Skip to main content
Top
Published in: Journal of Digital Imaging 1/2008

01-03-2008

Integration of Temporal Subtraction and Nodule Detection System for Digital Chest Radiographs into Picture Archiving and Communication System (PACS): Four-year Experience

Authors: Shuji Sakai, Hidetake Yabuuchi, Yoshio Matsuo, Takashi Okafuji, Takeshi Kamitani, Hiroshi Honda, Keiji Yamamoto, Keiichi Fujiwara, Naoki Sugiyama, Kunio Doi

Published in: Journal of Imaging Informatics in Medicine | Issue 1/2008

Login to get access

Abstract

Since May 2002, temporal subtraction and nodule detection systems for digital chest radiographs have been integrated into our hospital’s picture archiving and communication systems (PACS). Image data of digital chest radiographs were stored in PACS with the digital image and communication in medicine (DICOM) protocol. Temporal subtraction and nodule detection images were produced automatically in an exclusive server and delivered with current and previous images to the work stations. The problems that we faced and the solutions that we arrived at were analyzed. We encountered four major problems. The first problem, as a result of the storage of the original images’ data with the upside-down, reverse, or lying-down positioning on portable chest radiographs, was solved by postponing the original data storage for 30 min. The second problem, the variable matrix sizes of chest radiographs obtained with flat-panel detectors (FPDs), was solved by improving the computer algorithm to produce consistent temporal subtraction images. The third problem, the production of temporal subtraction images of low quality, could not be solved fundamentally when the original images were obtained with different modalities. The fourth problem, an excessive false-positive rate on the nodule detection system, was solved by adjusting this system to chest radiographs obtained in our hospital. Integration of the temporal subtraction and nodule detection system into our hospital’s PACS was customized successfully; this experience may be helpful to other hospitals.
Literature
1.
go back to reference Shah PK, Austin JH, White CS, Patel P, Haramati LB, Pearson GD, Shiau MC, Berkmen YM: Missed non-small cell lung cancer: radiographic findings of potentially resectable lesions evident only in retrospect. Radiology 226:235–241, 2003PubMedCrossRef Shah PK, Austin JH, White CS, Patel P, Haramati LB, Pearson GD, Shiau MC, Berkmen YM: Missed non-small cell lung cancer: radiographic findings of potentially resectable lesions evident only in retrospect. Radiology 226:235–241, 2003PubMedCrossRef
2.
go back to reference Kaneko M, Eguchi K, Ohmatsu H, Kakinuma R, Naruke T, Suemasu K, Moriyama N: Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography. Radiology 201:798–802, 1996PubMed Kaneko M, Eguchi K, Ohmatsu H, Kakinuma R, Naruke T, Suemasu K, Moriyama N: Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography. Radiology 201:798–802, 1996PubMed
3.
go back to reference Doi K: Current status and future potential of computer-aided diagnosis in medical imaging. Br J Radiol 78:S3–S19, 2005PubMedCrossRef Doi K: Current status and future potential of computer-aided diagnosis in medical imaging. Br J Radiol 78:S3–S19, 2005PubMedCrossRef
4.
go back to reference Sakai S, Soeda H, Furuya A, Yabuuchi H, Okafuji T, Yamamoto K, Honda H, Doi K: Evaluation of the image quality of temporal subtraction images produced automatically in a PACS environment. J Digit Imaging 19(4):383–390, 2006PubMedCrossRef Sakai S, Soeda H, Furuya A, Yabuuchi H, Okafuji T, Yamamoto K, Honda H, Doi K: Evaluation of the image quality of temporal subtraction images produced automatically in a PACS environment. J Digit Imaging 19(4):383–390, 2006PubMedCrossRef
5.
go back to reference Morishita J, Watanabe H, Katsuragawa S, Oda N, Sukenobu Y, Okazaki H, Nakata H, Doi K: Investigation of misfiled cases in the PACS environment and a solution to prevent filing errors for chest radiographs. Acad Radiol 12:97–103, 2005PubMedCrossRef Morishita J, Watanabe H, Katsuragawa S, Oda N, Sukenobu Y, Okazaki H, Nakata H, Doi K: Investigation of misfiled cases in the PACS environment and a solution to prevent filing errors for chest radiographs. Acad Radiol 12:97–103, 2005PubMedCrossRef
6.
go back to reference Kano A, Doi K, MacMahon H, Hassell DD, Giger ML: Digital image subtraction of temporally sequential chest images for detection of interval change. Med Phys 21:453–461, 1994PubMedCrossRef Kano A, Doi K, MacMahon H, Hassell DD, Giger ML: Digital image subtraction of temporally sequential chest images for detection of interval change. Med Phys 21:453–461, 1994PubMedCrossRef
7.
