Skip to main content
Top
Published in: Annals of Vascular Surgery 4/2006

01-07-2006 | Clinical Research

Correlation between the Measurement of Transverse Diameter in the Proximal Neck on Computed Tomography and on Aortography before Endovascular Treatment of Infrarenal Aortic Aneurysm

Authors: Milagros Martí de Gracia, MD, Beatriz Rodríguez-Vigil, MD, Gonzalo Garzón-Möll, MD, PhD, Alberto Bravo-Soberón, MD, Carlos Sánchez-Almaraz, MD, Rodolfo Alvarez-Sala-Walther, MD, PhD

Published in: Annals of Vascular Surgery | Issue 4/2006

Login to get access

Abstract

The aim of this study was to determine the correlation between the measurement of transverse diameter of the proximal neck on computed tomographic angiography (CTA) and graduated catheter aortography in patients who are candidates for endovascular graft placement in order to replace, if both measurements are equivalent, aortography for CTA alone. Preoperative dual-slice CTA and graduated catheter aortography were performed in 35 consecutive patients with infrarenal aortic aneurysm within 10 days. Transverse proximal neck diameters were measured on a true axial section on CTA reconstructions and on aortographic images, always 6 mm distal from the most inferior main renal artery. Mean, median, and standard deviation were obtained and the measurements correlated for each patient using Pearson’s correlation and linear regression analysis. A significant difference in proximal neck transverse diameter measurements was found between graduated catheter aortography and CTA in all cases. CTA values were a mean of 1.74 mm higher than aortography values. Pearson’s correlation indicates a strong correlation between both techniques, and a regression equation determines the predictive value of aortography on the basis of CTA values. Estimation of the transverse diameter of the proximal neck on aortography on the basis of that obtained on CTA allows us to affirm that CTA could be used as the sole method for the preoperative selection of appropriate endograft size in patients with infrarenal aortic aneurysm.
Literature
1.
go back to reference Horejs D, Gilbert P, Burstein S, Vogelzang RL. Normal aortoiliac diameters by CT. J. Comput. Assist Tomogr 1988;12:602-603PubMedCrossRef Horejs D, Gilbert P, Burstein S, Vogelzang RL. Normal aortoiliac diameters by CT. J. Comput. Assist Tomogr 1988;12:602-603PubMedCrossRef
2.
go back to reference Collin J, Araujo L, Walton J, Lindsell D. Oxford screening program for abdominal aortic aneurysm in men aged 65 to 74 years. Lancet 1988;10:613-615CrossRef Collin J, Araujo L, Walton J, Lindsell D. Oxford screening program for abdominal aortic aneurysm in men aged 65 to 74 years. Lancet 1988;10:613-615CrossRef
3.
go back to reference Melton L, Bickerstaff I, Hollier L, et al. Changing incidence of abdominal aortic aneurysms: a population-based study. Am J Epidemiol 1984;120:379-386PubMed Melton L, Bickerstaff I, Hollier L, et al. Changing incidence of abdominal aortic aneurysms: a population-based study. Am J Epidemiol 1984;120:379-386PubMed
4.
go back to reference Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5:491-499PubMedCrossRef Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5:491-499PubMedCrossRef
5.
go back to reference Rydberg J, Kopecky KK, Johnson MS, Patel NH, Persohn SA, Lalka SG. Endovascular repair of abdominal aortic aneurysms. AJR Am J Roentgenol 2001;177:607-614PubMed Rydberg J, Kopecky KK, Johnson MS, Patel NH, Persohn SA, Lalka SG. Endovascular repair of abdominal aortic aneurysms. AJR Am J Roentgenol 2001;177:607-614PubMed
6.
go back to reference Kaufman JA, Geller SC, Brewster DC, et al. Endovascular repair of abdominal aortic aneurysms: current status and future directions. AJR Am J Roentgenol 2000;175:289-302PubMed Kaufman JA, Geller SC, Brewster DC, et al. Endovascular repair of abdominal aortic aneurysms: current status and future directions. AJR Am J Roentgenol 2000;175:289-302PubMed
7.
