Skip to main content
Top
Published in: Journal of Orthopaedics and Traumatology 3/2014

Open Access 01-09-2014 | Original Article

Surgical fixation of displaced midshaft clavicle fractures: elastic intramedullary nailing versus precontoured plating

Authors: Nidhi Narsaria, Ashutosh K. Singh, G. R. Arun, R. R. S. Seth

Published in: Journal of Orthopaedics and Traumatology | Issue 3/2014

Login to get access

Abstract

Background

This prospective comparative study was done to evaluate the effectiveness of implants of different design (titanium elastic intramedullary nail versus anatomical precontoured dynamic compression plate) in treatment of displaced midshaft clavicular fractures.

Materials and methods

Sixty-six patients between 18 and 65 years of age were included in this study. They were randomized in two groups to be treated with either elastic intramedullary nail (EIN) or plate. Clinical and radiological assessments were performed at regular intervals. Outcomes and complications of both groups over 2 years of follow-up time were compared.

Results

Length of incision, operation time, blood loss and duration of hospital stay were significantly less for the EIN group. American Shoulder and Elbow Surgeons (ASES) and Constant Shoulder scores were significantly higher (p < 0.05) in the plating group than the EIN group for the first 2 months but there was no significant difference found between the two groups regarding functional and radiological outcome at the 2-year follow-up. Significantly higher rates of refracture after implant removal (p = 0.045) in the plating group was observed. Infection and revision surgery rates were also higher in the plate group, but this difference was insignificant (p > 0.05).

Conclusions

EIN is a safe, minimally invasive surgical technique with a lower complication rate, faster return to daily activities, excellent cosmetic and comparable functional results, and can be used as an equally effective alternative to plate fixation in displaced midshaft clavicle fractures.

