Recently, a bioactive glass ceramic (BGC) has been developed for use as intervertebral cages for anterior cervical discectomy and fusion (ACDF). However, the effectiveness and safety of BGC cages remain to be evaluated. We completed a retrospective comparison of the radiological and clinical outcomes of 36 patients (52 levels) who underwent ACDF with a BGC cage and 35 patients (54 levels) using allograft bone. The following variables were compared between the two groups: the visual analog (VAS) neck and arm pain score and the neck disability index (NDI), measured before surgery and 1 year after; the change in Cobb’s angle, between the C2 and C7 vertebrae, the global sagittal angle, and disc height compared from before surgery to 1 year after; and the rate of spinal fusion and cage subsidence at 1 and 2 years after surgery. The VAS and NDI scores were not different between the two groups. Similarly, the spinal fusion rate was not different between the BGC and allograft bone group at 1 year (73% and 87%, respectively; p = 0.07) and 2 years (94% and 91%, respectively; p = 0.54) after surgery. However, the rate of cage subsidence was higher in the allograft bone (43%) than the BGC (19%) group (p = 0.03), as was the rate of instrument-related failure (p = 0.028), with a specifically higher incidence of implant fracture or failure in the allograft bone group (p = 0.025). Overall, our findings indicate that BGC cages provide a feasible and safe alternative to allograft bone for ACDF.
Literature
1.
go back to reference Arvind V, Kim JS, Oermann EK, Kaji D, Cho SK (2018) Predicting surgical complications in adult patients undergoing anterior cervical discectomy and fusion using machine learning. Neurospine 15:329–337PubMedPubMedCentral Arvind V, Kim JS, Oermann EK, Kaji D, Cho SK (2018) Predicting surgical complications in adult patients undergoing anterior cervical discectomy and fusion using machine learning. Neurospine 15:329–337PubMedPubMedCentral
2.
go back to reference Ba Z, Zhao W, Wu D, Shen B, Yu B, Wang Z (2012) Box cages packed with local decompression bone were efficient in anterior cervical discectomy and fusion: five- to 10-year follow-up. Spine (Phila Pa 1976) 37:E1260–E1263 Ba Z, Zhao W, Wu D, Shen B, Yu B, Wang Z (2012) Box cages packed with local decompression bone were efficient in anterior cervical discectomy and fusion: five- to 10-year follow-up. Spine (Phila Pa 1976) 37:E1260–E1263
3.
go back to reference Bartels RH, Donk RD, Feuth T (2006) Subsidence of stand-alone cervical carbon fiber cages. Neurosurgery 58:502–508 discussion 502-508PubMed Bartels RH, Donk RD, Feuth T (2006) Subsidence of stand-alone cervical carbon fiber cages. Neurosurgery 58:502–508 discussion 502-508PubMed
4.
go back to reference Börm W, Seitz K (2004) Use of cervical stand-alone cages. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society 13:474–475 author reply 476 Börm W, Seitz K (2004) Use of cervical stand-alone cages. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society 13:474–475 author reply 476
5.
go back to reference Chen Y, Lu G, Wang B, Li L, Kuang L (2016) A comparison of anterior cervical discectomy and fusion (ACDF) using self-locking stand-alone polyetheretherketone (PEEK) cage with ACDF using cage and plate in the treatment of three-level cervical degenerative spondylopathy: a retrospective study with 2-year follow-up. Eur Spine J 25:2255–2262PubMed Chen Y, Lu G, Wang B, Li L, Kuang L (2016) A comparison of anterior cervical discectomy and fusion (ACDF) using self-locking stand-alone polyetheretherketone (PEEK) cage with ACDF using cage and plate in the treatment of three-level cervical degenerative spondylopathy: a retrospective study with 2-year follow-up. Eur Spine J 25:2255–2262PubMed
6.
go back to reference Chong E, Pelletier MH, Mobbs RJ, Walsh WR (2015) The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review. BMC Musculoskelet Disord 16:99PubMedPubMedCentral Chong E, Pelletier MH, Mobbs RJ, Walsh WR (2015) The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review. BMC Musculoskelet Disord 16:99PubMedPubMedCentral
7.
