Abstract

Background

Deep brain stimulation (DBS) of the sub-thalamic nucleus (STN) is a recognised treatment for advanced Parkinson’s disease (PD). We present our results of 10 consecutive patients implanted under general anaesthesia (GA) using intraoperative robotic three-dimensional (3D) fluoroscopy (Artis Zeego; Siemens, Erlangen, Germany).

Method

Ten patients (nine men, one woman) with a mean age of 57.6 (range, 41–67) years underwent surgery between October 2013 and January 2015. The mean duration of PD was 9.2 [110] year. The procedure was performed under GA: placement of the stereotactic frame, implantation of the electrodes (Lead 3389; Medtronic, Minnesota, MN, USA) and 3D intraoperative fluoroscopic control (Artis Zeego) with image fusion with the preoperative MRI scans. All patients were evaluated preoperatively and 6 months postoperatively.

Results

The mean operative time was 240.1 (185–325) min. The mean Unified Parkinson’s Disease Rating Scale (UPDRS) II OFF medication decreased from 23.9 preoperatively to 15.7 postoperatively. The mean OFF medication UPDRS III decreased from 41 to 11.6 and the UPDRS IV decreased from 10.6 to 7. The mean preoperative and postoperative L-Dopa doses were 1,178.5 and 696.5 mg, respectively. Two complications were recorded: one episode of transient confusion (24 h) and one internal pulse generator (IPG) infection.

