Published in: Emergency Radiology 1/2003

01-04-2003 | Original Article

Report on a new type of trauma full-body digital X-ray machine

Authors: S. Beningfield, H. Potgieter, A. Nicol, S. van As, G. Bowie, E. Hering, E. Lätti

Published in: Emergency Radiology | Issue 1/2003

Login to get access

Abstract

The purpose of this study was to evaluate the diagnostic equivalence, radiation dose, clinical usefulness and radiographic aspects of a low-dose, full-body digital X-ray machine in a busy trauma unit. A digital trauma X-ray machine known as "LODOX" was compared with conventional radiography between June 1999 and November 2001 in the Groote Schuur Hospital Trauma Unit, Cape Town. Digital images of a variety of body regions commonly imaged in trauma were compared for diagnostic image quality in a number of categories with equivalent conventional radiographs. A seven-point equivalence scoring system ranging from much inferior (−3) through equivalent (0) to much superior (+3) was used in each category. Radiation dose was recorded and compared with that in conventional measurements. Turnaround times of patients undergoing digital and conventional X-rays were evaluated. Clinical and radiographic issues were assessed by staff feedback. The digital images when compared with conventional film had an overall mean equivalence score of −0.429, with a standard deviation (SD) of 0.77. The best digital performance was in the mediastinum (mean 0.346, SD 0.49) and the weakest was for bony detail (mean −0.654, SD 0.81). Relative digital radiation dose compared to conventional varied from 72% (chest) to 2% (pelvis), with a simple average of 6%. Radiographic points included full-body imaging capability and differing positioning, penetration, workflow and practicality considerations. The digital images required overall patient times of 5–6 min, compared with 8–48 min for conventional X-rays. New installations are under way, and computed tomography and angiography applications are being explored. FDA approval is awaited. Projected cost is similar to that of flat-panel digital units. This digital unit was felt to be diagnostically substantially equivalent to conventional radiographs, with low-dose full-body imaging, improved workflow, digital technology and long-term cost benefits as potentially favourable contributions to trauma imaging.
Literature
1.
go back to reference Beningfield SJ, Potgieter JH, Bautz P, Shackleton M, Hering E, de Jager G, Bowie G, Marshall M, Cox G, Pagliari G, Coetzee N (1999) Evaluation of a new type of direct digital radiography machine. S Afr Med J 89:1182–1188PubMed Beningfield SJ, Potgieter JH, Bautz P, Shackleton M, Hering E, de Jager G, Bowie G, Marshall M, Cox G, Pagliari G, Coetzee N (1999) Evaluation of a new type of direct digital radiography machine. S Afr Med J 89:1182–1188PubMed
2.
go back to reference Huda W, Scalzetti EM, Geiger R, Roskopf ML (2001) Clinical performance of a commercial prototype flat-panel digital detector for general radiography. Medical Imaging, The International Society for Optical Engineering, San Diego, 17–23 February 2001 Huda W, Scalzetti EM, Geiger R, Roskopf ML (2001) Clinical performance of a commercial prototype flat-panel digital detector for general radiography. Medical Imaging, The International Society for Optical Engineering, San Diego, 17–23 February 2001
3.
go back to reference van As AB, Beningfield SJ, Vaughan CL, Potgieter JH (2000) Trauma assessment in the third millennium; the LODOX imaging device. 4th European Congress, Trauma & Emergency Surgery, European Association of Trauma and Emergency Surgery, Pisa, 16–20 April 2000 van As AB, Beningfield SJ, Vaughan CL, Potgieter JH (2000) Trauma assessment in the third millennium; the LODOX imaging device. 4th European Congress, Trauma & Emergency Surgery, European Association of Trauma and Emergency Surgery, Pisa, 16–20 April 2000
4.
go back to reference Gray JE, Karsell PR, Becker GP, Gehring DG (1984) Total digital radiology: is it feasible? Or desirable? Am J Roentgenol 143:1345–1349 Gray JE, Karsell PR, Becker GP, Gehring DG (1984) Total digital radiology: is it feasible? Or desirable? Am J Roentgenol 143:1345–1349
5.
go back to reference Curtis DJ, Ayella RJ, Whitley J, Moser RP, Rugh KS (1979) Digital radiology in trauma using small-dose exposure. Radiology 132:587–591PubMed Curtis DJ, Ayella RJ, Whitley J, Moser RP, Rugh KS (1979) Digital radiology in trauma using small-dose exposure. Radiology 132:587–591PubMed
