Skip to main content
Top
Published in: Clinical Oral Investigations 5/2019

01-05-2019 | Original Article

Cyclic fatigue of Reciproc Blue and Reciproc instruments exposed to intracanal temperature in simulated severe apical curvature

Authors: Uğur Inan, Cangül Keskin, Özlem Sivas Yilmaz, Gözde Baş

Published in: Clinical Oral Investigations | Issue 5/2019

Login to get access

Abstract

Objective

The aim of this study was to evaluate the cyclic fatigue resistance of Reciproc and Reciproc Blue by testing in a severe apical curvature at intracanal temperature.

Materials and methods

Eighteen Reciproc R25 (25.08) and Reciproc Blue (25.08) instruments were tested in a cyclic fatigue device at body temperature (37 °C) using a stainless steel block with an artificial canal with a curvature angle of 90° and radius of curvature of 2 mm. The number of cycles to fracture (NCF) was calculated. The instruments were examined by differential scanning calorimetry (DSC). The data were analyzed using both Student’s t tests and Weibull analysis.

Results

The NCF values of Reciproc R25 were significantly lower than Reciproc Blue R25 (P < 0.05). There was no significant difference between the instruments regarding the length of fractured fragments (P > 0.05).

Conclusions

Reciproc Blue R25 instruments displayed significantly higher NCF than Reciproc R25.

