Published in: Journal of Digital Imaging 2/2006

01-06-2006

Optimization of Dose and Image Quality for Computed Radiography and Digital Radiography

Authors: John E. Aldrich, Emerenciana Duran, Pat Dunlop, John R. Mayo

Published in: Journal of Imaging Informatics in Medicine | Issue 2/2006

Login to get access

Abstract

The surface doses to patients during chest, abdomen and pelvis radiography were measured over a period of 3 years, during which time computed radiography (CR) and digital radiography (DR) systems were introduced to replace film–screen systems. For film–screen and CR the surface doses were measured with thermoluminescent dosimeters. For DR the surface doses were calculated from the dose–area product (DAP) meter readings. Measurements were made for each type of examination and detector type on 10 average-size patients. Measurements were made immediately after the new systems were introduced, and subsequently as adjustments were made to optimize dose and image quality. Published diagnostic reference levels were used as target values in this optimization. Initially, CR doses were the same as or higher than for film–screen, and the doses were lower for DR compared to film–screen. Subsequent clinical experience with the systems led to changes in the technique used for chest examinations both for CR and for DR. For CR, it was possible to change the algorithm and decrease the dose to one quarter of the initial value with acceptable image quality. For DR, it was decided to reduce noise by increasing the dose by a factor of two. No changes were made to abdomen or pelvic imaging techniques for either CR or DR. The final patient surface doses using CR were similar to published diagnostic reference doses; for DR, all patient doses were less than published reference levels.
Literature
1.
go back to reference United Nations Scientific Committee on the Effects of Ionizing Radiation2000Sources and Effects of Ionizing RadiationUnited NationsNew York United Nations Scientific Committee on the Effects of Ionizing Radiation2000Sources and Effects of Ionizing RadiationUnited NationsNew York
2.
go back to reference International Commission on Radiological Protection (ICRP):1996Radiological Protection and Safety in Medicine. ICRP Publication 73. Annals of the ICRP 26, No. 2Pergamon PressOxford International Commission on Radiological Protection (ICRP):1996Radiological Protection and Safety in Medicine. ICRP Publication 73. Annals of the ICRP 26, No. 2Pergamon PressOxford
3.
go back to reference International Atomic Energy Agency (IAEA): International action plan for the radiological protection of patients: Report by the Director General. IAEA, Vienna, 2002, GOV/2002/36-GC(46)/12 International Atomic Energy Agency (IAEA): International action plan for the radiological protection of patients: Report by the Director General. IAEA, Vienna, 2002, GOV/2002/36-GC(46)/12
4.
go back to reference European Commission:1997On health protection of individuals against the dangers of ionising radiation in relation to medical exposure. Council Directive 97/43/EuratomOff J Eur Communities L Legis1802227 European Commission:1997On health protection of individuals against the dangers of ionising radiation in relation to medical exposure. Council Directive 97/43/EuratomOff J Eur Communities L Legis1802227
5.
go back to reference European Commission:1999Guidance on Diagnostic Reference Levels for Medical Exposures. Radiation Protection 109Office for Official Publications of the European CommunitiesLuxembourg European Commission:1999Guidance on Diagnostic Reference Levels for Medical Exposures. Radiation Protection 109Office for Official Publications of the European CommunitiesLuxembourg
6.
go back to reference Aldrich, JE, Andrews, JW 1981Measurement of x-ray exposures using mailed thermoluminescent dosimetersCan Assoc Radiol J32202205 Aldrich, JE, Andrews, JW 1981Measurement of x-ray exposures using mailed thermoluminescent dosimetersCan Assoc Radiol J32202205
7.
go back to reference National Radiological Protection Board (NRPB):1992National Protocol for Patient Dose Measurements in Diagnostic RadiologyChiltonDidcot, Oxford National Radiological Protection Board (NRPB):1992National Protocol for Patient Dose Measurements in Diagnostic RadiologyChiltonDidcot, Oxford
8.
go back to reference Hart, D, Jones, DG, Wall, BF 1994Estimation of Effective Dose in Diagnostic Radiology from Entrance Surface Dose and Dose-Area Product Measurements. NRPB Report R262ChiltonDidcot, Oxford Hart, D, Jones, DG, Wall, BF 1994Estimation of Effective Dose in Diagnostic Radiology from Entrance Surface Dose and Dose-Area Product Measurements. NRPB Report R262ChiltonDidcot, Oxford
9.
go back to reference International Commission on Radiological Protection (ICRP):19911990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann ICRP 21, No. 1–3Pergamon PressOxford International Commission on Radiological Protection (ICRP):19911990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann ICRP 21, No. 1–3Pergamon PressOxford
10.
go back to reference Hart, D, Hillier, MC, Wall, BF June 2002Doses to Patients from Medical X-Ray Examinations in the UK 2000 Review. National Radiological Protection Board Publication NRPB-W14ChiltonDidcot, Oxford Hart, D, Hillier, MC, Wall, BF June 2002Doses to Patients from Medical X-Ray Examinations in the UK 2000 Review. National Radiological Protection Board Publication NRPB-W14ChiltonDidcot, Oxford
12.
go back to reference International Atomic Energy Agency (IAEA):2004Optimization of the Radiological Protection of Patients Undergoing Radiography, Fluoroscopy and Computed Tomography. IAEA-TECDOC-1423IAEAVienna International Atomic Energy Agency (IAEA):2004Optimization of the Radiological Protection of Patients Undergoing Radiography, Fluoroscopy and Computed Tomography. IAEA-TECDOC-1423IAEAVienna
13.
go back to reference Gray, JE, Archer, BR, Butler, PF, et al. 2005Reference values for diagnostic radiology: application and impactRadiology235354358PubMed Gray, JE, Archer, BR, Butler, PF,  et al. 2005Reference values for diagnostic radiology: application and impactRadiology235354358PubMed
14.
go back to reference Conway, BJ, Butler, PF, Duff, JE, et al. 1984Beam quality independent attenuation phantom for estimating patient exposure from x-ray automatic exposure controlled chest examinationsMed Phys11827832PubMedCrossRef Conway, BJ, Butler, PF, Duff, JE,  et al. 1984Beam quality independent attenuation phantom for estimating patient exposure from x-ray automatic exposure controlled chest examinationsMed Phys11827832PubMedCrossRef
15.
go back to reference Sulieman, OH, Stern, SH, Spelic, DC 1999Patient dosimetry activities in the US: the nationwide evaluation of x-ray trends and tissue dose handbooksAppl Radiat Isotopes247249259 Sulieman, OH, Stern, SH, Spelic, DC 1999Patient dosimetry activities in the US: the nationwide evaluation of x-ray trends and tissue dose handbooksAppl Radiat Isotopes247249259
Metadata
Title
Optimization of Dose and Image Quality for Computed Radiography and Digital Radiography
Authors
John E. Aldrich
Emerenciana Duran
Pat Dunlop
John R. Mayo
Publication date
01-06-2006
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 2/2006
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-006-9944-9

Other articles of this Issue 2/2006

Journal of Digital Imaging 2/2006 Go to the issue