Skip to main content
Top
Published in: Lasers in Medical Science 2/2009

Open Access 01-03-2009 | Rewiew Article

Review of methodological developments in laser Doppler flowmetry

Authors: Vinayakrishnan Rajan, Babu Varghese, Ton G. van Leeuwen, Wiendelt Steenbergen

Published in: Lasers in Medical Science | Issue 2/2009

Login to get access

Abstract

Laser Doppler flowmetry is a non-invasive method of measuring microcirculatory blood flow in tissue. In this review the technique is discussed in detail. The theoretical and experimental developments to improve the technique are reviewed. The limitations of the method are elaborated upon, and the research done so far to overcome these limitations is critically assessed.
Footnotes
1
Web of Science (ISI Web of Knowledge), search terms: [(laser and Doppler) or (laser-Doppler)] and (perfusion or microcirculation or flowmetry).
 
Literature
1.
go back to reference Drain L (1980) The laser Doppler technique, Wiley, USA Drain L (1980) The laser Doppler technique, Wiley, USA
2.
go back to reference Larsen OA, Lassen NA, Quaade F (1966) Blood flow through human adipose tissue determined with radioactive xenon. Acta Physiol Scand 66:337–345PubMedCrossRef Larsen OA, Lassen NA, Quaade F (1966) Blood flow through human adipose tissue determined with radioactive xenon. Acta Physiol Scand 66:337–345PubMedCrossRef
3.
go back to reference Rudolph AM, Heymann MA (1967) The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow. Circ Res 21:163–184PubMed Rudolph AM, Heymann MA (1967) The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow. Circ Res 21:163–184PubMed
4.
go back to reference Heymann MA, Payne BD, Hoffman JI, Rudolph AM (1977) Blood flow measurements with radionuclide-labeled particles. Prog Cardiovasc Dis 20:55–79PubMedCrossRef Heymann MA, Payne BD, Hoffman JI, Rudolph AM (1977) Blood flow measurements with radionuclide-labeled particles. Prog Cardiovasc Dis 20:55–79PubMedCrossRef
5.
go back to reference Silverman DG, Cedrone FA, Hurford WE, Bering TG, LaRossa DD (1981) Monitoring tissue elimination of fluorescein with the perfusion fluorometer: a new method to assess capillary blood flow. Surgery 90:409PubMed Silverman DG, Cedrone FA, Hurford WE, Bering TG, LaRossa DD (1981) Monitoring tissue elimination of fluorescein with the perfusion fluorometer: a new method to assess capillary blood flow. Surgery 90:409PubMed
6.
go back to reference Bollinger A, Butti P, Banas JP, Trachsler H, Seigenthaler W (1974) Red cell velocity in nailfold capillaries in man measured by a television microscope technique. Microvasc Res 7:61–72PubMedCrossRef Bollinger A, Butti P, Banas JP, Trachsler H, Seigenthaler W (1974) Red cell velocity in nailfold capillaries in man measured by a television microscope technique. Microvasc Res 7:61–72PubMedCrossRef
7.
go back to reference Black CM, Clark RP, Darton K, Goff MR, Norman TD, Spikes HA (1990) A pyroelectric thermal imaging system for use in medical diagnosis. J Biomed Eng 12:281–286PubMedCrossRef Black CM, Clark RP, Darton K, Goff MR, Norman TD, Spikes HA (1990) A pyroelectric thermal imaging system for use in medical diagnosis. J Biomed Eng 12:281–286PubMedCrossRef
8.
go back to reference Payne PA, Faddoul RY, Jawad SM (1985) A single channel pulsed Doppler ultrasound instrument for measurement of skin blood flow. Practical aspects of skin blood flow measurement (London: Biological Engineering Society) Payne PA, Faddoul RY, Jawad SM (1985) A single channel pulsed Doppler ultrasound instrument for measurement of skin blood flow. Practical aspects of skin blood flow measurement (London: Biological Engineering Society)
9.
go back to reference Briers JD (2001) Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. Physiol Meas 22:35–66CrossRef Briers JD (2001) Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. Physiol Meas 22:35–66CrossRef
10.
go back to reference Shepherd AP, Öberg PÅ (1990) Laser-Doppler blood flowmetry. Kluwer Academic Publishers, Boston Shepherd AP, Öberg PÅ (1990) Laser-Doppler blood flowmetry. Kluwer Academic Publishers, Boston
11.
go back to reference Zhao Y, Chen Z, Saxer C, Xiang S, de Boer JF, Nelson JS (2000) Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity. Opt Lett 25:114–116PubMedCrossRef Zhao Y, Chen Z, Saxer C, Xiang S, de Boer JF, Nelson JS (2000) Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity. Opt Lett 25:114–116PubMedCrossRef
12.