go back to reference Deora H, Kim S-H, Behari S, Rudrappa S, Rajshekhar V, Zileli M, Parthiban JKBC (2019) Anterior surgical techniques for cervical spondylotic myelopathy: WFNS spine committee recommendations. Neurospine 16:408–420PubMedPubMedCentral Deora H, Kim S-H, Behari S, Rudrappa S, Rajshekhar V, Zileli M, Parthiban JKBC (2019) Anterior surgical techniques for cervical spondylotic myelopathy: WFNS spine committee recommendations. Neurospine 16:408–420PubMedPubMedCentral
8.
go back to reference Diebo BG, Oren JH, Challier V, Lafage R, Ferrero E, Liu S, Vira S, Spiegel MA, Harris BY, Liabaud B, Henry JK, Errico TJ, Schwab FJ, Lafage V (2016) Global sagittal axis: a step toward full-body assessment of sagittal plane deformity in the human body. J Neurosurg Spine 25:494–499PubMed Diebo BG, Oren JH, Challier V, Lafage R, Ferrero E, Liu S, Vira S, Spiegel MA, Harris BY, Liabaud B, Henry JK, Errico TJ, Schwab FJ, Lafage V (2016) Global sagittal axis: a step toward full-body assessment of sagittal plane deformity in the human body. J Neurosurg Spine 25:494–499PubMed
9.
go back to reference Fountas KN, Kapsalaki EZ, Machinis T, Robinson JS (2006) Extrusion of a screw into the gastrointestinal tract after anterior cervical spine plating. J Spinal Disord Tech 19:199–203PubMed Fountas KN, Kapsalaki EZ, Machinis T, Robinson JS (2006) Extrusion of a screw into the gastrointestinal tract after anterior cervical spine plating. J Spinal Disord Tech 19:199–203PubMed
10.
go back to reference Fujibayashi S, Shikata J, Kamiya N, Tanaka C (2000) Missing anterior cervical plate and screws: a case report. Spine (Phila Pa 1976) 25:2258–2261 Fujibayashi S, Shikata J, Kamiya N, Tanaka C (2000) Missing anterior cervical plate and screws: a case report. Spine (Phila Pa 1976) 25:2258–2261
11.
go back to reference Ghanayem AJ, Zdeblick TA (1996) Cervical spine infections. Orthop Clin North Am 27:53–67PubMed Ghanayem AJ, Zdeblick TA (1996) Cervical spine infections. Orthop Clin North Am 27:53–67PubMed
12.
go back to reference Mansfield HE, Jeffrey Canar W, Gerard CS, O'Toole JE (2014) Single-level anterior cervical discectomy and fusion versus minimally invasive posterior cervical foraminotomy for patients with cervical radiculopathy: a cost analysis. Neurosurg Focus 37:E9PubMed Mansfield HE, Jeffrey Canar W, Gerard CS, O'Toole JE (2014) Single-level anterior cervical discectomy and fusion versus minimally invasive posterior cervical foraminotomy for patients with cervical radiculopathy: a cost analysis. Neurosurg Focus 37:E9PubMed
13.
go back to reference Haws BE, Khechen B, Patel DV, Yoo JS, Guntin JA, Cardinal KL, Singh K (2019) Swallowing function following anterior cervical discectomy and fusion with and without anterior plating: a SWAL-QOL (Swallowing-Quality of Life) and Radiographic Assessment. Neurospine 16:601–607PubMedPubMedCentral Haws BE, Khechen B, Patel DV, Yoo JS, Guntin JA, Cardinal KL, Singh K (2019) Swallowing function following anterior cervical discectomy and fusion with and without anterior plating: a SWAL-QOL (Swallowing-Quality of Life) and Radiographic Assessment. Neurospine 16:601–607PubMedPubMedCentral
14.
go back to reference Heidt ST, Louie PK-H, Khan JM, Basques BA, Hirsch B, Varthi A, Paul JC, Goldberg EJ, An HS (2019) Comparing allografts to autografts for maintenance of cervical sagittal parameters and clinical outcomes following anterior cervical discectomy and fusion with anterior cervical plating. Neurospine 16:618–625PubMedPubMedCentral Heidt ST, Louie PK-H, Khan JM, Basques BA, Hirsch B, Varthi A, Paul JC, Goldberg EJ, An HS (2019) Comparing allografts to autografts for maintenance of cervical sagittal parameters and clinical outcomes following anterior cervical discectomy and fusion with anterior cervical plating. Neurospine 16:618–625PubMedPubMedCentral
15.
