelectron microscopy of type VI collagen in glomeruli in type I diabetic patients. Kidney Int 59:317–323, 2001CrossRefPubMed Moriya T, Groppoli TJ, Kim Y, Mauer M: Quantitative immunoelectron microscopy of type VI collagen in glomeruli in type I diabetic patients. Kidney Int 59:317–323, 2001CrossRefPubMed
4.
go back to reference Coleman M, David W, Haynes G: Glomerular basement membrane abnormalities associated with apparently idiopathic hematuria. Human Pathol 17:1022–1030, 1986CrossRef Coleman M, David W, Haynes G: Glomerular basement membrane abnormalities associated with apparently idiopathic hematuria. Human Pathol 17:1022–1030, 1986CrossRef
5.
go back to reference Gubler MC, Levy M, Broyer M: Alport’s syndrome: a report of 58 cases and a review of the literature. Am J Med Sci 70:493–505, 1981CrossRef Gubler MC, Levy M, Broyer M: Alport’s syndrome: a report of 58 cases and a review of the literature. Am J Med Sci 70:493–505, 1981CrossRef
6.
go back to reference Habib R, Gubler MC, Hinglais N: Alport’s syndrome: experience at Hospital Necker. Kidney Int 11:20–28, 1982 Habib R, Gubler MC, Hinglais N: Alport’s syndrome: experience at Hospital Necker. Kidney Int 11:20–28, 1982
7.
go back to reference Saxena S, Davies DJ, Kirsner RLG: Thin basement membranes in minimally abnormal glomeruli. Prog Clin Pathol 43:32–38, 1990CrossRef Saxena S, Davies DJ, Kirsner RLG: Thin basement membranes in minimally abnormal glomeruli. Prog Clin Pathol 43:32–38, 1990CrossRef
8.
go back to reference Basta-Jovanovic G, Venkataseshan VS, Gil J: Morphometric analysis of glomerular basement membranes in thin basement disease. Clin Nephrol 33:110–114, 1990PubMed Basta-Jovanovic G, Venkataseshan VS, Gil J: Morphometric analysis of glomerular basement membranes in thin basement disease. Clin Nephrol 33:110–114, 1990PubMed
9.
go back to reference Osterby R: Thin glomerular basement membrane nephropathy: incidence in 3471 consecutive renal biopsies examined by electron microscopy. Arch Pathol Lab Med 130:699–706, 2006 Osterby R: Thin glomerular basement membrane nephropathy: incidence in 3471 consecutive renal biopsies examined by electron microscopy. Arch Pathol Lab Med 130:699–706, 2006
10.
go back to reference Osterby R: Morphometric studies of the peripheral glomerular basement membrane in early juvenile diabetes. I. Development of initial basement membrane thickening. Diabetologica 8:84–92, 1972CrossRef Osterby R: Morphometric studies of the peripheral glomerular basement membrane in early juvenile diabetes. I. Development of initial basement membrane thickening. Diabetologica 8:84–92, 1972CrossRef
11.
go back to reference Li JJ, Kwak SJ, Jung DS, Kim JJ, Yoo TH, Ryu DR, Han SH, Choi HY, Lee JE, Moon SJ, Kim DK, Han DS, Kang SW: Podocyte biology in diabetic nephropathy. Kidney Inter Suppl S:36–42, 2007 Li JJ, Kwak SJ, Jung DS, Kim JJ, Yoo TH, Ryu DR, Han SH, Choi HY, Lee JE, Moon SJ, Kim DK, Han DS, Kang SW: Podocyte biology in diabetic nephropathy. Kidney Inter Suppl S:36–42, 2007
12.
go back to reference Osawa G, Kimmelstiel P, Sailing V: Thickness of glomerular basement membranes. Clinical Pathology, 45:7–20, 1966 Osawa G, Kimmelstiel P, Sailing V: Thickness of glomerular basement membranes. Clinical Pathology, 45:7–20, 1966
13.
go back to reference Ong SH, Giam ST, Jayasooriah, Sinniah R: Adaptive window-based tracking for the detection of membrane structures in kidney electron micrographs. Mach Vis Appl 6:215–223, 1993 Ong SH, Giam ST, Jayasooriah, Sinniah R: Adaptive window-based tracking for the detection of membrane structures in kidney electron micrographs. Mach Vis Appl 6:215–223, 1993
14.
go back to reference Ong SH, Jin XC, Jayasooriah, Sinniah R: Image analysis of tissue sections. Comput Biol Med 26:269–279, 1996 Ong SH, Jin XC, Jayasooriah, Sinniah R: Image analysis of tissue sections. Comput Biol Med 26:269–279, 1996
15.
go back to reference Canny J: A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8(6):679–698, 1986CrossRef Canny J: A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8(6):679–698, 1986CrossRef
16.
go back to reference Goutsias J, Batman S: Morphological methods for biomedical image analysis. In: Sonka M, Fitzpatrick JM Eds. Handbook of Medical Imaging, Volume 2: Medical Image Processing and Analysis. Bellingham, WA: SPIE, 2000, pp 175–272CrossRef Goutsias J, Batman S: Morphological methods for biomedical image analysis. In: Sonka M, Fitzpatrick JM Eds. Handbook of Medical Imaging, Volume 2: Medical Image Processing and Analysis. Bellingham, WA: SPIE, 2000, pp 175–272CrossRef
17.
