Published in: Journal of Artificial Organs 1/2014

01-03-2014 | Original Article

Paracorporeal ventricular assist device as a bridge to transplant candidacy in the era of implantable continuous-flow ventricular assist device

Authors: Hideaki Suwa, Osamu Seguchi, Tomoyuki Fujita, Yoshihiro Murata, Michinari Hieda, Takuya Watanabe, Takuma Sato, Haruki Sunami, Masanobu Yanase, Hiroki Hata, Takeshi Nakatani

Published in: Journal of Artificial Organs | Issue 1/2014

Login to get access

Abstract

Ventricular assist devices (VADs) have long been used as bridge to transplant therapy (BTT). Nipro-Toyobo paracorporeal pulsatile-flow VAD (nt-VAD) was the only device available until April 2011, when implantable continuous-flow VADs (cf-VADs) became available. Although cf-VADs are central to BTT, nt-VAD remains a necessary option. We aimed to clarify the role of nt-VAD in an era of increasing cf-VAD use. We retrospectively reviewed patients who underwent VAD implantation at the National Cerebral and Cardiovascular Center from May 2011 to March 2013. Characteristics were compared between the nt-VAD and cf-VAD groups. Twenty-nine patients (mean age 37.7 ± 11.1 years, 23 males) underwent VAD implantation. Fifteen patients initially received nt-VADs, although 4 were converted to cf-VADs. Of these 15 patients, 3 were too small for cf-VADs and 2 needed bilateral ventricular support. The remaining 10 patients received nt-VADs (7 patients at INTERMACS level 1 and 3 at level 2). The nt-VAD group patients had significantly more preoperative mechanical circulatory support and were in a more critical condition before VAD implantation than the cf-VAD group. The 2-year survival rate was not significantly different. Despite the critical conditions of nt-VAD patients, their overall survival is not statistically inferior to that of cf-VAD patients. nt-VAD is a good option as a BTC for the patient with urgent and critical condition.
Literature
1.
go back to reference Miller LW, Pagani FD, Russell SD, John R, Boyle AJ, Aaronson KD, Conte JV, Naka Y, Mancini D, Delgado RM, MacGillivray TE, Farrar DJ, Frazier OH, HeartMate II Clinical Investigators. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med. 2007;357:885–96.PubMedCrossRef Miller LW, Pagani FD, Russell SD, John R, Boyle AJ, Aaronson KD, Conte JV, Naka Y, Mancini D, Delgado RM, MacGillivray TE, Farrar DJ, Frazier OH, HeartMate II Clinical Investigators. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med. 2007;357:885–96.PubMedCrossRef
2.
go back to reference Pagani FD, Miller LW, Russell SD, Aaronson KD, John R, Boyle AJ, Conte JV, Bogaev RC, MacGillivray TE, Naka Y, Mancini D, Massey HT, Chen L, Klodell CT, Aranda JM, Moazami N, Ewald GA, Farrar DJ, Frazier OH, HeartMate II Investigators. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol. 2009;54:312–21.PubMedCrossRef Pagani FD, Miller LW, Russell SD, Aaronson KD, John R, Boyle AJ, Conte JV, Bogaev RC, MacGillivray TE, Naka Y, Mancini D, Massey HT, Chen L, Klodell CT, Aranda JM, Moazami N, Ewald GA, Farrar DJ, Frazier OH, HeartMate II Investigators. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol. 2009;54:312–21.PubMedCrossRef
3.
go back to reference Slaughter MS, Rogers LG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH, HeartMate II Investigators. Advanced heart failure treated with continuous-flow left ventricular assist device. N Eng J Med. 2009;361:2241–51.CrossRef Slaughter MS, Rogers LG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH, HeartMate II Investigators. Advanced heart failure treated with continuous-flow left ventricular assist device. N Eng J Med. 2009;361:2241–51.CrossRef
4.