go back to reference Hollowell JP, Reinartz J, Pintar FA, Morgese V, Maiman DJ (1994) Failure of synthes anterior cervical fixation device by fracture of Morscher screws: a biomechanical study. J Spinal Disord 7:120–125PubMed Hollowell JP, Reinartz J, Pintar FA, Morgese V, Maiman DJ (1994) Failure of synthes anterior cervical fixation device by fracture of Morscher screws: a biomechanical study. J Spinal Disord 7:120–125PubMed
16.
go back to reference Huang W-C, Wu J-C (2019) Preservation versus elimination of segmental motion in anterior cervical spine surgery. Neurospine 16:576–578PubMedPubMedCentral Huang W-C, Wu J-C (2019) Preservation versus elimination of segmental motion in anterior cervical spine surgery. Neurospine 16:576–578PubMedPubMedCentral
17.
go back to reference Hwang C, Bae J-Y, Koo K, Lee JH, Yeom JS, Chang B-S, Lee C-K (2007) A comparative experimental study of allograft and porous hydroxyapatite as bone substitutes. The Journal of The Korean Orthopaedic Association 42 Hwang C, Bae J-Y, Koo K, Lee JH, Yeom JS, Chang B-S, Lee C-K (2007) A comparative experimental study of allograft and porous hydroxyapatite as bone substitutes. The Journal of The Korean Orthopaedic Association 42
18.
go back to reference Jae Hyup L, Ul Oh J, Do Hwan J, Bong Soon C, Choon Ki L (2010) Quantitative comparison of novel CaO-SiO2-P2O5-B2O3 glass-ceramics (BGS-7) with hydroxyapatite as bone graft extender in rabbit ilium. Korean Tissue Engineering and Regenerative Medicine 7:540–547 Jae Hyup L, Ul Oh J, Do Hwan J, Bong Soon C, Choon Ki L (2010) Quantitative comparison of novel CaO-SiO2-P2O5-B2O3 glass-ceramics (BGS-7) with hydroxyapatite as bone graft extender in rabbit ilium. Korean Tissue Engineering and Regenerative Medicine 7:540–547
19.
go back to reference Jain V, Madan A, Thakur M, Thakur A (2018) Functional outcomes of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion: a prospective study. Neurospine 15:368–375PubMedPubMedCentral Jain V, Madan A, Thakur M, Thakur A (2018) Functional outcomes of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion: a prospective study. Neurospine 15:368–375PubMedPubMedCentral
20.
go back to reference Jiya T, Smit T, Deddens J, Mullender M (2009) Posterior lumbar interbody fusion using nonresorbable poly-ether-ether-ketone versus resorbable poly-L-lactide-co-D,L-lactide fusion devices: a prospective, randomized study to assess fusion and clinical outcome. Spine (Phila Pa 1976) 34:233–237 Jiya T, Smit T, Deddens J, Mullender M (2009) Posterior lumbar interbody fusion using nonresorbable poly-ether-ether-ketone versus resorbable poly-L-lactide-co-D,L-lactide fusion devices: a prospective, randomized study to assess fusion and clinical outcome. Spine (Phila Pa 1976) 34:233–237
21.
go back to reference Kim DH, Lee C-H, Ko YS, Yang SH, Kim CH, Park SB, Chung CK (2019) The clinical implications and complications of anterior versus posterior surgery for multilevel cervical ossification of the posterior longitudinal ligament; an updated systematic review and meta-analysis. Neurospine 16:530–541PubMedPubMedCentral Kim DH, Lee C-H, Ko YS, Yang SH, Kim CH, Park SB, Chung CK (2019) The clinical implications and complications of anterior versus posterior surgery for multilevel cervical ossification of the posterior longitudinal ligament; an updated systematic review and meta-analysis. Neurospine 16:530–541PubMedPubMedCentral
22.