6.
go back to reference Tesic MM, Sones RA, Morgan DR (1984) Single-slit digital radiography: some practical considerations. Am J Roentgenol 142:697–702 Tesic MM, Sones RA, Morgan DR (1984) Single-slit digital radiography: some practical considerations. Am J Roentgenol 142:697–702
7.
go back to reference Slasky BS, Sashin D, Horton JA, Sternglass EJ, Bron KM, Deutsch M, Herron JM, Kennedy WH, Boyer JW, Girdany BR, Skinner SR, Simpson RW, Hoy RJ, Feist JH (1987) Digital radiography of the chest by self-scanning linear diode arrays. Acta Radiol 28:461–466PubMed Slasky BS, Sashin D, Horton JA, Sternglass EJ, Bron KM, Deutsch M, Herron JM, Kennedy WH, Boyer JW, Girdany BR, Skinner SR, Simpson RW, Hoy RJ, Feist JH (1987) Digital radiography of the chest by self-scanning linear diode arrays. Acta Radiol 28:461–466PubMed
8.
go back to reference Smathers RL, Brody WR (1985) Digital radiography: current and future trends. Br J Radiol 58:285–307PubMed Smathers RL, Brody WR (1985) Digital radiography: current and future trends. Br J Radiol 58:285–307PubMed
9.
go back to reference Kushner DC, Cleveland RH, Herman TE, Zaleske DJ, Ehrlich MG, Correia JA (1986) Radiation dose reduction in the evaluation of scoliosis: an application of digital radiography. Radiology 161:175–181PubMed Kushner DC, Cleveland RH, Herman TE, Zaleske DJ, Ehrlich MG, Correia JA (1986) Radiation dose reduction in the evaluation of scoliosis: an application of digital radiography. Radiology 161:175–181PubMed
10.
go back to reference Kushner DC, Cleveland RH, Herman TE, McLoud TC, Waltman AC, Shepard JA, Dedrick CG, Kopans DB, Greene RE (1987) Low-dose flying spot digital radiography of the chest: sensitivity studies. Radiology 163:685–688PubMed Kushner DC, Cleveland RH, Herman TE, McLoud TC, Waltman AC, Shepard JA, Dedrick CG, Kopans DB, Greene RE (1987) Low-dose flying spot digital radiography of the chest: sensitivity studies. Radiology 163:685–688PubMed
11.
go back to reference Sones RA, Lauro KL, Cattell CL (1990) A detector for scanned projection radiography. Radiology 175:553–559PubMed Sones RA, Lauro KL, Cattell CL (1990) A detector for scanned projection radiography. Radiology 175:553–559PubMed
12.
go back to reference Vandemark RM, Fay ME, Porter FR, Johnson GA (1997) Digital image-intensifier radiography at a level I trauma center. Am J Roentgenol 168:944–946 Vandemark RM, Fay ME, Porter FR, Johnson GA (1997) Digital image-intensifier radiography at a level I trauma center. Am J Roentgenol 168:944–946
13.
go back to reference Elam EA, Rehm K, Hillman BJ, Maloney K, Fajardo LL, McNeill K (1992) Efficacy of digital radiography for the detection of pneumothorax: comparison with conventional chest radiography. Am J Roentgenol 158:509–514 Elam EA, Rehm K, Hillman BJ, Maloney K, Fajardo LL, McNeill K (1992) Efficacy of digital radiography for the detection of pneumothorax: comparison with conventional chest radiography. Am J Roentgenol 158:509–514
14.
go back to reference Murphey MD, Quale JL, Martin NL, Bramble JM, Cook LT, Dwyer SJ (1992) Computed radiography in musculoskeletal imaging: state of the art. Am J Roentgenol 158:19–27 Murphey MD, Quale JL, Martin NL, Bramble JM, Cook LT, Dwyer SJ (1992) Computed radiography in musculoskeletal imaging: state of the art. Am J Roentgenol 158:19–27
15.
go back to reference Saito H, Kurashina T, Ishibashi T, Shimanuki Y, Sakamoto K (1988) Digital radiography in an intensive care unit. Clin Radiol 39:127–130PubMed Saito H, Kurashina T, Ishibashi T, Shimanuki Y, Sakamoto K (1988) Digital radiography in an intensive care unit. Clin Radiol 39:127–130PubMed
16.
go back to reference Strotzer M, Gmeinwieser J, Volk M, Frund R, Seitz J, Manke C, Albrich H, Feuerbach S (1998) Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography. Am J Roentgenol 171:23–27 Strotzer M, Gmeinwieser J, Volk M, Frund R, Seitz J, Manke C, Albrich H, Feuerbach S (1998) Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography. Am J Roentgenol 171:23–27
17.
go back to reference Murphey MD (1989) Digital skeletal radiography: spatial resolution requirements for detection of subperiosteal resorption. Am J Roentgenol 152:541–546 Murphey MD (1989) Digital skeletal radiography: spatial resolution requirements for detection of subperiosteal resorption. Am J Roentgenol 152:541–546
18.
