Abstract

The implantation of a spacer is common practice after ventral discectomy in the cervical spine. Besides bone or bone cement (Palacos, Sulfix, and Allofix), the surgeon has the choice of a variety of factory-made implants (cages). We report on our experience with the Intromed ZWE [Zwischenwirbel-Ersatzsystem (Intervertebral Replacement System)] implant. The ZWE implant (Intromed Medizintechnik GmbH, 15754, Senzig, Germany), made from titanium 6AL 4V, consists of a flat quadrangular body with a large supporting surface on the bottom and top and a central hole. We report the first 100 cases treated with their 1- or 2-year follow-up completed (mean follow-up, 1.7 years). The mean age was 47±9 years (range: 27–73 years). The implantation was performed without filling the central hole. In addition to the clinical investigation of neurological alterations and the range of movement, X-rays were taken, and the clinical result was determined by an independent investigator according to the Odom Scale. After the minimum follow-up of 1 year, 32 patients scored excellent on the Odom scale, 38 patients good, 25 patients satisfactory, and 5 patients bad. In 74 cases, fusion occurred radiologically as bony bridging around the implant. In 21 cases, the cage showed no change and no radiolucency. In five cases, radiolucency around the implant occurred without instability at flexion-extension X-ray views. In CT scans done in two patients with complaints, we confirmed bony bridging inside the centre hole implanted empty. The Intromed-ZWE-System performs well in routine clinical use. Compared to bone or bone cement, the operating time is reduced. The Intromed System offers an easy fusion method for a competitive price.
Literature
1.
go back to reference Bailey RW, Bagley CE (1960) Stabilization of the cervical spine by anterior fusion. J Bone Joint Surg Am 42:565–594PubMed Bailey RW, Bagley CE (1960) Stabilization of the cervical spine by anterior fusion. J Bone Joint Surg Am 42:565–594PubMed
2.
go back to reference Bishop RC, Moore KA, Hadley MN (1996) Anterior cervical interbody fusion using autogeneic and allogeneic bone graft substrate: a prospective comparative analysis. J Neurosurg 85(2):206–210PubMed Bishop RC, Moore KA, Hadley MN (1996) Anterior cervical interbody fusion using autogeneic and allogeneic bone graft substrate: a prospective comparative analysis. J Neurosurg 85(2):206–210PubMed
3.
go back to reference Brooke NS, Rorke AW, King AT, Gullan RW (1997) Preliminary experience of carbon fibre cage prostheses for treatment of cervical spine disorders. Br J Neurosurg 11(3):221–227PubMedCrossRef Brooke NS, Rorke AW, King AT, Gullan RW (1997) Preliminary experience of carbon fibre cage prostheses for treatment of cervical spine disorders. Br J Neurosurg 11(3):221–227PubMedCrossRef
4.
go back to reference Cloward RB (1958) The anterior approach for removal of ruptured cervical disks. J Neurosurg 15:602–617PubMedCrossRef Cloward RB (1958) The anterior approach for removal of ruptured cervical disks. J Neurosurg 15:602–617PubMedCrossRef
5.
go back to reference Dereymaeker A, Mulier J (1958) Nouvelle cure chirurgicale des discopathies cervicales. La méniscotomie par voie ventrale suivre d’arthrodèse par greffe intercorporéale. Rev Neurol (Paris) 99(6):597–616 Dereymaeker A, Mulier J (1958) Nouvelle cure chirurgicale des discopathies cervicales. La méniscotomie par voie ventrale suivre d’arthrodèse par greffe intercorporéale. Rev Neurol (Paris) 99(6):597–616
6.
go back to reference Eysel P, Fünderer S, Rompe JD, Zöllner J (2000) Die Primärstabilität unterschiedlicher Cages zur Fusion an der Halswirbelsäule. Zentralbl Neurochir 61(4):171–176PubMedCrossRef Eysel P, Fünderer S, Rompe JD, Zöllner J (2000) Die Primärstabilität unterschiedlicher Cages zur Fusion an der Halswirbelsäule. Zentralbl Neurochir 61(4):171–176PubMedCrossRef
7.
go back to reference Gilsbach J, Eggert HJ, Best S (1981) Vor- und Nachteile der vorderen zervikalen Bandscheibenoperation ohne Verblockung. Z Orthop 119:600–601 Gilsbach J, Eggert HJ, Best S (1981) Vor- und Nachteile der vorderen zervikalen Bandscheibenoperation ohne Verblockung. Z Orthop 119:600–601
8.
