Skip to main content
Top
Published in: Emergency Radiology 2/2017

01-04-2017 | Original Article

The RADCAT-3 system for closing the loop on important non-urgent radiology findings: a multidisciplinary system-wide approach

Authors: Elizabeth H. Dibble, David W. Swenson, Cynthia Cobb, Timothy J. Paul, Andrew E. Karn, David C. Portelli, Jonathan S. Movson

Published in: Emergency Radiology | Issue 2/2017

Login to get access

Abstract

The goal of this project was to create a system that was easy for radiologists to use and that could reliably identify, communicate, and track communication of important but non-urgent radiology findings to providers and patients. Prior to 2012, our workflow for communicating important non-urgent diagnostic imaging results was cumbersome, rarely used by our radiologists, and resulted in delays in report turnaround time. In 2012, we developed a new system to communicate important non-urgent findings (the RADiology CATegorization 3 (RADCAT-3) system) that was easy for radiologists to use and documented communication of results in the electronic medical record. To evaluate the performance of the new system, we reviewed our radiology reports before (June 2011–June 2012) and after (June 2012–June 2014) the implementation of the new system to compare utilization by the radiologists and success in communicating these findings. During the 12 months prior to implementation, 250 radiology reports (0.06 % of all reports) entered our workflow for communicating important non-urgent findings. One-hundred percent were successfully communicated. During the 24 months after implementation, 13,158 radiology reports (1.4 % of all reports) entered our new RADCAT-3 workflow (3995 (0.8 % of all reports) during year 1 and 9163 (1.9 % of all reports) during year 2). 99.7 % of those reports were successfully communicated. We created a reliable system to ensure communication of important but non-urgent findings with providers and/or patients and to document that communication in the electronic medical record. The rapid adoption of the new system by radiologists suggests that they found it easy to use and had confidence in its integrity. This system has the potential to improve patient care by improving the likelihood of appropriate follow-up for important non-urgent findings that could become life threatening.
Literature
1.
go back to reference Dang PA, Kalra MK, Blake MA et al (2008) Natural language processing using online analytic processing for assessing recommendations in radiology reports. J Am Coll Radiol 5:197–204CrossRefPubMed Dang PA, Kalra MK, Blake MA et al (2008) Natural language processing using online analytic processing for assessing recommendations in radiology reports. J Am Coll Radiol 5:197–204CrossRefPubMed
2.
go back to reference Sistrom CL, Dreyer KJ, Dang PP et al (2009) Recommendations for additional imaging in radiology reports: multifactorial analysis of 5.9 million examinations. Radiology 253:453–461CrossRefPubMed Sistrom CL, Dreyer KJ, Dang PP et al (2009) Recommendations for additional imaging in radiology reports: multifactorial analysis of 5.9 million examinations. Radiology 253:453–461CrossRefPubMed
3.
go back to reference Gunn AJ, Sahani DV, Bennett SE, Choy G (2013) Recent measures to improve radiology reporting: perspectives from primary care physicians. J Am Coll Radiol 10:122–127CrossRefPubMed Gunn AJ, Sahani DV, Bennett SE, Choy G (2013) Recent measures to improve radiology reporting: perspectives from primary care physicians. J Am Coll Radiol 10:122–127CrossRefPubMed
4.
go back to reference Little BP, Gilman MD, Humphrey KL et al (2014) Outcome of recommendations for radiographic follow-up of pneumonia on outpatient chest radiography. AJR Am J Roentgenol 202:54–59CrossRefPubMed Little BP, Gilman MD, Humphrey KL et al (2014) Outcome of recommendations for radiographic follow-up of pneumonia on outpatient chest radiography. AJR Am J Roentgenol 202:54–59CrossRefPubMed
