Skip to main content
Top
Published in: Journal of Orthopaedic Science 1/2015

01-01-2015 | Original Article

Use of a tourniquet in total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials

Authors: Fang-zhen Jiang, Hui-ming Zhong, Yu-cai Hong, Guang-feng Zhao

Published in: Journal of Orthopaedic Science | Issue 1/2015

Login to get access

Abstract

Background

A tourniquet is commonly used in total knee arthroplasty (TKA). However, the effectiveness and safety of tourniquets are debated. We performed this study to investigate whether patients benefit from the use of tourniquets in TKA.

Methods

The literature search was conducted using PubMed, Cochrane Library, MEDLINE, Embase, and other medical databases. After a literature search, 26 randomized controlled trials involving 1,450 knees were analyzed.

Results

Tourniquet use significantly decreased intraoperative blood loss, transfusion rate, and operation time but not postoperative blood loss, measurable total blood loss, calculated total blood loss, transfusion volume, incidence of pulmonary embolism, or duration of hospital stay. It also slowed down joint functional recovery in the short term and increased the incidence of deep vein thrombosis and other minor wound complications.

Conclusions

Data from this meta-analysis indicate that patients may benefit from the use of a tourniquet in TKA; however, it use is accompanied by disadvantages and complications. Because of the very low-evidence quality and lower grading of recommendations, assessment, development, and evaluation recommendation strength, no guidelines can be developed based on current evidence.
Literature
1.
go back to reference Tai TW, Chang CW, Lai KA, Lin CJ, Yang CY. Effects of tourniquet use on blood loss and soft-tissue damage in total knee arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2012;94:2209–15.PubMedCrossRef Tai TW, Chang CW, Lai KA, Lin CJ, Yang CY. Effects of tourniquet use on blood loss and soft-tissue damage in total knee arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2012;94:2209–15.PubMedCrossRef
2.
go back to reference Smith TO, Hing CB. Is a tourniquet beneficial in total knee replacement surgery? A meta-analysis and systematic review. Knee. 2010;17:141–7. Smith TO, Hing CB. Is a tourniquet beneficial in total knee replacement surgery? A meta-analysis and systematic review. Knee. 2010;17:141–7.
3.
go back to reference Abdel-Salam A, Eyres KS. Effects of tourniquet during total knee arthroplasty. A prospective randomised study. J Bone Joint Surg Br. 1995;77:250–3.PubMed Abdel-Salam A, Eyres KS. Effects of tourniquet during total knee arthroplasty. A prospective randomised study. J Bone Joint Surg Br. 1995;77:250–3.PubMed
4.
go back to reference Clarke MT, Longstaff L, Edwards D, Rushton N. Tourniquet-induced wound hypoxia after total knee replacement. J Bone Joint Surg Br. 2001;83:40–4.PubMedCrossRef Clarke MT, Longstaff L, Edwards D, Rushton N. Tourniquet-induced wound hypoxia after total knee replacement. J Bone Joint Surg Br. 2001;83:40–4.PubMedCrossRef
5.
go back to reference Wauke K, Nagashima M, Kato N, Ogawa R, Yoshino S. Comparative study between thromboembolism and total knee arthroplasty with or without tourniquet in rheumatoid arthritis patients. Arch Orthop Traum Su. 2002;122:442–6. Wauke K, Nagashima M, Kato N, Ogawa R, Yoshino S. Comparative study between thromboembolism and total knee arthroplasty with or without tourniquet in rheumatoid arthritis patients. Arch Orthop Traum Su. 2002;122:442–6.