go back to reference Obeid AN, Barnett NJ, Dougherty G, Ward G (1990) A critical review of laser Doppler flowmetry. J Med Eng Technol 14:178–181PubMedCrossRef Obeid AN, Barnett NJ, Dougherty G, Ward G (1990) A critical review of laser Doppler flowmetry. J Med Eng Technol 14:178–181PubMedCrossRef
13.
go back to reference Vongsavan N, Matthews B (1993) Some aspects of the use of laser Doppler flow meters for recording tissue blood flow. Exp Physiol 78:1–14PubMed Vongsavan N, Matthews B (1993) Some aspects of the use of laser Doppler flow meters for recording tissue blood flow. Exp Physiol 78:1–14PubMed
14.
go back to reference Leahy MJ, de Mul FFM, Nilsson GE, Maniewski R (1999) Principles and practice of the laser-Doppler perfusion technique. Technol Health Care 7:143–162PubMed Leahy MJ, de Mul FFM, Nilsson GE, Maniewski R (1999) Principles and practice of the laser-Doppler perfusion technique. Technol Health Care 7:143–162PubMed
15.
go back to reference Vennemann P, Lindken R, Westerweel J (2007) In vivo whole-field blood velocity measurement techniques. Exp Fluids 42:495–511CrossRef Vennemann P, Lindken R, Westerweel J (2007) In vivo whole-field blood velocity measurement techniques. Exp Fluids 42:495–511CrossRef
16.
go back to reference Serov A, Steenbergen W, de Mul FFM (2001) Prediction of the photodetector signal generated by Doppler-induced speckle fluctuations: theory and some validations. J Opt Soc Am A 18:622–630CrossRef Serov A, Steenbergen W, de Mul FFM (2001) Prediction of the photodetector signal generated by Doppler-induced speckle fluctuations: theory and some validations. J Opt Soc Am A 18:622–630CrossRef
17.
go back to reference Bonner RF, Nossal R (1981) Model for laser Doppler measurements of blood flow in tissue. Appl Opt 20:2097–2107CrossRef Bonner RF, Nossal R (1981) Model for laser Doppler measurements of blood flow in tissue. Appl Opt 20:2097–2107CrossRef
18.
go back to reference Dörschel K, Müller G (1996) Velocity resolved laser Doppler blood flow measurements in skin. Flow. Meas Instrum 7:257–264CrossRef Dörschel K, Müller G (1996) Velocity resolved laser Doppler blood flow measurements in skin. Flow. Meas Instrum 7:257–264CrossRef
19.
go back to reference Larsson M, Strömberg T (2006) Toward a velocity-resolved microvascular blood flow measure by decomposition of the laser Doppler spectrum. J Biomed Opt 11:014024PubMedCrossRef Larsson M, Strömberg T (2006) Toward a velocity-resolved microvascular blood flow measure by decomposition of the laser Doppler spectrum. J Biomed Opt 11:014024PubMedCrossRef
20.
go back to reference Liebert A, Zolek N, Maniewski R (2006) Decomposition of a laser-Doppler spectrum for estimation of speed distribution of particles moving in an optically turbid medium: Monte Carlo validation study. Phys Med Biol 51:5737–5751PubMedCrossRef Liebert A, Zolek N, Maniewski R (2006) Decomposition of a laser-Doppler spectrum for estimation of speed distribution of particles moving in an optically turbid medium: Monte Carlo validation study. Phys Med Biol 51:5737–5751PubMedCrossRef
21.
go back to reference Binzoni T, Leung TS, Boggett D, Delpy DT (2003) Non-invasive laser Doppler perfusion measurements of large tissue volumes and human skeletal muscle blood RMS velocity. Phys Med Biol 48:2527–2549PubMedCrossRef Binzoni T, Leung TS, Boggett D, Delpy DT (2003) Non-invasive laser Doppler perfusion measurements of large tissue volumes and human skeletal muscle blood RMS velocity. Phys Med Biol 48:2527–2549PubMedCrossRef
22.
go back to reference Binzoni T, Leung TS, Seghier ML, Delpy DT (2004) Translational and Brownian motion in laser-Doppler flowmetry of large tissue volumes. Phys Med Biol 49:5445–5458PubMedCrossRef Binzoni T, Leung TS, Seghier ML, Delpy DT (2004) Translational and Brownian motion in laser-Doppler flowmetry of large tissue volumes. Phys Med Biol 49:5445–5458PubMedCrossRef
23.
go back to reference Lohwasser R, Soelkner G (1999) Experimental and theoretical laser-Doppler frequency spectra of a tissue like model of a human head with capillaries. Appl Opt 38:2128–2137PubMedCrossRef Lohwasser R, Soelkner G (1999) Experimental and theoretical laser-Doppler frequency spectra of a tissue like model of a human head with capillaries. Appl Opt 38:2128–2137PubMedCrossRef
24.
