Skip to main content
Top
Published in: Journal of Orthopaedic Science 2/2009

Open Access 01-03-2009 | Instructional Lecture

Cementless total hip replacement: past, present, and future

Authors: Harumoto Yamada, Yasuo Yoshihara, Osamu Henmi, Mitsuhiro Morita, Yuichiro Shiromoto, Tomoki Kawano, Arihiko Kanaji, Kennichi Ando, Masato Nakagawa, Naoto Kosaki, Eiichi Fukaya

Published in: Journal of Orthopaedic Science | Issue 2/2009

Login to get access

Abstract

Cementless total hip replacement (THR) is rapidly being accepted as the surgery for arthritic diseases of the hip joint. The bone-ingrowth rate in porous-type cementless implants was about 90% over 10 years after surgery, showing that biological fixation of cementless THR was well maintained on both the stem and cup sides. As for the stress shielding of the femur operated using a distal fixation-type stem, severe bone resorption was observed. The severe bone resorption group showed continuous progression for more than 10 years after surgery. Stem loosening directly caused by stress shielding has been considered less likely; however, close attention should be paid to bone resorption-associated disorders including femoral fracture. Cementless cups have several specific problems. It is difficult to decide whether a cup should be placed in the physiological position for the case of acetabular dysplasia by bone grafting or at a relatively higher position without bone grafting. The bone-ingrowth rate was lower in the group with en bloc bone grafting, and the reactive line was frequently noted in the bone-grafted region. Although no data indicated that en bloc bone grafting directly led to poor outcomes, such as loosening, cup placement at a higher site without bone grafting is now selected by most operators. The polyethylene liner in a cementless cup is thinned due to the metal cup thickness; however, it has been suggested that the apparent relation between the cup size and the wear rate was absent as long as a cementless cup is used. Comparative study indicated cementless THR was inferior with regard to the yearly polyethylene wear rate and incidence of osteolysis on both the stem and cup sides. Meta-analysis study on the survival rate between cement and cementless THR reported that cemented THR was slightly superior. It should be considered that specific problems for cementless THR, especially with regard to polyethylene wear, do occur.
Literature
1.
go back to reference Engh CA Jr, Claus AM, Hopper RH Jr, Engh CA. Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop 2001;393:137–146.CrossRefPubMed Engh CA Jr, Claus AM, Hopper RH Jr, Engh CA. Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop 2001;393:137–146.CrossRefPubMed
2.
go back to reference Engh CA, Hopper RH Jr. The odyssey of porous-coated fixation. J Arthroplasty 2002;17(suppl 1):102–107.PubMed Engh CA, Hopper RH Jr. The odyssey of porous-coated fixation. J Arthroplasty 2002;17(suppl 1):102–107.PubMed
3.
go back to reference Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC. Cementless acetabular fixation at fifteen years: a comparison with the same surgeon’s results following acetabular fixation with cement. J Bone Joint Surg Am 2004;86:257–261.PubMed Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC. Cementless acetabular fixation at fifteen years: a comparison with the same surgeon’s results following acetabular fixation with cement. J Bone Joint Surg Am 2004;86:257–261.PubMed
4.
go back to reference McKee GK, Watson-Farrar J. Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br 1966;48:245–259.PubMed McKee GK, Watson-Farrar J. Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br 1966;48:245–259.PubMed
6.
go back to reference Wroblewski BM, Siney PD, Fleming PA. Charnley low-frictional torque arthroplasty in patients under the age of 51 years: followup to 33 years. J Bone Joint Surg Br 2002;84:540–543.CrossRefPubMed Wroblewski BM, Siney PD, Fleming PA. Charnley low-frictional torque arthroplasty in patients under the age of 51 years: followup to 33 years. J Bone Joint Surg Br 2002;84:540–543.CrossRefPubMed
7.
go back to reference Olsson SS, Jernberger A, Tryggö D. Clinical and radiological long-term results after Charnley-Müller total hip replacement: a 5 to 10 year follow-up study with special reference to aseptic loosening. Acta Orthop Scand 1981;52:531–542.PubMedCrossRef Olsson SS, Jernberger A, Tryggö D. Clinical and radiological long-term results after Charnley-Müller total hip replacement: a 5 to 10 year follow-up study with special reference to aseptic loosening. Acta Orthop Scand 1981;52:531–542.PubMedCrossRef
