Published in: Clinical Oral Investigations 4/2017

01-05-2017 | Original Article

Clinical evaluation of composite restorations in Er:YAG laser-prepared cavities re-wetting with chlorhexidine

Authors: Daniel Galafassi, Camila Scatena, Rodrigo Galo, Fabiana Almeida Curylofo-Zotti, Silmara Aparecida Milori Corona, Maria Cristina Borsatto

Published in: Clinical Oral Investigations | Issue 4/2017

Login to get access

Abstract

Objectives

The objective of this study was to evaluate longitudinally the composite restorations, performed in cavities prepared by Er:YAG or conventional bur, and dentin re-wetting with water or chlorhexidine.

Materials and methods

Twenty individuals with four active caries with cavitation reaching the dentin located on the occlusal surface of molars counterparts are selected. The teeth of each individual were randomly assigned into four groups: (I) Er:YAG laser (260 mJ/4 Hz) re-wetting with chlorhexidine, (II) Er:YAG laser (260 mJ/4 Hz) re-wetting with deionized water, (III) conventional method re-wetting with chlorhexidine, and (IV) conventional method re-wetting with deionized water. The teeth were isolated, prepared cavities, phosphoric acid etching, and re-wetting according to previously assigned method. Restoration was performed employing the Single Bond 2 and Z350XT resin. Clinical follow-up was held after the polishing of the restoration (baseline) and 6 and 12 months of the making of the restoration using the modified USPHS criteria. The restorations were qualitatively analyzed by means of photographs. In the evaluation period, replicas of the restorations were analyzed by SEM. Data were analyzed by statistics using chi-square test (p < 0.05).

Results

After 12 months of clinical evaluation, groups prepared with laser and re-wetting with chlorhexidine and water showed the lowest marginal staining value. There was no statistical difference between the groups for other factors. SEM analysis revealed that a non-expressive amount of restorations showed gaps and irregularities of tooth-restoration interface after 6 and 12 months compared to the baseline.

Conclusion

The restorations performed in laser-prepared cavities, regardless of the re-wetting, presented the best clinical performance over the evaluated period.