Conclusions

With improvement in preoperative magnetic resonance imaging (MRI) and the ability to control the position of the leads intraoperatively using Artis Zeego, we now perform this procedure under GA. Our results are comparable to others reported. The significant decrease in the duration of surgery could be associated with a reduced rate of complications (infection, loss of patient collaboration). However, this observation needs to be confirmed.
Literature
1.
go back to reference Fiegele T, Feuchtner G, Sohm F, Bauer R, Anton JVF, Gotwald T, Twerdy K, Eisner W (2008) Accuracy of stereotactic electrode placement in deep brain stimulation by intraoperative computed tomography. Parkinsonism Relat Disord 14:595–599CrossRefPubMed Fiegele T, Feuchtner G, Sohm F, Bauer R, Anton JVF, Gotwald T, Twerdy K, Eisner W (2008) Accuracy of stereotactic electrode placement in deep brain stimulation by intraoperative computed tomography. Parkinsonism Relat Disord 14:595–599CrossRefPubMed
2.
go back to reference Foltynie T, Zrinzo L, Martines-Torres I, Tripoliti E, Petersen I, Holl E, Aviles-Olmos I, Jahanshahi M, Hariz M, Limousin P (2011) MRI-guided STN DBS in Parkinson’s disease without microelectrode recording: efficacy and safety. J Neurol Neurosurg Psychiatry 82:358–363CrossRefPubMed Foltynie T, Zrinzo L, Martines-Torres I, Tripoliti E, Petersen I, Holl E, Aviles-Olmos I, Jahanshahi M, Hariz M, Limousin P (2011) MRI-guided STN DBS in Parkinson’s disease without microelectrode recording: efficacy and safety. J Neurol Neurosurg Psychiatry 82:358–363CrossRefPubMed
3.
go back to reference Hamid NA, Mitchell RD, Mocroft P, Westby GW, Milner J, Pall H (2005) Targeting the subthalamic nucleus for deep brain stimulation: technical approach and fusion of pre- and postoperative MR images to define accuracy of lead placement. J Neurol Neurosurg Psychiatry 76(3):409–14CrossRefPubMedPubMedCentral Hamid NA, Mitchell RD, Mocroft P, Westby GW, Milner J, Pall H (2005) Targeting the subthalamic nucleus for deep brain stimulation: technical approach and fusion of pre- and postoperative MR images to define accuracy of lead placement. J Neurol Neurosurg Psychiatry 76(3):409–14CrossRefPubMedPubMedCentral
4.
go back to reference Holl E, Petersen E, Foltynie T, Martinez-Torres I, Limousin P, Hariz M, Zrinzo L (2010) Improving targeting in image-guided frame-based deep brain stimulation. Neurosurgery 67(2 Suppl Operative):437–447PubMed Holl E, Petersen E, Foltynie T, Martinez-Torres I, Limousin P, Hariz M, Zrinzo L (2010) Improving targeting in image-guided frame-based deep brain stimulation. Neurosurgery 67(2 Suppl Operative):437–447PubMed
5.
go back to reference Holloway K, Docef A (2013) A quantitative assessment of the accuracy and reliability of O-arm images for deep brain stimulation surgery. Neurosurgery 72(1 Suppl Operative):47–57PubMed Holloway K, Docef A (2013) A quantitative assessment of the accuracy and reliability of O-arm images for deep brain stimulation surgery. Neurosurgery 72(1 Suppl Operative):47–57PubMed
6.
go back to reference Lee DJ, Zwienenberg-Lee M, Seyal M, Shahlaie K (2015) Intraoperative computed tomography for intracranial electrode implantation surgery in medically refractory epilepsy. J Neurosurg 122(3):526–531CrossRefPubMed Lee DJ, Zwienenberg-Lee M, Seyal M, Shahlaie K (2015) Intraoperative computed tomography for intracranial electrode implantation surgery in medically refractory epilepsy. J Neurosurg 122(3):526–531CrossRefPubMed
7.
