Skip to main content
Top
Published in: Clinical Oral Investigations 3/2009

01-09-2009 | Original Article

Precision of fit: zirconia three-unit fixed dental prostheses

Authors: Florian Beuer, Michael Naumann, Wolfgang Gernet, John A. Sorensen

Published in: Clinical Oral Investigations | Issue 3/2009

Login to get access

Abstract

The purpose of this in vitro study was to compare the precision of fit of substructures milled from semi-sintered zirconia blocks fabricated with two different computer-assisted design (CAD)/computer-assisted manufacturing (CAM) systems. Three-unit posterior fixed dental prostheses (FDP) were fabricated for standardized dies (n = 10) with the Lava CAD/CAM system (Lava) and the Procera-bridge-zirconia CAD/CAM system (Procera). After cementation to the dies, the FDP were embedded and sectioned. Four cross-sections were made of each abutment tooth, and marginal and internal fit were evaluated under an optical microscope. A one-way analysis of variance was used to compare data (α = 0.05). Mean gap dimensions at the marginal opening for Lava and Procera were 15 (±7) μm and 9 (±5) μm, respectively. Mean marginal openings (P = 0.012) and internal adaptation at two out of three measurement locations were significantly different. Within the limitations of this study, the results suggest that the accuracy of both investigated systems is satisfactory for clinical use.
Literature
1.
go back to reference Andersson B, Taylor A, Lang BR, Scheller H, Scharer P, Sorensen JA et al (2001) Alumina ceramic implant abutments used for single-tooth replacement: a prospective 1- to 3-year multicenter study. Int J Prosthodont 14:432–438PubMed Andersson B, Taylor A, Lang BR, Scheller H, Scharer P, Sorensen JA et al (2001) Alumina ceramic implant abutments used for single-tooth replacement: a prospective 1- to 3-year multicenter study. Int J Prosthodont 14:432–438PubMed
2.
go back to reference Belser UC, MacEntee MI, Richter WA (1985) Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study. J Prosthet Dent 53:24–29PubMedCrossRef Belser UC, MacEntee MI, Richter WA (1985) Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study. J Prosthet Dent 53:24–29PubMedCrossRef
4.
go back to reference Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204:505–511PubMedCrossRef Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204:505–511PubMedCrossRef
5.
go back to reference Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2008) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations. Dent Mater. doi:10.1016/j.dental.2008.04.019 Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2008) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations. Dent Mater. doi:10.​1016/​j.​dental.​2008.​04.​019
6.
go back to reference Bindl A, Mormann WH (2004) Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2–5 years. Eur J Oral Sci 112:197–204PubMedCrossRef Bindl A, Mormann WH (2004) Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2–5 years. Eur J Oral Sci 112:197–204PubMedCrossRef
7.
go back to reference Bindl A, Mormann WH (2005) Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil 32:441–447PubMedCrossRef Bindl A, Mormann WH (2005) Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil 32:441–447PubMedCrossRef
8.
go back to reference Bindl A, Mormann WH (2007) Fit of all-ceramic posterior fixed partial denture frameworks in vitro. Int J Periodontics Restorative Dent 27:567–575PubMed Bindl A, Mormann WH (2007) Fit of all-ceramic posterior fixed partial denture frameworks in vitro. Int J Periodontics Restorative Dent 27:567–575PubMed
9.
go back to reference Coli P, Karlsson S (2004) Precision of a CAD/CAM technique for the production of zirconium dioxide copings. Int J Prosthodont 17:577–580PubMed Coli P, Karlsson S (2004) Precision of a CAD/CAM technique for the production of zirconium dioxide copings. Int J Prosthodont 17:577–580PubMed