Clinical relevance

Laser-prepared teeth, regardless of re-wetting, showed greater resistance to marginal discoloration.
Literature
1.
go back to reference Aoki A, Ishikawa I, Yamada T, Otsuki M, Watanabe H, Tagami J, Ando Y, Yamamoto H (1998) Comparison between Er:YAG laser and conventional technique for root caries in vitro. J Dent Res 77:1404–1414CrossRefPubMed Aoki A, Ishikawa I, Yamada T, Otsuki M, Watanabe H, Tagami J, Ando Y, Yamamoto H (1998) Comparison between Er:YAG laser and conventional technique for root caries in vitro. J Dent Res 77:1404–1414CrossRefPubMed
2.
go back to reference Sattabanasuk V, Burrow MF, Shimada Y, Tagami J (2006) Resin adhesion to caries-affected dentine after different removal methods. Aust Dent J 51:162–169CrossRefPubMed Sattabanasuk V, Burrow MF, Shimada Y, Tagami J (2006) Resin adhesion to caries-affected dentine after different removal methods. Aust Dent J 51:162–169CrossRefPubMed
3.
go back to reference Armengol V, Jean A, Marion D (2000) Temperature rise during Er:YAG and Nd:YAP laser ablation of dentin. J Endod 26:138–141CrossRefPubMed Armengol V, Jean A, Marion D (2000) Temperature rise during Er:YAG and Nd:YAP laser ablation of dentin. J Endod 26:138–141CrossRefPubMed
4.
go back to reference De Munck J, Van Meerbeek B, Yudhira R, Lambrechts P, Vanherle G (2002) Micro-tensile bond strength of two adhesives to erbium: YAG-lased vs. bur-cut enamel and dentin. Eur J Oral Sci 110:322–329CrossRefPubMed De Munck J, Van Meerbeek B, Yudhira R, Lambrechts P, Vanherle G (2002) Micro-tensile bond strength of two adhesives to erbium: YAG-lased vs. bur-cut enamel and dentin. Eur J Oral Sci 110:322–329CrossRefPubMed
5.
go back to reference Van Meerbeek B, De Munck J, Mattar D, Van Landuyt K, Lambrechts P (2003) Microtensile bond strengths of an etch & rinse and self-etch adhesive to enamel and dentin as a function of surface treatment. Oper Dent 28:647–660PubMed Van Meerbeek B, De Munck J, Mattar D, Van Landuyt K, Lambrechts P (2003) Microtensile bond strengths of an etch & rinse and self-etch adhesive to enamel and dentin as a function of surface treatment. Oper Dent 28:647–660PubMed
6.
go back to reference Hibst RJ (2002) Lasers for caries removal and cavity preparation: state of the art and future directions. J Oral Laser Appl 2:203–211 Hibst RJ (2002) Lasers for caries removal and cavity preparation: state of the art and future directions. J Oral Laser Appl 2:203–211
7.
go back to reference Keller U, Hibst R, Geurtsen W, Schilke R, Heidmann D, Klaiber B, Raab WH (1988) Erbium:YAG laser application in caries therapy. Evaluation of patient perception and acceptance. J Dent 26:649–656CrossRef Keller U, Hibst R, Geurtsen W, Schilke R, Heidmann D, Klaiber B, Raab WH (1988) Erbium:YAG laser application in caries therapy. Evaluation of patient perception and acceptance. J Dent 26:649–656CrossRef
8.
go back to reference Corona SAM, Souza AE, Chinelatti MA, Pécora JD, Borsatto MC, Palma-Dibb RG (2007) Effect of energy and pulse repetition rate of Er: YAG laser on dentin ablation ability and morphological analysis of the laser-irradiated substrate. Photomed Lasers Surg 25:26–33CrossRef Corona SAM, Souza AE, Chinelatti MA, Pécora JD, Borsatto MC, Palma-Dibb RG (2007) Effect of energy and pulse repetition rate of Er: YAG laser on dentin ablation ability and morphological analysis of the laser-irradiated substrate. Photomed Lasers Surg 25:26–33CrossRef
9.
go back to reference Corona SAM, Souza-Gabriel AE, Chinelatti MA, Pécora JD, Borsatto MC, Palma-Dibb RG (2008) Influence of energy and pulse repetition rate of Er:YAG laser on enamel ablation ability and morphological analysis of the laser-irradiated surface. J Biomed Mat Res 84:569–575CrossRef Corona SAM, Souza-Gabriel AE, Chinelatti MA, Pécora JD, Borsatto MC, Palma-Dibb RG (2008) Influence of energy and pulse repetition rate of Er:YAG laser on enamel ablation ability and morphological analysis of the laser-irradiated surface. J Biomed Mat Res 84:569–575CrossRef
