Skip to main content
Top
Published in: Clinical Oral Investigations 7/2017

01-09-2017 | Original Article

Impact of abutment material on peri-implant soft tissue color. An in vitro study

Authors: Leticia Sala, Antonio Bascones-Martínez, Ana Carrillo-de-Albornoz

Published in: Clinical Oral Investigations | Issue 7/2017

Login to get access

Abstract

Objectives

The objectives of the present study is to determine the differences in peri-implant soft tissue color with the utilization of titanium, titanium gold-plated, white zirconia, Vita Classical (VC) A4-shaded zirconia, and fluorescent white zirconia abutments and to establish the influence of gingival thickness on the resulting color.

Methods

Four implants were contralaterally inserted in 19 fresh pig mandibles, and the color of the peri-implant mucosa with the different abutments was spectrophotometrically measured at 1-, 2-, and 3-mm height from the margin.

Results

At 1-mm height, titanium significantly differed from all zirconia abutments in lightness (L*), chroma along red axis (a*), and chroma along yellow-blue axis (b*) parameters. At 2 mm, all zirconia abutments differed from titanium in b* but only fluorescent zirconia in a*. At 3 mm, titanium differed from VC A4-shaded and fluorescent zirconia abutments in b*. At soft tissue thicknesses <1 and 1–2 mm, titanium differed from fluorescent zirconia in a* and b* and from VC A4-shaded zirconia in b*; at thickness >2 mm, no differences were found among abutments. All abutments differed from natural teeth in a* and b* at all heights and thicknesses except for fluorescent zirconia at thickness >2 mm. The Euclidean distance (ΔΕ) differed between titanium abutments and gold, VC A4, and fluorescent zirconia at <1- and 1–2-mm thicknesses.

Conclusion

The natural gingival color was not reproduced with any abutment at gingival thicknesses <2 mm. The worst color match was with titanium abutments and the best with fluorescent zirconia, followed by VC A4-shaded zirconia. At gingival thicknesses >2 mm, no differences were detected among abutments.

