Skip to main content
Top
Published in: Journal of Digital Imaging 3/2009

01-06-2009

The Application of JPEG2000 in Virtual Microscopy

Authors: Vilppu J. Tuominen, Jorma Isola

Published in: Journal of Imaging Informatics in Medicine | Issue 3/2009

Login to get access

Abstract

Virtual microscopy (i.e., the viewing of entire microscope specimens on a computer display) is becoming widely applied in microscopy teaching and clinical laboratory medicine. Despite rapidly increasing use, virtual microscopy currently lacks of a universally accepted image format. A promising candidate is JPEG2000, which has potential advantages for handling gigabyte-sized virtual slides. To date, no JPEG2000-based software has been specifically suited for virtual microscopy. To study the utility of JPEG2000 in virtual microscopy, we first optimized JPEG2000 code-stream parameters for virtual slide viewing (i.e., fast navigation, zooming, and use of an overview window). Compression using ratios 25:1–30:1 with the irreversible wavelet filter were found to provide the best compromise between file size and image quality. Optimal code-stream parameters also consisted of 10 wavelet decomposition levels, progression order Resolution-Position-Component-Layer (RPCL), a precinct size of 128 × 128, and code-block size of 64 × 64. Tiling and the use of multiple quality layers were deemed unnecessary. A compression application (JVScomp) was developed for creating optimally parameterized JPEG2000 virtual slides. A viewing application (JVSview) was developed specifically for virtual microscopy, offering all of the basic viewing functions. JVSview also supports viewing of focus stacks, embedding of textual descriptions, and defining regions of interest as metadata. Combined with our server application (JVSserv), virtual slides can be viewed over networks by employing the JPEG2000 Interactive Protocol (JPIP). The software can be tested using virtual slide examples located on our public JPIP server (http://​jvsmicroscope.​uta.​fi/​). The software package is freely downloadable and usable for noncommercial purposes.
Literature
1.
go back to reference Weinstein RS: Innovations in medical imaging and virtual microscopy. Hum Pathol 36(4):317–319, 2005PubMedCrossRef Weinstein RS: Innovations in medical imaging and virtual microscopy. Hum Pathol 36(4):317–319, 2005PubMedCrossRef
2.
go back to reference Lundin M, Lundin J, Helin H, Isola J: A digital atlas of breast histopathology: an application of web based virtual microscopy. J Clin Pathol 57(12):1288–1291, 2004PubMedCrossRef Lundin M, Lundin J, Helin H, Isola J: A digital atlas of breast histopathology: an application of web based virtual microscopy. J Clin Pathol 57(12):1288–1291, 2004PubMedCrossRef
3.
go back to reference Kumar RK, Freeman B, Velan GM, De Permentier PJ: Integrating histology and histopathology teaching in practical classes using virtual slides. Anat Rec B New Anat 289(4):128–133, 2006PubMed Kumar RK, Freeman B, Velan GM, De Permentier PJ: Integrating histology and histopathology teaching in practical classes using virtual slides. Anat Rec B New Anat 289(4):128–133, 2006PubMed
5.
go back to reference Helin H, Lundin M, Lundin J, Martikainen P, Tammela T, Helin H, van der Kwast T, Isola J: Web-based virtual microscopy in teaching and standardizing Gleason grading. Hum Pathol 36(4):381–386, 2005PubMedCrossRef Helin H, Lundin M, Lundin J, Martikainen P, Tammela T, Helin H, van der Kwast T, Isola J: Web-based virtual microscopy in teaching and standardizing Gleason grading. Hum Pathol 36(4):381–386, 2005PubMedCrossRef
6.
go back to reference Furness P: A randomized controlled trial of the diagnostic accuracy of internet-based telepathology compared with conventional microscopy. Histopathology 50(2):266–273, 2007PubMedCrossRef Furness P: A randomized controlled trial of the diagnostic accuracy of internet-based telepathology compared with conventional microscopy. Histopathology 50(2):266–273, 2007PubMedCrossRef
7.
go back to reference Rojo MG, García GB, Mateos CP, García JG, Vicente MC: Critical Comparison of 31 Commercially Available Digital Slide Systems in Pathology. Int J Surg Pathol 14(4):285–305, 2006PubMedCrossRef Rojo MG, García GB, Mateos CP, García JG, Vicente MC: Critical Comparison of 31 Commercially Available Digital Slide Systems in Pathology. Int J Surg Pathol 14(4):285–305, 2006PubMedCrossRef
8.