10.
go back to reference Colucci V, Amaral FLB, Palma-Dibb RG, Pécora JD, Corona SAM (2009) Water flow on erbium:yttrium-aluminum-garnet laser irradiation: effects on dental tissues. Lasers Med Sci 24:811–818CrossRefPubMed Colucci V, Amaral FLB, Palma-Dibb RG, Pécora JD, Corona SAM (2009) Water flow on erbium:yttrium-aluminum-garnet laser irradiation: effects on dental tissues. Lasers Med Sci 24:811–818CrossRefPubMed
11.
go back to reference Hibst R, Keller U (1989) Experimental studies of the application of the Er:YAG laser on dental hard substances: I. Measurement of the ablation rate. Lasers Surg Med 9:338–344CrossRefPubMed Hibst R, Keller U (1989) Experimental studies of the application of the Er:YAG laser on dental hard substances: I. Measurement of the ablation rate. Lasers Surg Med 9:338–344CrossRefPubMed
12.
go back to reference Ramos RP, Palma Dibb RG, Chimello DT, Chinelatti MA, Pécora JD (2002) Effect of Er:YAG laser on bond strength to dentin of a self-etching primer and two single-bottle adhesive systems. Laser Surg Med 31:164–170CrossRef Ramos RP, Palma Dibb RG, Chimello DT, Chinelatti MA, Pécora JD (2002) Effect of Er:YAG laser on bond strength to dentin of a self-etching primer and two single-bottle adhesive systems. Laser Surg Med 31:164–170CrossRef
13.
go back to reference Matsumoto K, Nakamura Y, Makesi K, Kimura Y (1996) Clinical dental application of Er:YAG laser for class V cavity preparation. J Clinic Laser Med Surg 14:123–127 Matsumoto K, Nakamura Y, Makesi K, Kimura Y (1996) Clinical dental application of Er:YAG laser for class V cavity preparation. J Clinic Laser Med Surg 14:123–127
14.
go back to reference Hossain M, Nakamura Y, Yamada Y, Kimura Y, Nakamura G, Matsumoto K (1999) Ablation depths and morphological changes in human enamel and dentin after Er:YAG laser irradiation with or without water mist. J Clin Las Med Surg 17:105–109 Hossain M, Nakamura Y, Yamada Y, Kimura Y, Nakamura G, Matsumoto K (1999) Ablation depths and morphological changes in human enamel and dentin after Er:YAG laser irradiation with or without water mist. J Clin Las Med Surg 17:105–109
15.
go back to reference Lopes RM, Trevelin LT, da Cunha SR, de Oliveira RF, de Andrade Salgado DM, de Freitas PM, de Paula EC, Aranha AC (2015) Dental adhesion to erbium-lased tooth structure: a review of the literature. Photomed Laser Surg 33:393–403CrossRefPubMed Lopes RM, Trevelin LT, da Cunha SR, de Oliveira RF, de Andrade Salgado DM, de Freitas PM, de Paula EC, Aranha AC (2015) Dental adhesion to erbium-lased tooth structure: a review of the literature. Photomed Laser Surg 33:393–403CrossRefPubMed
16.
go back to reference Shahabi S, Chiniforush N, Bahramian H, Monzavi A, Baghalian A, Kharazifard MJ (2013) The effect of erbium family laser on tensile bond strength of composite to dentin in comparison with conventional method. Lasers Med Sci 28:139–142CrossRefPubMed Shahabi S, Chiniforush N, Bahramian H, Monzavi A, Baghalian A, Kharazifard MJ (2013) The effect of erbium family laser on tensile bond strength of composite to dentin in comparison with conventional method. Lasers Med Sci 28:139–142CrossRefPubMed
17.
go back to reference Sirin Karaarslan E, Yildiz E, Cebe MA, Yegin Z, Ozturk B (2012) Evaluation of micro-tensile bond strength of caries-affected human dentine after three different caries removal techniques. J Dent 40:793–801CrossRefPubMed Sirin Karaarslan E, Yildiz E, Cebe MA, Yegin Z, Ozturk B (2012) Evaluation of micro-tensile bond strength of caries-affected human dentine after three different caries removal techniques. J Dent 40:793–801CrossRefPubMed
18.
go back to reference Akin GE, Herguner–Siso S, Ozcan M, Ozel–Bektas O, Akin H (2012) Bond strengths of one-step self-etch adhesives to laser-irradiated and bur-cut dentin after water storage and thermocycling. Photomed Laser Surg 30:214–221CrossRefPubMed Akin GE, Herguner–Siso S, Ozcan M, Ozel–Bektas O, Akin H (2012) Bond strengths of one-step self-etch adhesives to laser-irradiated and bur-cut dentin after water storage and thermocycling. Photomed Laser Surg 30:214–221CrossRefPubMed