6.
go back to reference Kato N, Nakanishi K, Yoshino S, Ogawa R. Abnormal echogenic findings detected by transesophageal echocardiography and cardiorespiratory impairment during total knee arthroplasty with tourniquet. Anesthesiology. 2002;97:1123–8.PubMedCrossRef Kato N, Nakanishi K, Yoshino S, Ogawa R. Abnormal echogenic findings detected by transesophageal echocardiography and cardiorespiratory impairment during total knee arthroplasty with tourniquet. Anesthesiology. 2002;97:1123–8.PubMedCrossRef
7.
go back to reference Zhou XD, Li J, Xiong Y, Jiang LF, Li WJ, Wu LD. Do we really need closed-suction drainage in total hip arthroplasty? A meta-analysis. Int Orthop. 2013;37:2109–18.CrossRef Zhou XD, Li J, Xiong Y, Jiang LF, Li WJ, Wu LD. Do we really need closed-suction drainage in total hip arthroplasty? A meta-analysis. Int Orthop. 2013;37:2109–18.CrossRef
8.
go back to reference Harvey EJ, Leclerc J, Brooks CE, Burke DL. Effect of tourniquet use on blood loss and incidence of deep vein thrombosis in total knee arthroplasty. J Arthroplasty. 1997;12:291–6.PubMedCrossRef Harvey EJ, Leclerc J, Brooks CE, Burke DL. Effect of tourniquet use on blood loss and incidence of deep vein thrombosis in total knee arthroplasty. J Arthroplasty. 1997;12:291–6.PubMedCrossRef
9.
go back to reference Wakankar HM, Nicholl JE, Koka R, D’Arcy JC. The tourniquet in total knee arthroplasty. A prospective, randomised study. J Bone Joint Surg Br. 1999;81:30–3.PubMedCrossRef Wakankar HM, Nicholl JE, Koka R, D’Arcy JC. The tourniquet in total knee arthroplasty. A prospective, randomised study. J Bone Joint Surg Br. 1999;81:30–3.PubMedCrossRef
10.
go back to reference Aglietti P, Baldini A, Vena LM, Abbate R, Fedi S, Falciani M. Effect of tourniquet use on activation of coagulation in total knee replacement. Clin Orthop Relat Res. 2000;371:169–77.PubMedCrossRef Aglietti P, Baldini A, Vena LM, Abbate R, Fedi S, Falciani M. Effect of tourniquet use on activation of coagulation in total knee replacement. Clin Orthop Relat Res. 2000;371:169–77.PubMedCrossRef
11.
go back to reference Tetro AM, Rudan JF. The effects of a pneumatic tourniquet on blood loss in total knee arthroplasty. Can J Surg. 2001;44:33–8.PubMedCentralPubMed Tetro AM, Rudan JF. The effects of a pneumatic tourniquet on blood loss in total knee arthroplasty. Can J Surg. 2001;44:33–8.PubMedCentralPubMed
12.
go back to reference Vandenbussche E, Duranthon LD, Couturier M, Pidhorz L, Augereau B. The effect of tourniquet use in total knee arthroplasty. Int Orthop. 2002;26:306–9.PubMedCentralPubMedCrossRef Vandenbussche E, Duranthon LD, Couturier M, Pidhorz L, Augereau B. The effect of tourniquet use in total knee arthroplasty. Int Orthop. 2002;26:306–9.PubMedCentralPubMedCrossRef
13.
go back to reference Katsumata S, Nagashima M, Kato K, Tachihara A, Wauke K, Saito S, Jin E, Kawanami O, Ogawa R, Yoshino S. Changes in coagulation-fibrinolysis marker and neutrophil elastase following the use of tourniquet during total knee arthroplasty and the influence of neutrophil elastase on thromboembolism. Acta Anaesthesiol Scand. 2005;49:510–6.PubMedCrossRef Katsumata S, Nagashima M, Kato K, Tachihara A, Wauke K, Saito S, Jin E, Kawanami O, Ogawa R, Yoshino S. Changes in coagulation-fibrinolysis marker and neutrophil elastase following the use of tourniquet during total knee arthroplasty and the influence of neutrophil elastase on thromboembolism. Acta Anaesthesiol Scand. 2005;49:510–6.PubMedCrossRef