go back to reference Kim Y, Lim JY, Yang GH, Seo J-H, Ryu H-S, Kim G (2019) 3D-printed PCL/bioglass (BGS-7) composite scaffolds with high toughness and cell-responses for bone tissue regeneration. J Ind Eng Chem Kim Y, Lim JY, Yang GH, Seo J-H, Ryu H-S, Kim G (2019) 3D-printed PCL/bioglass (BGS-7) composite scaffolds with high toughness and cell-responses for bone tissue regeneration. J Ind Eng Chem
23.
go back to reference Kokubo T, Ito S, Huang ZT, Hayashi T, Sakka S, Kitsugi T, Yamamuro T (1990) Ca,P-rich layer formed on high-strength bioactive glass-ceramic A-W. J Biomed Mater Res 24:331–343PubMed Kokubo T, Ito S, Huang ZT, Hayashi T, Sakka S, Kitsugi T, Yamamuro T (1990) Ca,P-rich layer formed on high-strength bioactive glass-ceramic A-W. J Biomed Mater Res 24:331–343PubMed
24.
go back to reference Koo K, Hwang C, Lee JH, Chang B-S, Lee C-K (2009) Treatment of bone defects in rabbit tibiae using CaO-SiO2-P2O5-B2O3 bioactive ceramics: radiological, biomechanical, and histological evaluation Koo K, Hwang C, Lee JH, Chang B-S, Lee C-K (2009) Treatment of bone defects in rabbit tibiae using CaO-SiO2-P2O5-B2O3 bioactive ceramics: radiological, biomechanical, and histological evaluation
25.
go back to reference Krijnen MR, Mullender MG, Smit TH, Everts V, Wuisman PI (2006) Radiographic, histologic, and chemical evaluation of bioresorbable 70/30 poly-L-lactide-CO-D, L-lactide interbody fusion cages in a goat model. Spine (Phila Pa 1976) 31:1559–1567 Krijnen MR, Mullender MG, Smit TH, Everts V, Wuisman PI (2006) Radiographic, histologic, and chemical evaluation of bioresorbable 70/30 poly-L-lactide-CO-D, L-lactide interbody fusion cages in a goat model. Spine (Phila Pa 1976) 31:1559–1567
26.
go back to reference Kwon OI, Son DW, Lee SW, Song GS (2016) Comparison of radiologic outcomes of different methods in single-level anterior cervical discectomy and fusion. Korean J Spine 13:91–96PubMedPubMedCentral Kwon OI, Son DW, Lee SW, Song GS (2016) Comparison of radiologic outcomes of different methods in single-level anterior cervical discectomy and fusion. Korean J Spine 13:91–96PubMedPubMedCentral
27.
go back to reference Lawrence BD, Jacobs WB, Norvell DC, Hermsmeyer JT, Chapman JR, Brodke DS (2013) Anterior versus posterior approach for treatment of cervical spondylotic myelopathy: a systematic review. Spine (Phila Pa 1976) 38:S173–S182 Lawrence BD, Jacobs WB, Norvell DC, Hermsmeyer JT, Chapman JR, Brodke DS (2013) Anterior versus posterior approach for treatment of cervical spondylotic myelopathy: a systematic review. Spine (Phila Pa 1976) 38:S173–S182
28.
go back to reference Lee JH, Hong KS, Baek HR, Seo JH, Lee KM, Ryu HS, Lee HK (2013) In vivo evaluation of CaO-SiO2-P2O5-B2O3 glass-ceramics coating on Steinman pins. Artif Organs 37:656–662PubMed Lee JH, Hong KS, Baek HR, Seo JH, Lee KM, Ryu HS, Lee HK (2013) In vivo evaluation of CaO-SiO2-P2O5-B2O3 glass-ceramics coating on Steinman pins. Artif Organs 37:656–662PubMed
29.
go back to reference Lee JH, Kong CB, Yang JJ, Shim HJ, Koo KH, Kim J, Lee CK, Chang BS (2016) Comparison of fusion rate and clinical results between CaO-SiO2-P2O5-B2O3 bioactive glass ceramics spacer with titanium cages in posterior lumbar interbody fusion. Spine J 16:1367–1376PubMed Lee JH, Kong CB, Yang JJ, Shim HJ, Koo KH, Kim J, Lee CK, Chang BS (2016) Comparison of fusion rate and clinical results between CaO-SiO2-P2O5-B2O3 bioactive glass ceramics spacer with titanium cages in posterior lumbar interbody fusion. Spine J 16:1367–1376PubMed
30.