19.
go back to reference Amaral FL, Colucci V, Souza–Gabriel AE, Chinelatti MA, Palma–Dibb RG, Corona AS (2010) Bond durability in erbium: yttrium-aluminum-garnet laser-irradiated enamel. Lasers Med Sci 25:155–163CrossRefPubMed Amaral FL, Colucci V, Souza–Gabriel AE, Chinelatti MA, Palma–Dibb RG, Corona AS (2010) Bond durability in erbium: yttrium-aluminum-garnet laser-irradiated enamel. Lasers Med Sci 25:155–163CrossRefPubMed
20.
go back to reference Ergücü Z, Celik EU, Unlü N, Türkün M, Ozer F (2009) Effect of Er, Cr:YSGG laser on the microtensile bond strength of two different adhesives to the sound and caries-affected dentin. Oper Dent 34:460–466CrossRefPubMed Ergücü Z, Celik EU, Unlü N, Türkün M, Ozer F (2009) Effect of Er, Cr:YSGG laser on the microtensile bond strength of two different adhesives to the sound and caries-affected dentin. Oper Dent 34:460–466CrossRefPubMed
21.
go back to reference da Silva MP, Barceleiro MO, Dias KR, Zanin F (2011) Shear bond strength of two adhesive systems bonded to Er:YAG laserprepared dentin. Gen Dent 59:96–100 da Silva MP, Barceleiro MO, Dias KR, Zanin F (2011) Shear bond strength of two adhesive systems bonded to Er:YAG laserprepared dentin. Gen Dent 59:96–100
22.
go back to reference Martinez-Insua A, Da Silva DL, Rivera FG, Santana-Penin UA (2000) Differences in bonding to acid-etched or Er: YAG-laser-treated enamel and dentin surfaces. J Prosthet Dent 84:280–288CrossRefPubMed Martinez-Insua A, Da Silva DL, Rivera FG, Santana-Penin UA (2000) Differences in bonding to acid-etched or Er: YAG-laser-treated enamel and dentin surfaces. J Prosthet Dent 84:280–288CrossRefPubMed
23.
go back to reference Ceballos L, Osorio R, Toledano M, Tay F, Marshall GW (2002) Bonding to Er:YAG laser treated dentin. J Dent Res 81:119–122CrossRef Ceballos L, Osorio R, Toledano M, Tay F, Marshall GW (2002) Bonding to Er:YAG laser treated dentin. J Dent Res 81:119–122CrossRef
24.
go back to reference Schein MT, Bocangel JS, Nogueira GEC, Schein PAL (2003) SEM evaluation of interaction pattern dentin and resin after cavity preparation using Er:YAG laser. J Dent 31:127–135CrossRefPubMed Schein MT, Bocangel JS, Nogueira GEC, Schein PAL (2003) SEM evaluation of interaction pattern dentin and resin after cavity preparation using Er:YAG laser. J Dent 31:127–135CrossRefPubMed
25.
go back to reference Amaral FLB, Colucci V, Souza-Gabriel AE, Chinelatti MA, Palma-Dibb RG, Corona SAM (2008) Adhesion to Er:YAG laser-prepared dentin after long-term water storage and thermocycling. Oper Dent 33:51–58CrossRefPubMed Amaral FLB, Colucci V, Souza-Gabriel AE, Chinelatti MA, Palma-Dibb RG, Corona SAM (2008) Adhesion to Er:YAG laser-prepared dentin after long-term water storage and thermocycling. Oper Dent 33:51–58CrossRefPubMed
26.
go back to reference De Munck J, Van Landuyt K, Peumans M, Poitevin A, Lambrechts P, Braem M, Van Meerbeek B (2005) A critical review of the durability of adhesion to tooth tissue: methods and results. J Dent Res 84:118–132CrossRefPubMed De Munck J, Van Landuyt K, Peumans M, Poitevin A, Lambrechts P, Braem M, Van Meerbeek B (2005) A critical review of the durability of adhesion to tooth tissue: methods and results. J Dent Res 84:118–132CrossRefPubMed
27.
go back to reference Frankenberger R, Pashley DH, Reich SM, Lohbauer U, Petschelt A, Tay FR (2005) Characterization of resin-dentine interfaces by compressive cyclic loading. Biomaterials 26:2043–2052CrossRefPubMed Frankenberger R, Pashley DH, Reich SM, Lohbauer U, Petschelt A, Tay FR (2005) Characterization of resin-dentine interfaces by compressive cyclic loading. Biomaterials 26:2043–2052CrossRefPubMed
28.