14.
go back to reference Matziolis G, Drahn T, Schroder JH, Krocker D, Tuischer J, Perka C. Endothelin-1 is secreted after total knee arthroplasty regardless of the use of a tourniquet. J Orthop Res. 2005;23:392–6.PubMedCrossRef Matziolis G, Drahn T, Schroder JH, Krocker D, Tuischer J, Perka C. Endothelin-1 is secreted after total knee arthroplasty regardless of the use of a tourniquet. J Orthop Res. 2005;23:392–6.PubMedCrossRef
15.
go back to reference Nishiguchi M, Takamura N, Abe Y, Kono M, Shindo H, Aoyagi K. Pilot study on the use of tourniquet: a risk factor for pulmonary thromboembolism after total knee arthroplasty? Thromb Res. 2005;115:271–6.PubMedCrossRef Nishiguchi M, Takamura N, Abe Y, Kono M, Shindo H, Aoyagi K. Pilot study on the use of tourniquet: a risk factor for pulmonary thromboembolism after total knee arthroplasty? Thromb Res. 2005;115:271–6.PubMedCrossRef
16.
go back to reference Fukuda A, Hasegawa M, Kato K, Shi D, Sudo A, Uchida A. Effect of tourniquet application on deep vein thrombosis after total knee arthroplasty. Arch Orthop Trauma Surg. 2007;127:671–5.PubMedCrossRef Fukuda A, Hasegawa M, Kato K, Shi D, Sudo A, Uchida A. Effect of tourniquet application on deep vein thrombosis after total knee arthroplasty. Arch Orthop Trauma Surg. 2007;127:671–5.PubMedCrossRef
17.
go back to reference Kageyama K, Nakajima Y, Shibasaki M, Hashimoto S, Mizobe T. Increased platelet, leukocyte, and endothelial cell activity are associated with increased coagulability in patients after total knee arthroplasty. J Thromb Haemost. 2007;5:738–45.PubMedCrossRef Kageyama K, Nakajima Y, Shibasaki M, Hashimoto S, Mizobe T. Increased platelet, leukocyte, and endothelial cell activity are associated with increased coagulability in patients after total knee arthroplasty. J Thromb Haemost. 2007;5:738–45.PubMedCrossRef
18.
go back to reference Li B, Qian QR, Wu HS, Zhao H, Lin XB, Zhu J, Weng WF. The use of a pneumatic tourniquet in total knee arthroplasty: a prospective, randomized study. Zhonghua wai ke za zhi (Chin J Surg). 2008;46:1054–7. Li B, Qian QR, Wu HS, Zhao H, Lin XB, Zhu J, Weng WF. The use of a pneumatic tourniquet in total knee arthroplasty: a prospective, randomized study. Zhonghua wai ke za zhi (Chin J Surg). 2008;46:1054–7.
19.
go back to reference Burg A, Dudkiewicz I, Heller S, Salai M, Velkes S. The effects of using a tourniquet in total knee arthroplasty: a study of 77 patients. J Musculoskelet Res. 2009;12:137–42.CrossRef Burg A, Dudkiewicz I, Heller S, Salai M, Velkes S. The effects of using a tourniquet in total knee arthroplasty: a study of 77 patients. J Musculoskelet Res. 2009;12:137–42.CrossRef
20.
21.
go back to reference Zhang Y, Qian QR, Wu HS, Liu HB, Li XH, Wu YL, Zhu YL. Effect of tourniquet on deep venous thrombosis after total knee arthroplasty. Zhong Hua Gu Ke Za Zhi. 2009;29:910–4. Zhang Y, Qian QR, Wu HS, Liu HB, Li XH, Wu YL, Zhu YL. Effect of tourniquet on deep venous thrombosis after total knee arthroplasty. Zhong Hua Gu Ke Za Zhi. 2009;29:910–4.
22.
go back to reference Shen ZW, Tong PJ, Shao YG, Pan T. Clinical effects of applying a tourniquet in total knee arthroplasty on swelling and function. Zhejiang Clin Med J. 2010;3:261–2. Shen ZW, Tong PJ, Shao YG, Pan T. Clinical effects of applying a tourniquet in total knee arthroplasty on swelling and function. Zhejiang Clin Med J. 2010;3:261–2.
23.