go back to reference Lee JH, Ryu HS, Seo JH, Chang BS, Lee CK (2010) A 90-day intravenous administration toxicity study of CaO-SiO2-P2O5-B2O3 glass-ceramics (BGS-7) in rat. Drug Chem Toxicol 33:38–47PubMed Lee JH, Ryu HS, Seo JH, Chang BS, Lee CK (2010) A 90-day intravenous administration toxicity study of CaO-SiO2-P2O5-B2O3 glass-ceramics (BGS-7) in rat. Drug Chem Toxicol 33:38–47PubMed
31.
go back to reference Lee JH, Ryu HS, Seo JH, Lee DY, Chang BS, Lee CK (2014) Negative effect of rapidly resorbing properties of bioactive glass-ceramics as bone graft substitute in a rabbit lumbar fusion model. Clin Orthop Surg 6:87–95PubMedPubMedCentral Lee JH, Ryu HS, Seo JH, Lee DY, Chang BS, Lee CK (2014) Negative effect of rapidly resorbing properties of bioactive glass-ceramics as bone graft substitute in a rabbit lumbar fusion model. Clin Orthop Surg 6:87–95PubMedPubMedCentral
32.
go back to reference Lee YS, Kim YB, Park SW (2014) Risk factors for postoperative subsidence of single-level anterior cervical discectomy and fusion: the significance of the preoperative cervical alignment. Spine (Phila Pa 1976) 39:1280–1287 Lee YS, Kim YB, Park SW (2014) Risk factors for postoperative subsidence of single-level anterior cervical discectomy and fusion: the significance of the preoperative cervical alignment. Spine (Phila Pa 1976) 39:1280–1287
33.
go back to reference Lied B, Roenning PA, Sundseth J, Helseth E (2010) Anterior cervical discectomy with fusion in patients with cervical disc degeneration: a prospective outcome study of 258 patients (181 fused with autologous bone graft and 77 fused with a PEEK cage). BMC Surg 10:10PubMedPubMedCentral Lied B, Roenning PA, Sundseth J, Helseth E (2010) Anterior cervical discectomy with fusion in patients with cervical disc degeneration: a prospective outcome study of 258 patients (181 fused with autologous bone graft and 77 fused with a PEEK cage). BMC Surg 10:10PubMedPubMedCentral
34.
go back to reference Maharaj MM, Phan K, Mobbs RJ (2016) Anterior cervical discectomy and fusion (ACDF) autograft versus graft substitutes: what do patients prefer?-a clinical study. J Spine Surg 2:105–110PubMedPubMedCentral Maharaj MM, Phan K, Mobbs RJ (2016) Anterior cervical discectomy and fusion (ACDF) autograft versus graft substitutes: what do patients prefer?-a clinical study. J Spine Surg 2:105–110PubMedPubMedCentral
35.
go back to reference Miller LE, Block JE (2011) Safety and effectiveness of bone allografts in anterior cervical discectomy and fusion surgery. Spine (Phila Pa 1976) 36:2045–2050 Miller LE, Block JE (2011) Safety and effectiveness of bone allografts in anterior cervical discectomy and fusion surgery. Spine (Phila Pa 1976) 36:2045–2050
36.
go back to reference Northrup BE, Vaccaro AR, Rosen JE, Balderston RA, Cotler JM (1995) Occurrence of infection in anterior cervical fusion for spinal cord injury after tracheostomy. Spine (Phila Pa 1976) 20:2449–2453 Northrup BE, Vaccaro AR, Rosen JE, Balderston RA, Cotler JM (1995) Occurrence of infection in anterior cervical fusion for spinal cord injury after tracheostomy. Spine (Phila Pa 1976) 20:2449–2453
37.
