Skip to main content
Top
Published in: Journal of Artificial Organs 4/2019

01-12-2019 | Implantable Cardioverter Defibrillator | Case Report

Infective endocarditis of bovine pericardial patch in the aortic position in a patient with left ventricular assist device

Authors: Masaro Nakae, Daisuke Yoshioka, Koichi Toda, Shigeru Miyagawa, Yasushi Yoshikawa, Hiroki Hata, Satoshi Kainuma, Takuji Kawamura, Ai Kawamura, Yoshiki Sawa

Published in: Journal of Artificial Organs | Issue 4/2019

Login to get access

Abstract

A 53-year old woman, who had a history of left ventricular assist device implantation for acromegalic cardiomyopathy and aortic valve closure with bovine pericardial patch, was diagnosed with active endocarditis of aortic valve closure patch. The investigation revealed that infection was limited to the aortic valve closure patch; thus, redo aortic valve closure with a new bovine pericardial patch was performed. The postoperative course was uneventful and the infection was sufficiently controlled. Early surgical intervention is mandatory for a good result without spread of infection to the left ventricular assist device pump and formation of embolism.
Literature
1.
go back to reference Hannan MM, Xie R, Kirklin JK, et al. Epidemiology of infection in mechanical circulatory support: a global analysis from the ISHLT Mechanically Assisted Circulatory Support Registry. J Heart Lung Transplant. 2019; Jan 17. pii: S1053-2498(19)30008-7. Hannan MM, Xie R, Kirklin JK, et al. Epidemiology of infection in mechanical circulatory support: a global analysis from the ISHLT Mechanically Assisted Circulatory Support Registry. J Heart Lung Transplant. 2019; Jan 17. pii: S1053-2498(19)30008-7.
2.
go back to reference Nienaber JJ, Kusne S, Sohail MR, et al. Clinical Manifestations and management of left ventricular assist device-associated infections. Clin Infect Dis. 2013;57:1438–48.CrossRef Nienaber JJ, Kusne S, Sohail MR, et al. Clinical Manifestations and management of left ventricular assist device-associated infections. Clin Infect Dis. 2013;57:1438–48.CrossRef
3.
go back to reference Thyagarajan B, Kumar MP, Agrawal A, et al. Endocarditis in left ventricular assist device. Intractable Rare Dis Res. 2016;5:177–84.CrossRef Thyagarajan B, Kumar MP, Agrawal A, et al. Endocarditis in left ventricular assist device. Intractable Rare Dis Res. 2016;5:177–84.CrossRef
4.
go back to reference Yoshioka D, Okazaki S, Sawa Y, et al. Prevalence of cerebral microbleeds in patients with continuous-flow left ventricular assist devices. J Am Heart Assoc. 2017;6:005955.CrossRef Yoshioka D, Okazaki S, Sawa Y, et al. Prevalence of cerebral microbleeds in patients with continuous-flow left ventricular assist devices. J Am Heart Assoc. 2017;6:005955.CrossRef
5.
go back to reference Yoshioka D, Sakaniwa R, Sawa Y, et al. Relationship between bacteremia and hemorrhagic stroke in patients with continuous-flow left ventricular assist device. Circ J. 2018;82:448–56.CrossRef Yoshioka D, Sakaniwa R, Sawa Y, et al. Relationship between bacteremia and hemorrhagic stroke in patients with continuous-flow left ventricular assist device. Circ J. 2018;82:448–56.CrossRef
Metadata
Title
Infective endocarditis of bovine pericardial patch in the aortic position in a patient with left ventricular assist device
Authors
Masaro Nakae
Daisuke Yoshioka
Koichi Toda
Shigeru Miyagawa
Yasushi Yoshikawa
Hiroki Hata
Satoshi Kainuma
Takuji Kawamura
Ai Kawamura
Yoshiki Sawa
Publication date
01-12-2019
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 4/2019
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-019-01126-2

Other articles of this Issue 4/2019