go back to reference Yavarikia A, Amjad GG, Davoudpour K. The influence of tourniquet use and timing of its release on blood loss in total knee arthroplasty. Pak J Biol Sci. 2010;13:249–52.PubMedCrossRef Yavarikia A, Amjad GG, Davoudpour K. The influence of tourniquet use and timing of its release on blood loss in total knee arthroplasty. Pak J Biol Sci. 2010;13:249–52.PubMedCrossRef
24.
go back to reference Zhang FJ, Xiao Y, Liu YB, Tian X, Gao ZG. Clinical effects of applying a tourniquet in total knee arthroplasty on blood loss. Chin Med J-Peking. 2010;123:3030–3. Zhang FJ, Xiao Y, Liu YB, Tian X, Gao ZG. Clinical effects of applying a tourniquet in total knee arthroplasty on blood loss. Chin Med J-Peking. 2010;123:3030–3.
25.
go back to reference Bao HX, Wang JF, Chu XB, LV C, Tong PJ. Tourniquet ischemia reperfusion injury after total knee arthroplasty in clinical research. Zhong Hua Chuang Shang Gu Ke Za Zhi (Chin J Orthop Trauma). 2011;13:242–6. Bao HX, Wang JF, Chu XB, LV C, Tong PJ. Tourniquet ischemia reperfusion injury after total knee arthroplasty in clinical research. Zhong Hua Chuang Shang Gu Ke Za Zhi (Chin J Orthop Trauma). 2011;13:242–6.
26.
go back to reference Lou W, Chen JP. Effect of pneumatic tourniquet on venous nitricoxide and endothelin levels in wounded of limb of patients undergoing total knee arthroplasty. Shanghai Med J. 2011;34:286–8. Lou W, Chen JP. Effect of pneumatic tourniquet on venous nitricoxide and endothelin levels in wounded of limb of patients undergoing total knee arthroplasty. Shanghai Med J. 2011;34:286–8.
27.
go back to reference Zhou W, Liu DH, Ma GT, Gong YK, Liu JS. Relationship between pneumatic tourniquet application in total knee arthroplasty and hypercoagulability. J Clin Rehabil Tissue Eng Res. 2011;15:1541–4. Zhou W, Liu DH, Ma GT, Gong YK, Liu JS. Relationship between pneumatic tourniquet application in total knee arthroplasty and hypercoagulability. J Clin Rehabil Tissue Eng Res. 2011;15:1541–4.
28.
go back to reference Ledin H, Aspenberg P, Good L. Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion. Acta Orthopaedica. 2012;83:499–503.PubMedCentralPubMedCrossRef Ledin H, Aspenberg P, Good L. Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion. Acta Orthopaedica. 2012;83:499–503.PubMedCentralPubMedCrossRef
29.
go back to reference Alcelik I, Pollock RD, Sukeik M, Bettany-Saltikov J, Armstrong PM, Fismer P. A comparison of outcomes with and without a tourniquet in total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. J Arthroplasty. 2012;27:331–40.PubMedCrossRef Alcelik I, Pollock RD, Sukeik M, Bettany-Saltikov J, Armstrong PM, Fismer P. A comparison of outcomes with and without a tourniquet in total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. J Arthroplasty. 2012;27:331–40.PubMedCrossRef
30.
go back to reference Tai TW, Lin CJ, Jou IM, Chang CW, Lai KA, Yang CY. Tourniquet use in total knee arthroplasty: a meta-analysis. Knee Surg Sport Tr A. 2011;19:1121–30.CrossRef Tai TW, Lin CJ, Jou IM, Chang CW, Lai KA, Yang CY. Tourniquet use in total knee arthroplasty: a meta-analysis. Knee Surg Sport Tr A. 2011;19:1121–30.CrossRef
Metadata
Title
Use of a tourniquet in total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials
Authors
Fang-zhen Jiang
Hui-ming Zhong
Yu-cai Hong
Guang-feng Zhao
Publication date
01-01-2015
Publisher
Springer Japan
Published in
Journal of Orthopaedic Science / Issue 1/2015
Print ISSN: 0949-2658
Electronic ISSN: 1436-2023
DOI
https://doi.org/10.1007/s00776-014-0664-6

Other articles of this Issue 1/2015

Journal of Orthopaedic Science 1/2015 Go to the issue