go back to reference Stern MD (1975) In vivo evaluation of microcirculation by coherent light scattering. Nature 254:56–58PubMedCrossRef Stern MD (1975) In vivo evaluation of microcirculation by coherent light scattering. Nature 254:56–58PubMedCrossRef
25.
go back to reference Watkins D, Holloway GA Jr (1978) An instrument to measure cutaneous blood flow using the Doppler shift of laser light. IEEE Trans Biomed Eng BME-25:28–33CrossRef Watkins D, Holloway GA Jr (1978) An instrument to measure cutaneous blood flow using the Doppler shift of laser light. IEEE Trans Biomed Eng BME-25:28–33CrossRef
26.
go back to reference Nilsson GE, Tenland T, Oberg PA (1980) Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow. IEEE Trans Biomed Eng BME-27:597–604CrossRef Nilsson GE, Tenland T, Oberg PA (1980) Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow. IEEE Trans Biomed Eng BME-27:597–604CrossRef
27.
go back to reference Nilsson GE (1984) Signal processor for laser Doppler tissue flowmeters. Med Biol Eng Comput 22:343–348PubMedCrossRef Nilsson GE (1984) Signal processor for laser Doppler tissue flowmeters. Med Biol Eng Comput 22:343–348PubMedCrossRef
28.
go back to reference Essex TJH, Byrne PO (1991) A laser Doppler scanner for imaging blood flow in skin. J Biomed Eng 13:189–193PubMedCrossRef Essex TJH, Byrne PO (1991) A laser Doppler scanner for imaging blood flow in skin. J Biomed Eng 13:189–193PubMedCrossRef
29.
go back to reference Wardell K, Jakobsson A, Nilsson GE (1993) Laser Doppler perfusion imaging by dynamic light scattering. IEEE Trans Biomed Eng 40:309–316PubMedCrossRef Wardell K, Jakobsson A, Nilsson GE (1993) Laser Doppler perfusion imaging by dynamic light scattering. IEEE Trans Biomed Eng 40:309–316PubMedCrossRef
30.
go back to reference Koelink MH, de Mul FFM, Leerkotte BJM, Greve J, Jentink HW, Graaff R, Dassel ACM, Aarnoudse JG (1994) Signal processing for a laser-Doppler blood perfusion meter. Signal Process 38:239–252CrossRef Koelink MH, de Mul FFM, Leerkotte BJM, Greve J, Jentink HW, Graaff R, Dassel ACM, Aarnoudse JG (1994) Signal processing for a laser-Doppler blood perfusion meter. Signal Process 38:239–252CrossRef
31.
go back to reference Chen YY, Lin YH, Jan IC, Liu RS, Chou NK, Jan GJ (2004) Adaptive processing bandwidth adjustment for laser Doppler flowmetry. Med Biol Eng Comput 42:277–281PubMedCrossRef Chen YY, Lin YH, Jan IC, Liu RS, Chou NK, Jan GJ (2004) Adaptive processing bandwidth adjustment for laser Doppler flowmetry. Med Biol Eng Comput 42:277–281PubMedCrossRef
32.
go back to reference Duteil L, Bernengo J, Schalla W (1985) A double wavelength laser Doppler system to investigate skin microcirculation. IEEE Trans Biomed Eng BME-32:439–447CrossRef Duteil L, Bernengo J, Schalla W (1985) A double wavelength laser Doppler system to investigate skin microcirculation. IEEE Trans Biomed Eng BME-32:439–447CrossRef
33.
go back to reference Obeid AN, Bogget D, Barnett NJ, Dougherty G, Rolfe P (1988) Depth discrimination in laser Doppler skin blood flow measurement using different lasers. Med Biol Eng Comput 26:415–419PubMedCrossRef Obeid AN, Bogget D, Barnett NJ, Dougherty G, Rolfe P (1988) Depth discrimination in laser Doppler skin blood flow measurement using different lasers. Med Biol Eng Comput 26:415–419PubMedCrossRef
34.
go back to reference Jentink HW, de Mul FFM, Hermsen RGAM, Graaff R, Greve J (1990) Monte Carlo simulations of laser Doppler blood flow measurements in tissue. Appl Opt 29:2371–2381 Jentink HW, de Mul FFM, Hermsen RGAM, Graaff R, Greve J (1990) Monte Carlo simulations of laser Doppler blood flow measurements in tissue. Appl Opt 29:2371–2381
35.
go back to reference Faber DJ, Aalders MCG, Mik EG, Hooper BA, van Gemert MJC, van Leeuwen TG (2004) Oxygen saturation-dependent absorption and scattering of blood. Phys Rev Lett 93:028102-1–028102-4 Faber DJ, Aalders MCG, Mik EG, Hooper BA, van Gemert MJC, van Leeuwen TG (2004) Oxygen saturation-dependent absorption and scattering of blood. Phys Rev Lett 93:028102-1–028102-4
36.