go back to reference Maldonado IL, Roujeau T, Cif L, Gonzalez V, El-Fertit H, Vasques X, Bonafe A, Coubes P (2009) Magnetic resonance-based deep brain stimulation technique: a series of 478 Consecutive implanted electrodes with no perioperative intracerebral hemorrhage. Neurosurgery 65(1 Suppl Operative):196–202PubMed Maldonado IL, Roujeau T, Cif L, Gonzalez V, El-Fertit H, Vasques X, Bonafe A, Coubes P (2009) Magnetic resonance-based deep brain stimulation technique: a series of 478 Consecutive implanted electrodes with no perioperative intracerebral hemorrhage. Neurosurgery 65(1 Suppl Operative):196–202PubMed
8.
go back to reference Maltête D, Navarro S, Welter ML, Roche S, Bonnet AM, Houeto JL, Mesnage V, Pidoux B, Dormont D, Cornu P, Agid Y (2004) Subthalamic stimulation in parkinson disease: with or without anesthesia? Arch Neurol 691(3):390–392CrossRef Maltête D, Navarro S, Welter ML, Roche S, Bonnet AM, Houeto JL, Mesnage V, Pidoux B, Dormont D, Cornu P, Agid Y (2004) Subthalamic stimulation in parkinson disease: with or without anesthesia? Arch Neurol 691(3):390–392CrossRef
9.
go back to reference Mirzadeh Z, Chapple K, Lambert M, Dhall R, Ponce F (2014) Validation of Ct-MRI fusion for intraoperative assessment of stereotactic accuracy in DBS surgery. Mov Disord 29(14):1788–1794CrossRefPubMed Mirzadeh Z, Chapple K, Lambert M, Dhall R, Ponce F (2014) Validation of Ct-MRI fusion for intraoperative assessment of stereotactic accuracy in DBS surgery. Mov Disord 29(14):1788–1794CrossRefPubMed
10.
go back to reference Moll CK, Payer S, Gulberti A, Sharrott A, Zittel S, Boelmans K, Köppen J, Gerloff C, Westphal M, Engel AK, Oehlwein C, Buhmann C, Hamel W (2013) STN stimulation in general anaesthesia: evidence beyond ‘evidence-based medicine’. Acta Neurochir Suppl 117:19–25PubMed Moll CK, Payer S, Gulberti A, Sharrott A, Zittel S, Boelmans K, Köppen J, Gerloff C, Westphal M, Engel AK, Oehlwein C, Buhmann C, Hamel W (2013) STN stimulation in general anaesthesia: evidence beyond ‘evidence-based medicine’. Acta Neurochir Suppl 117:19–25PubMed
11.
go back to reference Alterman RL, Weisz D (2012) Microelectrode recording during deep brain stimulation and ablative procedures. Mov Disord 287:1347–1391CrossRef Alterman RL, Weisz D (2012) Microelectrode recording during deep brain stimulation and ablative procedures. Mov Disord 287:1347–1391CrossRef
12.
go back to reference Shahlaie K, Larson PS, Starr PA (2011) Intraoperative computed tomography for deep brain stimulation surgery: technique and accuracy assessment. Neurosurgery 68(1 Suppl Operative):114–124PubMed Shahlaie K, Larson PS, Starr PA (2011) Intraoperative computed tomography for deep brain stimulation surgery: technique and accuracy assessment. Neurosurgery 68(1 Suppl Operative):114–124PubMed
13.
go back to reference Weaver FM, Follett K, Stern M, Hur K, Harris C, Marks WJ Jr, Rothlind J, Sagher O, Reda D, Moy CS, Pahwa R, Burchiel K, Hogarth P, Lai EC, Duda JE, Holloway K, Samii A, Horn S, Bronstein J, Stoner G, Heemskerk J, Huang GD, CSP 468 Study Group (2009) Bilateral deep brain stimulation vs best medical therapy for patients with advanced Parkinson disease: a randomized controlled trial. JAMA 3001:63–73CrossRef Weaver FM, Follett K, Stern M, Hur K, Harris C, Marks WJ Jr, Rothlind J, Sagher O, Reda D, Moy CS, Pahwa R, Burchiel K, Hogarth P, Lai EC, Duda JE, Holloway K, Samii A, Horn S, Bronstein J, Stoner G, Heemskerk J, Huang GD, CSP 468 Study Group (2009) Bilateral deep brain stimulation vs best medical therapy for patients with advanced Parkinson disease: a randomized controlled trial. JAMA 3001:63–73CrossRef
14.
go back to reference Burchiel KJ, McCartney S, Lee A, Raslan AM (2013) Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording. J Neurosurg 119(2):301–6CrossRefPubMed Burchiel KJ, McCartney S, Lee A, Raslan AM (2013) Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording. J Neurosurg 119(2):301–6CrossRefPubMed
15.
