Abstract

Photoacoustic imaging is a hybrid imaging modality that is based on the detection of acoustic waves generated by absorption of pulsed light by tissue chromophores such as hemoglobin in blood. For this technique, usually large and costly Q-switched Nd:YAG lasers are used. These lasers provide a pulse energy of at least several milliJoules. In search of alternative light sources, we investigated the use of a small and compact pulsed laser diode to image blood vessels. We proved that a pulsed laser diode can be applied for imaging blood vessels in vivo.
Literature
1.
go back to reference Hoelen CGA, de Mul FFM (1999) A new theoretical approach to photoacoustic signal generation. J Acoust Soc Am 106:695–706CrossRef Hoelen CGA, de Mul FFM (1999) A new theoretical approach to photoacoustic signal generation. J Acoust Soc Am 106:695–706CrossRef
2.
go back to reference Kolkman RGM, Klaessens JHGM, Hondebrink E, Hopman JCW, de Mul FFM, Steenbergen W, Thijssen JM, van Leeuwen TG (2004) Photoacoustic determination of blood vessel diameter. Phys Med Biol 49:4745–4756CrossRefPubMed Kolkman RGM, Klaessens JHGM, Hondebrink E, Hopman JCW, de Mul FFM, Steenbergen W, Thijssen JM, van Leeuwen TG (2004) Photoacoustic determination of blood vessel diameter. Phys Med Biol 49:4745–4756CrossRefPubMed
3.
go back to reference Wang XD, Pang YJ, Ku G, Xie XY, Stoica G, Wang LV (2003) Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain. Nat Biotechnol 21:803–806CrossRefPubMed Wang XD, Pang YJ, Ku G, Xie XY, Stoica G, Wang LV (2003) Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain. Nat Biotechnol 21:803–806CrossRefPubMed
4.
go back to reference Wang XD, Pang YJ, Ku G, Stoica G, Wang LV (2003) Three-dimensional laser-induced photoacoustic tomography of mouse brain with the skin and skull intact. Opt Lett 28:1739–1741PubMedCrossRef Wang XD, Pang YJ, Ku G, Stoica G, Wang LV (2003) Three-dimensional laser-induced photoacoustic tomography of mouse brain with the skin and skull intact. Opt Lett 28:1739–1741PubMedCrossRef
5.
go back to reference Siphanto RI, Thumma KK, Kolkman RGM, van Leeuwen TG, de Mul FFM, van Neck JW, van Adrichem LNA, Steenbergen W (2005) Serial noninvasive photoacoustic imaging of neovascularization in tumor angiogenesis. Opt Express 13:89–95CrossRef Siphanto RI, Thumma KK, Kolkman RGM, van Leeuwen TG, de Mul FFM, van Neck JW, van Adrichem LNA, Steenbergen W (2005) Serial noninvasive photoacoustic imaging of neovascularization in tumor angiogenesis. Opt Express 13:89–95CrossRef
6.
go back to reference Siphanto RI, Kolkman RGM, Huisjes A, Pilatou MC, de Mul FFM, Steenbergen W, van Adrichem LNA (2004) Imaging of small vessels using photoacoustics: an in vivo study. Lasers Surg Med 35:354–362CrossRefPubMed Siphanto RI, Kolkman RGM, Huisjes A, Pilatou MC, de Mul FFM, Steenbergen W, van Adrichem LNA (2004) Imaging of small vessels using photoacoustics: an in vivo study. Lasers Surg Med 35:354–362CrossRefPubMed
7.
go back to reference Kruger RA, Kiser WL, Reinecke DR, Kruger GA (2003) Thermoacoustic computed tomography using a conventional linear transducer array. Med Phys 30:856–860CrossRefPubMed Kruger RA, Kiser WL, Reinecke DR, Kruger GA (2003) Thermoacoustic computed tomography using a conventional linear transducer array. Med Phys 30:856–860CrossRefPubMed
8.
go back to reference Kruger RA, Kiser WL, Reinecke DR, Kruger GA and Miller KD (2003) Thermoacoustic optical molecular imaging of small animals. Mol Imaging 2:113–123CrossRefPubMed Kruger RA, Kiser WL, Reinecke DR, Kruger GA and Miller KD (2003) Thermoacoustic optical molecular imaging of small animals. Mol Imaging 2:113–123CrossRefPubMed
9.
go back to reference Kolkman RGM, Hondebrink E, Steenbergen W, de Mul FFM (2003) In vivo photoacoustic imaging of blood vessels using an extreme-narrow aperture sensor. IEEE J Sel Top Quantum Electron 9:343–346CrossRef Kolkman RGM, Hondebrink E, Steenbergen W, de Mul FFM (2003) In vivo photoacoustic imaging of blood vessels using an extreme-narrow aperture sensor. IEEE J Sel Top Quantum Electron 9:343–346CrossRef
10.