go back to reference Kobayashi T, Xu XW, MacMahon H, Metz CE, Doi K: Effect of a computer-aided diagnosis scheme on radiologists’ performance in detection of lung nodules on radiographs. Radiology 199:843–848, 1996PubMed Kobayashi T, Xu XW, MacMahon H, Metz CE, Doi K: Effect of a computer-aided diagnosis scheme on radiologists’ performance in detection of lung nodules on radiographs. Radiology 199:843–848, 1996PubMed
8.
go back to reference Katsuragawa S, Tagashira H, Li Q, et al: Comparison of the quality of temporal subtraction images obtained with manual and automated methods of digital chest radiography. J Digit Imaging 12:166–172, 1999PubMedCrossRef Katsuragawa S, Tagashira H, Li Q, et al: Comparison of the quality of temporal subtraction images obtained with manual and automated methods of digital chest radiography. J Digit Imaging 12:166–172, 1999PubMedCrossRef
9.
go back to reference Shiraishi J, Katsuragawa S, Ikezoe J, et al: Development of a digital image database for chest radiographs with and without a lung nodule: receiver operating characteristic analysis of radiologists’ detection of pulmonary nodules. AJR 174:71–74, 2000PubMed Shiraishi J, Katsuragawa S, Ikezoe J, et al: Development of a digital image database for chest radiographs with and without a lung nodule: receiver operating characteristic analysis of radiologists’ detection of pulmonary nodules. AJR 174:71–74, 2000PubMed
10.
go back to reference Kakeda S, Moriya J, Sato H, et al: Improved detection of lung nodules on chest radiographs using a commercial computer-aided diagnosis system. AJR 182:505–510, 2004PubMed Kakeda S, Moriya J, Sato H, et al: Improved detection of lung nodules on chest radiographs using a commercial computer-aided diagnosis system. AJR 182:505–510, 2004PubMed
11.
go back to reference Sakai S, Soeda H, Takahashi N, Okafuji T, Yoshitake T, Yabuuchi H, Yoshino I, Yamamoto K, Honda H, Doi K: Computer-aided nodule detection on digital chest radiography: validation test on consecutive T1 cases of resectable lung cancer. J Digit Imaging 19(4):376–382, 2006PubMedCrossRef Sakai S, Soeda H, Takahashi N, Okafuji T, Yoshitake T, Yabuuchi H, Yoshino I, Yamamoto K, Honda H, Doi K: Computer-aided nodule detection on digital chest radiography: validation test on consecutive T1 cases of resectable lung cancer. J Digit Imaging 19(4):376–382, 2006PubMedCrossRef
12.
go back to reference Johkoh T, Kozuka T, Tomiyama N, Hamada S, Honda O, Mihara N, Koyama M, Tsubamoto M, Maeda M, Nakamura H, Saki H, Fujiwara K: Temporal subtraction for detection of solitary pulmonary nodules on chest radiographs: evaluation of a commercially available computer-aided diagnosis system. Radiology 223:806–811, 2002PubMedCrossRef Johkoh T, Kozuka T, Tomiyama N, Hamada S, Honda O, Mihara N, Koyama M, Tsubamoto M, Maeda M, Nakamura H, Saki H, Fujiwara K: Temporal subtraction for detection of solitary pulmonary nodules on chest radiographs: evaluation of a commercially available computer-aided diagnosis system. Radiology 223:806–811, 2002PubMedCrossRef
13.
go back to reference Tsubamoto M, Johkoh T, Kozuka T, Tomiyama N, Hamada S, Honda O, Mihara N, Koyama M, Maeda M, Nakamura H, Fujiwara K: Temporal subtraction for the detection of hazy pulmonary opacities on chest radiography. AJR 179:467–471, 2002PubMed Tsubamoto M, Johkoh T, Kozuka T, Tomiyama N, Hamada S, Honda O, Mihara N, Koyama M, Maeda M, Nakamura H, Fujiwara K: Temporal subtraction for the detection of hazy pulmonary opacities on chest radiography. AJR 179:467–471, 2002PubMed
14.
go back to reference Prokop M, Neitzel U, Schaefer-Prokop C: Principles of image processing in digital chest radiography. J Thorac Imaging 18:148–164, 2003PubMedCrossRef Prokop M, Neitzel U, Schaefer-Prokop C: Principles of image processing in digital chest radiography. J Thorac Imaging 18:148–164, 2003PubMedCrossRef
15.
go back to reference Fernandez-Bayo J, Barbero O, Rubies C, Sentis M, Donoso L: Distributing medical images with internet technologies: a DICOM web server and a DICOM java viewer. Radiographics 20:581–590, 2000PubMed Fernandez-Bayo J, Barbero O, Rubies C, Sentis M, Donoso L: Distributing medical images with internet technologies: a DICOM web server and a DICOM java viewer. Radiographics 20:581–590, 2000PubMed
Metadata
Title
Integration of Temporal Subtraction and Nodule Detection System for Digital Chest Radiographs into Picture Archiving and Communication System (PACS): Four-year Experience
Authors
Shuji Sakai
Hidetake Yabuuchi
Yoshio Matsuo
Takashi Okafuji
Takeshi Kamitani
Hiroshi Honda
Keiji Yamamoto
Keiichi Fujiwara
Naoki Sugiyama
Kunio Doi
Publication date
01-03-2008
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 1/2008
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-007-9014-y

Other articles of this Issue 1/2008

Journal of Digital Imaging 1/2008 Go to the issue