5.
go back to reference Harvey HB, Gilman MD, Wu CC et al (2015) Diagnostic yield of recommendations for chest CT examination prompted by outpatient chest radiographic findings. Radiology 275:262–271CrossRefPubMed Harvey HB, Gilman MD, Wu CC et al (2015) Diagnostic yield of recommendations for chest CT examination prompted by outpatient chest radiographic findings. Radiology 275:262–271CrossRefPubMed
6.
go back to reference Baumgarten DA, Nelson RC (1997) Outcome of examinations self-referred as a result of spiral CT of the abdomen. Acad Radiol 4:802–805CrossRefPubMed Baumgarten DA, Nelson RC (1997) Outcome of examinations self-referred as a result of spiral CT of the abdomen. Acad Radiol 4:802–805CrossRefPubMed
7.
go back to reference Benjamin MS, Drucker EA, McLoud TC, Shepard JA (2003) Small pulmonary nodules: detection at chest CT and outcome. Radiology 226:489–493CrossRefPubMed Benjamin MS, Drucker EA, McLoud TC, Shepard JA (2003) Small pulmonary nodules: detection at chest CT and outcome. Radiology 226:489–493CrossRefPubMed
8.
go back to reference You JJ, Laupacis A, Newman A, Bell CM (2010) Non-adherence to recommendations for further testing after outpatient CT and MRI. Am J Med 123:557 e551–557 e558CrossRef You JJ, Laupacis A, Newman A, Bell CM (2010) Non-adherence to recommendations for further testing after outpatient CT and MRI. Am J Med 123:557 e551–557 e558CrossRef
9.
go back to reference Blagev DP, Lloyd JF, Conner K et al (2014) Follow-up of incidental pulmonary nodules and the radiology report. J Am Coll Radiol 11:378–383CrossRefPubMed Blagev DP, Lloyd JF, Conner K et al (2014) Follow-up of incidental pulmonary nodules and the radiology report. J Am Coll Radiol 11:378–383CrossRefPubMed
10.
go back to reference Al-Mutairi A, Meyer AN, Chang P, Singh H (2015) Lack of timely follow-up of abnormal imaging results and radiologists’ recommendations. J Am Coll Radiol 12:385–389CrossRefPubMed Al-Mutairi A, Meyer AN, Chang P, Singh H (2015) Lack of timely follow-up of abnormal imaging results and radiologists’ recommendations. J Am Coll Radiol 12:385–389CrossRefPubMed
11.
go back to reference Berlin L (2002) Communicating findings of radiologic examinations: whither goest the radiologist’s duty? AJR Am J Roentgenol 178:809–815CrossRefPubMed Berlin L (2002) Communicating findings of radiologic examinations: whither goest the radiologist’s duty? AJR Am J Roentgenol 178:809–815CrossRefPubMed
12.
go back to reference Poon EG, Gandhi TK, Sequist TD, Murff HJ, Karson AS, Bates DW (2004) “I wish I had seen this test result earlier!”: dissatisfaction with test result management systems in primary care. Arch Intern Med 164:2223–2228CrossRefPubMed Poon EG, Gandhi TK, Sequist TD, Murff HJ, Karson AS, Bates DW (2004) “I wish I had seen this test result earlier!”: dissatisfaction with test result management systems in primary care. Arch Intern Med 164:2223–2228CrossRefPubMed
13.
go back to reference Harvey HB, Tomov E, Babayan A, et al. (2015) Radiology malpractice claims in the United States from 2008 to 2012: characteristics and implications. J Am Coll Radiol Harvey HB, Tomov E, Babayan A, et al. (2015) Radiology malpractice claims in the United States from 2008 to 2012: characteristics and implications. J Am Coll Radiol
14.
go back to reference Towbin AJ, Hall S, Moskovitz J, Johnson ND, Donnelly LF (2011) Creating a comprehensive customer service program to help convey critical and acute results of radiology studies. AJR Am J Roentgenol 196:W48–W51CrossRefPubMed Towbin AJ, Hall S, Moskovitz J, Johnson ND, Donnelly LF (2011) Creating a comprehensive customer service program to help convey critical and acute results of radiology studies. AJR Am J Roentgenol 196:W48–W51CrossRefPubMed
15.
