Clinical retention force development of double crowns

Authors: Stefan Bayer, Helmut Stark, Lina Gölz, Ludger Keilig, Dominik Kraus, Anja Hansen, Norbert Enkling

Published in: Clinical Oral Investigations | Issue 2/2012

Login to get access

Abstract

This study deals with the development of the retentive forces of double crowns intraorally measured. Twenty-five combined fixed–removable prostheses with a total of 84 double crowns were included in the study. The intraoral measurement was performed at 72 defined measuring points directly adjacent to the double crowns of the dentures. The measurement was performed 4–6 weeks (baseline), 6 months (recall 1), and 18 months (recall 2) after the insertion of the restoration. A specifically designed measuring device was used. The median values for the single measuring points reached 4.705 N at the baseline, 5.190 N after 6 months, and 3.740 N after 18 months. The measured values were analyzed according to differences between the median retention forces at the three defined points in time. The statistical analysis of the median values showed no statistical difference for the retention force change after 6 months but for the decrease until the second recall (Mann–Whitney test). The retention force per denture was calculated by a summation of the single measuring points. At the baseline, 12.9 N was reached. The forces did only decrease slightly and were not statistically significant. The results indicate that retention force values of double crowns, measured intraorally at the patient, do not relevantly change clinically within the first 1.5 years. Within the limitations of this study, it can be stated that wear does not influence the retentive forces of double crowns within the first 18 months. After this period the retention force should be still sufficient for denture retention.
Literature
1.
go back to reference Becerra G, MacEntee M (1987) A classification of precision attachments. J Prosthet Dent 58:322–327PubMedCrossRef Becerra G, MacEntee M (1987) A classification of precision attachments. J Prosthet Dent 58:322–327PubMedCrossRef
2.
go back to reference Wolfe RE (1985) Symposium on semiprecision attachments in removable partial dentures. Extracoronal attachments. Dent Clin North Am 29:185–198PubMed Wolfe RE (1985) Symposium on semiprecision attachments in removable partial dentures. Extracoronal attachments. Dent Clin North Am 29:185–198PubMed
3.
go back to reference Bayer S, Steinheuser D, Gruner M, Keilig L, Enkling N, Stark H, Mues S (2009) Comparative study of four retentive anchor systems for implant supported overdentures—retention force changes. Gerodontology 26:268–272PubMedCrossRef Bayer S, Steinheuser D, Gruner M, Keilig L, Enkling N, Stark H, Mues S (2009) Comparative study of four retentive anchor systems for implant supported overdentures—retention force changes. Gerodontology 26:268–272PubMedCrossRef
4.
go back to reference Stancic I, Jelenkovic A (2008) Retention of telescopic denture in elderly patients with maximum partially edentulous arch. Gerodontology 25:162–167PubMedCrossRef Stancic I, Jelenkovic A (2008) Retention of telescopic denture in elderly patients with maximum partially edentulous arch. Gerodontology 25:162–167PubMedCrossRef
5.
go back to reference Wostmann B, Balkenhol M, Kothe A, Ferger P (2008) Dental impact on daily living of telescopic crown-retained partial dentures. Int J Prosthodont 21:419–421PubMed Wostmann B, Balkenhol M, Kothe A, Ferger P (2008) Dental impact on daily living of telescopic crown-retained partial dentures. Int J Prosthodont 21:419–421PubMed
6.
go back to reference Behr M, Hofmann E, Rosentritt M, Lang R, Handel G (2000) Technical failure rates of double crown-retained removable partial dentures. Clin Oral Investig 4:87–90PubMedCrossRef Behr M, Hofmann E, Rosentritt M, Lang R, Handel G (2000) Technical failure rates of double crown-retained removable partial dentures. Clin Oral Investig 4:87–90PubMedCrossRef
7.
go back to reference Wostmann B, Balkenhol M, Weber A, Ferger P, Rehmann P (2007) Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintenance. J Dent 35:939–945PubMedCrossRef Wostmann B, Balkenhol M, Weber A, Ferger P, Rehmann P (2007) Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintenance. J Dent 35:939–945PubMedCrossRef