Clinical relevance

This study demonstrates that the type of abutment and the gingival thickness affect the resulting peri-implant gingival color.
Literature
2.
go back to reference Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS (2012) Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res 23:2–21. doi:10.1111/j.1600-0501.2012.02547.x CrossRefPubMed Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS (2012) Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res 23:2–21. doi:10.​1111/​j.​1600-0501.​2012.​02547.​x CrossRefPubMed
4.
go back to reference Garber DA (1996) The esthetic dental implant: letting restoration be the guide. J Oral Implantol 22:45–50PubMed Garber DA (1996) The esthetic dental implant: letting restoration be the guide. J Oral Implantol 22:45–50PubMed
5.
go back to reference Chang M, Odman PA, Wennström JL, Andersson B (1999) Esthetic outcome of implant-supported single-tooth replacements assessed by the patient and by prosthodontists. Int J Prosthodont 12:335–341PubMed Chang M, Odman PA, Wennström JL, Andersson B (1999) Esthetic outcome of implant-supported single-tooth replacements assessed by the patient and by prosthodontists. Int J Prosthodont 12:335–341PubMed
7.
go back to reference Andersson B, Taylor A, Lang BR, Scheller H, Scharer P, Sorensen JA, Tarnow D (2001) Alumina ceramic implant abutments used for single tooth replacement: a prospective 1 to 3 year multicenter study. The Int J Prosthodont 14:432–438PubMed Andersson B, Taylor A, Lang BR, Scheller H, Scharer P, Sorensen JA, Tarnow D (2001) Alumina ceramic implant abutments used for single tooth replacement: a prospective 1 to 3 year multicenter study. The Int J Prosthodont 14:432–438PubMed
9.
go back to reference Watkin A, Kerstein RB (2008) Improving darkened anterior peri-implant tissue color with zirconia custom implant abutments. Compendium 29:238–242PubMed Watkin A, Kerstein RB (2008) Improving darkened anterior peri-implant tissue color with zirconia custom implant abutments. Compendium 29:238–242PubMed
10.
go back to reference Canullo L (2007) Clinical outcome study of customized zirconia abutments for single implant restorations. Int J Prosthodont 20:489–493PubMed Canullo L (2007) Clinical outcome study of customized zirconia abutments for single implant restorations. Int J Prosthodont 20:489–493PubMed
11.
go back to reference Nakamura K, Kanno T, Milleding P, Ortegren U (2010) Zirconia as a dental implant abutment material: a systematic review. Int J Prosthodont 23:299–309PubMed Nakamura K, Kanno T, Milleding P, Ortegren U (2010) Zirconia as a dental implant abutment material: a systematic review. Int J Prosthodont 23:299–309PubMed
12.
go back to reference Sailer I, Zembic A, Jung R, Hämmerle CHF, Mattiola A (2007) Single tooth implant reconstructions: esthetic factors influencing the decision between titanium and zirconia abutments in anterior regions. Eur J Esthet Dent 2:296–310PubMed Sailer I, Zembic A, Jung R, Hämmerle CHF, Mattiola A (2007) Single tooth implant reconstructions: esthetic factors influencing the decision between titanium and zirconia abutments in anterior regions. Eur J Esthet Dent 2:296–310PubMed
13.
go back to reference Zembic A, Bösch A, Jung RE, Hämmerle CHF, Sailer I (2013) Five-year results of a randomized controlled clinical trial comparing zirconia and titanium abutments supporting single-implant crowns in canine and posterior regions. Clin Oral Impl Res 24:384–390. doi:10.1111/clr.12044 CrossRef Zembic A, Bösch A, Jung RE, Hämmerle CHF, Sailer I (2013) Five-year results of a randomized controlled clinical trial comparing zirconia and titanium abutments supporting single-implant crowns in canine and posterior regions. Clin Oral Impl Res 24:384–390. doi:10.​1111/​clr.​12044 CrossRef
14.
go back to reference Jung RE, Sailer I, Hämmerle CHF (2008) The effect of all ceramic and porcelain fused to metal restorations on marginal peri-implant soft tissue color: a randomized controlled clinical trial. Int J Periodontics Restorative Dent 28:356–365 Jung RE, Sailer I, Hämmerle CHF (2008) The effect of all ceramic and porcelain fused to metal restorations on marginal peri-implant soft tissue color: a randomized controlled clinical trial. Int J Periodontics Restorative Dent 28:356–365
15.
16.
go back to reference Carrillo de Albornoz A, Vignoletti F, Ferrantino L, Cárdenas E, De Sanctis M, Sanz M (2014) A randomised trial on the aesthetic outcome of implant supported restorations with zirconia or titanium abutments. J Clin Periodontol 41:1161–1169. doi:10.1111/jcpe.12312 CrossRefPubMed Carrillo de Albornoz A, Vignoletti F, Ferrantino L, Cárdenas E, De Sanctis M, Sanz M (2014) A randomised trial on the aesthetic outcome of implant supported restorations with zirconia or titanium abutments. J Clin Periodontol 41:1161–1169. doi:10.​1111/​jcpe.​12312 CrossRefPubMed