go back to reference Burchiel KJ, Anderson VC, Favre J, Hammerstad JP (1999) Comparison of pallidal and subthalamic nucleus deep brain stimulation for advanced Parkinson’s disease: results of a randomized, blinded pilot study. Neurosurgery 45:1375–1382CrossRefPubMed Burchiel KJ, Anderson VC, Favre J, Hammerstad JP (1999) Comparison of pallidal and subthalamic nucleus deep brain stimulation for advanced Parkinson’s disease: results of a randomized, blinded pilot study. Neurosurgery 45:1375–1382CrossRefPubMed
16.
go back to reference Deuschl G, Schade-Brittinger C, Krack P, Volkmann J, Schäfer H, Bötzel K, Daniels C, Deutschländer A, Dillmann U, Eisner W, Gruber D, Hamel W, Herzog J, Hilker R, Klebe S, Kloss M, Koy J, Krause M, Kupsch A, Lorenz D, Lorenzl S, Mehdorn HM, Moringlane JR, Oertel W, Pinsker MO, Reichmann H, Reuss A, Schneider GH, Schnitzler A, Steude U, Sturm V, Timmermann L, Tronnier V, Trottenberg T, Wojtecki L, Wolf E, Poewe W, Voges J, German Parkinson Study Group, Neurostimulation Section (2006) A randomized trial of deep brain stimulation for Parkinson’s disease. N Engl J Med 355:896–908CrossRefPubMed Deuschl G, Schade-Brittinger C, Krack P, Volkmann J, Schäfer H, Bötzel K, Daniels C, Deutschländer A, Dillmann U, Eisner W, Gruber D, Hamel W, Herzog J, Hilker R, Klebe S, Kloss M, Koy J, Krause M, Kupsch A, Lorenz D, Lorenzl S, Mehdorn HM, Moringlane JR, Oertel W, Pinsker MO, Reichmann H, Reuss A, Schneider GH, Schnitzler A, Steude U, Sturm V, Timmermann L, Tronnier V, Trottenberg T, Wojtecki L, Wolf E, Poewe W, Voges J, German Parkinson Study Group, Neurostimulation Section (2006) A randomized trial of deep brain stimulation for Parkinson’s disease. N Engl J Med 355:896–908CrossRefPubMed
17.
go back to reference Patel NK, Plaha P, O’Sullivan K, McCartner R, Heywood P, Gill SS (2003) MRI directed bilateral stimulation of the subthalamic nucleus in patients with Parkinson’s disease. J Neurol Neurosurg Psychiatry 74:1631–1637CrossRefPubMedPubMedCentral Patel NK, Plaha P, O’Sullivan K, McCartner R, Heywood P, Gill SS (2003) MRI directed bilateral stimulation of the subthalamic nucleus in patients with Parkinson’s disease. J Neurol Neurosurg Psychiatry 74:1631–1637CrossRefPubMedPubMedCentral
18.
go back to reference Patel NK, Plaha P, Gill SS (2007) Magnetic resonance imaging-directed method for functional neurosurgery using implantable guide tubes. Neurosurgery 61(2 Suppl Operative):358–366PubMed Patel NK, Plaha P, Gill SS (2007) Magnetic resonance imaging-directed method for functional neurosurgery using implantable guide tubes. Neurosurgery 61(2 Suppl Operative):358–366PubMed
19.
go back to reference Sutcliffe AJ, Gan YC, Mitchell RD, Mocroft AP, Nightingale P (2011) General anaesthesia for deep brain stimulator electrode insertion in Parkinson’s disease. Acta Neurochir 153:621–627CrossRefPubMed Sutcliffe AJ, Gan YC, Mitchell RD, Mocroft AP, Nightingale P (2011) General anaesthesia for deep brain stimulator electrode insertion in Parkinson’s disease. Acta Neurochir 153:621–627CrossRefPubMed
20.
go back to reference Montgomery EB Jr (2012) Microelectrode targeting of the subthalamic nucleus for deep brain stimulation surgery. Mov Disord 27:1387–1391CrossRefPubMed Montgomery EB Jr (2012) Microelectrode targeting of the subthalamic nucleus for deep brain stimulation surgery. Mov Disord 27:1387–1391CrossRefPubMed
21.
go back to reference Sillay KA, Rusy D, Buyan-Dent L, Ninman NL, Vigen KK (2014) Wide-bore 1.5T MRI-guided deep brain stimulation surgery: initial experience and technique comparison. Clin Neurol Neurosurg 127:79–85CrossRefPubMed Sillay KA, Rusy D, Buyan-Dent L, Ninman NL, Vigen KK (2014) Wide-bore 1.5T MRI-guided deep brain stimulation surgery: initial experience and technique comparison. Clin Neurol Neurosurg 127:79–85CrossRefPubMed
22.
