Effects of different dentin thicknesses and air cooling on pulpal temperature rise during laser welding

Authors: Asli Secilmis, Mehmet Bulbul, Tugrul Sari, Aslihan Usumez

Published in: Lasers in Medical Science | Issue 1/2013

Login to get access

Abstract

The neodymium/yttrium–aluminum–garnet (Nd/YAG) laser has been suggested to repair broken prostheses in the mouth. This study investigated the effects of different dentin thicknesses and air cooling on pulpal temperature rise during laser welding. Three intact human maxillary molars were prepared for full-veneer crown. For each tooth, dentin thicknesses in mesiobuccal cusp was 2, 3, or 4 mm. Twenty dies were duplicated from each of the prepared teeth. For metal copings with 0.5-mm thickness, wax patterns were prepared with dip wax technique directly onto each of dies. All patterns were sprued and invested. The castings were made using a nickel–chromium alloy (Nicromed Premium, Neodontics). A hole with 0.5-mm diameter was prepared on the mesiobuccal cusp of each crown. The Nd/YAG laser (9.85 W; 1 Hz repetition rate; fluence, 1.230 J/cm2; Fidelis Plus 3, Fotona) was used for welding with or without air cooling (n = 10). The temperature rise was measured in pulpal chamber with a J-type thermocouple wire that was connected to a data logger. Differences between start and highest temperature reading were taken, and temperature rise values were compared using two-way analysis of variance and Tukey’s honestly significant difference tests (α = .05). Pulpal temperature rise varied significantly depending on the dentin thickness and air cooling (p < 0.05). The non-air cooling group induced significantly the highest temperature increases. There were no significant differences between 2- and 3-mm dentin thicknesses groups (p > 0.05); however, pulpal temperature rise was the lowest for 4-mm dentin thickness group (p < 0.05). The highest values of thermal increase were found in the pulp chamber (6.8°C) when no air cooling was used in 2-mm dentin thickness group. Laser welding on base metal castings with Nd/YAG laser can be applied with air cooling to avoid temperature rises known to adversely affect pulpal health when dentin thickness is 2 or 3 mm.
Literature
1.
go back to reference Powers JM, Sakaguchi RL (2006) Craig’s restorative dental materials: properties, 12th edn. Elsevier, St. Louis, p 375 Powers JM, Sakaguchi RL (2006) Craig’s restorative dental materials: properties, 12th edn. Elsevier, St. Louis, p 375
2.
go back to reference Shimakura M, Yamada S, Takeuchi M, Miura K, Ikeyama J (2009) Influence of irradiation conditions on the deformation of pure titanium frames in laser welding. Dent Mater J 28:243–247PubMedCrossRef Shimakura M, Yamada S, Takeuchi M, Miura K, Ikeyama J (2009) Influence of irradiation conditions on the deformation of pure titanium frames in laser welding. Dent Mater J 28:243–247PubMedCrossRef
3.
go back to reference Kakimoto K (1988) Basic study on laser welding of Ag–Pd–Cu–Au alloy. Part 3. Factors on mechanical properties. J Jpn Prosthodont Soc 32:62–73CrossRef Kakimoto K (1988) Basic study on laser welding of Ag–Pd–Cu–Au alloy. Part 3. Factors on mechanical properties. J Jpn Prosthodont Soc 32:62–73CrossRef
4.
go back to reference Kakimoto K, Moriguchi A, Uenishi K, Komasa Y, Gonda Y (2001) Laser weldability of dental cobalt chromium alloy. Shika Igaku 64:35–47 Kakimoto K, Moriguchi A, Uenishi K, Komasa Y, Gonda Y (2001) Laser weldability of dental cobalt chromium alloy. Shika Igaku 64:35–47
5.
go back to reference Fornaini C, Passaretti F, Villa E, Rocca JP, Merigo E, Vescovi P, Meleti M, Manfredi M, Nammour S (2011) Intraoral laser welding: ultrastructural and mechanical analysis to compare laboratory laser and dental laser. Lasers Med Sci 26:415–420PubMedCrossRef Fornaini C, Passaretti F, Villa E, Rocca JP, Merigo E, Vescovi P, Meleti M, Manfredi M, Nammour S (2011) Intraoral laser welding: ultrastructural and mechanical analysis to compare laboratory laser and dental laser. Lasers Med Sci 26:415–420PubMedCrossRef
6.