go back to reference Kitamura S. Heart transplantation in Japan: a critical appraisal for the results and future perspects. Gen Thorac Cardiovasc Surg. 2012;60:639–44.PubMedCrossRef Kitamura S. Heart transplantation in Japan: a critical appraisal for the results and future perspects. Gen Thorac Cardiovasc Surg. 2012;60:639–44.PubMedCrossRef
5.
go back to reference Kyo S, Minami T, Nishimura T, Gojo S, Ono M. New era for therapeutic strategy for heart failure: destination therapy by left ventricular assist device. J Cardiol. 2012;59:101–9.PubMedCrossRef Kyo S, Minami T, Nishimura T, Gojo S, Ono M. New era for therapeutic strategy for heart failure: destination therapy by left ventricular assist device. J Cardiol. 2012;59:101–9.PubMedCrossRef
6.
go back to reference Toda K, Fujita T, Kobayashi J, Shimahara Y, Kitamura S, Seguchi O, Murata Y, Yanase M, Nakatani T. Impact of preoperative percutaneous cardiopulmonary support on outcome following left ventricular assist device implantation. Circ J. 2012;76:88–95.PubMedCrossRef Toda K, Fujita T, Kobayashi J, Shimahara Y, Kitamura S, Seguchi O, Murata Y, Yanase M, Nakatani T. Impact of preoperative percutaneous cardiopulmonary support on outcome following left ventricular assist device implantation. Circ J. 2012;76:88–95.PubMedCrossRef
7.
go back to reference Kerklin JK, Naftel DC, Stevenson LW, Kormos RL, Pagani FD, Miller MA, Ulisney KL, Young JB. INTERMACS database for durable devices for circulatory support: first annual report. J Heart Lung Transpl. 2008;10:1065–72.CrossRef Kerklin JK, Naftel DC, Stevenson LW, Kormos RL, Pagani FD, Miller MA, Ulisney KL, Young JB. INTERMACS database for durable devices for circulatory support: first annual report. J Heart Lung Transpl. 2008;10:1065–72.CrossRef
8.
go back to reference Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, Tomioka J, Kormos RL, Griffith BP, Kurosawa H. EVAHEART: an implantable centrifugal blood pump for ling-term circulatory support. Jpn J Thorac Cardiovasc Surg. 2002;11:461–5.CrossRef Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, Tomioka J, Kormos RL, Griffith BP, Kurosawa H. EVAHEART: an implantable centrifugal blood pump for ling-term circulatory support. Jpn J Thorac Cardiovasc Surg. 2002;11:461–5.CrossRef
9.
go back to reference Nishinaka T, Schima H, Roethy W, Rajek A, Nojiri C, Wolner E, Wieselthaler GM. The Dureheart VAD, a magnetically levitated centrifugal pump: University of Vienna bridge-to-transplant experience. Circ J. 2006;70:1421–5.PubMedCrossRef Nishinaka T, Schima H, Roethy W, Rajek A, Nojiri C, Wolner E, Wieselthaler GM. The Dureheart VAD, a magnetically levitated centrifugal pump: University of Vienna bridge-to-transplant experience. Circ J. 2006;70:1421–5.PubMedCrossRef
10.
11.
go back to reference Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Ulisney KL, Baldwin JT, Young JB. Second INTERMACS annual report: more than 1,000 primary left ventricular assist device implant. J Heart Lung Transpl. 2010;29:1–10.CrossRef Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Ulisney KL, Baldwin JT, Young JB. Second INTERMACS annual report: more than 1,000 primary left ventricular assist device implant. J Heart Lung Transpl. 2010;29:1–10.CrossRef
12.
go back to reference Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Ulisney KL, Baldwin JT, Young JB. Third INTERMACS annual report: the revolution of destination therapy in the United State. J Heart Lung Transpl. 2011;30:115–23.CrossRef Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Ulisney KL, Baldwin JT, Young JB. Third INTERMACS annual report: the revolution of destination therapy in the United State. J Heart Lung Transpl. 2011;30:115–23.CrossRef
13.
