Skip to main content
Top
Published in: Annals of Vascular Surgery 2/2005

01-03-2005

Suprarenal Endograft Fixation Avoids Adverse Outcomes Associated with Aortic Neck Angulation

Published in: Annals of Vascular Surgery | Issue 2/2005

Login to get access

Abstract

The advent of endovascular therapy has had a profound impact on repair of abdominal aortic aneurysms (AAA). Prudent patient selection, particularly in regard to unfavorable anatomy, is emerging as perhaps the most important determinant of endovascular abdominal aortic aneurysm repair (EVAR) outcome. The aim of this study was to examine the association of one such anatomic factor, proximal aortic neck angulation, with the incidence of adverse events following EVAR. Prospectively collected data on 289 EVAR repairs with the Talent endograft (Medtronic, Inc., Minneapolis, MN) from March 1998 to June 2000 were analyzed. Stent graft–specific adverse events studied were migration, endoleak, kinking, thrombosis, and AAA expansion. Computed tomography (CT) scanning with three-dimensional post-processing and/or aortography was used to measure aortic neck angle. Patients were categorized into one of four groups according to their neck angle: I (0-10°); II (11-39°); III (40-59°); or IV (60-85°). Outcomes were evaluated by chi-squared analysis and ANOVA. There was a direct correlation between AAA diameter and neck angle (p = 0.002). There was no difference in endoleak rate (p = 0.877), stent migration (p = 0.850), or AAA expansion rate (p = 0.599) between groups. Device kinking >45° was associated with neck angulation ≥60° (p = 0.013), but not with other adverse outcomes. The average neck angle was 30° in patients with endoleaks and 31° in patients without endoleaks. Increasing aortic neck angulation was not associated with the selected adverse outcomes within 1 year following EVAR with the Talent stent graft using suprarenal fixation with the exception of graft kinking. This may be related to the graft design that permits suprarenal aortic fixatiou of the proximal stent graft, Whether severe degrees of angulation of 60° or greater can be safely treated with suprarenal fixation requires further study.
Literature
1.
go back to reference Chuter, TA, Green, RM, Ouriel, K, DeWeese, JA 1994Infrarenal aortic aneurysm structure: implications for transfemoral repairJ Vase Surg204449 Chuter, TA, Green, RM, Ouriel, K, DeWeese, JA 1994Infrarenal aortic aneurysm structure: implications for transfemoral repairJ Vase Surg204449
2.
go back to reference Parodi, JC, Palmaz, JC, Barone, HD 1991Transfemoral intraluminal graft implantation for abdominal aortic aneurysmsAnn Vasc Surg5491499PubMed Parodi, JC, Palmaz, JC, Barone, HD 1991Transfemoral intraluminal graft implantation for abdominal aortic aneurysmsAnn Vasc Surg5491499PubMed
3.
go back to reference Dillavou, ED, Muluk, SC, Rhee, RY, et al. 2003Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair?J Vasc Surg38657663PubMed Dillavou, ED, Muluk, SC, Rhee, RY,  et al. 2003Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair?J Vasc Surg38657663PubMed
4.
go back to reference Sternbergh, WC III, Carter, G, York, JW, Yoselevitz, M, Money, SR 2002Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repairJ Vasc Surg35482486PubMed Sternbergh, WC III, Carter, G, York, JW, Yoselevitz, M, Money, SR 2002Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repairJ Vasc Surg35482486PubMed
5.
go back to reference Carpenter, JP, Baum, RA, Barker, CF, et al. 2001Impact of exclusion criteria on patient selection for endovascular abdominal aortic aneurysm repairJ Vasc Surg3410501054PubMed Carpenter, JP, Baum, RA, Barker, CF,  et al. 2001Impact of exclusion criteria on patient selection for endovascular abdominal aortic aneurysm repairJ Vasc Surg3410501054PubMed
6.