go back to reference Hebling J, Pashley DH, Tjäderhane L, Tay FR (2005) Chlorhexidine arrests subclinical degradation of dentin hybrid layers in vivo. J Dent Res 84:741–746CrossRefPubMed Hebling J, Pashley DH, Tjäderhane L, Tay FR (2005) Chlorhexidine arrests subclinical degradation of dentin hybrid layers in vivo. J Dent Res 84:741–746CrossRefPubMed
29.
go back to reference Yiu CK, King NM, Pashley DH, Suh BI, Carvalho RM, Carrilho MR (2004) Effect of resin hydrophilicity and water storage on resin strength. Biomaterials 25:5789–5796CrossRefPubMed Yiu CK, King NM, Pashley DH, Suh BI, Carvalho RM, Carrilho MR (2004) Effect of resin hydrophilicity and water storage on resin strength. Biomaterials 25:5789–5796CrossRefPubMed
30.
go back to reference De Munck J, Van den Steen PE, Mine A, Van Landuyt KL, Poitevin A, Opdenakker G, Van Meerbeek B (2009) Inhibition of enzymatic degradation of adhesive-dentin interfaces. J Dent Res 88:1101–1106CrossRefPubMed De Munck J, Van den Steen PE, Mine A, Van Landuyt KL, Poitevin A, Opdenakker G, Van Meerbeek B (2009) Inhibition of enzymatic degradation of adhesive-dentin interfaces. J Dent Res 88:1101–1106CrossRefPubMed
31.
go back to reference Sulkala M, Larmas M, Sorsa T, Salo T, Tjäderhane L (2002) The localization of matrix metalloproteinase-20 (MMP-20, enamelysin) in mature human teeth. J Dent Res 81:603–607CrossRefPubMed Sulkala M, Larmas M, Sorsa T, Salo T, Tjäderhane L (2002) The localization of matrix metalloproteinase-20 (MMP-20, enamelysin) in mature human teeth. J Dent Res 81:603–607CrossRefPubMed
32.
go back to reference Tjärderhane L, Larjava H, Sorsa T, Uito VJ, Larmas M, Salo T (1998) The activation and function of host matrix metalloproteinases in dentin matrix breakdown in caries lesions. J Dent Res 77:1622–1629CrossRef Tjärderhane L, Larjava H, Sorsa T, Uito VJ, Larmas M, Salo T (1998) The activation and function of host matrix metalloproteinases in dentin matrix breakdown in caries lesions. J Dent Res 77:1622–1629CrossRef
33.
go back to reference Chaussain-Miller C, Fioretti F, Goldberg M, Menashi S (2006) The role of matrix metalloproteinases (MMPs) in human caries. J Dent Res 85:22–32CrossRefPubMed Chaussain-Miller C, Fioretti F, Goldberg M, Menashi S (2006) The role of matrix metalloproteinases (MMPs) in human caries. J Dent Res 85:22–32CrossRefPubMed
34.
go back to reference Mazzoni A, Pashley DH, Nishitani Y, Breschi L, Mannello F, Tjäderhane L, Toledano M, Pashley EL, Tay FR (2007) Reactivation of inactivated endogenous proteolytic activities in phosphoric acid-etched dentine by etch-and-rinse adhesives. Biomaterials 27:4470–4476CrossRef Mazzoni A, Pashley DH, Nishitani Y, Breschi L, Mannello F, Tjäderhane L, Toledano M, Pashley EL, Tay FR (2007) Reactivation of inactivated endogenous proteolytic activities in phosphoric acid-etched dentine by etch-and-rinse adhesives. Biomaterials 27:4470–4476CrossRef
35.
go back to reference Pashley DH, Tay FR, Yiu C, Hashimoto M, Breschi L, Carvalho RM, Ito S (2004) Collagen degradation by host-derived enzymes during aging. J Dent Res 83:216–221CrossRefPubMed Pashley DH, Tay FR, Yiu C, Hashimoto M, Breschi L, Carvalho RM, Ito S (2004) Collagen degradation by host-derived enzymes during aging. J Dent Res 83:216–221CrossRefPubMed
36.
go back to reference Geraldo-Martins VR, Robles FR, Matos AB (2007) Chlorhexidine’s effect on sealing ability of composite restorations following Er:YAG laser cavity preparation. J Contemp Dent Pract 8:26–33PubMed Geraldo-Martins VR, Robles FR, Matos AB (2007) Chlorhexidine’s effect on sealing ability of composite restorations following Er:YAG laser cavity preparation. J Contemp Dent Pract 8:26–33PubMed
37.
go back to reference Dalkilic EE, Omurlu H (2012) Two-year clinical evaluation of three adhesive systems in non-carious cervical lesions. J Appl Oral Sci 20:192–199CrossRef Dalkilic EE, Omurlu H (2012) Two-year clinical evaluation of three adhesive systems in non-carious cervical lesions. J Appl Oral Sci 20:192–199CrossRef
38.