go back to reference Fornaini C, Bertrand C, Bonanini M, Rocca JP, Nammour S (2009) Welding in the dental office by fiber-delivered laser: a new technique. Photomed Laser Surg 27:417–423PubMedCrossRef Fornaini C, Bertrand C, Bonanini M, Rocca JP, Nammour S (2009) Welding in the dental office by fiber-delivered laser: a new technique. Photomed Laser Surg 27:417–423PubMedCrossRef
7.
go back to reference Fornaini C, Vescovi P, Merigo E, Rocca JP, Mahler P, Bertrand C, Nammour S (2010) Intraoral metal laser welding: a case report. Lasers Med Sci 25:303–307PubMedCrossRef Fornaini C, Vescovi P, Merigo E, Rocca JP, Mahler P, Bertrand C, Nammour S (2010) Intraoral metal laser welding: a case report. Lasers Med Sci 25:303–307PubMedCrossRef
8.
go back to reference Coluzzi DJ (2004) Fundam Dent Lasers Sci Instrum 48:751–770 Coluzzi DJ (2004) Fundam Dent Lasers Sci Instrum 48:751–770
9.
go back to reference Shin C, Miura H, Okada D, Yamazaki A (2006) Accuracy of temporary laser welding of FPDs by Nd:YAG laser in the oral cavity. Dent Mater J 25:604–610PubMedCrossRef Shin C, Miura H, Okada D, Yamazaki A (2006) Accuracy of temporary laser welding of FPDs by Nd:YAG laser in the oral cavity. Dent Mater J 25:604–610PubMedCrossRef
10.
go back to reference Degidi M, Gehrke P, Spanel A, Piattelli A (2006) Syncrystallization: a technique for temporization of immediately loaded implants with metal-reinforced acrylic resin restorations. Clin Imp Dent Res 8:123–134CrossRef Degidi M, Gehrke P, Spanel A, Piattelli A (2006) Syncrystallization: a technique for temporization of immediately loaded implants with metal-reinforced acrylic resin restorations. Clin Imp Dent Res 8:123–134CrossRef
11.
go back to reference Degidi M, Nardi D, Piattelli A (2009) Immediate rehabilitation of the edentulous mandible with a definitive prosthesis supported by an intra-oral welded titanium bar. Int J Oral Maxillofac Imp 24:342–347 Degidi M, Nardi D, Piattelli A (2009) Immediate rehabilitation of the edentulous mandible with a definitive prosthesis supported by an intra-oral welded titanium bar. Int J Oral Maxillofac Imp 24:342–347
12.
go back to reference Degidi M, Nardi D, Piattelli A (2010) Prospective study with a 2-year follow-up on immediate implant loading in the edentulous mandible with a definitive restoration using intra-oral welding. Clin Oral Imp Res 21:379–385CrossRef Degidi M, Nardi D, Piattelli A (2010) Prospective study with a 2-year follow-up on immediate implant loading in the edentulous mandible with a definitive restoration using intra-oral welding. Clin Oral Imp Res 21:379–385CrossRef
13.
go back to reference Degidi M, Nardi D, Piattelli A (2008) Immediate loading of the edentulous maxilla with a final restoration supported by an intraoral welded titanium bar: a case series of 20 consecutive cases. J Periodontol 79:2207–2213PubMedCrossRef Degidi M, Nardi D, Piattelli A (2008) Immediate loading of the edentulous maxilla with a final restoration supported by an intraoral welded titanium bar: a case series of 20 consecutive cases. J Periodontol 79:2207–2213PubMedCrossRef
14.
go back to reference Fornaini C, Bertrand C, Rocca JP, Mahler P, Bonanini M, Vescovi P, Merigo E, Nammour S (2010) Intra-oral laser welding: an in vitro evaluation of thermal increase. Lasers Med Sci 25:473–477PubMedCrossRef Fornaini C, Bertrand C, Rocca JP, Mahler P, Bonanini M, Vescovi P, Merigo E, Nammour S (2010) Intra-oral laser welding: an in vitro evaluation of thermal increase. Lasers Med Sci 25:473–477PubMedCrossRef
15.
go back to reference Pohto M, Scheinin A (1958) Microscopic observations on living dental pulp. Acta Odontol Scand 16:303–327CrossRef Pohto M, Scheinin A (1958) Microscopic observations on living dental pulp. Acta Odontol Scand 16:303–327CrossRef
16.
go back to reference Zach L, Cohen C (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 19:515–530PubMedCrossRef Zach L, Cohen C (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 19:515–530PubMedCrossRef
Metadata
Title
Effects of different dentin thicknesses and air cooling on pulpal temperature rise during laser welding
Authors
Asli Secilmis
Mehmet Bulbul
Tugrul Sari
Aslihan Usumez
Publication date
01-01-2013
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 1/2013
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-012-1108-1

Other articles of this Issue 1/2013

Lasers in Medical Science 1/2013 Go to the issue