8.
go back to reference Sutherland CJ, Wilde AH, Borden LS, Marks KE. A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 1982;64:970–982.PubMed Sutherland CJ, Wilde AH, Borden LS, Marks KE. A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 1982;64:970–982.PubMed
9.
go back to reference Ring PA. Complete replacement arthroplasty of the hip by the Ring prosthesis. J Bone Joint Surg Br 1968;50:720–731.PubMed Ring PA. Complete replacement arthroplasty of the hip by the Ring prosthesis. J Bone Joint Surg Br 1968;50:720–731.PubMed
10.
go back to reference Kawamoto K, Hasegawa Y, Iwase T, Iwasada S, Kanamono T, Iwata H. Failed cementless total hip arthroplasty for osteoarthrosis due to hip dysplasia: a minimum five-year follow-up study. Bull Hosp Joint Dis 1998;57:130–135. Kawamoto K, Hasegawa Y, Iwase T, Iwasada S, Kanamono T, Iwata H. Failed cementless total hip arthroplasty for osteoarthrosis due to hip dysplasia: a minimum five-year follow-up study. Bull Hosp Joint Dis 1998;57:130–135.
11.
go back to reference Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop 1990;257:107–128.PubMed Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop 1990;257:107–128.PubMed
12.
go back to reference Engh CA, Massin P. Cementless total hip replacement using the AML stem: 0–10 years results using a survivorship analysis. Nippon Seikeigeka Gakkai Zasshi 1989;63:653–666.PubMed Engh CA, Massin P. Cementless total hip replacement using the AML stem: 0–10 years results using a survivorship analysis. Nippon Seikeigeka Gakkai Zasshi 1989;63:653–666.PubMed
13.
go back to reference Engh CA, Hooten JP Jr, Zettl-Schaffer KF, Ghaffarpour M, McGovern TF, Macalino GE, et al. Porous-coated total hip replacement. Clin Orthop 1994;298:89–96.PubMed Engh CA, Hooten JP Jr, Zettl-Schaffer KF, Ghaffarpour M, McGovern TF, Macalino GE, et al. Porous-coated total hip replacement. Clin Orthop 1994;298:89–96.PubMed
14.
go back to reference Yoshihara Y, Hennmi O, Kawaji Y, Morita M, Date H, Fujikawa K, et al. Assessment of femoral bone resorption after cementless total hip arthroplasty using the AML stem. Hip Joint 2003;29:461–465 (in Japanese). Yoshihara Y, Hennmi O, Kawaji Y, Morita M, Date H, Fujikawa K, et al. Assessment of femoral bone resorption after cementless total hip arthroplasty using the AML stem. Hip Joint 2003;29:461–465 (in Japanese).
15.
go back to reference Yoshihara Y, Shiromoto Y, Kaneko M, Kono T, Ohashi K, Morita M, et al. Change of bone absorption of proximal femur after AML: a cementless total hip arthroplasty. Nippon Jinko Kansetsu Gakkaishi 2006;36:92–93 (in Japanese). Yoshihara Y, Shiromoto Y, Kaneko M, Kono T, Ohashi K, Morita M, et al. Change of bone absorption of proximal femur after AML: a cementless total hip arthroplasty. Nippon Jinko Kansetsu Gakkaishi 2006;36:92–93 (in Japanese).
16.
go back to reference Yoshihara Y, Henmi O, Kawaji Y, Date H, Morita M, Fujikawa K, et al. Quantitative analysis of femoral bone resorption after cementless total hip arthroplasty using AML-A stem. Nippon Jinko Kansetsu Gakkaishi 2003;33:159–160 (in Japanese). Yoshihara Y, Henmi O, Kawaji Y, Date H, Morita M, Fujikawa K, et al. Quantitative analysis of femoral bone resorption after cementless total hip arthroplasty using AML-A stem. Nippon Jinko Kansetsu Gakkaishi 2003;33:159–160 (in Japanese).
17.
go back to reference Bugbee WD, Culpepper WJ 2nd, Engh CA Jr, Engh CA Sr. Longterm clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am 1997;79:1007–1012.PubMed Bugbee WD, Culpepper WJ 2nd, Engh CA Jr, Engh CA Sr. Longterm clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am 1997;79:1007–1012.PubMed
18.
go back to reference Engh CA, Massin P. Cementless total hip arthroplasty using the anatomic medullary locking stem: results using a survivorship analysis. Clin Orthop 1989;249:141–158.PubMed Engh CA, Massin P. Cementless total hip arthroplasty using the anatomic medullary locking stem: results using a survivorship analysis. Clin Orthop 1989;249:141–158.PubMed
19.
go back to reference Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW. Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants: methods and preliminary results. J Bone Joint Surg Br 1993;75:279–287.PubMed Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW. Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants: methods and preliminary results. J Bone Joint Surg Br 1993;75:279–287.PubMed