go back to reference Grote W, Kalff R, Roosen K (1991) Die operative Behandlung zervikaler Bandscheibenvorfälle. Zentralbl Neurochir 52(3):101–108PubMed Grote W, Kalff R, Roosen K (1991) Die operative Behandlung zervikaler Bandscheibenvorfälle. Zentralbl Neurochir 52(3):101–108PubMed
9.
go back to reference Grote W, Rottgen P (1967) Die ventrale Fusion bei der zervikalen Osteochondrose und ihre Behandlungsergebnisse. Acta Neurochir (Wien) 16(3):218–240CrossRef Grote W, Rottgen P (1967) Die ventrale Fusion bei der zervikalen Osteochondrose und ihre Behandlungsergebnisse. Acta Neurochir (Wien) 16(3):218–240CrossRef
10.
go back to reference Hilibrand AS, Fye MA, Emery SE, Palumbo MA, Bohlman HH (2001) Impact of smoking on the outcome of anterior cervical arthrodesis with interbody or strut-grafting. J Bone Joint Surg Am 83-A(5):668–673PubMed Hilibrand AS, Fye MA, Emery SE, Palumbo MA, Bohlman HH (2001) Impact of smoking on the outcome of anterior cervical arthrodesis with interbody or strut-grafting. J Bone Joint Surg Am 83-A(5):668–673PubMed
11.
go back to reference Jho HD (1996) Microsurgical anterior cervical foraminotomy for radiculopathy: a new approach to cervical disc herniation. J Neurosurg 84(2):155–160PubMed Jho HD (1996) Microsurgical anterior cervical foraminotomy for radiculopathy: a new approach to cervical disc herniation. J Neurosurg 84(2):155–160PubMed
12.
go back to reference Jho HD (1997) Decompression via microsurgical anterior foraminotomy for cervical spondylotic myelopathy. Technical note. J Neurosurg 86(2):297–302PubMedCrossRef Jho HD (1997) Decompression via microsurgical anterior foraminotomy for cervical spondylotic myelopathy. Technical note. J Neurosurg 86(2):297–302PubMedCrossRef
13.
go back to reference Jung A, Kehr P, Hamid M (1974) Die Unkoforaminotomie bei Läsionen der Arteria vertebralis und der Zervikalnervenwurzeln. Z Orthop Ihre Grenzgeb 112(4):736–740PubMed Jung A, Kehr P, Hamid M (1974) Die Unkoforaminotomie bei Läsionen der Arteria vertebralis und der Zervikalnervenwurzeln. Z Orthop Ihre Grenzgeb 112(4):736–740PubMed
14.
go back to reference Kaden B, Schramm J, Fuhrmann G, Hoffmann CH (1995) Titanium intervertebral disc and instrumentation for fusion in anterior cervical discectomy. Technical note. Neurosurg Rev 18(1):25–29PubMedCrossRef Kaden B, Schramm J, Fuhrmann G, Hoffmann CH (1995) Titanium intervertebral disc and instrumentation for fusion in anterior cervical discectomy. Technical note. Neurosurg Rev 18(1):25–29PubMedCrossRef
15.
go back to reference Kuslich SD, Ulstrom CL, Griffith SL, Ahern JW, Dowdle JD (1998) The Bagby and Kuslich method of lumbar interbody fusion. History, techniques, and 2-year follow-up results of a United States prospective, multicenter trial. Spine 23(11):1267–1278, discussion 1279PubMedCrossRef Kuslich SD, Ulstrom CL, Griffith SL, Ahern JW, Dowdle JD (1998) The Bagby and Kuslich method of lumbar interbody fusion. History, techniques, and 2-year follow-up results of a United States prospective, multicenter trial. Spine 23(11):1267–1278, discussion 1279PubMedCrossRef
16.
go back to reference Louis R (1987) Der ventrale Zugang zur Halswirbelsäule. Orthopade 16(1):37–45PubMed Louis R (1987) Der ventrale Zugang zur Halswirbelsäule. Orthopade 16(1):37–45PubMed
17.
go back to reference Matge G, Leclercq TA (2000) Rationale for interbody fusion with threaded titanium cages at cervical and lumbar levels. Results on 357 cases. Acta Neurochir (Wien) 142(4):425–433CrossRef Matge G, Leclercq TA (2000) Rationale for interbody fusion with threaded titanium cages at cervical and lumbar levels. Results on 357 cases. Acta Neurochir (Wien) 142(4):425–433CrossRef
18.