10.
go back to reference Devaud V (2005) Guidelines for success with zirconia ceramics: the changing standards. Pract Proced Aesthet Dent 17:508 510PubMed Devaud V (2005) Guidelines for success with zirconia ceramics: the changing standards. Pract Proced Aesthet Dent 17:508 510PubMed
11.
go back to reference Edelhoff D, Sorensen JA (2002) Retention of selected core materials to zirconia posts. Oper Dent 27:455–461PubMed Edelhoff D, Sorensen JA (2002) Retention of selected core materials to zirconia posts. Oper Dent 27:455–461PubMed
12.
go back to reference Federlin M, Manner T, Hiller KA, Schmidt S, Schmalz G (2006) Two-year clinical performance of cast gold vs ceramic partial crowns. Clin Oral Investig 10:126–133PubMedCrossRef Federlin M, Manner T, Hiller KA, Schmidt S, Schmalz G (2006) Two-year clinical performance of cast gold vs ceramic partial crowns. Clin Oral Investig 10:126–133PubMedCrossRef
13.
go back to reference Federlin M, Wagner J, Manner T, Hiller KA, Schmalz G (2007) Three-year clinical performance of cast gold vs ceramic partial crowns. Clin Oral Investig 11:345–352PubMedCrossRef Federlin M, Wagner J, Manner T, Hiller KA, Schmalz G (2007) Three-year clinical performance of cast gold vs ceramic partial crowns. Clin Oral Investig 11:345–352PubMedCrossRef
14.
go back to reference Ferracane JL, Matsumoto H, Okabe T (1985) Time-dependent deformation of composite resins—compositional considerations. J Dent Res 64:1332–1336PubMed Ferracane JL, Matsumoto H, Okabe T (1985) Time-dependent deformation of composite resins—compositional considerations. J Dent Res 64:1332–1336PubMed
15.
go back to reference Fleming GJ, Dobinson MM, Landini G, Harris JJ (2005) An in-vitro investigation of the accuracy of fit of Procera and Empress crowns. Eur J Prosthodont Restor Dent 13:109–114PubMed Fleming GJ, Dobinson MM, Landini G, Harris JJ (2005) An in-vitro investigation of the accuracy of fit of Procera and Empress crowns. Eur J Prosthodont Restor Dent 13:109–114PubMed
16.
go back to reference Grey NJ, Piddock V, Wilson MA (1993) In vitro comparison of conventional crowns and a new all-ceramic system. J Dent 21:47–51PubMedCrossRef Grey NJ, Piddock V, Wilson MA (1993) In vitro comparison of conventional crowns and a new all-ceramic system. J Dent 21:47–51PubMedCrossRef
17.
go back to reference Hirano S, Hirasawa T (1994) Compressive creep of posterior and anterior composite resins in water. Dent Mater J 13:214–219PubMed Hirano S, Hirasawa T (1994) Compressive creep of posterior and anterior composite resins in water. Dent Mater J 13:214–219PubMed
18.
go back to reference Holmes JR, Bayne SC, Holland GA, Sulik WD (1989) Considerations in measurement of marginal fit. J Prosthet Dent 62:405–408PubMedCrossRef Holmes JR, Bayne SC, Holland GA, Sulik WD (1989) Considerations in measurement of marginal fit. J Prosthet Dent 62:405–408PubMedCrossRef
19.
go back to reference Hung SH, Hung KS, Eick JD, Chappell RP (1990) Marginal fit of porcelain-fused-to-metal and two types of ceramic crown. J Prosthet Dent 63:26–31PubMedCrossRef Hung SH, Hung KS, Eick JD, Chappell RP (1990) Marginal fit of porcelain-fused-to-metal and two types of ceramic crown. J Prosthet Dent 63:26–31PubMedCrossRef
20.
go back to reference Karlsson S (1993) The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 51:129–134PubMedCrossRef Karlsson S (1993) The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 51:129–134PubMedCrossRef
21.
go back to reference Kokubo Y, Ohkubo C, Tsumita M, Miyashita A, Vult von Steyern P, Fukushima S (2005) Clinical marginal and internal gaps of Procera AllCeram crowns. J Oral Rehabil 32:526–530PubMedCrossRef Kokubo Y, Ohkubo C, Tsumita M, Miyashita A, Vult von Steyern P, Fukushima S (2005) Clinical marginal and internal gaps of Procera AllCeram crowns. J Oral Rehabil 32:526–530PubMedCrossRef