Level of evidence

Level 2.
Literature
1.
go back to reference Robinson CM (1998) Fractures of the clavicle in the adult. Epidemiology and classification. J Bone Joint Surg Br 80:476–484PubMedCrossRef Robinson CM (1998) Fractures of the clavicle in the adult. Epidemiology and classification. J Bone Joint Surg Br 80:476–484PubMedCrossRef
2.
go back to reference Khan LA, Bradnock TJ, Scott C, Robinson CM (2009) Fractures of the clavicle. J Bone Joint Surg (Am) 91:447–460CrossRef Khan LA, Bradnock TJ, Scott C, Robinson CM (2009) Fractures of the clavicle. J Bone Joint Surg (Am) 91:447–460CrossRef
3.
go back to reference Pearson AM, Tosteson ANA, Koval KJ, McKee MD, Cantu RV, Bell JE, Vicente M (2010) Is surgery for displaced, midshaft clavicle fractures in adults cost-effective? Results based on a multicenter randomized, controlled trial. J Orthop Trauma 24:426–433PubMedCrossRef Pearson AM, Tosteson ANA, Koval KJ, McKee MD, Cantu RV, Bell JE, Vicente M (2010) Is surgery for displaced, midshaft clavicle fractures in adults cost-effective? Results based on a multicenter randomized, controlled trial. J Orthop Trauma 24:426–433PubMedCrossRef
4.
go back to reference Nowak J, Mallmin H, Larsson S (2000) The aetiology and epidemiology of clavicular fractures. A prospective study during a two-year period in Uppsala, Sweden. Injury 31:353–358PubMedCrossRef Nowak J, Mallmin H, Larsson S (2000) The aetiology and epidemiology of clavicular fractures. A prospective study during a two-year period in Uppsala, Sweden. Injury 31:353–358PubMedCrossRef
5.
go back to reference Stanley D, Trowbridge EA, Norris SH (1988) The mechanism of clavicular fracture. A clinical and biomechanical analysis. J Bone Joint Surg Br 70:461–464PubMed Stanley D, Trowbridge EA, Norris SH (1988) The mechanism of clavicular fracture. A clinical and biomechanical analysis. J Bone Joint Surg Br 70:461–464PubMed
7.
go back to reference Canadian Orthopaedic Trauma Society (2007) Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am 89:1–10 Canadian Orthopaedic Trauma Society (2007) Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am 89:1–10
8.
go back to reference Hill JM, McGuire MH, Crosby LA (1997) Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 79:537–539PubMedCrossRef Hill JM, McGuire MH, Crosby LA (1997) Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 79:537–539PubMedCrossRef
9.
go back to reference Denard PJ, Koval KJ, Cantu RV, Weinstein JN (2005) Management of midshaft clavicle fractures in adults. Am J Orthop 34:527–536PubMed Denard PJ, Koval KJ, Cantu RV, Weinstein JN (2005) Management of midshaft clavicle fractures in adults. Am J Orthop 34:527–536PubMed
10.
go back to reference Lee YS, Lin CC, Huang CR, Chen CN, Liao WY (2007) Operative treatment of midclavicular fractures in 62 elderly patients: Knowles pin versus plate. Orthopedics 30(11):959–964PubMed Lee YS, Lin CC, Huang CR, Chen CN, Liao WY (2007) Operative treatment of midclavicular fractures in 62 elderly patients: Knowles pin versus plate. Orthopedics 30(11):959–964PubMed
11.
go back to reference Mudd CD, Quigley KJ, Gross LB (2011) Excessive complications of open intramedullary nailing of midshaft clavicle fractures with the Rockwood clavicle pin. Clin Orthop Relat Res 469(12):3364–3370PubMedCentralPubMedCrossRef Mudd CD, Quigley KJ, Gross LB (2011) Excessive complications of open intramedullary nailing of midshaft clavicle fractures with the Rockwood clavicle pin. Clin Orthop Relat Res 469(12):3364–3370PubMedCentralPubMedCrossRef
12.
go back to reference Mueller M, Rangger C, Striepens N, Burger C (2008) Minimally invasive intramedullary nailing of midshaft clavicular fractures using titanium elastic nails. J Trauma 64(6):1528–1534PubMedCrossRef Mueller M, Rangger C, Striepens N, Burger C (2008) Minimally invasive intramedullary nailing of midshaft clavicular fractures using titanium elastic nails. J Trauma 64(6):1528–1534PubMedCrossRef
13.
go back to reference Assobhi JE (2011) Reconstruction plate versus minimal invasive retrograde titanium elastic nail fixation for displaced midclavicular fractures. J Orthop Traumatol 12(4):185–192PubMedCentralPubMedCrossRef Assobhi JE (2011) Reconstruction plate versus minimal invasive retrograde titanium elastic nail fixation for displaced midclavicular fractures. J Orthop Traumatol 12(4):185–192PubMedCentralPubMedCrossRef
14.
go back to reference Wijdicks FJG, Houwert M, Dijkgraaf M, de Lange D, Oosterhuis K, Clevers G, Millet PJ, Verleisdonk EJ (2012) Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison. Int Orthop 36(10):2139–2145PubMedCentralPubMedCrossRef Wijdicks FJG, Houwert M, Dijkgraaf M, de Lange D, Oosterhuis K, Clevers G, Millet PJ, Verleisdonk EJ (2012) Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison. Int Orthop 36(10):2139–2145PubMedCentralPubMedCrossRef
15.
