A comparative study of two types of sternal pins used for sternal closure: poly-l-lactide sternal pins versus uncalcined hydroxyapatite poly-l-lactide sternal pins

Authors: Xian-ming Fu, Hideki Oshima, Yoshimori Araki, Yuji Narita, Masato Mutsuga, Noritaka Okada, Tomohiro Tsunekawa, Akihiko Usui

Published in: Journal of Artificial Organs | Issue 4/2013

Login to get access

Abstract

Bioabsorbable poly-l-lactide (PLLA) sternal pins are applied to reinforce sternal closure during cardiac surgery. However, these pins lack osteoconductivity. A new bioabsorbable sternal pin with osteoconductivity, made of uncalcined hydroxyapatite and poly-l-lactide (u-HA-PLLA) has been developed. This study was conducted to compare the two types of sternal pins in terms of sternal stability and healing after median sternotomy. Between October 2006 and January 2012, 105 patients underwent aortic surgery for aortic aneurysms or dissection via median sternotomy and sternal closure with sternal pins. Among these patients, 75 were followed for 12 months using serial computed tomography (CT). PLLA sternal pins were used in 30 patients (group A) and u-HA-PLLA sternal pins were used in 45 patients (group B). The incidence rates of transverse sternal dehiscence, anteroposterior displacement and complete sternal fusion were evaluated using CT. The cross-sectional cortical bone density area (CBDA) of the sternum around the sternal pins was examined to evaluate the osteoconductivity of the sternal pins. There were no significant differences between groups A and B in the sternal dehiscence rate (6.7 vs 4.4 %), sternal displacement rate (6.7 vs 2.2 %) or 12-month sternal fusion rate (63.3 vs 73.3 %). The CBDA around the sternal pins significantly increased between discharge and 12 months after surgery in group B (P < 0.001) but not in group A. These results show that u-HA-PLLA sternal pins exhibit certain osteoconductivity; however, both PLLA and u-HA-PLLA sternal pins provide comparable clinical outcomes regarding sternal stability and healing.
Literature
1.
go back to reference Oiwa H, Ishida R, Sudo K. Sternal closure with reabsorbable pin and cord in pediatric-less invasive cardiac surgery. Ann Thorac Surg. 2004;78:358–9.PubMedCrossRef Oiwa H, Ishida R, Sudo K. Sternal closure with reabsorbable pin and cord in pediatric-less invasive cardiac surgery. Ann Thorac Surg. 2004;78:358–9.PubMedCrossRef
2.
go back to reference Tanaka T, Okawa Y, Ishida N, Toyama M, Hashimoto M, Matsumoto K. Clinical studies of bioabsorbable poly-l-lactide sternal coaptation pins. J Cardiovasc Surg (Torino). 2001;42:749–51. Tanaka T, Okawa Y, Ishida N, Toyama M, Hashimoto M, Matsumoto K. Clinical studies of bioabsorbable poly-l-lactide sternal coaptation pins. J Cardiovasc Surg (Torino). 2001;42:749–51.
3.
go back to reference Hamaji M, Sakaguchi Y, Matsuda M, Kono S. Reinforced closure of the sternum with absorbable pins for high-risk patients. Interact Cardiovasc Thorac Surg. 2009;9:559–61.PubMedCrossRef Hamaji M, Sakaguchi Y, Matsuda M, Kono S. Reinforced closure of the sternum with absorbable pins for high-risk patients. Interact Cardiovasc Thorac Surg. 2009;9:559–61.PubMedCrossRef
4.
go back to reference Shikinami Y, Matsusue Y, Nakamura T. The complete process of bioresorption and bone replacement using devices made of forged composites of raw hydroxyapatite particles/poly-l-lactide (f-u-ha/plla). Biomaterials. 2005;26:5542–51.PubMedCrossRef Shikinami Y, Matsusue Y, Nakamura T. The complete process of bioresorption and bone replacement using devices made of forged composites of raw hydroxyapatite particles/poly-l-lactide (f-u-ha/plla). Biomaterials. 2005;26:5542–51.PubMedCrossRef
5.
go back to reference Tsunekawa T, Usui A, Oshima H, Mizutani S, Araki Y, Okada N, Ueda Y. A bioresorbable osteosynthesis device can induce an earlier sternal fusion after median sternotomy. Interact Cardiovasc Thorac Surg. 2012;15:377–81.PubMedCrossRefPubMedCentral Tsunekawa T, Usui A, Oshima H, Mizutani S, Araki Y, Okada N, Ueda Y. A bioresorbable osteosynthesis device can induce an earlier sternal fusion after median sternotomy. Interact Cardiovasc Thorac Surg. 2012;15:377–81.PubMedCrossRefPubMedCentral