22.
go back to reference May KB, Russell MM, Razzoog ME, Lang BR (1998) Precision of fit: the Procera AllCeram crown. J Prosthet Dent 80:394–404PubMedCrossRef May KB, Russell MM, Razzoog ME, Lang BR (1998) Precision of fit: the Procera AllCeram crown. J Prosthet Dent 80:394–404PubMedCrossRef
23.
go back to reference McLean JW, von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131:107–111PubMedCrossRef McLean JW, von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131:107–111PubMedCrossRef
24.
go back to reference Molin MK, Karlsson SL (2008) Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 21:223–227PubMed Molin MK, Karlsson SL (2008) Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 21:223–227PubMed
25.
go back to reference Ozcan M, Kerkdijk S, Valandro LF (2007) Comparison of resin cement adhesion to Y-TZP ceramic following manufacturers’ instructions of the cements only. Clin Oral Investig 26:26 Ozcan M, Kerkdijk S, Valandro LF (2007) Comparison of resin cement adhesion to Y-TZP ceramic following manufacturers’ instructions of the cements only. Clin Oral Investig 26:26
26.
27.
go back to reference Proussaefs P (2004) Crowns cemented on crown preparations lacking geometric resistance form. Part II: effect of cement. J Prosthodont 13:36–41PubMedCrossRef Proussaefs P (2004) Crowns cemented on crown preparations lacking geometric resistance form. Part II: effect of cement. J Prosthodont 13:36–41PubMedCrossRef
28.
go back to reference Raigrodski AJ, Chiche GJ (2002) All-ceramic fixed partial dentures, Part I: in vitro studies. J Esthet Restor Dent 14:188–191PubMedCrossRef Raigrodski AJ, Chiche GJ (2002) All-ceramic fixed partial dentures, Part I: in vitro studies. J Esthet Restor Dent 14:188–191PubMedCrossRef
29.
go back to reference Raigrodski AJ, Chiche GJ, Swift EJ Jr (2002) All-ceramic fixed partial dentures, Part III: clinical studies. J Esthet Restor Dent 14:313–319PubMedCrossRef Raigrodski AJ, Chiche GJ, Swift EJ Jr (2002) All-ceramic fixed partial dentures, Part III: clinical studies. J Esthet Restor Dent 14:313–319PubMedCrossRef
30.
go back to reference Reich S, Wichmann M, Nkenke E, Proeschel P (2005) Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 113:174–179PubMedCrossRef Reich S, Wichmann M, Nkenke E, Proeschel P (2005) Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 113:174–179PubMedCrossRef
31.
go back to reference Rekow D, Thompson VP (2005) Near-surface damage—a persistent problem in crowns obtained by computer-aided design and manufacturing. Proc Inst Mech Eng [H] 219:233–243 Rekow D, Thompson VP (2005) Near-surface damage—a persistent problem in crowns obtained by computer-aided design and manufacturing. Proc Inst Mech Eng [H] 219:233–243
32.
go back to reference Rekow ED, Harsono M, Janal M, Thompson VP, Zhang G (2006) Factorial analysis of variables influencing stress in all-ceramic crowns. Dent Mater 22:125–132PubMedCrossRef Rekow ED, Harsono M, Janal M, Thompson VP, Zhang G (2006) Factorial analysis of variables influencing stress in all-ceramic crowns. Dent Mater 22:125–132PubMedCrossRef
33.
go back to reference Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed
34.
go back to reference Schaerer P, Sato T, Wohlwend A (1988) A comparison of the marginal fit of three cast ceramic crown systems. J Prosthet Dent 59:534–542PubMedCrossRef Schaerer P, Sato T, Wohlwend A (1988) A comparison of the marginal fit of three cast ceramic crown systems. J Prosthet Dent 59:534–542PubMedCrossRef
35.
go back to reference Sorensen JA, Choi C, Fanuscu MI, Mito WT (1998) IPS Empress crown system: three-year clinical trial results. J Calif Dent Assoc 26:130–136PubMed Sorensen JA, Choi C, Fanuscu MI, Mito WT (1998) IPS Empress crown system: three-year clinical trial results. J Calif Dent Assoc 26:130–136PubMed