go back to reference O'Connor SD, Dalal AK, Sahni VA, Lacson R, Khorasani R (2015) Does integrating nonurgent, clinically significant radiology alerts within the electronic health record impact closed-loop communication and follow-up? J Am Med Inform Assoc O'Connor SD, Dalal AK, Sahni VA, Lacson R, Khorasani R (2015) Does integrating nonurgent, clinically significant radiology alerts within the electronic health record impact closed-loop communication and follow-up? J Am Med Inform Assoc
16.
go back to reference Singh H, Thomas EJ, Mani S et al (2009) Timely follow-up of abnormal diagnostic imaging test results in an outpatient setting: are electronic medical records achieving their potential? Arch Intern Med 169:1578–1586PubMedPubMedCentral Singh H, Thomas EJ, Mani S et al (2009) Timely follow-up of abnormal diagnostic imaging test results in an outpatient setting: are electronic medical records achieving their potential? Arch Intern Med 169:1578–1586PubMedPubMedCentral
17.
go back to reference Eisenberg RL, Yamada K, Yam CS, Spirn PW, Kruskal JB (2010) Electronic messaging system for communicating important, but nonemergent, abnormal imaging results. Radiology 257:724–731CrossRefPubMed Eisenberg RL, Yamada K, Yam CS, Spirn PW, Kruskal JB (2010) Electronic messaging system for communicating important, but nonemergent, abnormal imaging results. Radiology 257:724–731CrossRefPubMed
18.
go back to reference Choksi VR, Marn CS, Bell Y, Carlos R (2006) Efficiency of a semiautomated coding and review process for notification of critical findings in diagnostic imaging. AJR Am J Roentgenol 186:933–936CrossRefPubMed Choksi VR, Marn CS, Bell Y, Carlos R (2006) Efficiency of a semiautomated coding and review process for notification of critical findings in diagnostic imaging. AJR Am J Roentgenol 186:933–936CrossRefPubMed
19.
go back to reference D’Orsi CJ, Sickles EA, Mendelson E.B, Morris E.A., et al (2013) ACR BI-RADS® Atlas, breast imaging reporting and data system. Reston, VA: American College of Radiology D’Orsi CJ, Sickles EA, Mendelson E.B, Morris E.A., et al (2013) ACR BI-RADS® Atlas, breast imaging reporting and data system. Reston, VA: American College of Radiology
20.
go back to reference Lucey LL, Kushner DC, American College of R (2010) The ACR guideline on communication: to be or not to be, that is the question. J Am Coll Radiol 7:109–114CrossRefPubMed Lucey LL, Kushner DC, American College of R (2010) The ACR guideline on communication: to be or not to be, that is the question. J Am Coll Radiol 7:109–114CrossRefPubMed
22.
go back to reference Dutta S, Long WJ, Brown DF, Reisner AT (2013) Automated detection using natural language processing of radiologists recommendations for additional imaging of incidental findings. Ann Emerg Med 62:162–169CrossRefPubMed Dutta S, Long WJ, Brown DF, Reisner AT (2013) Automated detection using natural language processing of radiologists recommendations for additional imaging of incidental findings. Ann Emerg Med 62:162–169CrossRefPubMed
23.
go back to reference Sloan CE, Chadalavada SC, Cook TS, Langlotz CP, Schnall MD, Zafar HM (2014) Assessment of follow-up completeness and notification preferences for imaging findings of possible cancer: what happens after radiologists submit their reports? Acad Radiol 21:1579–1586CrossRefPubMedPubMedCentral Sloan CE, Chadalavada SC, Cook TS, Langlotz CP, Schnall MD, Zafar HM (2014) Assessment of follow-up completeness and notification preferences for imaging findings of possible cancer: what happens after radiologists submit their reports? Acad Radiol 21:1579–1586CrossRefPubMedPubMedCentral
24.
go back to reference Singh H, Wilson L, Petersen LA et al (2009) Improving follow-up of abnormal cancer screens using electronic health records: trust but verify test result communication. BMC Med Inform Decis Mak 9:49CrossRefPubMedPubMedCentral Singh H, Wilson L, Petersen LA et al (2009) Improving follow-up of abnormal cancer screens using electronic health records: trust but verify test result communication. BMC Med Inform Decis Mak 9:49CrossRefPubMedPubMedCentral
25.
