Skip to main content
Top
Published in: Lasers in Medical Science 3/2009

01-05-2009 | Origianal Article

Two-layered multiphoton microscopic imaging of cervical tissue

Authors: Shuangmu Zhuo, Jianxin Chen, Tianshu Luo, Xingshan Jiang, Shusen Xie, Rong Chen

Published in: Lasers in Medical Science | Issue 3/2009

Login to get access

Abstract

We demonstrate the application of multiphoton microscopy (MPM) based on two-photon excited fluorescence and second harmonic generation signals in imaging two-layered structures of cervical tissue in mice. It was found that MPM is effective for visualizing two-layered cervical microstructures, monitoring the metabolic activity and the density (nuclear-to-cytoplasmic) of epithelial cells, measuring the size of epithelial cell nuclei and the thickness of the epithelial layer, and quantifying collagen in the stroma. These results suggest that, with the advent of clinical portability of typical multiphoton endoscopes, the MPM technique has the potential to be applied in vivo to the clinical diagnosis and monitoring of cervical cancer.
Literature
1.
go back to reference Pisani P, Parkin DM, Bray F, Ferlay J (1999) Estimate of the worldwide mortality from 25 cancers in 1990. Int J Cancer 83:18–29CrossRefPubMed Pisani P, Parkin DM, Bray F, Ferlay J (1999) Estimate of the worldwide mortality from 25 cancers in 1990. Int J Cancer 83:18–29CrossRefPubMed
4.
go back to reference Chen JX, Zhuo SM, Chen R, Jiang XS, Xie SS, Zou QL (2007) Depth-resolved spectral imaging of rabbit oesophageal tissue based on two-photon excited fluorescence and second-harmonic generation. New J Phys 9:212(1–12) Chen JX, Zhuo SM, Chen R, Jiang XS, Xie SS, Zou QL (2007) Depth-resolved spectral imaging of rabbit oesophageal tissue based on two-photon excited fluorescence and second-harmonic generation. New J Phys 9:212(1–12)
6.
go back to reference Fahey MT, Irwig L, Macaskill P (1995) Meta-analysis of pap test accuracy. Am J Epidemiol 141:680–689, MedlinePubMed Fahey MT, Irwig L, Macaskill P (1995) Meta-analysis of pap test accuracy. Am J Epidemiol 141:680–689, MedlinePubMed
7.
go back to reference Mitchell MF (1994) Accuracy of colposcopy. Clin Consult Obstetrics Gynecol 6:70–73 Mitchell MF (1994) Accuracy of colposcopy. Clin Consult Obstetrics Gynecol 6:70–73
8.
11.
go back to reference Zhuo SM, Chen JX, Luo TS, Zou DS, Zhao JJ (2006) Multimode nonlinear optical imaging of the dermis in ex vivo human skin based on the combination of multichannel mode and lambda mode. Opt Express 14:7810–7820, DOI 10.1364/OE.14.007810 CrossRefPubMed Zhuo SM, Chen JX, Luo TS, Zou DS, Zhao JJ (2006) Multimode nonlinear optical imaging of the dermis in ex vivo human skin based on the combination of multichannel mode and lambda mode. Opt Express 14:7810–7820, DOI 10.​1364/​OE.​14.​007810 CrossRefPubMed
13.
go back to reference Tiede LM, Rocha-Sanchez SM, Hallworth R, Nichols MG, Beisel K (2007) Determination of hair cell metabolic state in isolated cochlear preparations by two-photon microscopy. J Biomed Opt 12:0210041–0210048, DOI 10.1117/1.2714777 CrossRef Tiede LM, Rocha-Sanchez SM, Hallworth R, Nichols MG, Beisel K (2007) Determination of hair cell metabolic state in isolated cochlear preparations by two-photon microscopy. J Biomed Opt 12:0210041–0210048, DOI 10.​1117/​1.​2714777 CrossRef
15.
go back to reference Campagnola PJ, Loew LM (2003) Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms. Nat Biotechnol 21:1356–1360, Medline. DOI 10.1038/nbt894 CrossRefPubMed Campagnola PJ, Loew LM (2003) Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms. Nat Biotechnol 21:1356–1360, Medline. DOI 10.​1038/​nbt894 CrossRefPubMed
16.
go back to reference Chang SK, Mirabal YN, Atkinson EN, Cox D, Malpica A, Follen M, Richards-Kortum R (2005) Combined reflectance and fluorescence spectroscopy for in vivo detection of cervical pre-cancer. J Biomed Opt 10:02403(1–11), DOI 10.1117/1.1899686 CrossRefPubMed Chang SK, Mirabal YN, Atkinson EN, Cox D, Malpica A, Follen M, Richards-Kortum R (2005) Combined reflectance and fluorescence spectroscopy for in vivo detection of cervical pre-cancer. J Biomed Opt 10:02403(1–11), DOI 10.​1117/​1.​1899686 CrossRefPubMed
Metadata
Title
Two-layered multiphoton microscopic imaging of cervical tissue
Authors
Shuangmu Zhuo
Jianxin Chen
Tianshu Luo
Xingshan Jiang
Shusen Xie
Rong Chen
Publication date
01-05-2009
Publisher
Springer London
Published in
Lasers in Medical Science / Issue 3/2009
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-008-0570-2

Other articles of this Issue 3/2009

Lasers in Medical Science 3/2009 Go to the issue