Abstract

Background

Registration accuracy is a main factor influencing overall navigation accuracy. Standard fiducial- or landmark-based patient registration is user dependent and error-prone. Intraoperative imaging offers the possibility for user-independent patient registration. The aim of this paper is to evaluate our initial experience applying intraoperative computed tomography (CT) for navigation registration in cranial neurosurgery, with a special focus on registration accuracy and effective radiation dose.

Methods

A total of 200 patients (141 craniotomy, 19 transsphenoidal, and 40 stereotactic burr hole procedures) were investigated by intraoperative CT applying a 32-slice movable CT scanner, which was used for automatic navigation registration. Registration accuracy was measured by at least three skin fiducials that were not part of the registration process.

Results

Automatic registration resulted in high registration accuracy (mean registration error: 0.93 ± 0.41 mm). Implementation of low-dose scanning protocols did not impede registration accuracy (registration error applying the full dose head protocol: 0.87 ± 0.36 mm vs. the low dose sinus protocol 0.72 ± 0.43 mm) while a reduction of the effective radiation dose by a factor of 8 could be achieved (mean effective radiation dose head protocol: 2.73 mSv vs. sinus protocol: 0.34 mSv).

Conclusion

Intraoperative CT allows highly reliable navigation registration with low radiation exposure.
Literature
1.
go back to reference Black PM, Moriarty T, Alexander E 3rd, Stieg P, Woodard EJ, Gleason PL, Martin CH, Kikinis R, Schwartz RB, Jolesz FA (1997) Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. Neurosurgery 41:831–842 discussion 842-835CrossRefPubMed Black PM, Moriarty T, Alexander E 3rd, Stieg P, Woodard EJ, Gleason PL, Martin CH, Kikinis R, Schwartz RB, Jolesz FA (1997) Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. Neurosurgery 41:831–842 discussion 842-835CrossRefPubMed
4.
go back to reference Butler WE, Piaggio CM, Constantinou C, Niklason L, Gonzalez RG, Cosgrove GR, Zervas NT (1998) A mobile computed tomographic scanner with intraoperative and intensive care unit applications. Neurosurgery 42:1304–1310 discussion 1310-1301CrossRefPubMed Butler WE, Piaggio CM, Constantinou C, Niklason L, Gonzalez RG, Cosgrove GR, Zervas NT (1998) A mobile computed tomographic scanner with intraoperative and intensive care unit applications. Neurosurgery 42:1304–1310 discussion 1310-1301CrossRefPubMed
6.
go back to reference Coburger J, Merkel A, Scherer M, Schwartz F, Gessler F, Roder C, Pala A, Konig R, Bullinger L, Nagel G, Jungk C, Bisdas S, Nabavi A, Ganslandt O, Seifert V, Tatagiba M, Senft C, Mehdorn M, Unterberg AW, Rossler K, Wirtz CR (2016) Low-grade glioma surgery in intraoperative magnetic resonance imaging: results of a multicenter retrospective assessment of the German study Group for Intraoperative Magnetic Resonance Imaging. Neurosurgery 78:775–786. https://doi.org/10.1227/NEU.0000000000001081 CrossRefPubMed Coburger J, Merkel A, Scherer M, Schwartz F, Gessler F, Roder C, Pala A, Konig R, Bullinger L, Nagel G, Jungk C, Bisdas S, Nabavi A, Ganslandt O, Seifert V, Tatagiba M, Senft C, Mehdorn M, Unterberg AW, Rossler K, Wirtz CR (2016) Low-grade glioma surgery in intraoperative magnetic resonance imaging: results of a multicenter retrospective assessment of the German study Group for Intraoperative Magnetic Resonance Imaging. Neurosurgery 78:775–786. https://​doi.​org/​10.​1227/​NEU.​0000000000001081​ CrossRefPubMed
17.
go back to reference Ketcha MD, de Silva T, Han R, Uneri A, Goerres J, Jacobson M, Vogt S, Kleinszig G, Siewerdsen JH (2017) Fundamental limits of image registration performance: Effects of image noise and resolution in CT-guided interventions. Proc SPIE Int Soc Opt Eng 10135. doi: 10.1117/12.2256025 Ketcha MD, de Silva T, Han R, Uneri A, Goerres J, Jacobson M, Vogt S, Kleinszig G, Siewerdsen JH (2017) Fundamental limits of image registration performance: Effects of image noise and resolution in CT-guided interventions. Proc SPIE Int Soc Opt Eng 10135. doi: 10.1117/12.2256025
22.
go back to reference Lunsford LD, Parrish R, Albright L (1984) Intraoperative imaging with a therapeutic computed tomographic scanner. Neurosurgery 15:559–561CrossRefPubMed Lunsford LD, Parrish R, Albright L (1984) Intraoperative imaging with a therapeutic computed tomographic scanner. Neurosurgery 15:559–561CrossRefPubMed
23.
go back to reference Mirzayan MJ, von Roden M, Bulacio J, von Podewils F, Gonzalez-Martinez J (2016) The usefulness of intraoperative cerebral C-arm CT angiogram for implantation of intracranial depth electrodes in stereotactic electroencephalography procedure. Stereotact Funct Neurosurg 94:10–17. https://doi.org/10.1159/000431372 CrossRefPubMed Mirzayan MJ, von Roden M, Bulacio J, von Podewils F, Gonzalez-Martinez J (2016) The usefulness of intraoperative cerebral C-arm CT angiogram for implantation of intracranial depth electrodes in stereotactic electroencephalography procedure. Stereotact Funct Neurosurg 94:10–17. https://​doi.​org/​10.​1159/​000431372 CrossRefPubMed
27.
go back to reference Okudera H, Kobayashi S, Kyoshima K, Gibo H, Takemae T, Sugita K (1991) Development of the operating computerized tomographic scanner system for neurosurgery. Acta Neurochir 111:61–63CrossRefPubMed Okudera H, Kobayashi S, Kyoshima K, Gibo H, Takemae T, Sugita K (1991) Development of the operating computerized tomographic scanner system for neurosurgery. Acta Neurochir 111:61–63CrossRefPubMed
32.
go back to reference Shalit MN, Israeli Y, Matz S, Cohen ML (1979) Intra-operative computerized axial tomography. Surg Neurol 11:382–384PubMed Shalit MN, Israeli Y, Matz S, Cohen ML (1979) Intra-operative computerized axial tomography. Surg Neurol 11:382–384PubMed
35.
go back to reference Steinmeier R, Fahlbusch R, Ganslandt O, Nimsky C, Buchfelder M, Kaus M, Heigl T, Lenz G, Kuth R, Huk W (1998) Intraoperative magnetic resonance imaging with the magnetom open scanner: concepts, neurosurgical indications, and procedures: a preliminary report. Neurosurgery 43:739–747 discussion 747-738CrossRefPubMed Steinmeier R, Fahlbusch R, Ganslandt O, Nimsky C, Buchfelder M, Kaus M, Heigl T, Lenz G, Kuth R, Huk W (1998) Intraoperative magnetic resonance imaging with the magnetom open scanner: concepts, neurosurgical indications, and procedures: a preliminary report. Neurosurgery 43:739–747 discussion 747-738CrossRefPubMed
Metadata
Title
Intraoperative computed tomography as reliable navigation registration device in 200 cranial procedures
Authors
Barbara Carl
Miriam Bopp
Benjamin Saß
Christopher Nimsky
Publication date
01-09-2018
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 9/2018
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-018-3641-6

Other articles of this Issue 9/2018

Acta Neurochirurgica 9/2018 Go to the issue