17.
go back to reference Sailer I, Pjetursson BE, Zwahlen M, Hämmerle CHF (2009) A systematic review of the survival and complication rates of all ceramics and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses. Clin Oral Impl Res 18:86–96. doi:10.1111/j.1600-0501.2009.01787.x CrossRef Sailer I, Pjetursson BE, Zwahlen M, Hämmerle CHF (2009) A systematic review of the survival and complication rates of all ceramics and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses. Clin Oral Impl Res 18:86–96. doi:10.​1111/​j.​1600-0501.​2009.​01787.​x CrossRef
18.
go back to reference Happe A, Schulte-Mattler V, Naumann M, Zöller J, Rothamel D (2011) Spectrophotometric assessment of peri-implant mucosa after restoration with zirconia abutments veneered with fluorescent ceramic: a controlled, retrospective clinical study. Clin Oral Impl Res 24:28–33CrossRef Happe A, Schulte-Mattler V, Naumann M, Zöller J, Rothamel D (2011) Spectrophotometric assessment of peri-implant mucosa after restoration with zirconia abutments veneered with fluorescent ceramic: a controlled, retrospective clinical study. Clin Oral Impl Res 24:28–33CrossRef
19.
go back to reference Happe A, Schulte-Mattler V, Strassert C, Naumann M, Zöller JE, Rothamenl D (2013) In vitro color changes of soft tissues caused by dyed fluorescent zirconia and nondyed, nonfluorescent zirconia in thin mucosa. Int J Periodontics Restorative Dent 33:1–8. doi:10.1111/j.1600-0501.2011.02361.x CrossRef Happe A, Schulte-Mattler V, Strassert C, Naumann M, Zöller JE, Rothamenl D (2013) In vitro color changes of soft tissues caused by dyed fluorescent zirconia and nondyed, nonfluorescent zirconia in thin mucosa. Int J Periodontics Restorative Dent 33:1–8. doi:10.​1111/​j.​1600-0501.​2011.​02361.​x CrossRef
21.
go back to reference Sykaras N, Iacopino AM, Marker VA, Triplett RG, Woody RD (2000) Implant materials, designs, and surfaces topographies: their effect on osseointegration. A literature review J Maxillofac Oral Surg 15:675–690 Sykaras N, Iacopino AM, Marker VA, Triplett RG, Woody RD (2000) Implant materials, designs, and surfaces topographies: their effect on osseointegration. A literature review J Maxillofac Oral Surg 15:675–690
22.
go back to reference Jung RE, Sailer I, Hämmerle CHF, Attin T, Schmidlin P (2007) In vitro color changes of soft tissues caused by restorative materials. Int J Periodontics Restorative Dent 27:250–257 Jung RE, Sailer I, Hämmerle CHF, Attin T, Schmidlin P (2007) In vitro color changes of soft tissues caused by restorative materials. Int J Periodontics Restorative Dent 27:250–257
23.
go back to reference Pecnik MC, Roos M, Muff D, Spolenak R, Sailer I (2014) In vitro evaluation of esthetic coatings for metallic dental implants and implant prosthetic appliances. Clil Oral Impl Res 26:563–571CrossRef Pecnik MC, Roos M, Muff D, Spolenak R, Sailer I (2014) In vitro evaluation of esthetic coatings for metallic dental implants and implant prosthetic appliances. Clil Oral Impl Res 26:563–571CrossRef
24.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
26.
go back to reference Kuehni RG, Marcus RT (1979) An experimental in visual scaling of small colour differences. Color Res Appl 4:83–91 Kuehni RG, Marcus RT (1979) An experimental in visual scaling of small colour differences. Color Res Appl 4:83–91
27.
go back to reference Sala L, Carrillo de Albornoz A, Martin C, Bascones-Martínez A (2015) Factors involved in the spectrophotometric measurement of soft tissue: a clinical study of interrater and intrarater reliability. J Prosthet Dent 113:558–564CrossRefPubMed Sala L, Carrillo de Albornoz A, Martin C, Bascones-Martínez A (2015) Factors involved in the spectrophotometric measurement of soft tissue: a clinical study of interrater and intrarater reliability. J Prosthet Dent 113:558–564CrossRefPubMed
29.
go back to reference Commission Internationale de l’Éclairage (CIE) (2004) Colorimetry. CIE Publication 15.2. 3rd ed. Vienna: Central Bureau of the CIE Commission Internationale de l’Éclairage (CIE) (2004) Colorimetry. CIE Publication 15.2. 3rd ed. Vienna: Central Bureau of the CIE
30.
go back to reference Benic G, Scherrer D, Sancho-Puchades M, Thoma D, Hämmerle CHF (2016) Spectrophotometric and visual evaluation of peri-implant soft tissue color. Clin Oral Impl Res 5:1–9. doi:10.1111/clr.12781 Benic G, Scherrer D, Sancho-Puchades M, Thoma D, Hämmerle CHF (2016) Spectrophotometric and visual evaluation of peri-implant soft tissue color. Clin Oral Impl Res 5:1–9. doi:10.​1111/​clr.​12781
31.
