01-06-2018 | Original Article - Vascular

Predictors of antegrade flow at internal carotid artery during carotid artery stenting with proximal protection

Authors: Kei Harada, Kosuke Kakumoto, Shogo Oshikata, Kozo Fukuyama

Published in: Acta Neurochirurgica | Issue 6/2018

Login to get access

Abstract

Background

Carotid artery stenting (CAS) with proximal occlusion effectively prevent distal cerebral embolism by flow arrest at internal carotid artery (ICA); however, the method can expose antegrade flow at ICA due to incomplete flow arrest. The aim of this study was to identify predictors of antegrade flow during CAS with proximal protection.

Methods

We retrospectively analyzed clinical and angiographic data among 143 lesions treated with CAS with proximal protection by occluding the common carotid artery (CCA) and external carotid artery (ECA). Flow arrest or antegrade flow at ICA was confirmed by contrast injection during proximal protection.

Results

Antegrade flow at ICA was observed in 12 lesions (8.4%). Compared with lesions in which flow arrest of ICA was achieved, the diameter of the superior thyroid artery (STA) was significantly larger (2.4 ± 0.34 vs. 1.4 ± 0.68 mm, p < 0.001), and the rate of ECA branches other than the STA located 0–10 mm above the bifurcation was significantly higher (50 vs. 8.4%, p < 0.001). Results of multivariate analysis revealed that a diameter of the STA ≥ 2.3 mm (OR 44, 95% CI 8.1–237; p < 0.001) and ECA branches other than the STA located 0–10 mm above the bifurcation (OR 6.0, 95% CI 1.1–32; p = 0.036) were independent predictors of antegrade flow.