go back to reference Mangano MD, Rahman A, Choy G, Sahani DV, Boland GW, Gunn AJ (2014) Radiologists’ role in the communication of imaging examination results to patients: perceptions and preferences of patients. AJR Am J Roentgenol 203:1034–1039CrossRefPubMed Mangano MD, Rahman A, Choy G, Sahani DV, Boland GW, Gunn AJ (2014) Radiologists’ role in the communication of imaging examination results to patients: perceptions and preferences of patients. AJR Am J Roentgenol 203:1034–1039CrossRefPubMed
26.
go back to reference Amber I, Fiester A (2013) Communicating findings: a justification and framework for direct radiologic disclosure to patients. AJR Am J Roentgenol 200:586–591CrossRefPubMed Amber I, Fiester A (2013) Communicating findings: a justification and framework for direct radiologic disclosure to patients. AJR Am J Roentgenol 200:586–591CrossRefPubMed
27.
go back to reference Larson PA, Berland LL, Griffith B, Kahn CE Jr, Liebscher LA (2014) Actionable findings and the role of IT support: report of the ACR Actionable Reporting Work Group. J Am Coll Radiol 11:552–558CrossRefPubMed Larson PA, Berland LL, Griffith B, Kahn CE Jr, Liebscher LA (2014) Actionable findings and the role of IT support: report of the ACR Actionable Reporting Work Group. J Am Coll Radiol 11:552–558CrossRefPubMed
28.
go back to reference Harvey HB, Wu CC, Gilman MD et al (2015) Correlation of the strength of recommendations for additional imaging to adherence rate and diagnostic yield. J Am Coll Radiol 12:1016–1022CrossRefPubMed Harvey HB, Wu CC, Gilman MD et al (2015) Correlation of the strength of recommendations for additional imaging to adherence rate and diagnostic yield. J Am Coll Radiol 12:1016–1022CrossRefPubMed
29.
go back to reference Smith M, Murphy D, Laxmisan A et al (2013) Developing software to “track and catch” missed follow-up of abnormal test results in a complex sociotechnical environment. Appl Clin Inform 4:359–375CrossRefPubMedPubMedCentral Smith M, Murphy D, Laxmisan A et al (2013) Developing software to “track and catch” missed follow-up of abnormal test results in a complex sociotechnical environment. Appl Clin Inform 4:359–375CrossRefPubMedPubMedCentral
30.
go back to reference Poon EG, Wang SJ, Gandhi TK, Bates DW, Kuperman GJ (2003) Design and implementation of a comprehensive outpatient results manager. J Biomed Inform 36:80–91CrossRefPubMed Poon EG, Wang SJ, Gandhi TK, Bates DW, Kuperman GJ (2003) Design and implementation of a comprehensive outpatient results manager. J Biomed Inform 36:80–91CrossRefPubMed
31.
go back to reference Grant RW, Wald JS, Poon EG et al (2006) Design and implementation of a web-based patient portal linked to an ambulatory care electronic health record: patient gateway for diabetes collaborative care. Diabetes Technol Ther 8:576–586CrossRefPubMed Grant RW, Wald JS, Poon EG et al (2006) Design and implementation of a web-based patient portal linked to an ambulatory care electronic health record: patient gateway for diabetes collaborative care. Diabetes Technol Ther 8:576–586CrossRefPubMed
32.
go back to reference Murphy DR, Laxmisan A, Reis BA et al (2014) Electronic health record-based triggers to detect potential delays in cancer diagnosis. BMJ Qual Saf 23:8–16CrossRefPubMed Murphy DR, Laxmisan A, Reis BA et al (2014) Electronic health record-based triggers to detect potential delays in cancer diagnosis. BMJ Qual Saf 23:8–16CrossRefPubMed
Metadata
Title
The RADCAT-3 system for closing the loop on important non-urgent radiology findings: a multidisciplinary system-wide approach
Authors
Elizabeth H. Dibble
David W. Swenson
Cynthia Cobb
Timothy J. Paul
Andrew E. Karn
David C. Portelli
Jonathan S. Movson
Publication date
01-04-2017
Publisher
Springer Berlin Heidelberg
Published in
Emergency Radiology / Issue 2/2017
Print ISSN: 1070-3004
Electronic ISSN: 1438-1435
DOI
https://doi.org/10.1007/s10140-016-1452-8

Other articles of this Issue 2/2017

Emergency Radiology 2/2017 Go to the issue