go back to reference Kolkman RGM (1998) Photoacoustic & pulsed-laser Doppler monitoring of blood concentration and perfusion in tissue. PhD thesis, University of Twente Kolkman RGM (1998) Photoacoustic & pulsed-laser Doppler monitoring of blood concentration and perfusion in tissue. PhD thesis, University of Twente
37.
go back to reference Gush RJ, King TA (1991) Discrimination of capillary and arterio-venular blood flow in skin by laser Doppler flowmetry. Med Biol Eng Comput 29:387–392PubMedCrossRef Gush RJ, King TA (1991) Discrimination of capillary and arterio-venular blood flow in skin by laser Doppler flowmetry. Med Biol Eng Comput 29:387–392PubMedCrossRef
38.
go back to reference Einav S, Berman HJ, Fuhro RL, DiGiovanni PR, Fine S, Fridman JD (1975) Measurement of velocity profiles of red blood cells in the microcirculation by laser doppler anemometry (LDA). Biorheology 12:207–210PubMed Einav S, Berman HJ, Fuhro RL, DiGiovanni PR, Fine S, Fridman JD (1975) Measurement of velocity profiles of red blood cells in the microcirculation by laser doppler anemometry (LDA). Biorheology 12:207–210PubMed
39.
go back to reference Koelink M, de Mul FFM, Greve J, Graaff R, Dassel ACM, Aarnoudse JG (1994) Laser Doppler blood flowmetry using two wavelengths: Monte-Carlo simulations and measurements. Appl Opt 33:3549–3558CrossRef Koelink M, de Mul FFM, Greve J, Graaff R, Dassel ACM, Aarnoudse JG (1994) Laser Doppler blood flowmetry using two wavelengths: Monte-Carlo simulations and measurements. Appl Opt 33:3549–3558CrossRef
40.
go back to reference Jakobsson A, Nilsson G (1993) Prediction of sampling depth and photon pathlength in laser Doppler flowmetry. Med Biol Eng Comput 31:301–307PubMedCrossRef Jakobsson A, Nilsson G (1993) Prediction of sampling depth and photon pathlength in laser Doppler flowmetry. Med Biol Eng Comput 31:301–307PubMedCrossRef
41.
go back to reference Liebert A, Leahy M, Maniewski R (1998) Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination. Med Biol Eng Comput 36:740–747PubMedCrossRef Liebert A, Leahy M, Maniewski R (1998) Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination. Med Biol Eng Comput 36:740–747PubMedCrossRef
42.
go back to reference Kolinko VG, de Mul FFM, Greve J, Priezzhev AV (1998) Feasibility of picosecond laser-Doppler flowmetry provides basis for time-resolved Doppler tomography of biological tissue. J Biomed Opt 3:187–190CrossRef Kolinko VG, de Mul FFM, Greve J, Priezzhev AV (1998) Feasibility of picosecond laser-Doppler flowmetry provides basis for time-resolved Doppler tomography of biological tissue. J Biomed Opt 3:187–190CrossRef
43.
go back to reference Kolkman RGM, Hondebrink E, Bolt RA, Steenbergen W, de Mul FFM (2001) Pulsed-laser Doppler flowmetry provides basis for deep perfusion probing. Rev Sci Instrum 72:4242–4244CrossRef Kolkman RGM, Hondebrink E, Bolt RA, Steenbergen W, de Mul FFM (2001) Pulsed-laser Doppler flowmetry provides basis for deep perfusion probing. Rev Sci Instrum 72:4242–4244CrossRef
44.
go back to reference de Mul FFM, van Spijker J, van der Plas D, Greve J, Aarnoudse JG, Smits TM (1984) Mini laser-Doppler (blood) flow monitor with diode laser source and detection integrated in the probe. Appl Opt 23:2970–2973PubMed de Mul FFM, van Spijker J, van der Plas D, Greve J, Aarnoudse JG, Smits TM (1984) Mini laser-Doppler (blood) flow monitor with diode laser source and detection integrated in the probe. Appl Opt 23:2970–2973PubMed
45.
go back to reference Higurashi E, Sawada R, Ito T (2003) An integrated laser blood flowmeter. J Lightwave Technol 21:591–595CrossRef Higurashi E, Sawada R, Ito T (2003) An integrated laser blood flowmeter. J Lightwave Technol 21:591–595CrossRef
46.
go back to reference Serov AN, Nieland J, Oosterbaan S, de Mul FFM, van Kranenburg H, Bekman HHPT, Steenbergen W (2006) Integrated optoelectronic probe including a vertical cavity surface emitting laser for laser Doppler perfusion. monitoring. Monitoring. IEEE Trans Biomed Eng 53:2067–2074PubMedCrossRef Serov AN, Nieland J, Oosterbaan S, de Mul FFM, van Kranenburg H, Bekman HHPT, Steenbergen W (2006) Integrated optoelectronic probe including a vertical cavity surface emitting laser for laser Doppler perfusion. monitoring. Monitoring. IEEE Trans Biomed Eng 53:2067–2074PubMedCrossRef
47.