Conclusions

Distal filter protection should be combined with proximal protection for the lesions with antegrade flow to prevent distal migration of the carotid debris.
Literature
1.
go back to reference Acar M, Salbacak A, Sakarya ME, Zararsiz I, Ulusoy M (2013) The morphometrical analysis of the external carotid artery and its branches with multidetector computerized tomography angiography technique. Int J Morphol 31:1407–1414CrossRef Acar M, Salbacak A, Sakarya ME, Zararsiz I, Ulusoy M (2013) The morphometrical analysis of the external carotid artery and its branches with multidetector computerized tomography angiography technique. Int J Morphol 31:1407–1414CrossRef
2.
go back to reference Cassese S, Ndrepepa G, King LA, Nerad M, Schunkert H, Kastrati A, Ott I, FUsaro M (2015) Proximal occlusion versus distal filter for cerebral protection during carotid stenting: updated meta-analysis of randomised and observational MRI studies. EuroIntervention 11:238–246CrossRefPubMed Cassese S, Ndrepepa G, King LA, Nerad M, Schunkert H, Kastrati A, Ott I, FUsaro M (2015) Proximal occlusion versus distal filter for cerebral protection during carotid stenting: updated meta-analysis of randomised and observational MRI studies. EuroIntervention 11:238–246CrossRefPubMed
3.
go back to reference Cavalcanti DD, Reis CV, Hanel R, Safavi-Abbasi S, Deshmukh P, Spetzler RF, Preul MC (2009) The ascending pharyngeal artery and its relevance for neurosurgical and endovascular procedures. Neurosurgery 65(Suppl):114–120PubMed Cavalcanti DD, Reis CV, Hanel R, Safavi-Abbasi S, Deshmukh P, Spetzler RF, Preul MC (2009) The ascending pharyngeal artery and its relevance for neurosurgical and endovascular procedures. Neurosurgery 65(Suppl):114–120PubMed
4.
go back to reference Fazan VP, da Silva JH, Borges CT, Ribeiro RA, Caetano AG, Filho OA (2009) An anatomical study on the lingual–facial trunk. Surg Radiol Anat 31:267–270CrossRefPubMed Fazan VP, da Silva JH, Borges CT, Ribeiro RA, Caetano AG, Filho OA (2009) An anatomical study on the lingual–facial trunk. Surg Radiol Anat 31:267–270CrossRefPubMed
5.
go back to reference Giugliano G, Stabile E, Biamino G, Petroni G, Sannino A, Brevetti L, Pucciarelli A, Popusoi G, Tesorio T, Cioppa A, Cota L, Salemme L, Sorropago A, Ausania A, Pietra GD, Fontanelli A, Trimarco B, Esposito G, Bubino P (2014) Predictors of carotid occlusion intolerance during proximal protected carotid arterystenting. JACC Cardiovasc Interv 7:1237–1244CrossRefPubMed Giugliano G, Stabile E, Biamino G, Petroni G, Sannino A, Brevetti L, Pucciarelli A, Popusoi G, Tesorio T, Cioppa A, Cota L, Salemme L, Sorropago A, Ausania A, Pietra GD, Fontanelli A, Trimarco B, Esposito G, Bubino P (2014) Predictors of carotid occlusion intolerance during proximal protected carotid arterystenting. JACC Cardiovasc Interv 7:1237–1244CrossRefPubMed
6.
go back to reference Harada K, Kakumoto K, Morioka J, Saito T, Fukuyama K (2014) Combination of flow reversal and distal filter for cerebral protection during carotid artery stenting. Ann Vasc Surg 28:651–658CrossRefPubMed Harada K, Kakumoto K, Morioka J, Saito T, Fukuyama K (2014) Combination of flow reversal and distal filter for cerebral protection during carotid artery stenting. Ann Vasc Surg 28:651–658CrossRefPubMed
7.
go back to reference Hayashi N, Hori E, Ohtami Y, Ohtani O, Kuwayama N, Endo S (2005) Surgical anatomy of the cervical carotid artery for carotid endarterecromy. Neuro Med Chir (Tokyo) 45:20–30CrossRef Hayashi N, Hori E, Ohtami Y, Ohtani O, Kuwayama N, Endo S (2005) Surgical anatomy of the cervical carotid artery for carotid endarterecromy. Neuro Med Chir (Tokyo) 45:20–30CrossRef
8.
go back to reference Klosek SK, Rungruang T (2008) Topography of carotid bifurcation: considerations for neck examination. Surg Radiol Anat 30:383–387CrossRefPubMed Klosek SK, Rungruang T (2008) Topography of carotid bifurcation: considerations for neck examination. Surg Radiol Anat 30:383–387CrossRefPubMed
9.
go back to reference Knappich C, Kuehnl A, Tsantilas P, Schmid S, Breitkreuz T, Kallmayer M, Zimmermann A, Eckstein HH (2017) The use of embolic protection devices is associated with a lower stroke and death rate after carotid stenting. JACC Cardiovasc Interv 10:1257–1265CrossRefPubMed Knappich C, Kuehnl A, Tsantilas P, Schmid S, Breitkreuz T, Kallmayer M, Zimmermann A, Eckstein HH (2017) The use of embolic protection devices is associated with a lower stroke and death rate after carotid stenting. JACC Cardiovasc Interv 10:1257–1265CrossRefPubMed
10.
go back to reference Lo A, Oehley M, Bartlett A, Adams D, Blyth P, Al-Ali S (2006) Anatomical variations of the common carotid artery bifurcation. ANZ J Surg 76:970–972CrossRefPubMed Lo A, Oehley M, Bartlett A, Adams D, Blyth P, Al-Ali S (2006) Anatomical variations of the common carotid artery bifurcation. ANZ J Surg 76:970–972CrossRefPubMed
11.
go back to reference Natsis K, Raikos A, Foundos I, Noussios G, Lazaridis N, Njau SN (2011) Superior thyroid artery origin in Caucasian Greeks: a new classification proposal and review of the literature. Clin Anat 24:699–705CrossRefPubMed Natsis K, Raikos A, Foundos I, Noussios G, Lazaridis N, Njau SN (2011) Superior thyroid artery origin in Caucasian Greeks: a new classification proposal and review of the literature. Clin Anat 24:699–705CrossRefPubMed
12.
go back to reference Omran J, Mahmud E, White CJ, Aronow HD, Drachman DE, Gray W, Abdullah O, Abu-Fadel M, Firwana B, Mishkel G, Al-Dadah AS (2017) Proximal balloon occlusion versus distal filter protection in carotid artery stenting: a meta-analysis and review of the literature. Catheter Cardiovasc Interv 89:923–931CrossRefPubMed Omran J, Mahmud E, White CJ, Aronow HD, Drachman DE, Gray W, Abdullah O, Abu-Fadel M, Firwana B, Mishkel G, Al-Dadah AS (2017) Proximal balloon occlusion versus distal filter protection in carotid artery stenting: a meta-analysis and review of the literature. Catheter Cardiovasc Interv 89:923–931CrossRefPubMed
13.
go back to reference Ozgur Z, Govsa F, Ozgur T (2008) Assessment of origin characteristics of the front branches of the external carotidartery. J Craniofac Surg 19:1159–1166CrossRefPubMed Ozgur Z, Govsa F, Ozgur T (2008) Assessment of origin characteristics of the front branches of the external carotidartery. J Craniofac Surg 19:1159–1166CrossRefPubMed
14.
go back to reference Stabile E, Sannino A, Schiattarella GG, Gargiulo G, Toscano E, Brevetti L, Scudiero F, Gingliano G, Perrino C, Trimarco B, Esposito G (2014) Cerebral embolic lesions detected with diffusion-weighted magnetic resonance imaging following carotid artery stenting: a meta-analysis of 8 studies comparing filter cerebral protection and proximal balloon occlusion. JACC Cardiovasc Interv 7:1177–1183CrossRefPubMed Stabile E, Sannino A, Schiattarella GG, Gargiulo G, Toscano E, Brevetti L, Scudiero F, Gingliano G, Perrino C, Trimarco B, Esposito G (2014) Cerebral embolic lesions detected with diffusion-weighted magnetic resonance imaging following carotid artery stenting: a meta-analysis of 8 studies comparing filter cerebral protection and proximal balloon occlusion. JACC Cardiovasc Interv 7:1177–1183CrossRefPubMed
Metadata
Title
Predictors of antegrade flow at internal carotid artery during carotid artery stenting with proximal protection
Authors
Kei Harada
Kosuke Kakumoto
Shogo Oshikata
Kozo Fukuyama
Publication date
01-06-2018
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 6/2018
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-018-3487-y

Other articles of this Issue 6/2018

Acta Neurochirurgica 6/2018 Go to the issue