Abstract

We report on a 52-year-old male who developed late stent graft infection resulting in infective aneurysm formation with systemic septic embolization and aortoduodenal fistulation 9 months following endoluminal repair of an abdominal aortic aneurysm. Although endoluminal stent graft infection and erosion into surrounding viscera is rare, we highlight the need for awareness of this potentially catastrophic complication.
Literature
1.
go back to reference Farkas JC, Fichelle JM, Laurian C, et al. Long-term follow-up of positive cultures in 500 abdominal aortic aneurysms. Arch Surg 1993;128:284–288PubMed Farkas JC, Fichelle JM, Laurian C, et al. Long-term follow-up of positive cultures in 500 abdominal aortic aneurysms. Arch Surg 1993;128:284–288PubMed
2.
go back to reference Van der Vliet JA, Kouwenberg PP, Muytjens HL, Barengregt WB, Boll AP, Buskens FG. Relevance of bacterial culture of abdominal aortic aneurysm contents. Surgery 1966;96:129–132 Van der Vliet JA, Kouwenberg PP, Muytjens HL, Barengregt WB, Boll AP, Buskens FG. Relevance of bacterial culture of abdominal aortic aneurysm contents. Surgery 1966;96:129–132
3.
go back to reference Forneau I, Nevelsteen A, Lacroix H, Suy R. Microbiological monitoring of aortic aneurysm sac contents during abdominal aneurysmectomy: results in 176 patients and review of the literature. Acta Chir Belg 1996;96:119–122 Forneau I, Nevelsteen A, Lacroix H, Suy R. Microbiological monitoring of aortic aneurysm sac contents during abdominal aneurysmectomy: results in 176 patients and review of the literature. Acta Chir Belg 1996;96:119–122
4.
go back to reference Young D, Neary P, Mehigan D. Aorto-enteric fistula secondary to the cannibalization of an aortic graft. Eur J Vasc Endovasc Surg 2004;8:17–19. Young D, Neary P, Mehigan D. Aorto-enteric fistula secondary to the cannibalization of an aortic graft. Eur J Vasc Endovasc Surg 2004;8:17–19.
5.
go back to reference Janne DB, Soula P, Otal P, et al. Aortoduodenal fistula after endovascular stent-graft of an abdominal aortic aneurysm. J Vasc Surg 2000;31:190–195CrossRef Janne DB, Soula P, Otal P, et al. Aortoduodenal fistula after endovascular stent-graft of an abdominal aortic aneurysm. J Vasc Surg 2000;31:190–195CrossRef
6.
go back to reference Hausegger KA, Tiesenhausen K, Karaic R, Tauss J, Koch G. Aortoduodenal fistula: a late complication of intraluminal exclusion of an infrarenal aortic aneurysm. J Vasc Interv Radiol 1999;10:747–750PubMed Hausegger KA, Tiesenhausen K, Karaic R, Tauss J, Koch G. Aortoduodenal fistula: a late complication of intraluminal exclusion of an infrarenal aortic aneurysm. J Vasc Interv Radiol 1999;10:747–750PubMed
7.
go back to reference Norgren L, Jernby B, Engellau L. Aortoenteric fistula caused by a ruptured stent-graft: a case report. J Endovasc Surg 1998;5:269–272PubMedCrossRef Norgren L, Jernby B, Engellau L. Aortoenteric fistula caused by a ruptured stent-graft: a case report. J Endovasc Surg 1998;5:269–272PubMedCrossRef
8.
go back to reference Bertges DJ, Villella ER, Makaroun MS. Aortoenteric fistula due to endoleak coil embolization after endovascular AAA repair. J Endovasc Ther 2003;10:130–135PubMedCrossRef Bertges DJ, Villella ER, Makaroun MS. Aortoenteric fistula due to endoleak coil embolization after endovascular AAA repair. J Endovasc Ther 2003;10:130–135PubMedCrossRef
9.