go back to reference Poigenfürst J, Rappold G, Fisher W (1992) Plating of fresh clavicular fractures: results of 122 operations. Injury 23(4):237–241PubMedCrossRef Poigenfürst J, Rappold G, Fisher W (1992) Plating of fresh clavicular fractures: results of 122 operations. Injury 23(4):237–241PubMedCrossRef
16.
go back to reference Jubel A, Andermahr J, Schiffer G, Tsironis K, Rehm KE (2003) Elastic stable intramedullary nailing of midclavicular fractures with a titanium nail. Clin Orthop Relat Res 408:279–285PubMedCrossRef Jubel A, Andermahr J, Schiffer G, Tsironis K, Rehm KE (2003) Elastic stable intramedullary nailing of midclavicular fractures with a titanium nail. Clin Orthop Relat Res 408:279–285PubMedCrossRef
17.
go back to reference Constant CR, Murley AG (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164PubMed Constant CR, Murley AG (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164PubMed
18.
go back to reference Robinson CM, Court-Brown CM, McQueen MM, Wakefield AE (2004) Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture. J Bone Joint Surg 86-A:1359–1365PubMed Robinson CM, Court-Brown CM, McQueen MM, Wakefield AE (2004) Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture. J Bone Joint Surg 86-A:1359–1365PubMed
19.
go back to reference Wild LM, Potter J (2006) Deficits following nonoperative treatment of displaced midshaft clavicular fractures. J Bone Joint Surg 88-A:35–40 Wild LM, Potter J (2006) Deficits following nonoperative treatment of displaced midshaft clavicular fractures. J Bone Joint Surg 88-A:35–40
20.
go back to reference Ali KM, Lucas HK (1978) Plating of fractures of the middle third of the clavicle. Injury 9(4):263–267 Ali KM, Lucas HK (1978) Plating of fractures of the middle third of the clavicle. Injury 9(4):263–267
21.
go back to reference Jeray K (2007) Acute midshaft clavicular fracture. J Am Acad Orthop Surg 15:239–248PubMed Jeray K (2007) Acute midshaft clavicular fracture. J Am Acad Orthop Surg 15:239–248PubMed
22.
go back to reference Kyle RF, Schmidt AH (1995) Open reduction and internal fixation of fractures and nonunions. In: Thompson RC (ed) The shoulder. Raven Press, New York, p 183 Kyle RF, Schmidt AH (1995) Open reduction and internal fixation of fractures and nonunions. In: Thompson RC (ed) The shoulder. Raven Press, New York, p 183
23.
go back to reference Neviaser RJ, Neviaser JS, Neviaser TJ (1975) A simple technique for internal fixation of the clavicle: a long-term evaluation. Clin Orthop 109:103PubMedCrossRef Neviaser RJ, Neviaser JS, Neviaser TJ (1975) A simple technique for internal fixation of the clavicle: a long-term evaluation. Clin Orthop 109:103PubMedCrossRef
24.
go back to reference Ngarmukos C, Parkpian V, Patradul A (1998) Fixation of fractures of the midshaft of the clavicle with Kirschner wires: results in 108 patients. J Bone Joint Surg 80B:106CrossRef Ngarmukos C, Parkpian V, Patradul A (1998) Fixation of fractures of the midshaft of the clavicle with Kirschner wires: results in 108 patients. J Bone Joint Surg 80B:106CrossRef
25.
go back to reference Mullaji AB, Jupiter JB (1994) Low-contact dynamic compression plating of the clavicle. Injury 25:41PubMedCrossRef Mullaji AB, Jupiter JB (1994) Low-contact dynamic compression plating of the clavicle. Injury 25:41PubMedCrossRef
26.
go back to reference Ring D, Jupiter JB, Miller ME, Ada JR (1998) Injuries to the shoulder girdle: part II. Fractures of the clavicle. In: Browner BD, Jupiter JB, Levine AM, Trafton PG (eds) Skeletal trauma, vol 2. WB Saunders, Philadelphia, p 1670 Ring D, Jupiter JB, Miller ME, Ada JR (1998) Injuries to the shoulder girdle: part II. Fractures of the clavicle. In: Browner BD, Jupiter JB, Levine AM, Trafton PG (eds) Skeletal trauma, vol 2. WB Saunders, Philadelphia, p 1670
27.
go back to reference Golish SR, Oliviero JA, Francke EI, Miller MD (2008) A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation. J Orthop Surg Res 16(3):28CrossRef Golish SR, Oliviero JA, Francke EI, Miller MD (2008) A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation. J Orthop Surg Res 16(3):28CrossRef
28.
go back to reference Kloen P, Sorkin AT, Rubel IF, Helfet DL (2002) Anteroinferior plating of midshaft clavicular nonunions. J Orthop Trauma 16:425–430PubMedCrossRef Kloen P, Sorkin AT, Rubel IF, Helfet DL (2002) Anteroinferior plating of midshaft clavicular nonunions. J Orthop Trauma 16:425–430PubMedCrossRef
29.
go back to reference Schwarz N, Hocker K (1992) Osteosynthesis of irreducible fractures of the clavicle with 2.7-mm ASIF plates. J Trauma 33:179–183PubMedCrossRef Schwarz N, Hocker K (1992) Osteosynthesis of irreducible fractures of the clavicle with 2.7-mm ASIF plates. J Trauma 33:179–183PubMedCrossRef
30.
go back to reference Rehm KE, Andermahr J, Jubel A (2005) Intramedullary nailing of midclavicular fractures with an elastic titanium nail. Eur J Traum Emerg Surg 31(4):409–416 Rehm KE, Andermahr J, Jubel A (2005) Intramedullary nailing of midclavicular fractures with an elastic titanium nail. Eur J Traum Emerg Surg 31(4):409–416
31.