8.
go back to reference Stark H, Schrenker H (1998) Telescopic crown retained dentures—a clinical long-term study. Dtsch Zahnärztl Z 3:183–186 Stark H, Schrenker H (1998) Telescopic crown retained dentures—a clinical long-term study. Dtsch Zahnärztl Z 3:183–186
9.
go back to reference Stark H (1996) Clinical and material studies of telescopic dentures—clinical long-term results and wear tests. Hänsel-Hohenhausen, Frankfurt Stark H (1996) Clinical and material studies of telescopic dentures—clinical long-term results and wear tests. Hänsel-Hohenhausen, Frankfurt
10.
go back to reference Igarashi Y, Goto T (1997) Ten-year follow-up study of conical crown-retained dentures. Int J Prosthodont 10(2):149–155PubMed Igarashi Y, Goto T (1997) Ten-year follow-up study of conical crown-retained dentures. Int J Prosthodont 10(2):149–155PubMed
11.
go back to reference Beschnidt SM, Chitmongkolsuk S, Prull R (2001) Telescopic crown-retained removable partial dentures: review and case report. Compend Contin Educ Dent 22(11):927–928PubMed Beschnidt SM, Chitmongkolsuk S, Prull R (2001) Telescopic crown-retained removable partial dentures: review and case report. Compend Contin Educ Dent 22(11):927–928PubMed
12.
go back to reference Bergman B, Ericson A, Molin M (1996) Long-term clinical results after treatment with conical crown-retained dentures. Int J Prosthodont 9(6):533–538PubMed Bergman B, Ericson A, Molin M (1996) Long-term clinical results after treatment with conical crown-retained dentures. Int J Prosthodont 9(6):533–538PubMed
13.
go back to reference Grossmann AC, Hassel AJ, Schilling O, Lehmann F, Koob A, Rammelsberg P (2007) Treatment with double crown-retained removable partial dentures and oral health-related quality of life in middle- and high-aged patients. Int J Prosthodont 20(6):576–578PubMed Grossmann AC, Hassel AJ, Schilling O, Lehmann F, Koob A, Rammelsberg P (2007) Treatment with double crown-retained removable partial dentures and oral health-related quality of life in middle- and high-aged patients. Int J Prosthodont 20(6):576–578PubMed
14.
go back to reference Mock F, Schrenker H, Stark HK (2005) Success of telescopic crowns—a prospective long term study. Dtsch Zahnärztl Z 3(60):148–153 Mock F, Schrenker H, Stark HK (2005) Success of telescopic crowns—a prospective long term study. Dtsch Zahnärztl Z 3(60):148–153
15.
go back to reference Hagner MWHR, Grüner M, Bayer S, Keilig L, Reimann S, Bourauel C, Utz KH, Stark H (2006) Wear analysis of telescopic crowns—an in vitro study. Dtsch Zahnärztl Z 11(61):594–603 Hagner MWHR, Grüner M, Bayer S, Keilig L, Reimann S, Bourauel C, Utz KH, Stark H (2006) Wear analysis of telescopic crowns—an in vitro study. Dtsch Zahnärztl Z 11(61):594–603
16.
go back to reference Becker H (1983) Retention mechanism of telescopic crowns. Zahnarztl Prax 34(7):281–284PubMed Becker H (1983) Retention mechanism of telescopic crowns. Zahnarztl Prax 34(7):281–284PubMed
17.
go back to reference Korber KH (1983) Conical crowns—a rational telescopic system. ZWR 92(2):38–43PubMed Korber KH (1983) Conical crowns—a rational telescopic system. ZWR 92(2):38–43PubMed
18.
go back to reference Botega DM, Mesquita MF, Henriques GE, Vaz LG (2004) Retention force and fatigue strength of overdenture attachment systems. J Oral Rehabil 31(9):884–889PubMedCrossRef Botega DM, Mesquita MF, Henriques GE, Vaz LG (2004) Retention force and fatigue strength of overdenture attachment systems. J Oral Rehabil 31(9):884–889PubMedCrossRef
19.
go back to reference Lehmann KM, Armin FV (1976) Study of retentive forces of ball anchors. Schweiz Monatsschr Zahnmed 86:521–530 Lehmann KM, Armin FV (1976) Study of retentive forces of ball anchors. Schweiz Monatsschr Zahnmed 86:521–530
20.
go back to reference Bayer S, Stark H, Mues S, Keilig L, Schrader A, Enkling N (2009) Retention force measurement of telescopic crowns. Clin Oral Investig 14(5):607–611PubMedCrossRef Bayer S, Stark H, Mues S, Keilig L, Schrader A, Enkling N (2009) Retention force measurement of telescopic crowns. Clin Oral Investig 14(5):607–611PubMedCrossRef