go back to reference May J, White GH, Yu W, et al. Concurrent comparison of endoluminal versus open repair in the treatment of abdominal aortic aneurysms: analysis of 303 patients by life table method. J Vasc Surg 1998;27:213-221PubMedCrossRef May J, White GH, Yu W, et al. Concurrent comparison of endoluminal versus open repair in the treatment of abdominal aortic aneurysms: analysis of 303 patients by life table method. J Vasc Surg 1998;27:213-221PubMedCrossRef
8.
go back to reference Whitaker SC. Imaging of abdominal aortic aneurysm before and after endoluminal stent-graft repair. Eur J Radiol 2001;39:3-15PubMedCrossRef Whitaker SC. Imaging of abdominal aortic aneurysm before and after endoluminal stent-graft repair. Eur J Radiol 2001;39:3-15PubMedCrossRef
9.
go back to reference Faries PL, Bernheim J, Kilaru S, Hollenbeck S, Clair D, Kent KC. Selecting stent grafts for the endovascular treatment of abdominal aortic aneurysms. J Cardiovasc Surg 2003;44:511-518 Faries PL, Bernheim J, Kilaru S, Hollenbeck S, Clair D, Kent KC. Selecting stent grafts for the endovascular treatment of abdominal aortic aneurysms. J Cardiovasc Surg 2003;44:511-518
10.
go back to reference Najibi S, Terramani TT, Weiss VJ, et al. Endovascular aortic aneurysm operations. Arch Surg 2002;137:211-216PubMedCrossRef Najibi S, Terramani TT, Weiss VJ, et al. Endovascular aortic aneurysm operations. Arch Surg 2002;137:211-216PubMedCrossRef
11.
go back to reference Chuter TAM. The choice of stent-graft for endovascular repair of abdominal aortic aneurysm. J Cardiovasc Surg 2003;44:519-525 Chuter TAM. The choice of stent-graft for endovascular repair of abdominal aortic aneurysm. J Cardiovasc Surg 2003;44:519-525
12.
go back to reference Qanadli SD, Mesurolle B, Coggia M, et al. Abdominal aortic aneurysm: pretherapy assessment with dual-slice helical CT angiography. AJR Am J Roentgenol 2000;174:181-187PubMed Qanadli SD, Mesurolle B, Coggia M, et al. Abdominal aortic aneurysm: pretherapy assessment with dual-slice helical CT angiography. AJR Am J Roentgenol 2000;174:181-187PubMed
13.
go back to reference Wyers MC, Fillinger MF, Schermerhorn ML, et al. Endovascular repair of abdominal aortic aneurysm without preoperative arteriography. J Vasc Surg 2003;38:730-738PubMedCrossRef Wyers MC, Fillinger MF, Schermerhorn ML, et al. Endovascular repair of abdominal aortic aneurysm without preoperative arteriography. J Vasc Surg 2003;38:730-738PubMedCrossRef
14.
go back to reference Isokangas JM, Hietala R, Perälä J, Tervonen O. Accuracy of computer-aided measurements in endovascular stent-graft planning: an experimental study with two phantoms. Invest Radiol 2003;38:164-170PubMedCrossRef Isokangas JM, Hietala R, Perälä J, Tervonen O. Accuracy of computer-aided measurements in endovascular stent-graft planning: an experimental study with two phantoms. Invest Radiol 2003;38:164-170PubMedCrossRef
15.
go back to reference Tillich M, Hill BB, Palk DS, et al. Prediction of aortoiliac stent-graft length: comparison of measurement methods. Radiology 2001;220:475-483PubMed Tillich M, Hill BB, Palk DS, et al. Prediction of aortoiliac stent-graft length: comparison of measurement methods. Radiology 2001;220:475-483PubMed
16.
go back to reference Lutz AM, Willmann JK, Pfammatter T, et al. Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool. J Vasc Surg 2003;37:619-626PubMedCrossRef Lutz AM, Willmann JK, Pfammatter T, et al. Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool. J Vasc Surg 2003;37:619-626PubMedCrossRef
17.
go back to reference Badran MF, Gould DA, Raza I, et al. Aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol 2002;13:887-892PubMedCrossRef Badran MF, Gould DA, Raza I, et al. Aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol 2002;13:887-892PubMedCrossRef
18.
go back to reference Makaroun M, Deaton D. Is proximal aortic neck dilatation after endovascular aneurysm exclusion a cause for concern? J Vasc Surg 2001;33:39-45CrossRef Makaroun M, Deaton D. Is proximal aortic neck dilatation after endovascular aneurysm exclusion a cause for concern? J Vasc Surg 2001;33:39-45CrossRef
19.
go back to reference Golzarian J, Dussaussois L, Struyven J. Imaging of abdominal aortic aneurysms after endoluminal repair. Semin. Ultrasound CT MR 1999;20:16-24PubMedCrossRef Golzarian J, Dussaussois L, Struyven J. Imaging of abdominal aortic aneurysms after endoluminal repair. Semin. Ultrasound CT MR 1999;20:16-24PubMedCrossRef