go back to reference Böstman O, Manninen M, Pihlajamäki H (1997) Complications of plate fixation in fresh displaced midclavicular fractures. J Trauma 43:778–783PubMedCrossRef Böstman O, Manninen M, Pihlajamäki H (1997) Complications of plate fixation in fresh displaced midclavicular fractures. J Trauma 43:778–783PubMedCrossRef
32.
go back to reference Chen YF, Wei HF, Zhang C, Zeng BF, Zhang CQ, Xue JF et al (2012) Retrospective comparison of titanium elastic nail (TEN) and reconstruction plate repair of displaced midshaft clavicular fractures. J Shoulder Elbow Surg 21:495–501PubMedCrossRef Chen YF, Wei HF, Zhang C, Zeng BF, Zhang CQ, Xue JF et al (2012) Retrospective comparison of titanium elastic nail (TEN) and reconstruction plate repair of displaced midshaft clavicular fractures. J Shoulder Elbow Surg 21:495–501PubMedCrossRef
33.
go back to reference Liu HH, Chang CH, Chia WT, Chen CH, Tarng YW, Wong CY (2010) Comparison of plates versus intramedullary nails for fixation of displaced midshaft clavicular fractures. J Trauma 69(6):E82–E87PubMedCrossRef Liu HH, Chang CH, Chia WT, Chen CH, Tarng YW, Wong CY (2010) Comparison of plates versus intramedullary nails for fixation of displaced midshaft clavicular fractures. J Trauma 69(6):E82–E87PubMedCrossRef
34.
go back to reference Ferran NA, Hodgson P, Vannet N, Williams R, Evans RO (2010) Locked intramedullary fixation vs plating for displaced and shortened mid-shaft clavicle fractures: a randomized clinical trial. J Shoulder Elbow Surg 19:783–789PubMedCrossRef Ferran NA, Hodgson P, Vannet N, Williams R, Evans RO (2010) Locked intramedullary fixation vs plating for displaced and shortened mid-shaft clavicle fractures: a randomized clinical trial. J Shoulder Elbow Surg 19:783–789PubMedCrossRef
35.
go back to reference Böhme J, Bonk A, Bacher GO, Wilharm A, Hoffmann R, Josten C (2010) Current treatment concepts for mid-shaft fractures of the clavicle—results of a prospective multicentre study. Z Orthop Unfall. 149(1):68–76PubMed Böhme J, Bonk A, Bacher GO, Wilharm A, Hoffmann R, Josten C (2010) Current treatment concepts for mid-shaft fractures of the clavicle—results of a prospective multicentre study. Z Orthop Unfall. 149(1):68–76PubMed
36.
go back to reference Thyagarajan DS, Day M, Dent C, Williams R, Evans R (2009) Treatment of mid-shaft clavicle fractures: a comparative study. Int J Shoulder Surg 3(2):23–27PubMedCentralCrossRef Thyagarajan DS, Day M, Dent C, Williams R, Evans R (2009) Treatment of mid-shaft clavicle fractures: a comparative study. Int J Shoulder Surg 3(2):23–27PubMedCentralCrossRef
37.
go back to reference Wu CC, Shih CH, Chen WJ, Tai CL (1998) Treatment of clavicular aseptic nonunion: comparison of plating and intramedullary nailing techniques. J Trauma 45:512–516PubMedCrossRef Wu CC, Shih CH, Chen WJ, Tai CL (1998) Treatment of clavicular aseptic nonunion: comparison of plating and intramedullary nailing techniques. J Trauma 45:512–516PubMedCrossRef
38.
go back to reference Capicotto PN, Heiple KG, Wilbur JH (1994) Midshaft clavicle nonunions treated with intramedullary Steinman pin fixation and onlay bone graft. J Orthop Trauma 8:88PubMedCrossRef Capicotto PN, Heiple KG, Wilbur JH (1994) Midshaft clavicle nonunions treated with intramedullary Steinman pin fixation and onlay bone graft. J Orthop Trauma 8:88PubMedCrossRef
39.
go back to reference Enneking TJ, Hartlief MT, Fontijne WP (1999) Rush pin fixation for midshaft clavicular nonunions: good results in 13/14 cases. Acta Orthop Scand 70:514–516PubMedCrossRef Enneking TJ, Hartlief MT, Fontijne WP (1999) Rush pin fixation for midshaft clavicular nonunions: good results in 13/14 cases. Acta Orthop Scand 70:514–516PubMedCrossRef
40.
go back to reference Schwarz N, Leixnering M (1984) Failures of clavicular intramedullary wire fixation and their causes. Aktuelle Traumatol 14:159–163PubMed Schwarz N, Leixnering M (1984) Failures of clavicular intramedullary wire fixation and their causes. Aktuelle Traumatol 14:159–163PubMed
41.
go back to reference Liu HP, Chang CH, Lin PJ, Chu JJ, Hsieh HC, Chang JP et al (1993) Pulmonary artery perforation after Kirschner wire migration: case report and review of the literature. J Trauma 34:154–156PubMedCrossRef Liu HP, Chang CH, Lin PJ, Chu JJ, Hsieh HC, Chang JP et al (1993) Pulmonary artery perforation after Kirschner wire migration: case report and review of the literature. J Trauma 34:154–156PubMedCrossRef
Metadata
Title
Surgical fixation of displaced midshaft clavicle fractures: elastic intramedullary nailing versus precontoured plating
Authors
Nidhi Narsaria
Ashutosh K. Singh
G. R. Arun
R. R. S. Seth
Publication date
01-09-2014
Publisher
Springer International Publishing
Published in
Journal of Orthopaedics and Traumatology / Issue 3/2014
Print ISSN: 1590-9921
Electronic ISSN: 1590-9999
DOI
https://doi.org/10.1007/s10195-014-0298-7

Other articles of this Issue 3/2014

Journal of Orthopaedics and Traumatology 3/2014 Go to the issue