6.
go back to reference Group TPMS. Risk factors for deep sternal wound infection after sternotomy: a prospective, multicenter study. J Thorac Cardiovasc Surg. 1996;111:1200–7.CrossRef Group TPMS. Risk factors for deep sternal wound infection after sternotomy: a prospective, multicenter study. J Thorac Cardiovasc Surg. 1996;111:1200–7.CrossRef
7.
go back to reference Boiselle PM, Mansilla AV, White CS, Fisher MS. Sternal dehiscence in patients with and without mediastinitis. J Thorac Imaging. 2001;16:106–10.PubMedCrossRef Boiselle PM, Mansilla AV, White CS, Fisher MS. Sternal dehiscence in patients with and without mediastinitis. J Thorac Imaging. 2001;16:106–10.PubMedCrossRef
8.
go back to reference Schimmer C, Reents W, Berneder S, Eigel P, Sezer O, Scheld H, Sahraoui K, Gansera B, Deppert O, Rubio A, Feyrer R, Sauer C, Elert O, Leyh R. Prevention of sternal dehiscence and infection in high-risk patients: a prospective randomized multicenter trial. Ann Thorac Surg. 2008;86:1897–904.PubMedCrossRef Schimmer C, Reents W, Berneder S, Eigel P, Sezer O, Scheld H, Sahraoui K, Gansera B, Deppert O, Rubio A, Feyrer R, Sauer C, Elert O, Leyh R. Prevention of sternal dehiscence and infection in high-risk patients: a prospective randomized multicenter trial. Ann Thorac Surg. 2008;86:1897–904.PubMedCrossRef
9.
go back to reference McGregor WE, Trumble DR, Magovern JA. Mechanical analysis of midline sternotomy wound closure. J Thorac Cardiovasc Surg. 1999;117:1144–50.PubMedCrossRef McGregor WE, Trumble DR, Magovern JA. Mechanical analysis of midline sternotomy wound closure. J Thorac Cardiovasc Surg. 1999;117:1144–50.PubMedCrossRef
10.
go back to reference Losanoff JE, Collier AD, Wagner-Mann CC, Richman BW, Huff H, Hsieh F, Diaz-Arias A, Jones JW. Biomechanical comparison of median sternotomy closures. Ann Thorac Surg. 2004;77:203–9.PubMedCrossRef Losanoff JE, Collier AD, Wagner-Mann CC, Richman BW, Huff H, Hsieh F, Diaz-Arias A, Jones JW. Biomechanical comparison of median sternotomy closures. Ann Thorac Surg. 2004;77:203–9.PubMedCrossRef
11.
go back to reference Casha AR, Ashraf SS, Kay PH, Cooper GJ. Routine sternal closure using interlocking multitwisted wires. Eur J Cardiothorac Surg. 1999;16:353–5.PubMedCrossRef Casha AR, Ashraf SS, Kay PH, Cooper GJ. Routine sternal closure using interlocking multitwisted wires. Eur J Cardiothorac Surg. 1999;16:353–5.PubMedCrossRef
12.
go back to reference Goldman G, Nestel R, Snir E, Vidne B. Effective technique of sternum closure in high-risk patients. Arch Surg. 1988;123:386–7.PubMedCrossRef Goldman G, Nestel R, Snir E, Vidne B. Effective technique of sternum closure in high-risk patients. Arch Surg. 1988;123:386–7.PubMedCrossRef
13.
go back to reference Ishii S, Tamura J, Furukawa T, Nakamura T, Matsusue Y, Shikinami Y, Okuno M. Long-term study of high-strength hydroxyapatite/poly(l-lactide) composite rods for the internal fixation of bone fractures: a 2-4-year follow-up study in rabbits. J Biomed Mater Res B Appl Biomater. 2003;66:539–47.PubMedCrossRef Ishii S, Tamura J, Furukawa T, Nakamura T, Matsusue Y, Shikinami Y, Okuno M. Long-term study of high-strength hydroxyapatite/poly(l-lactide) composite rods for the internal fixation of bone fractures: a 2-4-year follow-up study in rabbits. J Biomed Mater Res B Appl Biomater. 2003;66:539–47.PubMedCrossRef
Metadata
Title
A comparative study of two types of sternal pins used for sternal closure: poly-l-lactide sternal pins versus uncalcined hydroxyapatite poly-l-lactide sternal pins
Authors
Xian-ming Fu
Hideki Oshima
Yoshimori Araki
Yuji Narita
Masato Mutsuga
Noritaka Okada
Tomohiro Tsunekawa
Akihiko Usui
Publication date
01-12-2013
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 4/2013
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-013-0727-z

Other articles of this Issue 4/2013

Journal of Artificial Organs 4/2013 Go to the issue