go back to reference Buth, J, Marrewijk, CJ, Harris, PL, Hop, WC, Riambau, V, Laheij, RJ 2002Outcome of endovascular abdominal aortic aneurysm repair in patients with conditions considered unfit for an open procedure: a report on the EUROSTAR experienceJ Vasc Surg35211221PubMed Buth, J, Marrewijk, CJ, Harris, PL, Hop, WC, Riambau, V, Laheij, RJ 2002Outcome of endovascular abdominal aortic aneurysm repair in patients with conditions considered unfit for an open procedure: a report on the EUROSTAR experienceJ Vasc Surg35211221PubMed
7.
go back to reference Faries, PL, Brener, BJ, Connelly, TL, et al. 2002A multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysmsJ Vasc Surg3511231128PubMed Faries, PL, Brener, BJ, Connelly, TL,  et al. 2002A multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysmsJ Vasc Surg3511231128PubMed
8.
go back to reference Criado, FJ, Fainnan, RM, Becker, GJ 2003Talent LPS AAA stent graft: results of a pivotal clinical trialJ Vasc Surg37709715PubMed Criado, FJ, Fainnan, RM, Becker, GJ 2003Talent LPS AAA stent graft: results of a pivotal clinical trialJ Vasc Surg37709715PubMed
9.
go back to reference Johnston, KW, Rutherford, RB, Tilson, MD, Shah, DM, Hollier, L, Stanley, JC 1991Suggested standards for reporting on arterial aneurysms. Subcommittee on Reporting Standards for Arterial Aneurysms, Ad Hoc Committee on Reporting Standards, Society for Vascular Surgery and North American Chapter, International Society for Cardiovascular SurgeryJ Vasc Surg13452458PubMed Johnston, KW, Rutherford, RB, Tilson, MD, Shah, DM, Hollier, L, Stanley, JC 1991Suggested standards for reporting on arterial aneurysms. Subcommittee on Reporting Standards for Arterial Aneurysms, Ad Hoc Committee on Reporting Standards, Society for Vascular Surgery and North American Chapter, International Society for Cardiovascular SurgeryJ Vasc Surg13452458PubMed
10.
go back to reference Chaikof, EL, Blankensteijn, ID, Harris, PL, et al. 2002Reporting standards for endovascular aortic aneurysm repairJ Vasc Surg3510481060PubMed Chaikof, EL, Blankensteijn, ID, Harris, PL,  et al. 2002Reporting standards for endovascular aortic aneurysm repairJ Vasc Surg3510481060PubMed
11.
go back to reference Balm, R, Stokking, R, Kaatee, R, Blankensteijn, ID, Eikelboom, BC, Leeuwen, MS 1997Computed tomographic angiographic imaging of abdominal aortic aneurysms: implications for transfemoral endovascular aneurysm managementJ Vasc Surg26231237PubMed Balm, R, Stokking, R, Kaatee, R, Blankensteijn, ID, Eikelboom, BC, Leeuwen, MS 1997Computed tomographic angiographic imaging of abdominal aortic aneurysms: implications for transfemoral endovascular aneurysm managementJ Vasc Surg26231237PubMed
12.
go back to reference Albertini, J, Kalliafas, S, Travis, S, et al. 2000Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysmsEur J Vasc Endovasc Surg19308312PubMed Albertini, J, Kalliafas, S, Travis, S,  et al. 2000Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysmsEur J Vasc Endovasc Surg19308312PubMed
13.
go back to reference Rockman, CB, Lamparello, PI, Adelman, MA, et al. 2002Aneurysm morphology as a predictor of endoleak following endovascular aortic aneurysm repair: do smaller aneurysm have better outcomes?Ann Vasc Surg16644651PubMed Rockman, CB, Lamparello, PI, Adelman, MA,  et al. 2002Aneurysm morphology as a predictor of endoleak following endovascular aortic aneurysm repair: do smaller aneurysm have better outcomes?Ann Vasc Surg16644651PubMed
14.
go back to reference Stanley, BM, Semmens, JB, Mai, Q, et al. 2001Evaluation of patient selection guidelines for endoluminal AAA repair with the Zenith stent-graft: the Australasian experienceJ Endovasc Ther8457464PubMed Stanley, BM, Semmens, JB, Mai, Q,  et al. 2001Evaluation of patient selection guidelines for endoluminal AAA repair with the Zenith stent-graft: the Australasian experienceJ Endovasc Ther8457464PubMed