go back to reference Petoukhova AL, Steenbergen W, de Mul FFM (2001) Path-length distribution and path-length-resolved Doppler measurements of multiply scattered photons by use of low-coherence interferometry. Opt Lett 26:1492–1494PubMedCrossRef Petoukhova AL, Steenbergen W, de Mul FFM (2001) Path-length distribution and path-length-resolved Doppler measurements of multiply scattered photons by use of low-coherence interferometry. Opt Lett 26:1492–1494PubMedCrossRef
48.
go back to reference Petoukhova AL, Steenbergen W, van Leeuwen TG, de Mul FFM (2002) Effects of absorption on coherence domain path length resolved dynamic light scattering in the diffuse regime. Appl Phys Lett 81:595–597CrossRef Petoukhova AL, Steenbergen W, van Leeuwen TG, de Mul FFM (2002) Effects of absorption on coherence domain path length resolved dynamic light scattering in the diffuse regime. Appl Phys Lett 81:595–597CrossRef
49.
go back to reference Varghese B, Rajan V, van Leeuwen TG, Steenbergen W (2007) Path-length-resolved measurements of multiple scattered photons in static and dynamic turbid media using phase-modulated low-coherence interferometry. J Biomed Opt 12:024020 Varghese B, Rajan V, van Leeuwen TG, Steenbergen W (2007) Path-length-resolved measurements of multiple scattered photons in static and dynamic turbid media using phase-modulated low-coherence interferometry. J Biomed Opt 12:024020
50.
go back to reference Huang X, Lu L, Gush RJ, Boggett DM (1996) A new, fast, high resolution laser Doppler imager for clinical and research use. Proceedings of the 6th World Congress for Microcirculation (Munich, Germany) Huang X, Lu L, Gush RJ, Boggett DM (1996) A new, fast, high resolution laser Doppler imager for clinical and research use. Proceedings of the 6th World Congress for Microcirculation (Munich, Germany)
51.
go back to reference Nilsson G (1997) Laser Doppler perfusion imaging for assessment of cutaneous microcirculation. Phlebologie 26:87–91 Nilsson G (1997) Laser Doppler perfusion imaging for assessment of cutaneous microcirculation. Phlebologie 26:87–91
52.
53.
go back to reference Linden M, Golster H, Bertuglia S, Colantuoni A, Sjöberg F, Nilsson G (1996) Evaluation of enhanced high-resolution laser Doppler imaging in an in vitro tube model with the aim of assessing blood flow in separate microvessels. Microvasc Res 56:261–270CrossRef Linden M, Golster H, Bertuglia S, Colantuoni A, Sjöberg F, Nilsson G (1996) Evaluation of enhanced high-resolution laser Doppler imaging in an in vitro tube model with the aim of assessing blood flow in separate microvessels. Microvasc Res 56:261–270CrossRef
54.
go back to reference Harrison DK, Abbot NC, Beck JS, McCollum PTA (1993) Preliminary assessment of laser Doppler perfusion imaging in human skin using the tuberculin reaction as a model. Physiol Meas 14:241–252PubMedCrossRef Harrison DK, Abbot NC, Beck JS, McCollum PTA (1993) Preliminary assessment of laser Doppler perfusion imaging in human skin using the tuberculin reaction as a model. Physiol Meas 14:241–252PubMedCrossRef
55.
go back to reference Kernick DP, Shore AC (2000) Characteristics of laser Doppler perfusion imaging in vitro and in vivo. Physiol Meas 21:333–340PubMedCrossRef Kernick DP, Shore AC (2000) Characteristics of laser Doppler perfusion imaging in vitro and in vivo. Physiol Meas 21:333–340PubMedCrossRef
56.
go back to reference Serov A, Steenbergen W, de Mul FFM (2002) Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor. Opt Lett 25:300–302CrossRef Serov A, Steenbergen W, de Mul FFM (2002) Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor. Opt Lett 25:300–302CrossRef
57.
go back to reference Serov A, Steinacher B, Lasser T (2005) Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera. Opt Express 13:3681–3689CrossRefPubMed Serov A, Steinacher B, Lasser T (2005) Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera. Opt Express 13:3681–3689CrossRefPubMed
58.
go back to reference Atlan M, Gross M, Forget BC, Vitalis T, Rancillac A, Dunn AK (2006) Frequency-domain wide-field laser Doppler in vivo imaging. Opt Lett 31:2762–2764PubMedCrossRef Atlan M, Gross M, Forget BC, Vitalis T, Rancillac A, Dunn AK (2006) Frequency-domain wide-field laser Doppler in vivo imaging. Opt Lett 31:2762–2764PubMedCrossRef
59.