go back to reference Burthem J, Brereton M, Ardern J, Hickman L, Seal L, Serrant A, Hutchinson CV, Wells E, McTaggart P, De la Salle B, Parker–Williams J, Hyde K: The use of digital ’virtual slides’ in the quality assessment of haematological morphology: results of a pilot exercise involving UK NEQAS(H) participants. Br J Haematol 130(2):293–296, 2005PubMedCrossRef Burthem J, Brereton M, Ardern J, Hickman L, Seal L, Serrant A, Hutchinson CV, Wells E, McTaggart P, De la Salle B, Parker–Williams J, Hyde K: The use of digital ’virtual slides’ in the quality assessment of haematological morphology: results of a pilot exercise involving UK NEQAS(H) participants. Br J Haematol 130(2):293–296, 2005PubMedCrossRef
11.
go back to reference Information technology—JPEG 2000 image coding system: Core coding system. ISO/IEC 15444-1, 2000 | ITU-T Recommendation T.800, 2002 Information technology—JPEG 2000 image coding system: Core coding system. ISO/IEC 15444-1, 2000 | ITU-T Recommendation T.800, 2002
12.
go back to reference Taubman DS, Marcellin MW: JPEG2000: Image Compression Fundamentals, Standards and Practice: Springer, 2002 Taubman DS, Marcellin MW: JPEG2000: Image Compression Fundamentals, Standards and Practice: Springer, 2002
13.
go back to reference Skodras A, Christopoulos C, Ebrahimi T: The JPEG 2000 Still Image Compression Standard. IEEE Signal Proc Mag 18(5):36–58, 2001CrossRef Skodras A, Christopoulos C, Ebrahimi T: The JPEG 2000 Still Image Compression Standard. IEEE Signal Proc Mag 18(5):36–58, 2001CrossRef
14.
go back to reference Rabbani M, Joshi R: An overview of the JPEG 2000 still image compression standard. Signal Process: Image Comm 17(1):3–48, 2002CrossRef Rabbani M, Joshi R: An overview of the JPEG 2000 still image compression standard. Signal Process: Image Comm 17(1):3–48, 2002CrossRef
15.
go back to reference Information technology—JPEG 2000 image coding system: Extensions. ISO/IEC 15444-2, 2002 | ITU-T Recommendation T.801, 2002 Information technology—JPEG 2000 image coding system: Extensions. ISO/IEC 15444-2, 2002 | ITU-T Recommendation T.801, 2002
16.
go back to reference Information technology—JPEG 2000 image coding system: Interactivity tools, APIs and protocols. ISO/IEC 15444-9, 2005 | ITU-T Recommendation T.808, 2005 Information technology—JPEG 2000 image coding system: Interactivity tools, APIs and protocols. ISO/IEC 15444-9, 2005 | ITU-T Recommendation T.808, 2005
17.
go back to reference Taubman DS, Prandolini R: Architecture, Philosophy and Performance of JPIP: Internet Protocol Standard for JPEG2000. Proc SPIE 5150:791–805, 2003 Taubman DS, Prandolini R: Architecture, Philosophy and Performance of JPIP: Internet Protocol Standard for JPEG2000. Proc SPIE 5150:791–805, 2003
23.
go back to reference Gao M, Bridgman P, Kumar S: Computer Aided Prostate Cancer Diagnosis Using Image Enhancement and JPEG2000. Proc SPIE 5203:323–334, 2003CrossRef Gao M, Bridgman P, Kumar S: Computer Aided Prostate Cancer Diagnosis Using Image Enhancement and JPEG2000. Proc SPIE 5203:323–334, 2003CrossRef
25.
go back to reference Santa-Cruz D, Grosbois R, Ebrahimi T: JPEG 2000 performance evaluation and assessment. Signal Process: Image Comm 17(1):113–130, 2002CrossRef Santa-Cruz D, Grosbois R, Ebrahimi T: JPEG 2000 performance evaluation and assessment. Signal Process: Image Comm 17(1):113–130, 2002CrossRef
26.
go back to reference Ebrahimi F, Chamik M, Winkler S: JPEG vs. JPEG2000: An Objective Comparison of Image Encoding Quality. Proc SPIE 5558:300–308, 2004CrossRef Ebrahimi F, Chamik M, Winkler S: JPEG vs. JPEG2000: An Objective Comparison of Image Encoding Quality. Proc SPIE 5558:300–308, 2004CrossRef
29.
go back to reference Digital Imaging and Communications in Medicine (DICOM), Supplement 61: JPEG 2000 Transfer Syntaxes. Available at ftp://medical.nema.org/medical/dicom/final/sup61_ft.pdf. Accessed 12 July 2007 Digital Imaging and Communications in Medicine (DICOM), Supplement 61: JPEG 2000 Transfer Syntaxes. Available at ftp://medical.nema.org/medical/dicom/final/sup61_ft.pdf. Accessed 12 July 2007
30.
go back to reference Digital Imaging and Communications in Medicine (DICOM), Supplement 106: JPEG 2000 Interactive Protocol. Available at ftp://medical.nema.org/medical/dicom/final/sup106_ft.pdf. Accessed 12 July 2007 Digital Imaging and Communications in Medicine (DICOM), Supplement 106: JPEG 2000 Interactive Protocol. Available at ftp://medical.nema.org/medical/dicom/final/sup106_ft.pdf. Accessed 12 July 2007
Metadata
Title
The Application of JPEG2000 in Virtual Microscopy
Authors
Vilppu J. Tuominen
Jorma Isola
Publication date
01-06-2009
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 3/2009
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-007-9090-z

Other articles of this Issue 3/2009

Journal of Digital Imaging 3/2009 Go to the issue