15.
go back to reference Albertini, JN, Branchereau, A, Hopkinson, B, et al. 2001Mortality and morbidity following endovascular repair of abdominal aortic aneurysms: analysis of two single centre experiencesEur J Vasc Endovasc Surg22429435PubMed Albertini, JN, Branchereau, A, Hopkinson, B,  et al. 2001Mortality and morbidity following endovascular repair of abdominal aortic aneurysms: analysis of two single centre experiencesEur J Vasc Endovasc Surg22429435PubMed
16.
go back to reference Mohan, IV, Laheij, RJ, Harris, PL 2001Risk factors for endoleak and the evidence for stent-graft oversizing in patients undergoing endovascular aneurysm repairEur J Vasc Endovasc Surg21344349PubMed Mohan, IV, Laheij, RJ, Harris, PL 2001Risk factors for endoleak and the evidence for stent-graft oversizing in patients undergoing endovascular aneurysm repairEur J Vasc Endovasc Surg21344349PubMed
17.
go back to reference Hovsepian, DM, Hein, AN, Pilgram, TK, et al. 2001Endovascular abdominal aortic aneurysm repair in 144 patients: correlation of aneurysm size, proximal aortic neck length, and procedure-related complicationsJ Vasc Interv Radiol1213731382PubMed Hovsepian, DM, Hein, AN, Pilgram, TK,  et al. 2001Endovascular abdominal aortic aneurysm repair in 144 patients: correlation of aneurysm size, proximal aortic neck length, and procedure-related complicationsJ Vasc Interv Radiol1213731382PubMed
18.
go back to reference Gitlitz, DB, Ramaswami, G, Kaplan, D, Hollier, LH, Marin, ML 2001Endovascular stent grafting in the presence of aortic neck filling defects: early clinical experienceJ Vasc Surg33340344PubMed Gitlitz, DB, Ramaswami, G, Kaplan, D, Hollier, LH, Marin, ML 2001Endovascular stent grafting in the presence of aortic neck filling defects: early clinical experienceJ Vasc Surg33340344PubMed
19.
go back to reference Greenberg, R, Fairman, R, Srivastava, S, Criado, F, Green, R 2000Endovascular grafting in patients with short proximal necks: an analysis of short-term resultsCardiovasc Surg8350354PubMed Greenberg, R, Fairman, R, Srivastava, S, Criado, F, Green, R 2000Endovascular grafting in patients with short proximal necks: an analysis of short-term resultsCardiovasc Surg8350354PubMed
20.
go back to reference Greenberg, RK, Clair, D, Srivastava, S, et al. 2003Should patients with challenging anatomy be offered endovascular aneurysm repair?J Vasc Surg38990996PubMed Greenberg, RK, Clair, D, Srivastava, S,  et al. 2003Should patients with challenging anatomy be offered endovascular aneurysm repair?J Vasc Surg38990996PubMed
21.
go back to reference Dias, NV, Resch, T, Malina, M, Lindblad, B, Ivancev, K 2001Intraoperative proximal endoleaks during AAA stent-graft repair: evaluation of risk factors and treatment with Palmaz stentsJ Endovasc Ther8268273PubMed Dias, NV, Resch, T, Malina, M, Lindblad, B, Ivancev, K 2001Intraoperative proximal endoleaks during AAA stent-graft repair: evaluation of risk factors and treatment with Palmaz stentsJ Endovasc Ther8268273PubMed
22.
go back to reference Makaroun, MS 2001The Ancure endografting system: an updateJ Vasc Surg33S129S134PubMed Makaroun, MS 2001The Ancure endografting system: an updateJ Vasc Surg33S129S134PubMed
23.
go back to reference Beebe, HG, Cronenwett, JL, Katzen, BT, Brewster, DC, Green, RM 2001Results of an aortic endograft trial: impact of device failure beyond 12 monthsJ Vasc Surg33S55S63PubMed Beebe, HG, Cronenwett, JL, Katzen, BT, Brewster, DC, Green, RM 2001Results of an aortic endograft trial: impact of device failure beyond 12 monthsJ Vasc Surg33S55S63PubMed
24.