go back to reference Atlan M, Gross M (2006) Laser Doppler imaging revisited. Rev Sci Instrum 77:116103CrossRef Atlan M, Gross M (2006) Laser Doppler imaging revisited. Rev Sci Instrum 77:116103CrossRef
60.
go back to reference Cochrane T, Fail T, Sherriff SB (1987) Comparison of laser Doppler and Doppler ultrasound in lower limb vascular diagnosis. Clin Phys Physiol Meas 8:231–238PubMedCrossRef Cochrane T, Fail T, Sherriff SB (1987) Comparison of laser Doppler and Doppler ultrasound in lower limb vascular diagnosis. Clin Phys Physiol Meas 8:231–238PubMedCrossRef
61.
go back to reference Seifalian AM, Stansby G, Jackson A, Howell K, Hamilton G (1994) Comparison of laser Doppler perfusion imaging, laser Doppler flowmetry, and thermographic imaging for assessment of blood flow in human skin. Eur J Vasc Surg 8:65–69PubMedCrossRef Seifalian AM, Stansby G, Jackson A, Howell K, Hamilton G (1994) Comparison of laser Doppler perfusion imaging, laser Doppler flowmetry, and thermographic imaging for assessment of blood flow in human skin. Eur J Vasc Surg 8:65–69PubMedCrossRef
62.
go back to reference Doughertyt G, Barnett NJ, Pettingerg SJ (1992) A prototype instrument combining laser Doppler flowmetry and reflection pulse oximetry. Clin Phys Physiol Meas 13:105–114CrossRef Doughertyt G, Barnett NJ, Pettingerg SJ (1992) A prototype instrument combining laser Doppler flowmetry and reflection pulse oximetry. Clin Phys Physiol Meas 13:105–114CrossRef
63.
go back to reference Holloway GA, Watkins DW (1977) Laser Doppler measurement of cutaneous blood flow. J Invest Dermatol 69:306–309PubMedCrossRef Holloway GA, Watkins DW (1977) Laser Doppler measurement of cutaneous blood flow. J Invest Dermatol 69:306–309PubMedCrossRef
64.
go back to reference Ahn H, Johansson K, Lundgren O, Nilsson GE (1987) In vivo evaluation of signal processors for laser Doppler tissue flowmeters. Med Biol Eng Comput 25:207–211PubMedCrossRef Ahn H, Johansson K, Lundgren O, Nilsson GE (1987) In vivo evaluation of signal processors for laser Doppler tissue flowmeters. Med Biol Eng Comput 25:207–211PubMedCrossRef
65.
go back to reference Obeid AN (1993) In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry. Med Biol Eng Comput 31:43–52PubMedCrossRef Obeid AN (1993) In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry. Med Biol Eng Comput 31:43–52PubMedCrossRef
66.
go back to reference Liebert A, Leahy M, Maniewski R (1995) A calibration standard for laser-Doppler perfusion measurements. Rev Sci Instrum 66:5169–5173CrossRef Liebert A, Leahy M, Maniewski R (1995) A calibration standard for laser-Doppler perfusion measurements. Rev Sci Instrum 66:5169–5173CrossRef
67.
go back to reference Shepherd AP, Riedel GL, Kiel JW, Haumschild DJ, Maxwell LC (1987) Evaluation of an infrared laser-Doppler blood flowmeter. Am J Physiol Gastrointest Liver Physiol 252:G832–G839 Shepherd AP, Riedel GL, Kiel JW, Haumschild DJ, Maxwell LC (1987) Evaluation of an infrared laser-Doppler blood flowmeter. Am J Physiol Gastrointest Liver Physiol 252:G832–G839
68.
go back to reference de Mul FFM, Koelink MH, Kok ML, Harmsma PJ, Greve J, Graaff R, Aarnoudse JG (1995) Laser-Doppler velocimetry and Monte Carlo simulations on models for blood perfusion in tissue. Appl Optics 34:6595–6611CrossRef de Mul FFM, Koelink MH, Kok ML, Harmsma PJ, Greve J, Graaff R, Aarnoudse JG (1995) Laser-Doppler velocimetry and Monte Carlo simulations on models for blood perfusion in tissue. Appl Optics 34:6595–6611CrossRef
69.
go back to reference Steenbergen W, de Mul FFM (1998) New optical tissue phantom and its use for studying laser Doppler blood flowmetry. Proc SPIE 3196:12–23CrossRef Steenbergen W, de Mul FFM (1998) New optical tissue phantom and its use for studying laser Doppler blood flowmetry. Proc SPIE 3196:12–23CrossRef
70.
go back to reference Larsson M, Steenbergen W, Strömberg T (2001) Influence of optical properties and fibre separation on laser Doppler flowmetry. J Biomed Opt 7:236–243CrossRef Larsson M, Steenbergen W, Strömberg T (2001) Influence of optical properties and fibre separation on laser Doppler flowmetry. J Biomed Opt 7:236–243CrossRef
71.
