01-10-2012 | Technical Note

Straight needle with fingertip support technique reduces exclusion time during bypass (in vitro, in vivo animal study): a technical note

Authors: András Csókay, Domonkos Imreh, Attila Papp, István Valálik

Published in: Acta Neurochirurgica | Issue 10/2012

Login to get access

Abstract

Background

The duration of exclusion time of recipient artery is an important factor in bypass surgery of cerebral revascularization. The longest period of exclusion is the suturing time. The fingertip support technique (first published in 2006) reduced the physiological tremor to speed up this extra-precise microsurgical procedure. The use of a straight needle proved to further decrease suturing time during the bypass procedure.

Methods

A straight micro needle was added to the fingertip support method for further reduction of exclusion time. A comparative study, measuring the duration of suturing time in vitro and in vivo for animal cases, was performed. This was a golden opportunity to examine how to simplify vascular transposition, using the fingertip support technique and straight needle.

Results

The average time of the bypass procedure by the novel considerations (fingertip support and straight needle) was significantly less than the average time by traditional microsurgical support.

Conclusion

This in vitro/in vivo animal study provides evidence of the reduction of the suturing time, and thus the exclusion time, by using the fingertip support technique with a straight needle in the bypass procedure.
Appendix
Available only for authorised users
Literature
1.
go back to reference Csókay A, Csókay G (2006) I., II., III fingertip support technique in microsurgery. Hungar Med J 40:1921–1922 Csókay A, Csókay G (2006) I., II., III fingertip support technique in microsurgery. Hungar Med J 40:1921–1922
2.
go back to reference Csókay A, Valálik I, Jobbágy Á (2009) Early experiences with a novel technique in the course of micro neurosurgery. Surg Neurol 71:469–472PubMedCrossRef Csókay A, Valálik I, Jobbágy Á (2009) Early experiences with a novel technique in the course of micro neurosurgery. Surg Neurol 71:469–472PubMedCrossRef
3.
go back to reference Ferguson RL, Jobe K (2004) A quiet hand for micro neurosurgery: twiddle your thumb. J Neurosurg 101:541–544PubMedCrossRef Ferguson RL, Jobe K (2004) A quiet hand for micro neurosurgery: twiddle your thumb. J Neurosurg 101:541–544PubMedCrossRef
4.
go back to reference Hartwell RC, Ferguson RL (1983) Physiologic tremor and microsurgery. Microsurgery 4:187–192CrossRef Hartwell RC, Ferguson RL (1983) Physiologic tremor and microsurgery. Microsurgery 4:187–192CrossRef
5.
go back to reference Hino A (2003) Training in microvascular surgery using a chicken wing artery. Neurosurgery 52(6):1495–1497PubMedCrossRef Hino A (2003) Training in microvascular surgery using a chicken wing artery. Neurosurgery 52(6):1495–1497PubMedCrossRef
6.
go back to reference Mohit A, Sekhar L, Natarajan S, Britz G, Ghodke B (2007) High-Flow Bypass in the management of Complex Intracranial Aneurysms Operative Microsurgery 60:105–123 Mohit A, Sekhar L, Natarajan S, Britz G, Ghodke B (2007) High-Flow Bypass in the management of Complex Intracranial Aneurysms Operative Microsurgery 60:105–123
7.
go back to reference Ovári A, Pataki G, Valálik I, Jobbágy A, Dommerich S, Pau HW, Csókay A (2010) Fingertip support technique and instrument support for reducing unintentional instrument movements in otology. Clin Otolaryngol 35:343–344PubMedCrossRef Ovári A, Pataki G, Valálik I, Jobbágy A, Dommerich S, Pau HW, Csókay A (2010) Fingertip support technique and instrument support for reducing unintentional instrument movements in otology. Clin Otolaryngol 35:343–344PubMedCrossRef
8.
go back to reference Pataki G, Csokay G, Csokay A (2009) Experiences with novel fingertip support micro-surgical technique in plastic and reconstructive surgery. Plast Reconstr Surg 124:692–693 Pataki G, Csokay G, Csokay A (2009) Experiences with novel fingertip support micro-surgical technique in plastic and reconstructive surgery. Plast Reconstr Surg 124:692–693
9.
go back to reference Tulleken CA, Verdaasdonk RM, Berendsen W, Mali WP (1993) Use of the excimer laser in high-flow bypass surgery of the brain. J Neurosurg 78:477–480PubMedCrossRef Tulleken CA, Verdaasdonk RM, Berendsen W, Mali WP (1993) Use of the excimer laser in high-flow bypass surgery of the brain. J Neurosurg 78:477–480PubMedCrossRef
10.
go back to reference Yonekawa Y, Frick R, Roth P, Taub E, Imhof HG (1999) Laboratory training in microsurgical techniques and microvascular anastomosis. Oper Tech Neurosurg 2:149–158CrossRef Yonekawa Y, Frick R, Roth P, Taub E, Imhof HG (1999) Laboratory training in microsurgical techniques and microvascular anastomosis. Oper Tech Neurosurg 2:149–158CrossRef
Metadata
Title
Straight needle with fingertip support technique reduces exclusion time during bypass (in vitro, in vivo animal study): a technical note
Authors
András Csókay
Domonkos Imreh
Attila Papp
István Valálik