go back to reference Arko, FR, Lee, W A, Hill, BB, Cipriano, P, Fogarty, TJ, Zarins, CK 2001Increased flexibility of AneuRx stent-graft reduces need for secondary intervention following endovascular aneurysm repairJ Endovasc Ther8583591PubMed Arko, FR, Lee, W A, Hill, BB, Cipriano, P, Fogarty, TJ, Zarins, CK 2001Increased flexibility of AneuRx stent-graft reduces need for secondary intervention following endovascular aneurysm repairJ Endovasc Ther8583591PubMed
25.
go back to reference Wever, JJ, Nie, AJ, Blankensteijn, JD, Broeders, IA, Mali, WP, Eikelboom, BC 2000Dilatation of the proximal neck of infra renal aortic aneurysms after endovascular AAA repairEur J Vasc Endovasc Surg19197201PubMed Wever, JJ, Nie, AJ, Blankensteijn, JD, Broeders, IA, Mali, WP, Eikelboom, BC 2000Dilatation of the proximal neck of infra renal aortic aneurysms after endovascular AAA repairEur J Vasc Endovasc Surg19197201PubMed
26.
go back to reference Lipski, DA, Ernst, CB 1998Natural history of the residual infrarenal aorta after infrarenal abdominal aortic aneurysm repairJ Vasc Surg27805811PubMed Lipski, DA, Ernst, CB 1998Natural history of the residual infrarenal aorta after infrarenal abdominal aortic aneurysm repairJ Vasc Surg27805811PubMed
27.
go back to reference Sonesson, B, Resch, T, Lanne, T, Ivancev, K 1998The fate of the infrarenal aortic neck after open aneurysm surgeryJ Vasc Surg28889894PubMed Sonesson, B, Resch, T, Lanne, T, Ivancev, K 1998The fate of the infrarenal aortic neck after open aneurysm surgeryJ Vasc Surg28889894PubMed
28.
go back to reference Wain, RA, Marin, ML, Ohki, T, et al. 1998Endoleaks after endovascular graft treatment of aortic aneurysms: classification, risk factors, and outcomeJ Vasc Surg276978PubMed Wain, RA, Marin, ML, Ohki, T,  et al. 1998Endoleaks after endovascular graft treatment of aortic aneurysms: classification, risk factors, and outcomeJ Vasc Surg276978PubMed
29.
go back to reference Bove, PG, Long, GW, Shanley, CJ, et al. 2003Transrenal fixation of endovascular stent-grafts for infrarenal aortic aneurysm repair: mid-term resultsJ Vasc Surg37938942PubMed Bove, PG, Long, GW, Shanley, CJ,  et al. 2003Transrenal fixation of endovascular stent-grafts for infrarenal aortic aneurysm repair: mid-term resultsJ Vasc Surg37938942PubMed
30.
go back to reference Marin, ML, Parsons, RE, Hollier, LH, et al. 1998Impact of transrenal aortic endograft placement on endovascular graft repair of abdominal aortic aneurysmsJ Vasc Surg28638646PubMed Marin, ML, Parsons, RE, Hollier, LH,  et al. 1998Impact of transrenal aortic endograft placement on endovascular graft repair of abdominal aortic aneurysmsJ Vasc Surg28638646PubMed
31.
go back to reference Cowie, AG, Ashleigh, RJ, England, RE, McCollum, CN 2003Endovascular aneurysm repair with the Talent stent-graftJ Vasc Interv Radiol1410111016PubMed Cowie, AG, Ashleigh, RJ, England, RE, McCollum, CN 2003Endovascular aneurysm repair with the Talent stent-graftJ Vasc Interv Radiol1410111016PubMed
32.
go back to reference Lau, LL, Hakaim, AG, Oldenburg, WA, et al. 2003Effect of suprarenal versus infrarenal aortic endograft fixation on renal function and renal artery patency: a comparative study with intermediate follow-upJ Vasc Surg3711621168PubMed Lau, LL, Hakaim, AG, Oldenburg, WA,  et al. 2003Effect of suprarenal versus infrarenal aortic endograft fixation on renal function and renal artery patency: a comparative study with intermediate follow-upJ Vasc Surg3711621168PubMed
Metadata
Title
Suprarenal Endograft Fixation Avoids Adverse Outcomes Associated with Aortic Neck Angulation
Publication date
01-03-2005
Published in
Annals of Vascular Surgery / Issue 2/2005
Print ISSN: 0890-5096
Electronic ISSN: 1615-5947
DOI
https://doi.org/10.1007/s10016-004-0161-z

Other articles of this Issue 2/2005

Annals of Vascular Surgery 2/2005 Go to the issue

Papers Presented at the Twenty-ninth Annual Meeting of the Peripheral Vascular Surgery Society

Risk-Adjusted Analysis of Outcomes Following Elective Open Abdominal Aortic Aneurysm Repair