go back to reference Paniz G, Bressan E, Stellini E, Romeo E, Lops D (2014) Correlation between subjective and objective evaluation of peri-implant soft tissue color. Clin Oral Impl Res 25:992–996. doi:10.1111/clr.12201 CrossRef Paniz G, Bressan E, Stellini E, Romeo E, Lops D (2014) Correlation between subjective and objective evaluation of peri-implant soft tissue color. Clin Oral Impl Res 25:992–996. doi:10.​1111/​clr.​12201 CrossRef
32.
go back to reference Cosgarea R, Gasparik C, Dudea D, Culic B, Dannewitz B, Sculean A (2015) Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study. Clin Oral Impl Res 26:537–544. doi:10.1111/clr.12440 CrossRef Cosgarea R, Gasparik C, Dudea D, Culic B, Dannewitz B, Sculean A (2015) Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study. Clin Oral Impl Res 26:537–544. doi:10.​1111/​clr.​12440 CrossRef
33.
go back to reference Kim A, Campbell SD, Viana MA, Knoernschild KL (2015) Abutment material on peri-implant soft tissue color and perceived esthetics. J Prosthod 23:1–7. doi:10.1111/jopr.12360 Kim A, Campbell SD, Viana MA, Knoernschild KL (2015) Abutment material on peri-implant soft tissue color and perceived esthetics. J Prosthod 23:1–7. doi:10.​1111/​jopr.​12360
34.
go back to reference Ioannidis A, Cathomen E, Jung R, Fehmer V, Hüsler J, Thoma D (2016) Discoloration of the mucosa caused by different restorative materials—a spectrophotometric in vitro study. Clin Oral Impl Res 25:1–6. doi:10.1111/clr.12928 Ioannidis A, Cathomen E, Jung R, Fehmer V, Hüsler J, Thoma D (2016) Discoloration of the mucosa caused by different restorative materials—a spectrophotometric in vitro study. Clin Oral Impl Res 25:1–6. doi:10.​1111/​clr.​12928
35.
go back to reference Linkevicius T, Vaitelis T (2015) The effect of zirconia or titanium as abutment material on soft peri-implant tissues: a systematic review and meta-analysis. Clin Oral Impl Res 26:139–147. doi:10.1111/clr.12631 CrossRef Linkevicius T, Vaitelis T (2015) The effect of zirconia or titanium as abutment material on soft peri-implant tissues: a systematic review and meta-analysis. Clin Oral Impl Res 26:139–147. doi:10.​1111/​clr.​12631 CrossRef
36.
go back to reference Sicilia A, Quirynen M, Fontolliet A et al (2015) Long-term stability of peri-implant tissues after bone or soft tissue augmentation. Effect of zirconia or titanium abutments on peri-implant soft tissues. Summary and consensus statements. The 4th EAO consensus conference. Clin Oral Impl Res 26:148–152. doi:10.1111/clr.12676 CrossRef Sicilia A, Quirynen M, Fontolliet A et al (2015) Long-term stability of peri-implant tissues after bone or soft tissue augmentation. Effect of zirconia or titanium abutments on peri-implant soft tissues. Summary and consensus statements. The 4th EAO consensus conference. Clin Oral Impl Res 26:148–152. doi:10.​1111/​clr.​12676 CrossRef
40.
go back to reference Sailer I, Fehmer V, Ioannidis A, Hämmerle CHF, Thoma D (2014) Threshold value for the perception of color changes of human gingiva. Int J Periodontics Restorative Dent 34:757–762CrossRefPubMed Sailer I, Fehmer V, Ioannidis A, Hämmerle CHF, Thoma D (2014) Threshold value for the perception of color changes of human gingiva. Int J Periodontics Restorative Dent 34:757–762CrossRefPubMed
41.
go back to reference Johnston WM, Kao EC (1989) Assessment of appearance match by visual observation and clinical colorimetry. J Den Res 68:819–822CrossRef Johnston WM, Kao EC (1989) Assessment of appearance match by visual observation and clinical colorimetry. J Den Res 68:819–822CrossRef
42.
go back to reference Lesch CA, Squier CA, Cruchley A, Williams DM, Speight P (1989) The permeability of human oral mucosa and skin to water. J Dent Res 68:1345–1349CrossRefPubMed Lesch CA, Squier CA, Cruchley A, Williams DM, Speight P (1989) The permeability of human oral mucosa and skin to water. J Dent Res 68:1345–1349CrossRefPubMed
43.
go back to reference Van Eyk AD, Van der Bijl P (2004) Comparative permeability of various chemical markers through human vaginal and buccal mucosa as well as porcine buccal and mouth floor mucosa. Arch Oral Biol 49:387–392CrossRefPubMed Van Eyk AD, Van der Bijl P (2004) Comparative permeability of various chemical markers through human vaginal and buccal mucosa as well as porcine buccal and mouth floor mucosa. Arch Oral Biol 49:387–392CrossRefPubMed
46.
go back to reference Kleinheinz J, Büchter A, Fillies T, Joos U (2005) Vascular basis of mucosa color. Head Face Med 24:1–4 Kleinheinz J, Büchter A, Fillies T, Joos U (2005) Vascular basis of mucosa color. Head Face Med 24:1–4
Metadata
Title
Impact of abutment material on peri-implant soft tissue color. An in vitro study
Authors
Leticia Sala
Antonio Bascones-Martínez
Ana Carrillo-de-Albornoz
Publication date
01-09-2017
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 7/2017
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-016-2015-9

Other articles of this Issue 7/2017

Clinical Oral Investigations 7/2017 Go to the issue