go back to reference Makar R, Reid J, Pherwani AD, et al. Aorto-enteric fistula following endovascular repair of abdominal aortic aneurysm. Eur J Vasc Endovasc Surg 2000;20:588–590PubMedCrossRef Makar R, Reid J, Pherwani AD, et al. Aorto-enteric fistula following endovascular repair of abdominal aortic aneurysm. Eur J Vasc Endovasc Surg 2000;20:588–590PubMedCrossRef
10.
go back to reference Parry DJ, Waterworth A, Kessel D, Robertson I, Berridge DC, Scott DJ. Endovascular repair of an inflammatory abdominal aortic aneurysm complicated by aortoduodenal fistulation with an unusual presentation. J Vasc Surg 2001;33:874–879PubMedCrossRef Parry DJ, Waterworth A, Kessel D, Robertson I, Berridge DC, Scott DJ. Endovascular repair of an inflammatory abdominal aortic aneurysm complicated by aortoduodenal fistulation with an unusual presentation. J Vasc Surg 2001;33:874–879PubMedCrossRef
11.
go back to reference Ballas P. An overview of aortofemoral graft infection. Eur J Vasc Endovasc Surg 2004;14(Suppl A):3–4 Ballas P. An overview of aortofemoral graft infection. Eur J Vasc Endovasc Surg 2004;14(Suppl A):3–4
12.
go back to reference Fiorani P, Speziale F, Calisti A, et al. Endovascular graft infection: preliminary results of an international enquiry. J Endovasc Ther 2003;10:919–927PubMedCrossRef Fiorani P, Speziale F, Calisti A, et al. Endovascular graft infection: preliminary results of an international enquiry. J Endovasc Ther 2003;10:919–927PubMedCrossRef
13.
go back to reference Parsons RE, Sanchez LA, Marin ML, et al. Comparison of endovascular and conventional vascular prostheses in an experimental infection model. J Vasc Surg 1996;24:920–925PubMedCrossRef Parsons RE, Sanchez LA, Marin ML, et al. Comparison of endovascular and conventional vascular prostheses in an experimental infection model. J Vasc Surg 1996;24:920–925PubMedCrossRef
14.
go back to reference Cao P, Verzini F, Zannetti S, Parlani G, Lupattelli L, Maselli A. Device migration after endoluminal abdominal aortic aneurysm repair: analysis of 113 cases with a minimum follow-up period of 2 years. J Vasc Surg 2002;35:229–235PubMedCrossRef Cao P, Verzini F, Zannetti S, Parlani G, Lupattelli L, Maselli A. Device migration after endoluminal abdominal aortic aneurysm repair: analysis of 113 cases with a minimum follow-up period of 2 years. J Vasc Surg 2002;35:229–235PubMedCrossRef
15.
go back to reference Martin A, Copeman PW. Aorto-jejunal fistula from rupture of Teflon graft, with septic emboli in the skin. Br Med J 1967;2:155–156PubMedCrossRef Martin A, Copeman PW. Aorto-jejunal fistula from rupture of Teflon graft, with septic emboli in the skin. Br Med J 1967;2:155–156PubMedCrossRef
16.
go back to reference Calligaro KD, Veith FJ, Yuan JG, Gargiulo NJ, Dougherty MJ. Intra-abdominal aortic graft infection: complete or partial graft preservation in patients at very high risk. J Vasc Surg 2004;38:1199–1204CrossRef Calligaro KD, Veith FJ, Yuan JG, Gargiulo NJ, Dougherty MJ. Intra-abdominal aortic graft infection: complete or partial graft preservation in patients at very high risk. J Vasc Surg 2004;38:1199–1204CrossRef
Metadata
Title
Late Infection of an Endovascular Stent Graft with Septic Embolization, Colonic Perforation, and Aortoduodenal Fistula
Authors
Jonathan Ghosh, MD, MRCS (Ed)
David Murray, MRCS (Ed)
N. Khwaja, MBChB, MRCS (Ed)
Michael O. Murphy, MRCS
Anatassi Halka, MRCS
Michael G. Walker, MCh, FRCS
Publication date
01-03-2006
Publisher
Springer-Verlag
Published in
Annals of Vascular Surgery / Issue 2/2006
Print ISSN: 0890-5096
Electronic ISSN: 1615-5947
DOI
https://doi.org/10.1007/s10016-006-9006-2

Other articles of this Issue 2/2006

Annals of Vascular Surgery 2/2006 Go to the issue