go back to reference Oh HS, Shim CS, Kim JS, Lee SH (2013) Clinical and radiological comparison of femur and fibular allografts for the treatment of cervical degenerative disc diseases. J Korean Neurosurg Soc 53:6–12PubMedPubMedCentral Oh HS, Shim CS, Kim JS, Lee SH (2013) Clinical and radiological comparison of femur and fibular allografts for the treatment of cervical degenerative disc diseases. J Korean Neurosurg Soc 53:6–12PubMedPubMedCentral
38.
go back to reference Ohtsuki C, Kamitakahara M, Miyazaki T (2009) Bioactive ceramic-based materials with designed reactivity for bone tissue regeneration. J R Soc Interface 6(Suppl 3):S349–S360PubMedPubMedCentral Ohtsuki C, Kamitakahara M, Miyazaki T (2009) Bioactive ceramic-based materials with designed reactivity for bone tissue regeneration. J R Soc Interface 6(Suppl 3):S349–S360PubMedPubMedCentral
39.
go back to reference Patel AA, Spiker WR (2008) Update on the diagnosis and treatment of lumbar nonunions. Seminars in Spine Surgery 20:20–26 Patel AA, Spiker WR (2008) Update on the diagnosis and treatment of lumbar nonunions. Seminars in Spine Surgery 20:20–26
40.
go back to reference Pollard CA (1984) Preliminary validity study of the pain disability index. Percept Mot Skills 59:974PubMed Pollard CA (1984) Preliminary validity study of the pain disability index. Percept Mot Skills 59:974PubMed
41.
go back to reference Ramnarain A, Govender S (2008) Fibular allograft and anterior plating for dislocations/fractures of the cervical spine. Indian journal of orthopaedics 42:83–86PubMedPubMedCentral Ramnarain A, Govender S (2008) Fibular allograft and anterior plating for dislocations/fractures of the cervical spine. Indian journal of orthopaedics 42:83–86PubMedPubMedCentral
42.
go back to reference Ryken TC, Heary RF, Matz PG, Anderson PA, Groff MW, Holly LT, Kaiser MG, Mummaneni PV, Choudhri TF, Vresilovic EJ, Resnick DK, Joint Section on Disorders of the S, Peripheral Nerves of the American Association of Neurological S, Congress of Neurological S (2009) Techniques for cervical interbody grafting. J Neurosurg Spine 11:203–220 Ryken TC, Heary RF, Matz PG, Anderson PA, Groff MW, Holly LT, Kaiser MG, Mummaneni PV, Choudhri TF, Vresilovic EJ, Resnick DK, Joint Section on Disorders of the S, Peripheral Nerves of the American Association of Neurological S, Congress of Neurological S (2009) Techniques for cervical interbody grafting. J Neurosurg Spine 11:203–220
43.
go back to reference Scott J, Huskisson EC (1976) Graphic representation of pain. Pain 2:175–184PubMed Scott J, Huskisson EC (1976) Graphic representation of pain. Pain 2:175–184PubMed
44.
go back to reference Seaman S, Kerezoudis P, Bydon M, Torner JC, Hitchon PW (2017) Titanium vs. polyetheretherketone (PEEK) interbody fusion: meta-analysis and review of the literature. Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia 44:23–29 Seaman S, Kerezoudis P, Bydon M, Torner JC, Hitchon PW (2017) Titanium vs. polyetheretherketone (PEEK) interbody fusion: meta-analysis and review of the literature. Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia 44:23–29
45.
go back to reference Shin JJ (2019) Comparison of adjacent segment degeneration, cervical alignment, and clinical outcomes after one- and multilevel anterior cervical discectomy and fusion. Neurospine 16:589–600PubMedPubMedCentral Shin JJ (2019) Comparison of adjacent segment degeneration, cervical alignment, and clinical outcomes after one- and multilevel anterior cervical discectomy and fusion. Neurospine 16:589–600PubMedPubMedCentral
46.
go back to reference Shriver MF, Lewis DJ, Kshettry VR, Rosenbaum BP, Benzel EC, Mroz TE (2017) Dysphagia rates after anterior cervical diskectomy and fusion: a systematic review and meta-analysis. Global spine journal 7:95–103PubMedPubMedCentral Shriver MF, Lewis DJ, Kshettry VR, Rosenbaum BP, Benzel EC, Mroz TE (2017) Dysphagia rates after anterior cervical diskectomy and fusion: a systematic review and meta-analysis. Global spine journal 7:95–103PubMedPubMedCentral
47.