20.
go back to reference Sonesson B, Malina M, Ivancev K, Lindh M, Lindblad B, Brunkwall J. Dilatation of the infrarenal aneurysm neck after endovascular exclusion of abdominal aortic aneurysm. J Endovasc Surg 1998:5;195-200PubMedCrossRef Sonesson B, Malina M, Ivancev K, Lindh M, Lindblad B, Brunkwall J. Dilatation of the infrarenal aneurysm neck after endovascular exclusion of abdominal aortic aneurysm. J Endovasc Surg 1998:5;195-200PubMedCrossRef
21.
go back to reference Coenegrafchts K, Rigauts H, De Letter J. Prediction of aortoiliac stent graft length: comparison of a semiautomated computed tomography angiography method and calibrated aortography. J Comput Assist Tomogr 2003;27:284-288CrossRef Coenegrafchts K, Rigauts H, De Letter J. Prediction of aortoiliac stent graft length: comparison of a semiautomated computed tomography angiography method and calibrated aortography. J Comput Assist Tomogr 2003;27:284-288CrossRef
22.
go back to reference Gorich J, Rilinger N, Sokiranski R, et al. Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography. Radiology 1999;213:767-772PubMed Gorich J, Rilinger N, Sokiranski R, et al. Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography. Radiology 1999;213:767-772PubMed
23.
go back to reference Broeders IA, Blankensteijn JD, Olree M, Mali W, Eikelboom BC. Preoperative sizing of grafts for transfemoral endovascular aneurysm management: a prospective comparative study of spiral CT angiography, arteriography, and conventional CT imaging. J Endovasc Surg 1997;4:252-261PubMedCrossRef Broeders IA, Blankensteijn JD, Olree M, Mali W, Eikelboom BC. Preoperative sizing of grafts for transfemoral endovascular aneurysm management: a prospective comparative study of spiral CT angiography, arteriography, and conventional CT imaging. J Endovasc Surg 1997;4:252-261PubMedCrossRef
24.
go back to reference May J, White G, Ly C, Jones MA, Harris JP. Endoluminal repair of abdominal aortic aneurysm prevents enlargement of the proximal neck: a 9-year life-table and 5-year longitudinal study. J Vasc Surg 2003;37:86-90PubMedCrossRef May J, White G, Ly C, Jones MA, Harris JP. Endoluminal repair of abdominal aortic aneurysm prevents enlargement of the proximal neck: a 9-year life-table and 5-year longitudinal study. J Vasc Surg 2003;37:86-90PubMedCrossRef
25.
go back to reference Rozenblit A, Marin ML, Veith FJ, Cynamon J, Wahl SI, Bakal CW. Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up helical CT. AJR Am J Roentgenol 1995;165:1473-1479PubMed Rozenblit A, Marin ML, Veith FJ, Cynamon J, Wahl SI, Bakal CW. Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up helical CT. AJR Am J Roentgenol 1995;165:1473-1479PubMed
26.
go back to reference Sawhney R, Kerlan R, Wall S, et al. Analysis of initial CT findings after endovascular repair of abdominal aortic aneurysm. Radiology 2001;220:157-160PubMed Sawhney R, Kerlan R, Wall S, et al. Analysis of initial CT findings after endovascular repair of abdominal aortic aneurysm. Radiology 2001;220:157-160PubMed
27.
go back to reference Thurnher S, Cejna M. Imaging of aortic stent-grafts and endoleaks. Radiol Clin North Am 2002;40:799-833PubMedCrossRef Thurnher S, Cejna M. Imaging of aortic stent-grafts and endoleaks. Radiol Clin North Am 2002;40:799-833PubMedCrossRef
Metadata
Title
Correlation between the Measurement of Transverse Diameter in the Proximal Neck on Computed Tomography and on Aortography before Endovascular Treatment of Infrarenal Aortic Aneurysm
Authors
Milagros Martí de Gracia, MD
Beatriz Rodríguez-Vigil, MD
Gonzalo Garzón-Möll, MD, PhD
Alberto Bravo-Soberón, MD
Carlos Sánchez-Almaraz, MD
Rodolfo Alvarez-Sala-Walther, MD, PhD
Publication date
01-07-2006
Publisher
Springer-Verlag
Published in
Annals of Vascular Surgery / Issue 4/2006
Print ISSN: 0890-5096
Electronic ISSN: 1615-5947
DOI
https://doi.org/10.1007/s10016-006-9077-0

Other articles of this Issue 4/2006

Annals of Vascular Surgery 4/2006 Go to the issue

Papers Presented to the Peripheral Vascular Surgery Society—Winter Meeting

Upper Extremity Vascular Injury: A Current In-Theater Wartime Report from Operation Iraqi Freedom