go back to reference Pinto AS, de Araújo FB, Franzon R, Figueiredo MC, Henz S, García-Godoy F, Maltz M (2006) Clinical and microbiological effect of calcium hydroxide protection in indirect pulp capping in primary teeth. Am J Dent 19:382–386PubMed Pinto AS, de Araújo FB, Franzon R, Figueiredo MC, Henz S, García-Godoy F, Maltz M (2006) Clinical and microbiological effect of calcium hydroxide protection in indirect pulp capping in primary teeth. Am J Dent 19:382–386PubMed
39.
go back to reference Maltz M, Oliveira EF, Fontanella V, Carminatti G (2007) Deep caries lesions after incomplete dentine caries removal: 40-month follow-up study. Caries Res 4:493–496CrossRef Maltz M, Oliveira EF, Fontanella V, Carminatti G (2007) Deep caries lesions after incomplete dentine caries removal: 40-month follow-up study. Caries Res 4:493–496CrossRef
40.
go back to reference Clark J, Symons AL, Diklic S, Walsh LJ (2001) Effectiveness of diagnosing residual caries with various methods during cavity preparation using conventional methods, chemo-mechanical caries removal, and Er: YAG laser. Aust Dent J 46:S20 Clark J, Symons AL, Diklic S, Walsh LJ (2001) Effectiveness of diagnosing residual caries with various methods during cavity preparation using conventional methods, chemo-mechanical caries removal, and Er: YAG laser. Aust Dent J 46:S20
41.
go back to reference Bergenholtz G (2000) Evidence for bacterial causation of adverse pulpal responses in resin-based dental restorations. Crit Rev Oral Biol Med 11:467–480CrossRefPubMed Bergenholtz G (2000) Evidence for bacterial causation of adverse pulpal responses in resin-based dental restorations. Crit Rev Oral Biol Med 11:467–480CrossRefPubMed
42.
go back to reference Straffon LH, Pink TC (2000) Trauma to the primary and young permanent dentitions. J Mich Dent Assoc 82:40–45PubMed Straffon LH, Pink TC (2000) Trauma to the primary and young permanent dentitions. J Mich Dent Assoc 82:40–45PubMed
43.
go back to reference Eberhard J, Bode K, Hedderich J, Jepsen S (2008) Cavity size difference after caries removal by a fluorescence-controlled Er:YAG laser and by conventional bur treatment. Clin Oral Invest 12:311–318CrossRef Eberhard J, Bode K, Hedderich J, Jepsen S (2008) Cavity size difference after caries removal by a fluorescence-controlled Er:YAG laser and by conventional bur treatment. Clin Oral Invest 12:311–318CrossRef
44.
go back to reference De Moor RJ, Delme KI (2010) Laser-assisted cavity preparation and adhesion to erbium-lased tooth structure: part 2. present-day adhesion to erbium-lased tooth structure in permanent teeth. J Adhes Dent 12:91–102PubMed De Moor RJ, Delme KI (2010) Laser-assisted cavity preparation and adhesion to erbium-lased tooth structure: part 2. present-day adhesion to erbium-lased tooth structure in permanent teeth. J Adhes Dent 12:91–102PubMed
45.
go back to reference Hasani Tabatabaei M, Shirmohammadi S, Yasini E, Mirzaei M, Arami S, Kermanshah H, Ranjbar Omrani L, Alimi A, Chiniforush N, Nakhostin A, Abbasi M (2015) Comparison of dentin permeability after tooth cavity preparation with diamond bur and Er:YAG laser. J Dent (Tehran) 12:630–635 Hasani Tabatabaei M, Shirmohammadi S, Yasini E, Mirzaei M, Arami S, Kermanshah H, Ranjbar Omrani L, Alimi A, Chiniforush N, Nakhostin A, Abbasi M (2015) Comparison of dentin permeability after tooth cavity preparation with diamond bur and Er:YAG laser. J Dent (Tehran) 12:630–635
46.
go back to reference Aranha AC, De Paula EC, Gutknecht N, Marques MM, Ramalho KM, Apel C (2007) Analysis of the interfacial micromorphology of adhesive systems in cavities prepared with Er, Cr:YSG, Er:YAG laser and bur. Microsc Res Tech 70:745–751CrossRefPubMed Aranha AC, De Paula EC, Gutknecht N, Marques MM, Ramalho KM, Apel C (2007) Analysis of the interfacial micromorphology of adhesive systems in cavities prepared with Er, Cr:YSG, Er:YAG laser and bur. Microsc Res Tech 70:745–751CrossRefPubMed
47.