go back to reference Kass M, Witkin A, Terzopoulos D: Snakes: Active contour models. Int J Comput Vis 1:321–331, 1987CrossRef Kass M, Witkin A, Terzopoulos D: Snakes: Active contour models. Int J Comput Vis 1:321–331, 1987CrossRef
18.
go back to reference Xu C, Pham DL, Prince JL: Image segmentation using deformable models. In: Sonka M, Fitzpatrick JM Eds. Handbook of Medical Imaging, Volume 2: Medical Image Processing and Analysis. Bellingham, WA: SPIE, 2000, pp 129–174CrossRef Xu C, Pham DL, Prince JL: Image segmentation using deformable models. In: Sonka M, Fitzpatrick JM Eds. Handbook of Medical Imaging, Volume 2: Medical Image Processing and Analysis. Bellingham, WA: SPIE, 2000, pp 129–174CrossRef
19.
go back to reference Gonzalez RC, Woods RE: Digital Image ProcessingReading, MA: Addison-Wesley, 1993 Gonzalez RC, Woods RE: Digital Image ProcessingReading, MA: Addison-Wesley, 1993
20.
go back to reference Rangayyan RM, Kamenetsky I, Benediktsson H: Segmentation and analysis of the glomerular basement membrane using active contour models. In The IET 4th International Conference on Advances in Medical and Signal Processing (MEDSIP 2008), page Paper 2.1.3 (4 pages), Santa Margherita Ligure, Italy, July 2008 Rangayyan RM, Kamenetsky I, Benediktsson H: Segmentation and analysis of the glomerular basement membrane using active contour models. In The IET 4th International Conference on Advances in Medical and Signal Processing (MEDSIP 2008), page Paper 2.1.3 (4 pages), Santa Margherita Ligure, Italy, July 2008
21.
go back to reference Rangayyan RM: Biomedical Image Analysis. Boca Raton, FL: CRC, 2005 Rangayyan RM: Biomedical Image Analysis. Boca Raton, FL: CRC, 2005
22.
go back to reference Wgrowska-Danilewicz M, Danilewicz M: Current position of electron microscopy in the diagnosis of glomerular diseases. Pol J Pathol 58:87–92, 2007 Wgrowska-Danilewicz M, Danilewicz M: Current position of electron microscopy in the diagnosis of glomerular diseases. Pol J Pathol 58:87–92, 2007
24.
go back to reference Cohen LD: On active contour models and balloons. Comput Vis Graph Image Process 53:211–218, 1991 Cohen LD: On active contour models and balloons. Comput Vis Graph Image Process 53:211–218, 1991
25.
go back to reference Cohen LD, Cohen I: Finite-element methods for active contour models and balloons for 2-d and 3-d images. IEEE Trans Pattern Anal Mach Intell 15:1131–1147, 1993CrossRef Cohen LD, Cohen I: Finite-element methods for active contour models and balloons for 2-d and 3-d images. IEEE Trans Pattern Anal Mach Intell 15:1131–1147, 1993CrossRef
26.
go back to reference Xu C, Prince JL: Snakes, shapes, and gradient vector flow. IEEE Trans Image Process 7:359–369, 1998CrossRefPubMed Xu C, Prince JL: Snakes, shapes, and gradient vector flow. IEEE Trans Image Process 7:359–369, 1998CrossRefPubMed
27.
go back to reference Blum H: A transformation for extracting new descriptors of shape. In: Wathen-Dunn W Ed. Models for the Perception of Speech and Visual Form. Cambridge, MA: MIT, 1967 Blum H: A transformation for extracting new descriptors of shape. In: Wathen-Dunn W Ed. Models for the Perception of Speech and Visual Form. Cambridge, MA: MIT, 1967
28.
go back to reference Perona P, Malik J: Scale-space and edge detection using anisotropic diffusion. IEEE Trans on Pattern Anal Mach Intell 12(7):629–639, 1990CrossRef Perona P, Malik J: Scale-space and edge detection using anisotropic diffusion. IEEE Trans on Pattern Anal Mach Intell 12(7):629–639, 1990CrossRef
29.
go back to reference Papari G, Campisi P, Petkov N, Neri A: Contour detection by multiresolution surround inhibition. In IEEE International Conference on Image Processing, pages 749–752. IEEE, 2006 Papari G, Campisi P, Petkov N, Neri A: Contour detection by multiresolution surround inhibition. In IEEE International Conference on Image Processing, pages 749–752. IEEE, 2006
Metadata
Title
Segmentation and Analysis of the Glomerular Basement Membrane in Renal Biopsy Samples Using Active Contours: A Pilot Study
Authors
Rangaraj M. Rangayyan
Ilya Kamenetsky
Hallgrimur Benediktsson
Publication date
01-06-2010
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 3/2010
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-009-9188-6

Other articles of this Issue 3/2010

Journal of Digital Imaging 3/2010 Go to the issue