go back to reference Liebert A, Lukasiewicz P, Boggett D, Maniewski R (1999) Optoelectronic standardization of Laser Doppler perfusion monitors. Rev Sci Instrum 70:1352–1353CrossRef Liebert A, Lukasiewicz P, Boggett D, Maniewski R (1999) Optoelectronic standardization of Laser Doppler perfusion monitors. Rev Sci Instrum 70:1352–1353CrossRef
72.
go back to reference Tenland T, Salerud EG, Nilsson GE, Oberg PA (1983) Spatial and temporal variations in human skin blood flow. Int J Microcirc Clin Exp 2:81–90PubMed Tenland T, Salerud EG, Nilsson GE, Oberg PA (1983) Spatial and temporal variations in human skin blood flow. Int J Microcirc Clin Exp 2:81–90PubMed
73.
go back to reference Caspary L, Creutzig A, Alexander K (1988) Biological zero in laser Doppler fluximetry. Int J Microcirc Clin Exp 7:367–371PubMed Caspary L, Creutzig A, Alexander K (1988) Biological zero in laser Doppler fluximetry. Int J Microcirc Clin Exp 7:367–371PubMed
74.
go back to reference Fagrell B (1990) Perimed’s LDV flowmeter. In: Shepherd A P, Öberg PÅ (eds) Laser-Doppler blood flowmetry. Kluwer Academic Publishers, Boston Fagrell B (1990) Perimed’s LDV flowmeter. In: Shepherd A P, Öberg PÅ (eds) Laser-Doppler blood flowmetry. Kluwer Academic Publishers, Boston
75.
go back to reference Nilsson GE (1990) Peripheral vascular diseases. In: Shepherd AP, Öberg PÅ (eds) Laser-Doppler blood flowmetry. Kluwer Academic Publishers, Boston Nilsson GE (1990) Peripheral vascular diseases. In: Shepherd AP, Öberg PÅ (eds) Laser-Doppler blood flowmetry. Kluwer Academic Publishers, Boston
76.
go back to reference Abbot NC, Swanson-Beck J (1993) Biological zero in laser Doppler measurements in normal, ischaemic and inflamed human skin. Int J Microcirc Clin Exp 2:89–98 Abbot NC, Swanson-Beck J (1993) Biological zero in laser Doppler measurements in normal, ischaemic and inflamed human skin. Int J Microcirc Clin Exp 2:89–98
77.
go back to reference Fagrell S, Nilsson G (1995) Advantages and limitations of one point laser Doppler perfusion monitoring in clinical practice. Vasc Med Rev 6:97–101 Fagrell S, Nilsson G (1995) Advantages and limitations of one point laser Doppler perfusion monitoring in clinical practice. Vasc Med Rev 6:97–101
78.
go back to reference Kernick DP, Tooke JE, Shore AC (1999) The biological zero signal in laser Doppler fluximetry—origins and practical implications. Pflügers Arch 437:624–631PubMedCrossRef Kernick DP, Tooke JE, Shore AC (1999) The biological zero signal in laser Doppler fluximetry—origins and practical implications. Pflügers Arch 437:624–631PubMedCrossRef
79.
go back to reference Zhong J, Seifalian AM, Salerud GE, Nilsson GE (1998) A mathematical analysis on the biological zero problem in laser Doppler flowmetry. IEEE Trans Biomed Eng 45:354–364PubMedCrossRef Zhong J, Seifalian AM, Salerud GE, Nilsson GE (1998) A mathematical analysis on the biological zero problem in laser Doppler flowmetry. IEEE Trans Biomed Eng 45:354–364PubMedCrossRef
80.
go back to reference Newson TP, Obeid A, Wolten RS, Boggett D, Rolfe P (1987) Laser Doppler velocimetry: the problem of fibre movement artifacts. J Biomed Eng 9:169–172PubMedCrossRef Newson TP, Obeid A, Wolten RS, Boggett D, Rolfe P (1987) Laser Doppler velocimetry: the problem of fibre movement artifacts. J Biomed Eng 9:169–172PubMedCrossRef
81.
go back to reference Gush RJ, King TA (1987) Investigation and improved performance of optical fibre probes in laser Doppler blood flow measurement. Med Biol Eng Comput 678:29–36 Gush RJ, King TA (1987) Investigation and improved performance of optical fibre probes in laser Doppler blood flow measurement. Med Biol Eng Comput 678:29–36
82.
go back to reference Öberg PÅ (1999) Tissue motion—a disturbance in the laser-Doppler blood flow signal? Technol Health Care 7:185–192 Öberg PÅ (1999) Tissue motion—a disturbance in the laser-Doppler blood flow signal? Technol Health Care 7:185–192
83.