20.
go back to reference González Della Valle A, Ruzo PS, Li S, Pellicci P, Sculco TP, Salvati EA. Dislodgment of polyethylene liners in first and second-generation Harris-Galante acetabular components: a report of eighteen cases. J Bone Joint Surg Am 2001;83:553–559.PubMed González Della Valle A, Ruzo PS, Li S, Pellicci P, Sculco TP, Salvati EA. Dislodgment of polyethylene liners in first and second-generation Harris-Galante acetabular components: a report of eighteen cases. J Bone Joint Surg Am 2001;83:553–559.PubMed
21.
go back to reference Russotti GM, Harris WH. Proximal placement of the acetabular component in total hip arthroplasty: a long-term follow-up study. J Bone Joint Surg Am 1991;73:587–592.PubMed Russotti GM, Harris WH. Proximal placement of the acetabular component in total hip arthroplasty: a long-term follow-up study. J Bone Joint Surg Am 1991;73:587–592.PubMed
22.
go back to reference Hendricks KJ, Harris WH. High placement of noncemented acetabular components in revision total hip arthroplasty: a concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg Am 2006;88:2231–2236.CrossRefPubMed Hendricks KJ, Harris WH. High placement of noncemented acetabular components in revision total hip arthroplasty: a concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg Am 2006;88:2231–2236.CrossRefPubMed
23.
go back to reference Crowther JD, Lachiewicz PF. Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: results at nine to fourteen years. J Bone Joint Surg Am 2002;84:729–735.CrossRefPubMed Crowther JD, Lachiewicz PF. Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: results at nine to fourteen years. J Bone Joint Surg Am 2002;84:729–735.CrossRefPubMed
24.
go back to reference Shih CH, Lee PC, Chen JH, Tai CL, Chen LF, Wu JS, et al. Measurement of polyethylene wear in cementless total hip arthroplasty. J Bone Joint Surg Br 1997;79:361–365.CrossRefPubMed Shih CH, Lee PC, Chen JH, Tai CL, Chen LF, Wu JS, et al. Measurement of polyethylene wear in cementless total hip arthroplasty. J Bone Joint Surg Br 1997;79:361–365.CrossRefPubMed
25.
go back to reference Roth A, Winzer T, Sander K, Anders JO, Venbrocks RA. Press fit fixation of cementless cups: how much stability do we need indeed? Arch Orthop Trauma Surg 2006;126:77–81.CrossRefPubMed Roth A, Winzer T, Sander K, Anders JO, Venbrocks RA. Press fit fixation of cementless cups: how much stability do we need indeed? Arch Orthop Trauma Surg 2006;126:77–81.CrossRefPubMed
26.
go back to reference Schmalzried TP, Brown IC, Amstutz HC, Engh CA, Harris WH. The role of acetabular component screw holes and/or screws in the development of pelvic osteolysis. Proc Inst Mech Eng [H] 1999;213:147–153. Schmalzried TP, Brown IC, Amstutz HC, Engh CA, Harris WH. The role of acetabular component screw holes and/or screws in the development of pelvic osteolysis. Proc Inst Mech Eng [H] 1999;213:147–153.
27.
go back to reference Chambers B, St. Clair SF, Froimson MI. Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty. J Arthroplasty 2007;22(suppl 1):71–4.CrossRefPubMed Chambers B, St. Clair SF, Froimson MI. Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty. J Arthroplasty 2007;22(suppl 1):71–4.CrossRefPubMed
28.
go back to reference Abrahams TG, Crothers OD. Radiographic analysis of an investigational hydroxyapatite-coated total hip replacement. Invest Radiol 1992;27:779–784.CrossRefPubMed Abrahams TG, Crothers OD. Radiographic analysis of an investigational hydroxyapatite-coated total hip replacement. Invest Radiol 1992;27:779–784.CrossRefPubMed
29.
go back to reference Dorr LD, Wan Z, Song M, Ranawat A. Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation. J Arthroplasty 1998;13:729–736.CrossRefPubMed Dorr LD, Wan Z, Song M, Ranawat A. Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation. J Arthroplasty 1998;13:729–736.CrossRefPubMed
30.
go back to reference Thanner J, Kärrholm J, Herberts P, Malchau H. Porous cups with and without hydroxylapatite-tricalcium phosphate coating: 23 matched pairs evaluated with radiostereometry. J Arthroplasty 1999;14:266–271.CrossRefPubMed Thanner J, Kärrholm J, Herberts P, Malchau H. Porous cups with and without hydroxylapatite-tricalcium phosphate coating: 23 matched pairs evaluated with radiostereometry. J Arthroplasty 1999;14:266–271.CrossRefPubMed
31.