21.
go back to reference Naert I, Gizani S, Vuylsteke M, Van Steenberghe D (1999) A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: prosthetic aspects and patient satisfaction. J Oral Rehabil 26(3):195–202PubMedCrossRef Naert I, Gizani S, Vuylsteke M, Van Steenberghe D (1999) A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: prosthetic aspects and patient satisfaction. J Oral Rehabil 26(3):195–202PubMedCrossRef
22.
go back to reference van Kampen F, Cune M, van der Bilt A, Bosman F (2003) Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 14(6):720–726PubMedCrossRef van Kampen F, Cune M, van der Bilt A, Bosman F (2003) Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 14(6):720–726PubMedCrossRef
23.
go back to reference Burns DR, Unger JW, Elswick RK Jr, Beck DA (1995) Prospective clinical evaluation of mandibular implant overdentures: Part I—Retention, stability, and tissue response. J Prosthet Dent 73(4):354–363PubMedCrossRef Burns DR, Unger JW, Elswick RK Jr, Beck DA (1995) Prospective clinical evaluation of mandibular implant overdentures: Part I—Retention, stability, and tissue response. J Prosthet Dent 73(4):354–363PubMedCrossRef
24.
go back to reference Naert I, Quirynen M, Hooghe M, van Steenberghe D (1994) A comparative prospective study of splinted and unsplinted Branemark implants in mandibular overdenture therapy: a preliminary report. J Prosthet Dent 71(5):486–492PubMedCrossRef Naert I, Quirynen M, Hooghe M, van Steenberghe D (1994) A comparative prospective study of splinted and unsplinted Branemark implants in mandibular overdenture therapy: a preliminary report. J Prosthet Dent 71(5):486–492PubMedCrossRef
25.
go back to reference Stuttgen U (1983) Experimental study of the parallelism of milled telescoping primary anchors. Dtsch Zahnärztl Z 38(5):538–540PubMed Stuttgen U (1983) Experimental study of the parallelism of milled telescoping primary anchors. Dtsch Zahnärztl Z 38(5):538–540PubMed
26.
go back to reference Minagi S, Natsuaki N, Nishigawa G, Sato T (1999) New telescopic crown design for removable partial dentures. J Prosthet Dent 81(6):684–688PubMedCrossRef Minagi S, Natsuaki N, Nishigawa G, Sato T (1999) New telescopic crown design for removable partial dentures. J Prosthet Dent 81(6):684–688PubMedCrossRef
27.
go back to reference Gungor MA, Artunc C, Sonugelen M (2004) Parameters affecting retentive force of conus crowns. J Oral Rehabil 31(3):271–277PubMedCrossRef Gungor MA, Artunc C, Sonugelen M (2004) Parameters affecting retentive force of conus crowns. J Oral Rehabil 31(3):271–277PubMedCrossRef
28.
go back to reference Bohr M (2000) Clinical examination of a technique for retention force adjustment of telescopic crowns. Dissertation, University of Hamburg Bohr M (2000) Clinical examination of a technique for retention force adjustment of telescopic crowns. Dissertation, University of Hamburg
29.
go back to reference Holst S, Blatz MB, Eitner S, Wichmann M (2006) In vitro wear of different material combinations of intracoronal precision attachments. Int J Prosthodont 19(4):330–332PubMed Holst S, Blatz MB, Eitner S, Wichmann M (2006) In vitro wear of different material combinations of intracoronal precision attachments. Int J Prosthodont 19(4):330–332PubMed
30.
go back to reference Naert IE, Gizani S, Vuylsteke M, van Steenberghe D (1997) A randomised clinical trial on the influence of splinted and unsplinted oral implants in mandibular overdenture therapy. A 3-year report. Clin Oral Investig 1(2):81–88PubMedCrossRef Naert IE, Gizani S, Vuylsteke M, van Steenberghe D (1997) A randomised clinical trial on the influence of splinted and unsplinted oral implants in mandibular overdenture therapy. A 3-year report. Clin Oral Investig 1(2):81–88PubMedCrossRef
Metadata
Title
Clinical retention force development of double crowns
Authors
Stefan Bayer
Helmut Stark
Lina Gölz
Ludger Keilig
Dominik Kraus
Anja Hansen
Norbert Enkling
Publication date
01-04-2012
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 2/2012
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-011-0530-2

Other articles of this Issue 2/2012

Clinical Oral Investigations 2/2012 Go to the issue