Abstract

Background

The aim of the present study was to evaluate the recently developed 3D intrastomal ultrasonography in diagnosing stoma-associated complaints and suspected complications after parastomal hernia repair such as peristomal fistula and abscesses.

Methods

3D intrastomal ultrasonography was used to image peristomal tissue in two patients with complaints after parastomal hernia repair performed with IPOM (intraperitoneal onlay mesh). One patient had ulcerative colitis and one Crohn’s disease. Both patients were investigated because of pain and in one case also signs of a subcutaneous abscess.

Results

Intrastomal ultrasonography revealed fistulas connected to the intestinal segment leading to the stoma in both cases. Both cases also showed signs of a fistula descending to the abdominal cavity. In one case, a subcutaneous abscess was identified and in the other a small abscess adjacent to the fistula and the edge of the fascia.

Conclusions

Stoma complaints after surgery for parastomal hernia with implantation of IPOM mesh can be diagnosed using 3D intrastomal ultrasonography. This new 3D technique for imaging intrastomal hernia can be used to complement traditional methods in the detection of stoma-associated abscesses and fistulas with or without foreign material such as mesh.
Literature
1.
go back to reference Gurmu A, Gunnarsson U, Strigård K (2011) Imaging of parastomal hernia using three-dimensional intrastomal ultrasonography. Br J Surg 98:1026–1029PubMedCrossRef Gurmu A, Gunnarsson U, Strigård K (2011) Imaging of parastomal hernia using three-dimensional intrastomal ultrasonography. Br J Surg 98:1026–1029PubMedCrossRef
2.
go back to reference Gurmu A, Matthiessen P, Nilsson S, Påhlman L, Rutegård J, Gunnarsson U (2011) The inter-observer reliability is very low at clinical examination of parastomal hernia. Int J Colorect Dis 26:89–95CrossRef Gurmu A, Matthiessen P, Nilsson S, Påhlman L, Rutegård J, Gunnarsson U (2011) The inter-observer reliability is very low at clinical examination of parastomal hernia. Int J Colorect Dis 26:89–95CrossRef
3.
go back to reference Cingi A, Cakir T, Sever A, Aktan AO (2006) Enterostomy site hernias: a clinical and computerized tomographic evaluation. Dis Colon Rectum 49:1559–1563PubMedCrossRef Cingi A, Cakir T, Sever A, Aktan AO (2006) Enterostomy site hernias: a clinical and computerized tomographic evaluation. Dis Colon Rectum 49:1559–1563PubMedCrossRef
4.
go back to reference Sjödahl RI, Thorelius L, Hallböök OJ (2011) Ultrasonographic findings in patients with peristomal bulging. Scand J Gastroenterol 46:745–749PubMedCrossRef Sjödahl RI, Thorelius L, Hallböök OJ (2011) Ultrasonographic findings in patients with peristomal bulging. Scand J Gastroenterol 46:745–749PubMedCrossRef
5.
go back to reference Sjödahl R, Anderberg B, Bolin T (1988) Parastomal hernia in relation to site of the abdominal wall. Br J Surg 75:339–341PubMedCrossRef Sjödahl R, Anderberg B, Bolin T (1988) Parastomal hernia in relation to site of the abdominal wall. Br J Surg 75:339–341PubMedCrossRef
6.
go back to reference Goligher JC (1985) Surgery of the anus, rectum and colon, 5th edn. Bailliere Tindall, London, pp 703–704 Goligher JC (1985) Surgery of the anus, rectum and colon, 5th edn. Bailliere Tindall, London, pp 703–704
8.
go back to reference Steele S, Lee P, Martin M, Mullenix P, Sullivan E (2003) Is parastomal hernia repair with polypropylene mesh safe? Am J Surg 185:436–440PubMedCrossRef Steele S, Lee P, Martin M, Mullenix P, Sullivan E (2003) Is parastomal hernia repair with polypropylene mesh safe? Am J Surg 185:436–440PubMedCrossRef
9.
go back to reference Toy F, Bailey R, Carey S et al (1998) Prospective, multicenter study of laparoscopic ventral hernioplasty. Preliminary results. Surg Endosc 12:955–959PubMedCrossRef Toy F, Bailey R, Carey S et al (1998) Prospective, multicenter study of laparoscopic ventral hernioplasty. Preliminary results. Surg Endosc 12:955–959PubMedCrossRef
10.
go back to reference Stelzner S, Hellmich G, Ludwig K (2004) Repair of paracolostomy hernias with a prosthetic mesh in the intraperitoneal onlay position: modified Sugarbaker technique. Dis Colon Rectum 47:185–191PubMedCrossRef Stelzner S, Hellmich G, Ludwig K (2004) Repair of paracolostomy hernias with a prosthetic mesh in the intraperitoneal onlay position: modified Sugarbaker technique. Dis Colon Rectum 47:185–191PubMedCrossRef
11.
go back to reference LeBlanc K, Bellanger D, Whitaker J, Hausman M (2005) Laparoscopic parastomal hernia repair. Hernia 9:140–144PubMedCrossRef LeBlanc K, Bellanger D, Whitaker J, Hausman M (2005) Laparoscopic parastomal hernia repair. Hernia 9:140–144PubMedCrossRef
12.
go back to reference Aldridge A, Simson J (2001) Erosion and perforation of colon by synthetic mesh in a recurrent paracolostomy hernia. Hernia 5:110–112PubMedCrossRef Aldridge A, Simson J (2001) Erosion and perforation of colon by synthetic mesh in a recurrent paracolostomy hernia. Hernia 5:110–112PubMedCrossRef
13.
go back to reference Santoro G, Fortling B (2007) The advantages of volume rendering in three-dimensional endosonography of the anorectum. Dis Colon Rectum 50:359–368PubMedCrossRef Santoro G, Fortling B (2007) The advantages of volume rendering in three-dimensional endosonography of the anorectum. Dis Colon Rectum 50:359–368PubMedCrossRef
14.
go back to reference Kim Y, Park Y (2009) Three-dimensional endoanal ultrasonography assessment of an anal fistula with and without H2O2 enhancement. World J Gastroenterol 14:4810–4815CrossRef Kim Y, Park Y (2009) Three-dimensional endoanal ultrasonography assessment of an anal fistula with and without H2O2 enhancement. World J Gastroenterol 14:4810–4815CrossRef
15.
go back to reference El Mouhadi S, Tourabi C, Cazejust J, Azizi L, Menu Y, Arrivé L (2011) CT and MRI features of ileostomies. AJR 196:577–584PubMedCrossRef El Mouhadi S, Tourabi C, Cazejust J, Azizi L, Menu Y, Arrivé L (2011) CT and MRI features of ileostomies. AJR 196:577–584PubMedCrossRef
16.
go back to reference Greenstein A, Dicker A, Meyers S, Aufses A (1983) Periileostomy fistulae in Crohn’s disease. Ann Surg 197:179–182PubMedCrossRef Greenstein A, Dicker A, Meyers S, Aufses A (1983) Periileostomy fistulae in Crohn’s disease. Ann Surg 197:179–182PubMedCrossRef
Metadata
Title
3D intrastomal ultrasonography, an instrument for detecting stoma-related fistula
Authors
U. Gunnarsson
K. Strigård
Publication date
01-06-2012
Publisher
Springer Milan
Published in
Techniques in Coloproctology / Issue 3/2012
Print ISSN: 1123-6337
Electronic ISSN: 1128-045X
DOI
https://doi.org/10.1007/s10151-012-0821-x

Other articles of this Issue 3/2012

Techniques in Coloproctology 3/2012 Go to the issue