Clinical relevance

This study reported that novel reciprocating blue wire instruments exhibited higher cyclic fatigue resistance than its precedence M-wire instrument when tested in severely curvatured canals.
Literature
1.
go back to reference Glosson CR, Haller RH, Dove SB, Carlos E (1995) A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod 21:146–151CrossRef Glosson CR, Haller RH, Dove SB, Carlos E (1995) A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod 21:146–151CrossRef
2.
go back to reference Simon S, Machtou P, Tomson P, Adams N, Lumley P (2008) Influence of fractured instruments on the success rate of endodontic treatment. Dental Update 35:172–179CrossRefPubMed Simon S, Machtou P, Tomson P, Adams N, Lumley P (2008) Influence of fractured instruments on the success rate of endodontic treatment. Dental Update 35:172–179CrossRefPubMed
3.
go back to reference Walia H, Brantley WA, Gerstein H (1988) An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 14:346–351CrossRefPubMed Walia H, Brantley WA, Gerstein H (1988) An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 14:346–351CrossRefPubMed
4.
go back to reference Peters OA (2004) Current challenges and concepts in the preparation of root canal systems: a review. J Endod 30:559–567CrossRefPubMed Peters OA (2004) Current challenges and concepts in the preparation of root canal systems: a review. J Endod 30:559–567CrossRefPubMed
5.
go back to reference Tsujimoto M, Irifune Y, Tsujimoto Y, Yamada S, Watanabe I, Hayashi Y (2014) Comparison of conventional and new-generation nickel-titanium files in regard to their physical properties. J Endod 40:1824–1829CrossRefPubMed Tsujimoto M, Irifune Y, Tsujimoto Y, Yamada S, Watanabe I, Hayashi Y (2014) Comparison of conventional and new-generation nickel-titanium files in regard to their physical properties. J Endod 40:1824–1829CrossRefPubMed
6.
go back to reference Lopes HP, Elias CN, Vedovello GA, Bueno CE, Mangelli M, Siqueira JF (2011) Torsional resistance of retreatment instruments. J Endod 37:1442–1445CrossRefPubMed Lopes HP, Elias CN, Vedovello GA, Bueno CE, Mangelli M, Siqueira JF (2011) Torsional resistance of retreatment instruments. J Endod 37:1442–1445CrossRefPubMed
7.
go back to reference Shen Y, Cheung GS-P, Bian Z, Peng B (2006) Comparison of defects in ProFile and ProTaper systems after clinical use. J Endod 32:61–65CrossRefPubMed Shen Y, Cheung GS-P, Bian Z, Peng B (2006) Comparison of defects in ProFile and ProTaper systems after clinical use. J Endod 32:61–65CrossRefPubMed
8.
go back to reference Pruett JP, Clement DJ, Carnes DL (1997) Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 23:77–85CrossRefPubMed Pruett JP, Clement DJ, Carnes DL (1997) Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 23:77–85CrossRefPubMed
9.
go back to reference Yared G (2008) Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. Int Endod J 41:339–344CrossRefPubMed Yared G (2008) Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. Int Endod J 41:339–344CrossRefPubMed
11.
go back to reference De-Deus G, Silva EJNL, Vieira VTL, Belladonna FG, Elias CN, Plotino G et al (2017) Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the Reciproc files. J Endod 43:462–466CrossRefPubMed De-Deus G, Silva EJNL, Vieira VTL, Belladonna FG, Elias CN, Plotino G et al (2017) Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the Reciproc files. J Endod 43:462–466CrossRefPubMed
12.
go back to reference Keskin C, İnan U, Demiral M, Keleş A (2017) Cyclic fatigue resistance of Reciproc Blue, Reciproc and WaveOne Gold reciprocating instruments. J Endod 43:1360–1363CrossRefPubMed Keskin C, İnan U, Demiral M, Keleş A (2017) Cyclic fatigue resistance of Reciproc Blue, Reciproc and WaveOne Gold reciprocating instruments. J Endod 43:1360–1363CrossRefPubMed
13.
go back to reference Plotino G, Grande NM, Bellido MM, Testarelli L, Gambarini G (2017) Influence of temperature on cyclic fatigue resistance of ProTaper Gold and ProTaper Universal rotary files. J Endod 43:200–202CrossRefPubMed Plotino G, Grande NM, Bellido MM, Testarelli L, Gambarini G (2017) Influence of temperature on cyclic fatigue resistance of ProTaper Gold and ProTaper Universal rotary files. J Endod 43:200–202CrossRefPubMed
14.
go back to reference de Vasconcelos RA, Murphy S, Carvalho CAT, Govindjee RG, Govindjee S, Peters OA (2016) Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature. J Endod 42:782–787CrossRefPubMed de Vasconcelos RA, Murphy S, Carvalho CAT, Govindjee RG, Govindjee S, Peters OA (2016) Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature. J Endod 42:782–787CrossRefPubMed
15.
go back to reference Dosanjh A, Paurazas S, Askar M (2017) The effect of temperature on cyclic fatigue of nickel-titanium rotary endodontic instruments. J Endod 43:823–826CrossRefPubMed Dosanjh A, Paurazas S, Askar M (2017) The effect of temperature on cyclic fatigue of nickel-titanium rotary endodontic instruments. J Endod 43:823–826CrossRefPubMed
16.
go back to reference Haikel Y, Serfaty R, Bateman G, Senger B, Allemann C (1999) Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod 25:434–440CrossRefPubMed Haikel Y, Serfaty R, Bateman G, Senger B, Allemann C (1999) Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod 25:434–440CrossRefPubMed