go back to reference Kolkman RGM, Hondebrink E, Steenbergen W, van Leeuwen TG, de Mul FFM (2004) Photoacoustic imaging with a double-ring sensor featuring a narrow aperture. J Biomed Opt 9:1327–1335CrossRefPubMed Kolkman RGM, Hondebrink E, Steenbergen W, van Leeuwen TG, de Mul FFM (2004) Photoacoustic imaging with a double-ring sensor featuring a narrow aperture. J Biomed Opt 9:1327–1335CrossRefPubMed
11.
go back to reference Niederhauser JJ, Jaeger M, Lemor R, Weber P, Frenz M (2005) Combined ultrasound and optoacoustic system for real-time high-contrast vascular imaging in vivo. IEEE Trans Med Imaging 24:436–440CrossRefPubMed Niederhauser JJ, Jaeger M, Lemor R, Weber P, Frenz M (2005) Combined ultrasound and optoacoustic system for real-time high-contrast vascular imaging in vivo. IEEE Trans Med Imaging 24:436–440CrossRefPubMed
12.
go back to reference Viator JA, Choi B, Ambrose M, Spanier J, Nelson JS (2003) In vivo port-wine stain depth determination with a photoacoustic probe. Appl Opt 42:3215–3224PubMedCrossRef Viator JA, Choi B, Ambrose M, Spanier J, Nelson JS (2003) In vivo port-wine stain depth determination with a photoacoustic probe. Appl Opt 42:3215–3224PubMedCrossRef
13.
go back to reference Bosschaart N, Kolkman RGM, van Leeuwen TG, Steenbergen W (2006) Imaging of venous valves with photoacoustics. In: Oraevsky AA, Wang LV (eds) Photons plus ultrasound: imaging and sensing 2006, Proceedings of SPIE vol 6086, SPIE Bellingham (in press) Bosschaart N, Kolkman RGM, van Leeuwen TG, Steenbergen W (2006) Imaging of venous valves with photoacoustics. In: Oraevsky AA, Wang LV (eds) Photons plus ultrasound: imaging and sensing 2006, Proceedings of SPIE vol 6086, SPIE Bellingham (in press)
14.
go back to reference Kruger RA, Kiser WL Jr, Romilly AP, Schmidt P (2001) Thermoacoustic CT of the breast: pilot study observations. In: Oraevsky AA (ed) Biomedical Optoacoustics II, Proceedings of SPIE vol 4256, SPIE Bellingham, pp 1–5 Kruger RA, Kiser WL Jr, Romilly AP, Schmidt P (2001) Thermoacoustic CT of the breast: pilot study observations. In: Oraevsky AA (ed) Biomedical Optoacoustics II, Proceedings of SPIE vol 4256, SPIE Bellingham, pp 1–5
15.
go back to reference Manohar S, Kharine A, van Hespen JCG, Steenbergen W, van Leeuwen TG (2005) The Twente photoacoustic mammoscope: system overview and performance. Phys Med Biol 50:2543–2557CrossRefPubMed Manohar S, Kharine A, van Hespen JCG, Steenbergen W, van Leeuwen TG (2005) The Twente photoacoustic mammoscope: system overview and performance. Phys Med Biol 50:2543–2557CrossRefPubMed
16.
go back to reference Oraevsky AA, Andreev VG, Karabutov AA, Solomatin SV, Savateeva EV, Fleming RD, Gatalica Z, Singh H (2001) Laser optoacoustic imaging of breast cancer in vivo. In: Oraevsky AA (ed) Biomedical Optoacoustics II, Proceedings of SPIE vol 4256, SPIE Bellingham, pp 81–94 Oraevsky AA, Andreev VG, Karabutov AA, Solomatin SV, Savateeva EV, Fleming RD, Gatalica Z, Singh H (2001) Laser optoacoustic imaging of breast cancer in vivo. In: Oraevsky AA (ed) Biomedical Optoacoustics II, Proceedings of SPIE vol 4256, SPIE Bellingham, pp 81–94
17.
go back to reference Allen TJ, Cox BT, Beard PC (2005) Generating photoacoustic signals using high-peak power pulsed laser diodes. In: Oraevsky AA, Wang LV (eds) Photons plus ultrasound: Imaging and sensing 2005, Proceedings of SPIE vol 5697, SPIE Bellingham, pp 233–242 Allen TJ, Cox BT, Beard PC (2005) Generating photoacoustic signals using high-peak power pulsed laser diodes. In: Oraevsky AA, Wang LV (eds) Photons plus ultrasound: Imaging and sensing 2005, Proceedings of SPIE vol 5697, SPIE Bellingham, pp 233–242
18.
go back to reference International standard IEC 60825-1:1993+A1:1997+A2 (2001) Safety of laser products—Part 1: Equipment classification, requirements and user’s guide, IEC Geneva, Switzerland International standard IEC 60825-1:1993+A1:1997+A2 (2001) Safety of laser products—Part 1: Equipment classification, requirements and user’s guide, IEC Geneva, Switzerland
Metadata
Title
In vivo photoacoustic imaging of blood vessels with a pulsed laser diode
Authors
Roy G. M. Kolkman
Wiendelt Steenbergen
Ton G. van Leeuwen
Publication date
01-09-2006
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 3/2006
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-006-0384-z

Other articles of this Issue 3/2006

Lasers in Medical Science 3/2006 Go to the issue