go back to reference Siambanes D, Mather S (1998) Comparison of plain radiographs and CT scans in instrumented posterior lumbar interbody fusion Siambanes D, Mather S (1998) Comparison of plain radiographs and CT scans in instrumented posterior lumbar interbody fusion
48.
go back to reference Smith GW, Robinson RA (1958) The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am 40-A:607–624PubMed Smith GW, Robinson RA (1958) The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am 40-A:607–624PubMed
49.
go back to reference Wilson JRF, Badhiwala JH, Moghaddamjou A, Martin AR, Fehlings MG (2019) Degenerative cervical myelopathy; a review of the latest advances and future directions in management. Neurospine 16:494–505PubMedPubMedCentral Wilson JRF, Badhiwala JH, Moghaddamjou A, Martin AR, Fehlings MG (2019) Degenerative cervical myelopathy; a review of the latest advances and future directions in management. Neurospine 16:494–505PubMedPubMedCentral
50.
go back to reference Yamamuro T, Shikata J, Okumura H, Kitsugi T, Kakutani Y, Matsui T, Kokubo T (1990) Replacement of the lumbar vertebrae of sheep with ceramic prostheses. J Bone Joint Surg Br 72:889–893PubMed Yamamuro T, Shikata J, Okumura H, Kitsugi T, Kakutani Y, Matsui T, Kokubo T (1990) Replacement of the lumbar vertebrae of sheep with ceramic prostheses. J Bone Joint Surg Br 72:889–893PubMed
51.
go back to reference Yan D, Wang Z, Deng S, Li J, Soo C (2011) Anterior corpectomy and reconstruction with titanium mesh cage and dynamic cervical plate for cervical spondylotic myelopathy in elderly osteoporosis patients. Arch Orthop Trauma Surg 131:1369–1374PubMed Yan D, Wang Z, Deng S, Li J, Soo C (2011) Anterior corpectomy and reconstruction with titanium mesh cage and dynamic cervical plate for cervical spondylotic myelopathy in elderly osteoporosis patients. Arch Orthop Trauma Surg 131:1369–1374PubMed
52.
go back to reference Yang JJ, Yu CH, Chang BS, Yeom JS, Lee JH, Lee CK (2011) Subsidence and nonunion after anterior cervical interbody fusion using a stand-alone polyetheretherketone (PEEK) cage. Clin Orthop Surg 3:16–23PubMedPubMedCentral Yang JJ, Yu CH, Chang BS, Yeom JS, Lee JH, Lee CK (2011) Subsidence and nonunion after anterior cervical interbody fusion using a stand-alone polyetheretherketone (PEEK) cage. Clin Orthop Surg 3:16–23PubMedPubMedCentral
53.
go back to reference Yue WM, Brodner W, Highland TR (2005) Long-term results after anterior cervical discectomy and fusion with allograft and plating: a 5- to 11-year radiologic and clinical follow-up study. Spine (Phila Pa 1976) 30:2138–2144 Yue WM, Brodner W, Highland TR (2005) Long-term results after anterior cervical discectomy and fusion with allograft and plating: a 5- to 11-year radiologic and clinical follow-up study. Spine (Phila Pa 1976) 30:2138–2144
Metadata
Title
Comparison of the effectiveness and safety of bioactive glass ceramic to allograft bone for anterior cervical discectomy and fusion with anterior plate fixation
Authors
Hyung Cheol Kim
Jae Keun Oh
Du Su Kim
Jeffrey S. Roh
Tae Woo Kim
Seong Bae An
Hyeong Seok Jeon
Dong Ah Shin
Seong Yi
Keung Nyun Kim
Do Heum Yoon
Yoon Ha
Publication date
01-10-2020
Publisher
Springer Berlin Heidelberg
Published in
Neurosurgical Review / Issue 5/2020
Print ISSN: 0344-5607
Electronic ISSN: 1437-2320
DOI
https://doi.org/10.1007/s10143-019-01225-x

Other articles of this Issue 5/2020

Neurosurgical Review 5/2020 Go to the issue