17.
go back to reference Plotino G, Grande N, Melo M, Bahia M, Testarelli L, Gambarini G (2010) Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvature. Int Endod J 43:226–230CrossRefPubMed Plotino G, Grande N, Melo M, Bahia M, Testarelli L, Gambarini G (2010) Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvature. Int Endod J 43:226–230CrossRefPubMed
18.
go back to reference Keskin C, İnan U, Güler DH, Kalyoncuoğlu E (2018) Cyclic fatigue resistance of XP-Endo Shaper, K3XF and ProTaper Gold nickel-titanium instruments. J Endod 44:1164–1167CrossRefPubMed Keskin C, İnan U, Güler DH, Kalyoncuoğlu E (2018) Cyclic fatigue resistance of XP-Endo Shaper, K3XF and ProTaper Gold nickel-titanium instruments. J Endod 44:1164–1167CrossRefPubMed
19.
go back to reference Weibull W (1951) A statistical distribution function of wide applicability. J Appl Mech 128:293–297 Weibull W (1951) A statistical distribution function of wide applicability. J Appl Mech 128:293–297
20.
go back to reference Nguyen HH, Fong H, Paranjpe A, Flake NM, Johnson JD, Peters OA (2014) Evaluation of the resistance to cyclic fatigue among ProTaper Next, ProTaper Universal, and Vortex Blue rotary instruments. J Endod 40:1190–1193CrossRefPubMed Nguyen HH, Fong H, Paranjpe A, Flake NM, Johnson JD, Peters OA (2014) Evaluation of the resistance to cyclic fatigue among ProTaper Next, ProTaper Universal, and Vortex Blue rotary instruments. J Endod 40:1190–1193CrossRefPubMed
21.
go back to reference Topçuoğlu HS, Topçuoğlu G (2017) Cyclic fatigue resistance of Reciproc Blue and Reciproc files in an S-shaped canal. J Endod 43:1679–1682CrossRefPubMed Topçuoğlu HS, Topçuoğlu G (2017) Cyclic fatigue resistance of Reciproc Blue and Reciproc files in an S-shaped canal. J Endod 43:1679–1682CrossRefPubMed
23.
go back to reference Schilder H (1974) Cleaning and shaping the root canal. Dent Clin N Am 18:269–296PubMed Schilder H (1974) Cleaning and shaping the root canal. Dent Clin N Am 18:269–296PubMed
24.
go back to reference Willershausen B, Kasaj A, Röhrig B, Marroquin BB (2008) Radiographic investigation of frequency and location of root canal curvatures in human mandibular anterior incisors in vitro. J Endod 34:152–156CrossRefPubMed Willershausen B, Kasaj A, Röhrig B, Marroquin BB (2008) Radiographic investigation of frequency and location of root canal curvatures in human mandibular anterior incisors in vitro. J Endod 34:152–156CrossRefPubMed
25.
go back to reference Silva EJNG, Vieira VTL, Hecksher F, Oliveira MRSS, Antunes HS, Moreira EJL (2018) Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments. Clin Oral Investig 22:2633–2638CrossRefPubMed Silva EJNG, Vieira VTL, Hecksher F, Oliveira MRSS, Antunes HS, Moreira EJL (2018) Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments. Clin Oral Investig 22:2633–2638CrossRefPubMed
26.
go back to reference Elsaka SE, Elnaghy AM (2015) Cyclic fatigue resistance of OneShape and WaveOne instruments using different angles of curvature. Dent Mater J 34:358–363CrossRefPubMed Elsaka SE, Elnaghy AM (2015) Cyclic fatigue resistance of OneShape and WaveOne instruments using different angles of curvature. Dent Mater J 34:358–363CrossRefPubMed
27.
go back to reference Shen Y, Zhou H, Coil JM, Aljazaeri B, Buttar R, Wang Z, Zheng YF, Haapasalo M (2015) ProFile Vortex and Vortex Blue nickel-titanium rotary instruments after clinical use. J Endod 41:937–942CrossRefPubMed Shen Y, Zhou H, Coil JM, Aljazaeri B, Buttar R, Wang Z, Zheng YF, Haapasalo M (2015) ProFile Vortex and Vortex Blue nickel-titanium rotary instruments after clinical use. J Endod 41:937–942CrossRefPubMed
28.
go back to reference Santoro M, Nicolay OF, Cangialosi TJ (2001) Pseudoelasticity and thermoelasticity of nickel-titanium alloys: a clinically oriented review. Part I: temperature transitional ranges. Am J Orthod Dentofac Orthop 119:587–593CrossRef Santoro M, Nicolay OF, Cangialosi TJ (2001) Pseudoelasticity and thermoelasticity of nickel-titanium alloys: a clinically oriented review. Part I: temperature transitional ranges. Am J Orthod Dentofac Orthop 119:587–593CrossRef
29.
go back to reference Shim KS, Oh S, Kum K, Kim YC, Jee KK, Chang SW (2017) Mechanical and metallurgical properties of various nickel-titanium rotary instruments. Biomed Res Int 4528601:1–13CrossRef Shim KS, Oh S, Kum K, Kim YC, Jee KK, Chang SW (2017) Mechanical and metallurgical properties of various nickel-titanium rotary instruments. Biomed Res Int 4528601:1–13CrossRef
30.
go back to reference Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D (2012) Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments. J Endod 38:398–401CrossRefPubMed Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D (2012) Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments. J Endod 38:398–401CrossRefPubMed
Metadata
Title
Cyclic fatigue of Reciproc Blue and Reciproc instruments exposed to intracanal temperature in simulated severe apical curvature
Authors
Uğur Inan
Cangül Keskin
Özlem Sivas Yilmaz
Gözde Baş
Publication date
01-05-2019
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 5/2019
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-018-2631-7

Other articles of this Issue 5/2019

Clinical Oral Investigations 5/2019 Go to the issue