go back to reference Karlsson MGD, Larsson M, Strömberg T, Wårdell K (2002) Influence of tissue movements on laser Doppler perfusion imaging. Proc SPIE 4624:106–114CrossRef Karlsson MGD, Larsson M, Strömberg T, Wårdell K (2002) Influence of tissue movements on laser Doppler perfusion imaging. Proc SPIE 4624:106–114CrossRef
84.
go back to reference Karlsson MGD, Wårdell K (2005) Polarized laser Doppler perfusion imaging—reduction of movement-induced artifacts. J Biomed Opt 10:064002PubMedCrossRef Karlsson MGD, Wårdell K (2005) Polarized laser Doppler perfusion imaging—reduction of movement-induced artifacts. J Biomed Opt 10:064002PubMedCrossRef
85.
go back to reference Barnett NJ, Dougherty G, Pettinger SJ (1990) Comparative study of two laser Doppler blood flowmeters. J Med Eng Technol 14:243–249PubMedCrossRef Barnett NJ, Dougherty G, Pettinger SJ (1990) Comparative study of two laser Doppler blood flowmeters. J Med Eng Technol 14:243–249PubMedCrossRef
86.
go back to reference Petoukhova AL, Steenbergen W, Morales F, Graaff R, de Jong ED, Elstrodt JM, de Mul FF, Rakhorst G (2003) Instrument-independent flux units for laser Doppler perfusion monitoring assessed in a multi-device study on the renal cortex. Microvasc Res 66:83–90PubMedCrossRef Petoukhova AL, Steenbergen W, Morales F, Graaff R, de Jong ED, Elstrodt JM, de Mul FF, Rakhorst G (2003) Instrument-independent flux units for laser Doppler perfusion monitoring assessed in a multi-device study on the renal cortex. Microvasc Res 66:83–90PubMedCrossRef
87.
go back to reference Boggett D, Obeid AN, Blond J, Rolf P (1986) Calibration of a laser Doppler skin blood flow meter using a simple fluid model and digital signal processing. In Copeland K (ed) Electronics in medicine and biology—selected papers. IERE, London, pp 241–247 Boggett D, Obeid AN, Blond J, Rolf P (1986) Calibration of a laser Doppler skin blood flow meter using a simple fluid model and digital signal processing. In Copeland K (ed) Electronics in medicine and biology—selected papers. IERE, London, pp 241–247
88.
go back to reference Nilsson H, Larsson M, Nilsson GE, Strömberg T (2002) Photon pathlength determination based on spatially resolved diffuse reflectance. J Biomed Opt 7:478–485PubMedCrossRef Nilsson H, Larsson M, Nilsson GE, Strömberg T (2002) Photon pathlength determination based on spatially resolved diffuse reflectance. J Biomed Opt 7:478–485PubMedCrossRef
89.
go back to reference Nossal R, Bonner RF, Weiss GH (1989) Influence of path length on remote optical sensing of properties of biological tissue. Appl Opt 28:2238–2244CrossRef Nossal R, Bonner RF, Weiss GH (1989) Influence of path length on remote optical sensing of properties of biological tissue. Appl Opt 28:2238–2244CrossRef
90.
go back to reference Larsson M, Nilsson H, Strömberg T (2003) In vivo determination of local skin optical properties and photon path length by use of spatially resolved diffuse reflectance with applications in laser Doppler flowmetry. Appl Opt 42:124–134PubMedCrossRef Larsson M, Nilsson H, Strömberg T (2003) In vivo determination of local skin optical properties and photon path length by use of spatially resolved diffuse reflectance with applications in laser Doppler flowmetry. Appl Opt 42:124–134PubMedCrossRef
91.
go back to reference Rajan V, Varghese B, van Leeuwen TG, Steenbergen W (2006) Speckles in Laser Doppler perfusion imaging. Opt Lett 31:468–470PubMedCrossRef Rajan V, Varghese B, van Leeuwen TG, Steenbergen W (2006) Speckles in Laser Doppler perfusion imaging. Opt Lett 31:468–470PubMedCrossRef
92.
go back to reference Rajan V, Varghese B, van Leeuwen TG, Steenbergen W (2007) Quantification of spatial intensity correlations and photodetector intensity fluctuations of coherent light reflected from turbid particle suspensions. Phys Rev E 75:060901–060904CrossRef Rajan V, Varghese B, van Leeuwen TG, Steenbergen W (2007) Quantification of spatial intensity correlations and photodetector intensity fluctuations of coherent light reflected from turbid particle suspensions. Phys Rev E 75:060901–060904CrossRef
Metadata
Title
Review of methodological developments in laser Doppler flowmetry
Authors
Vinayakrishnan Rajan
Babu Varghese
Ton G. van Leeuwen
Wiendelt Steenbergen
Publication date
01-03-2009
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 2/2009
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-007-0524-0

Other articles of this Issue 2/2009

Lasers in Medical Science 2/2009 Go to the issue