go back to reference Binder DK, Rau GM, Starr PA (2005) Risk factor for hemorrhage during microelectrode-guided deep brain stimumlator implantation for movement disorders. Neurosurgery 56(4):722–732CrossRefPubMed Binder DK, Rau GM, Starr PA (2005) Risk factor for hemorrhage during microelectrode-guided deep brain stimumlator implantation for movement disorders. Neurosurgery 56(4):722–732CrossRefPubMed
23.
go back to reference Pahwa R, Lyons KE (2013) Handbook of Parkinson’s disease, 5th edn. CRC Press, Boca Raton Pahwa R, Lyons KE (2013) Handbook of Parkinson’s disease, 5th edn. CRC Press, Boca Raton
24.
go back to reference Schuepbach WM, Rau J, Knudsen K, Volkmann J, Krack P, Timmermann L, Hälbig TD, Hesekamp H, Navarro SM, Meier N, Falk D, Mehdorn M, Paschen S, Maarouf M, Barbe MT, Fink GR, Kupsch A, Gruber D, Schneider GH, Seigneuret E, Kistner A, Chaynes P, Ory-Magne F, Brefel Courbon C, Vesper J, Schnitzler A, Wojtecki L, Houeto JL, Bataille B, Maltête D, Damier P, Raoul S, Sixel-Doering F, Hellwig D, Gharabaghi A, Krüger R, Pinsker MO, Amtage F, Régis JM, Witjas T, Thobois S, Mertens P, Kloss M, Hartmann A, Oertel WH, Post B, Speelman H, Agid Y, Schade-Brittinger C, Deuschl G, EARLYSTIM Study Group (2013) Neurostimulation for Parkinson’s disease with early motor complications. N Engl J Med 368:610–622CrossRefPubMed Schuepbach WM, Rau J, Knudsen K, Volkmann J, Krack P, Timmermann L, Hälbig TD, Hesekamp H, Navarro SM, Meier N, Falk D, Mehdorn M, Paschen S, Maarouf M, Barbe MT, Fink GR, Kupsch A, Gruber D, Schneider GH, Seigneuret E, Kistner A, Chaynes P, Ory-Magne F, Brefel Courbon C, Vesper J, Schnitzler A, Wojtecki L, Houeto JL, Bataille B, Maltête D, Damier P, Raoul S, Sixel-Doering F, Hellwig D, Gharabaghi A, Krüger R, Pinsker MO, Amtage F, Régis JM, Witjas T, Thobois S, Mertens P, Kloss M, Hartmann A, Oertel WH, Post B, Speelman H, Agid Y, Schade-Brittinger C, Deuschl G, EARLYSTIM Study Group (2013) Neurostimulation for Parkinson’s disease with early motor complications. N Engl J Med 368:610–622CrossRefPubMed
25.
go back to reference Zhang J, Weir V, Fajardo L, Lin J, Hsiung H, Ritenour ER (2009) Dosimetric characterization of a cone-beam O-arm imaging system. J Xray Sci Technol 17(4):305–317PubMed Zhang J, Weir V, Fajardo L, Lin J, Hsiung H, Ritenour ER (2009) Dosimetric characterization of a cone-beam O-arm imaging system. J Xray Sci Technol 17(4):305–317PubMed
26.
go back to reference Zrinzo L, Foltynie T, Limousin P, Hariz M (2012) Image-verified deep brain stimulation reduces risk and cost with no apparent impact on efficacy. Mov Disord 27(12):1585–1586CrossRefPubMed Zrinzo L, Foltynie T, Limousin P, Hariz M (2012) Image-verified deep brain stimulation reduces risk and cost with no apparent impact on efficacy. Mov Disord 27(12):1585–1586CrossRefPubMed
27.
go back to reference Zrinzo L, Foltynie T, Limousin P, Hariz M (2012) Reducing hemorrhagic complications in functional neurosurgery: a large case series and systematic literature review. J Neurosurg 116:84–94CrossRefPubMed Zrinzo L, Foltynie T, Limousin P, Hariz M (2012) Reducing hemorrhagic complications in functional neurosurgery: a large case series and systematic literature review. J Neurosurg 116:84–94CrossRefPubMed
Metadata
Title
STN DBS for Parkinson’s disease: results from a series of ten consecutive patients implanted under general anaesthesia with intraoperative use of 3D fluoroscopy to control lead placement
Authors
Maxime Delavallée
Julien Delaunois
Jean Ruwet
Anne Jeanjean
Christian Raftopoulos
Publication date
01-09-2016
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 9/2016
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-016-2889-y

Other articles of this Issue 9/2016

Acta Neurochirurgica 9/2016 Go to the issue