go back to reference Ramos TM, Ramos–Oliveira TM, Moretto SG, Freitas PM, Eduardo CP (2014) Microtensile bond strength analysis of adhesive systems to Er:YAG and Er, Cr:YSGG laser-treated dentin. Lasers Med Sci 29:565–573CrossRefPubMed Ramos TM, Ramos–Oliveira TM, Moretto SG, Freitas PM, Eduardo CP (2014) Microtensile bond strength analysis of adhesive systems to Er:YAG and Er, Cr:YSGG laser-treated dentin. Lasers Med Sci 29:565–573CrossRefPubMed
48.
go back to reference Carvalho AO, Reis AF, de Oliveira MT, de Freitas PC, Aranha AC, Eduardo Cde P, Giannini M (2011) Bond strength of adhesive systems to Er, Cr:YSGG laser-irradiated dentin. Photomed Laser Surg 29:747–752CrossRefPubMed Carvalho AO, Reis AF, de Oliveira MT, de Freitas PC, Aranha AC, Eduardo Cde P, Giannini M (2011) Bond strength of adhesive systems to Er, Cr:YSGG laser-irradiated dentin. Photomed Laser Surg 29:747–752CrossRefPubMed
49.
go back to reference Ozel E, Tuna EB, Firatli S, Firatli E (2016) Effect of different parameters of Er:YAG laser irradiations on class V composite restorations: a scanning electron microscopy study. Scanning. doi:10.1002/sca.21292 Ozel E, Tuna EB, Firatli S, Firatli E (2016) Effect of different parameters of Er:YAG laser irradiations on class V composite restorations: a scanning electron microscopy study. Scanning. doi:10.​1002/​sca.​21292
50.
go back to reference Valério RA, Borsatto MC, Serra MC, Polizeli SA, Nemezio MA, Galo R, Aires CP, Dos Santos AC, Corona SA (2015) Caries removal in deciduous teeth using an Er:YAG laser: a randomized split-mouth clinical trial. Clin Oral Invest 20:65–73CrossRef Valério RA, Borsatto MC, Serra MC, Polizeli SA, Nemezio MA, Galo R, Aires CP, Dos Santos AC, Corona SA (2015) Caries removal in deciduous teeth using an Er:YAG laser: a randomized split-mouth clinical trial. Clin Oral Invest 20:65–73CrossRef
51.
go back to reference Hamidi MM, Ercan E, Dülgergil ÇT, Çolak H (2015) Evaluation of the clinical success of class I cavities prepared by an Er:YAG laser-5-year follow-up study. Lasers Med Sci 30:1895–1901CrossRefPubMed Hamidi MM, Ercan E, Dülgergil ÇT, Çolak H (2015) Evaluation of the clinical success of class I cavities prepared by an Er:YAG laser-5-year follow-up study. Lasers Med Sci 30:1895–1901CrossRefPubMed
52.
go back to reference Cvar JF, Ryge G (2005) Reprint of criteria for the clinical evaluation of dental restorative materials. Clin Oral Invest 9:215–232CrossRef Cvar JF, Ryge G (2005) Reprint of criteria for the clinical evaluation of dental restorative materials. Clin Oral Invest 9:215–232CrossRef
53.
go back to reference Tay FR, Pashley DH, Loushine RJ, Weller RN, Monticelli F, Osorio R (2006) Self-etching adhesives increase collagenolytic activity in radicular dentin. J Endod 32:862–886CrossRefPubMed Tay FR, Pashley DH, Loushine RJ, Weller RN, Monticelli F, Osorio R (2006) Self-etching adhesives increase collagenolytic activity in radicular dentin. J Endod 32:862–886CrossRefPubMed
54.
go back to reference Nishitani Y, Yoshiyama M, Wadgaonkar B, Breschi L, Mannello F, Mazzoni A, Carvalho RM, Tjäderhane L, Tay FR, Pashley DH (2006) Activation of gelatinolytic/collagenolytic activity in dentin by self-etching adhesives. Eur J Oral Sci 14:160–166CrossRef Nishitani Y, Yoshiyama M, Wadgaonkar B, Breschi L, Mannello F, Mazzoni A, Carvalho RM, Tjäderhane L, Tay FR, Pashley DH (2006) Activation of gelatinolytic/collagenolytic activity in dentin by self-etching adhesives. Eur J Oral Sci 14:160–166CrossRef
Metadata
Title
Clinical evaluation of composite restorations in Er:YAG laser-prepared cavities re-wetting with chlorhexidine
Authors
Daniel Galafassi
Camila Scatena
Rodrigo Galo
Fabiana Almeida Curylofo-Zotti
Silmara Aparecida Milori Corona
Maria Cristina Borsatto
Publication date
01-05-2017
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 4/2017
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-016-1897-x

Other articles of this Issue 4/2017

Clinical Oral Investigations 4/2017 Go to the issue