go back to reference Paulsen A, Pedersen AB, Johnsen SP, Riis A, Lucht U, Overgaard S. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry. Acta Orthop 2007;78:622–628.CrossRefPubMed Paulsen A, Pedersen AB, Johnsen SP, Riis A, Lucht U, Overgaard S. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry. Acta Orthop 2007;78:622–628.CrossRefPubMed
32.
go back to reference Belmont PJ Jr, Powers CC, Beykirch SE, Hopper RH Jr, Engh CA Jr, Engh CA. Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years: a concise follow-up of previous reports. J Bone Joint Surg Am 2008;90:1524–1530.CrossRefPubMed Belmont PJ Jr, Powers CC, Beykirch SE, Hopper RH Jr, Engh CA Jr, Engh CA. Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years: a concise follow-up of previous reports. J Bone Joint Surg Am 2008;90:1524–1530.CrossRefPubMed
33.
go back to reference Harada Y, Mitsuhashi S, Suzuki C, Yamashita K, Watanabe H, Akita T, et al. Anatomically designed prosthesis without cement for the treatment of osteoarthritis due to developmental dysplasia of the hip: 6- to 13-year follow-up study. J Orthop Sci 2007;12:127–133.CrossRefPubMed Harada Y, Mitsuhashi S, Suzuki C, Yamashita K, Watanabe H, Akita T, et al. Anatomically designed prosthesis without cement for the treatment of osteoarthritis due to developmental dysplasia of the hip: 6- to 13-year follow-up study. J Orthop Sci 2007;12:127–133.CrossRefPubMed
34.
go back to reference McCombe P, Williams SA. A comparison of polyethylene wear rates between cemented and cementless cups: a prospective, randomised trial. J Bone Joint Surg Br 2004;86:344–349.CrossRefPubMed McCombe P, Williams SA. A comparison of polyethylene wear rates between cemented and cementless cups: a prospective, randomised trial. J Bone Joint Surg Br 2004;86:344–349.CrossRefPubMed
35.
go back to reference Morshed S, Bozic KJ, Ries MD, Malchau H, Colford JM Jr. Comparison of cemented and uncemented fixation in total hip replacement: a meta-analysis. Acta Orthop 2007;78:315–326.CrossRefPubMed Morshed S, Bozic KJ, Ries MD, Malchau H, Colford JM Jr. Comparison of cemented and uncemented fixation in total hip replacement: a meta-analysis. Acta Orthop 2007;78:315–326.CrossRefPubMed
36.
go back to reference Arabmotlagh M, Rittmeister M, Hennigs T. Alendronate prevents femoral periprosthetic bone loss following total hip arthroplasty: prospective randomized double-blind study J Orthop Res 2006;24:1336–1341.CrossRefPubMed Arabmotlagh M, Rittmeister M, Hennigs T. Alendronate prevents femoral periprosthetic bone loss following total hip arthroplasty: prospective randomized double-blind study J Orthop Res 2006;24:1336–1341.CrossRefPubMed
37.
go back to reference Bhandari M, Bajammal S, Guyatt GH, Griffith L, Busse JW, Schünemann H, et al. Effect of bisphosphonates on periprosthetic bone mineral density after total joint arthroplasty: a meta-analysis. J Bone Joint Surg Am 2005;87:293–301.CrossRefPubMed Bhandari M, Bajammal S, Guyatt GH, Griffith L, Busse JW, Schünemann H, et al. Effect of bisphosphonates on periprosthetic bone mineral density after total joint arthroplasty: a meta-analysis. J Bone Joint Surg Am 2005;87:293–301.CrossRefPubMed
38.
go back to reference Peter B, Pioletti DP, Laïb S, Bujoli B, Pilet P, Janvier P, et al. Calcium phosphate drug delivery system: influence of local zoledronate release on bone implant osteointegration. Bone 2005;36:52–60.CrossRefPubMed Peter B, Pioletti DP, Laïb S, Bujoli B, Pilet P, Janvier P, et al. Calcium phosphate drug delivery system: influence of local zoledronate release on bone implant osteointegration. Bone 2005;36:52–60.CrossRefPubMed
39.
go back to reference Malchau H, Herberts P, Eisler T, Garellick G, Söderman P. The Swedish Total Hip Replacement Register. J Bone Joint Surg Am 2002;84(suppl 2):2–20.PubMed Malchau H, Herberts P, Eisler T, Garellick G, Söderman P. The Swedish Total Hip Replacement Register. J Bone Joint Surg Am 2002;84(suppl 2):2–20.PubMed
Metadata
Title
Cementless total hip replacement: past, present, and future
Authors
Harumoto Yamada
Yasuo Yoshihara
Osamu Henmi
Mitsuhiro Morita
Yuichiro Shiromoto
Tomoki Kawano
Arihiko Kanaji
Kennichi Ando
Masato Nakagawa
Naoto Kosaki
Eiichi Fukaya
Publication date
01-03-2009
Publisher
Springer-Verlag
Published in
Journal of Orthopaedic Science / Issue 2/2009
Print ISSN: 0949-2658
Electronic ISSN: 1436-2023
DOI
https://doi.org/10.1007/s00776-008-1317-4

Other articles of this Issue 2/2009

Journal of Orthopaedic Science 2/2009 Go to the issue