go back to reference Bramble JM, Murphey MD (1990) Comparison of digital and conventional musculoskeletal radiography: observer performance study. Radiology 177:587–589 Bramble JM, Murphey MD (1990) Comparison of digital and conventional musculoskeletal radiography: observer performance study. Radiology 177:587–589
19.
go back to reference Wilson AJ (1995) Filmless musculoskeletal radiology: why is it taking so long? Am J Roentgenol 165:105–107 Wilson AJ (1995) Filmless musculoskeletal radiology: why is it taking so long? Am J Roentgenol 165:105–107
20.
go back to reference Buckwalter KA, Braunstein EM (1992) Digital skeletal radiography. Am J Roentgenol 158:1071–1080 Buckwalter KA, Braunstein EM (1992) Digital skeletal radiography. Am J Roentgenol 158:1071–1080
21.
go back to reference Wilson AJ, Hodge JC (1995) Digitized radiographs in skeletal trauma; a performance comparison between a digital workstation and the original film images. Radiology 196:565–568PubMed Wilson AJ, Hodge JC (1995) Digitized radiographs in skeletal trauma; a performance comparison between a digital workstation and the original film images. Radiology 196:565–568PubMed
22.
go back to reference Seeley GW, Fisher HD, Stempski MO, Borgstrom M, Bjelland J, Capp MP (1987) Total digital radiology department: spatial resolution requirements. Am J Roentgenol 148:421–426 Seeley GW, Fisher HD, Stempski MO, Borgstrom M, Bjelland J, Capp MP (1987) Total digital radiology department: spatial resolution requirements. Am J Roentgenol 148:421–426
23.
go back to reference Templeton AW, Dwyer SJ, Cox GG, Lee KR, Johnson JA, Martin NL, Chang CH, Anderson WH, Hensley KS, Bialek J (1987) A digital radiology imaging system: description and clinical evaluation. Am J Roentgenol 149:847–851 Templeton AW, Dwyer SJ, Cox GG, Lee KR, Johnson JA, Martin NL, Chang CH, Anderson WH, Hensley KS, Bialek J (1987) A digital radiology imaging system: description and clinical evaluation. Am J Roentgenol 149:847–851
24.
go back to reference Kogutt MS, Jones JP, Perkins DD (1988) Low-dose digital computed radiography in pediatric chest imaging. Am J Roentgenol 151:775–779 Kogutt MS, Jones JP, Perkins DD (1988) Low-dose digital computed radiography in pediatric chest imaging. Am J Roentgenol 151:775–779
25.
go back to reference Aitken AG, Flodmark O, Newman DE, Kilcoyne RF, Shuman WP, Mack LA (1985) Leg length determination by CT digital radiography. Am J Roentgenol 144:613–615 Aitken AG, Flodmark O, Newman DE, Kilcoyne RF, Shuman WP, Mack LA (1985) Leg length determination by CT digital radiography. Am J Roentgenol 144:613–615
26.
go back to reference Marshall NW, Faulkner K, Busch HP, Marsh DM, Pfenning H (1994) An investigation into the radiation dose associated with different imaging systems for chest radiology. Br J Radiol 67:353–359PubMed Marshall NW, Faulkner K, Busch HP, Marsh DM, Pfenning H (1994) An investigation into the radiation dose associated with different imaging systems for chest radiology. Br J Radiol 67:353–359PubMed
27.
go back to reference Fajardo LL, Hillman BJ, Pond GD, Carmody RF, Johnson JE, Ferrell WR (1989) Detection of pneumothorax: comparison of digital and conventional chest imaging. Am J Roentgenol 152:475–480 Fajardo LL, Hillman BJ, Pond GD, Carmody RF, Johnson JE, Ferrell WR (1989) Detection of pneumothorax: comparison of digital and conventional chest imaging. Am J Roentgenol 152:475–480
28.
go back to reference Brody AS, Saks BJ, Field DR, Skinner SR, Capra RE (1986) Artifacts seen during CT pelvimetry: implications for digital systems with scanning beams. Radiology 160:269–271PubMed Brody AS, Saks BJ, Field DR, Skinner SR, Capra RE (1986) Artifacts seen during CT pelvimetry: implications for digital systems with scanning beams. Radiology 160:269–271PubMed
29.
go back to reference Wade FA, Oliver CW, McBride K (2000) Digital imaging in trauma and orthopaedic surgery: is it worth it? J Bone Joint Surg [Br] 82-B: 791–794 Wade FA, Oliver CW, McBride K (2000) Digital imaging in trauma and orthopaedic surgery: is it worth it? J Bone Joint Surg [Br] 82-B: 791–794
Metadata
Title
Report on a new type of trauma full-body digital X-ray machine
Authors
S. Beningfield
H. Potgieter
A. Nicol
S. van As
G. Bowie
E. Hering
E. Lätti
Publication date
01-04-2003
Publisher
Springer-Verlag
Published in
Emergency Radiology / Issue 1/2003
Print ISSN: 1070-3004
Electronic ISSN: 1438-1435
DOI
https://doi.org/10.1007/s10140-003-0271-x

Other articles of this Issue 1/2003

Emergency Radiology 1/2003 Go to the issue