go back to reference Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Baldwin JT, Young JB. The fourth INTERMACS annual report: 4,000 implant and counting. J Heart Lung Transpl. 2012;31:117–26.CrossRef Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Baldwin JT, Young JB. The fourth INTERMACS annual report: 4,000 implant and counting. J Heart Lung Transpl. 2012;31:117–26.CrossRef
14.
go back to reference Kirklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Baldwin JT, Young JB. Fifth INERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients. J Heart Lung Transpl. 2013;32:141–56.CrossRef Kirklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Baldwin JT, Young JB. Fifth INERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients. J Heart Lung Transpl. 2013;32:141–56.CrossRef
15.
go back to reference Saito S, Matsumiya G, Sakaguchi T, Miyagawa S, Yoshikawa Y, Yamauchi T, Kuratani T, Sawa Y. Risk factor analysis of long-term support with left ventricular assist system. Circ J. 2010;74:715–22.PubMedCrossRef Saito S, Matsumiya G, Sakaguchi T, Miyagawa S, Yoshikawa Y, Yamauchi T, Kuratani T, Sawa Y. Risk factor analysis of long-term support with left ventricular assist system. Circ J. 2010;74:715–22.PubMedCrossRef
16.
go back to reference Yoshioka D, Sakaguchi T, Saito S, Miyagawa S, Nishi H, Yoshikawa Y, Fukushima S, Ueno T, Kuratani T, Sawa Y. Initial experience of conversion of Toyobo paracorporeal left ventricular assist device to DuraHeart left ventricular assist device. Circ J. 2012;76:372–6.PubMedCrossRef Yoshioka D, Sakaguchi T, Saito S, Miyagawa S, Nishi H, Yoshikawa Y, Fukushima S, Ueno T, Kuratani T, Sawa Y. Initial experience of conversion of Toyobo paracorporeal left ventricular assist device to DuraHeart left ventricular assist device. Circ J. 2012;76:372–6.PubMedCrossRef
17.
go back to reference Ziemba EA, John R. Mechanical circulatory support for bridge to decision: which device and when to decide. J Card Surg. 2010;25:425–33.PubMedCrossRef Ziemba EA, John R. Mechanical circulatory support for bridge to decision: which device and when to decide. J Card Surg. 2010;25:425–33.PubMedCrossRef
18.
go back to reference Gonzalez-Costello J, Yang J, Sims DB, Kossar AP, Murray LK, Colombo PC, et al. Bridging cardiogenic shock patients with short-term ventricular support at a community hospital to long-term ventricular support at a tertiary hospital. J Heart Lung Transpl. 2012;31:618–24.CrossRef Gonzalez-Costello J, Yang J, Sims DB, Kossar AP, Murray LK, Colombo PC, et al. Bridging cardiogenic shock patients with short-term ventricular support at a community hospital to long-term ventricular support at a tertiary hospital. J Heart Lung Transpl. 2012;31:618–24.CrossRef
19.
go back to reference John R, Liao K, Lietz K, Kamdar F, Colvin-Adams M, Boyle A, et al. Experience with the Levitronix CentriMug circulatory support system as a bridge to decision in patients with refractory acute cardiogenic shock and multisystem organ failure. J Thorac Cardiovasc Surg. 2007;134:351–8.PubMedCrossRef John R, Liao K, Lietz K, Kamdar F, Colvin-Adams M, Boyle A, et al. Experience with the Levitronix CentriMug circulatory support system as a bridge to decision in patients with refractory acute cardiogenic shock and multisystem organ failure. J Thorac Cardiovasc Surg. 2007;134:351–8.PubMedCrossRef
Metadata
Title
Paracorporeal ventricular assist device as a bridge to transplant candidacy in the era of implantable continuous-flow ventricular assist device
Authors
Hideaki Suwa
Osamu Seguchi
Tomoyuki Fujita
Yoshihiro Murata
Michinari Hieda
Takuya Watanabe
Takuma Sato
Haruki Sunami
Masanobu Yanase
Hiroki Hata
Takeshi Nakatani
Publication date
01-03-2014
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 1/2014
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-013-0731-3

Other articles of this Issue 1/2014

Journal of Artificial Organs 1/2014 Go to the issue