go back to reference Mirovsky Y, Neuwirth MG (2000) Comparison between the outer table and intracortical methods of obtaining autogenous bone graft from the iliac crest. Spine 25(13):1722–1725PubMedCrossRef Mirovsky Y, Neuwirth MG (2000) Comparison between the outer table and intracortical methods of obtaining autogenous bone graft from the iliac crest. Spine 25(13):1722–1725PubMedCrossRef
19.
go back to reference Moreland DB, Asch HL, Clabeaux DE, Castiglia GJ, Czajka GA, Lewis PJ, Egnatchik JG, Cappuccino A, Huynh L (2004) Anterior cervical discectomy and fusion with implantable titanium cage: initial impressions, patient outcomes and comparison to fusion with allograft. Spine J 4(2):184–191PubMedCrossRef Moreland DB, Asch HL, Clabeaux DE, Castiglia GJ, Czajka GA, Lewis PJ, Egnatchik JG, Cappuccino A, Huynh L (2004) Anterior cervical discectomy and fusion with implantable titanium cage: initial impressions, patient outcomes and comparison to fusion with allograft. Spine J 4(2):184–191PubMedCrossRef
20.
go back to reference Odom GL, Finney W, Woodhall B, Durham NC (1958) Cervical disk lesions. JAMA 166:23–28 Odom GL, Finney W, Woodhall B, Durham NC (1958) Cervical disk lesions. JAMA 166:23–28
21.
go back to reference Robinson RA, Smith G (1955) Anterolateral cervical disk removal and interbody fusion for cervical disk syndrome. Bull Johns Hopkins Hosp 96:223–224 Robinson RA, Smith G (1955) Anterolateral cervical disk removal and interbody fusion for cervical disk syndrome. Bull Johns Hopkins Hosp 96:223–224
22.
go back to reference Schröder J, Wassmann H (2002) Polymethylmethacrylate (PMMA) in der Halsbandscheibenchirurgie-gegenwärtige Situation in Deutschland. [Polymethylmethacrylate (PMMA) in the anterior cervical spine surgery: current situation in Germany]. Zentralbl Neurochir 63(2):33–36 Schröder J, Wassmann H (2002) Polymethylmethacrylate (PMMA) in der Halsbandscheibenchirurgie-gegenwärtige Situation in Deutschland. [Polymethylmethacrylate (PMMA) in the anterior cervical spine surgery: current situation in Germany]. Zentralbl Neurochir 63(2):33–36
23.
go back to reference Southwick WO, Robinson RA (1957) Surgical approaches to the vertebral bodies in the cervical and lumbar regions. J Bone Joint Surg Am 39-A:631–643PubMed Southwick WO, Robinson RA (1957) Surgical approaches to the vertebral bodies in the cervical and lumbar regions. J Bone Joint Surg Am 39-A:631–643PubMed
24.
go back to reference Thome C, Leheta O, Krauss JK, Zevgaridis D (2006) A prospective randomized comparison of rectangular titanium cage fusion and iliac crest autograft fusion in patients undergoing anterior cervical discectomy. J Neurosurg Spine 4(1):1–9PubMed Thome C, Leheta O, Krauss JK, Zevgaridis D (2006) A prospective randomized comparison of rectangular titanium cage fusion and iliac crest autograft fusion in patients undergoing anterior cervical discectomy. J Neurosurg Spine 4(1):1–9PubMed
25.
go back to reference van den Bent MJ, Oosting J, Wouda EJ, van Acker EH, Ansink BJ, Braakman R (1996) Anterior cervical discectomy with or without fusion with acrylate. A randomized trial. Spine 21(7):834–839, discussion 840PubMedCrossRef van den Bent MJ, Oosting J, Wouda EJ, van Acker EH, Ansink BJ, Braakman R (1996) Anterior cervical discectomy with or without fusion with acrylate. A randomized trial. Spine 21(7):834–839, discussion 840PubMedCrossRef
26.
Metadata
Title
Anterior cervical spinal fusion with the Intromed ZWE System: preliminary experience
Authors
Johannes Schröder
Florian Grosse-Dresselhaus
Christoph Schul
Hansdetlef Wassmann
Publication date
01-01-2007
Publisher
Springer-Verlag
Published in
Neurosurgical Review / Issue 1/2007
Print ISSN: 0344-5607
Electronic ISSN: 1437-2320
DOI
https://doi.org/10.1007/s10143-006-0043-7

Other articles of this Issue 1/2007

Neurosurgical Review 1/2007 Go to the issue