36.
go back to reference Sorensen JA, Okamoto SK, Seghi RR, Yarovesky U (1992) Marginal fidelity of four methods of swaged metal matrix crown fabrication. J Prosthet Dent 67:162–173PubMedCrossRef Sorensen JA, Okamoto SK, Seghi RR, Yarovesky U (1992) Marginal fidelity of four methods of swaged metal matrix crown fabrication. J Prosthet Dent 67:162–173PubMedCrossRef
37.
go back to reference Sulaiman F, Chai J, Jameson LM, Wozniak WT (1997) A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns. Int J Prosthodont 10:478–484PubMed Sulaiman F, Chai J, Jameson LM, Wozniak WT (1997) A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns. Int J Prosthodont 10:478–484PubMed
38.
go back to reference Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H (2001) Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont 14:231–238PubMed Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H (2001) Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont 14:231–238PubMed
39.
go back to reference Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ (2001) Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 26:367–374PubMed Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ (2001) Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 26:367–374PubMed
40.
go back to reference Tinschert J, Natt G, Mohrbotter N, Spiekermann H, Schulze KA (2007) Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations. J Biomed Mater Res B Appl Biomater 80:317–321PubMed Tinschert J, Natt G, Mohrbotter N, Spiekermann H, Schulze KA (2007) Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations. J Biomed Mater Res B Appl Biomater 80:317–321PubMed
41.
go back to reference Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H (2008) Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 21:217–222PubMed Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H (2008) Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 21:217–222PubMed
42.
go back to reference Tuntiprawon M, Wilson PR (1995) The effect of cement thickness on the fracture strength of all-ceramic crowns. Aust Dent J 40:17–21PubMedCrossRef Tuntiprawon M, Wilson PR (1995) The effect of cement thickness on the fracture strength of all-ceramic crowns. Aust Dent J 40:17–21PubMedCrossRef
43.
go back to reference Vaidyanathan J, Vaidyanathan TK (2001) Flexural creep deformation and recovery in dental composites. J Dent 29:545–551PubMedCrossRef Vaidyanathan J, Vaidyanathan TK (2001) Flexural creep deformation and recovery in dental composites. J Dent 29:545–551PubMedCrossRef
44.
go back to reference Vult von Steyern P, Carlson P, Nilner K (2005) All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 32:180–187PubMedCrossRef Vult von Steyern P, Carlson P, Nilner K (2005) All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 32:180–187PubMedCrossRef
45.
go back to reference Weaver JD, Johnson GH, Bales DJ (1991) Marginal adaptation of castable ceramic crowns. J Prosthet Dent 66:747–753PubMedCrossRef Weaver JD, Johnson GH, Bales DJ (1991) Marginal adaptation of castable ceramic crowns. J Prosthet Dent 66:747–753PubMedCrossRef
46.
go back to reference Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:320–336PubMedCrossRef Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:320–336PubMedCrossRef
Metadata
Title
Precision of fit: zirconia three-unit fixed dental prostheses
Authors
Florian Beuer
Michael Naumann
Wolfgang Gernet
John A. Sorensen
Publication date
01-09-2009
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 3/2009
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-008-0224-6

Other articles of this Issue 3/2009

Clinical Oral Investigations 3/2009 Go to the issue