Skip to main content
Top
Published in: Acta Neurochirurgica 12/2010

01-12-2010 | Clinical Article

Head positioning and risk of pneumocephalus, air embolism, and hemorrhage during subthalamic deep brain stimulation surgery

Authors: Jules M. Nazzaro, Kelly E. Lyons, Robyn A. Honea, Matthew S. Mayo, Galen Cook-Wiens, Amith Harsha, Jeffrey M. Burns, Rajesh Pahwa

Published in: Acta Neurochirurgica | Issue 12/2010

Login to get access

Abstract

Purpose

The objective of the present study was to evaluate the risk of pneumocephalus, venous air embolism (VAE), and intracranial hemorrhage in subthalamic nucleus (STN) deep brain stimulation (DBS) patients operated in the strict supine (head and body flat) position.

Methods

This was a retrospective review of clinical records and brain imaging of patients who underwent STN DBS between January 2007 and June 2009 at the University of Kansas Medical Center.

Results

A total of 61 patients underwent 114 lead implantations (53 staged bilateral and 8 unilateral). No case involved a transventricular route. Intracranial air volumes ranged from 0 to 7.02 cm3 (mean 0.98 ± 1.42 cm3). Pneumocephalus volumes were highly skewed with no air present after 44 (38.6%) lead implantations, >0 to 1 cm3 in 35 (30.7%), >2 to 3 cm3 in 17 (14.9%), and >3 cm3 (average 4.97 cm3) in 9 (7.9%). There was no incidence of clinically apparent VAE or symptomatic intracranial hemorrhage. There was no association between age, degree of atrophy, sagittal angle of surgical approach, number of microelectrode runs (MERs), distance of gyrus from inner skull bone at the entry point, or surgical side and pneumocephalus. However, the majority of lead implantations (100 leads; 88%) required only one MER and there were minimal measurable distances between entered gyrus and adjacent bone.

Conclusions

Our data suggest that strict supine positioning during STN DBS surgery results in minimal intracranial air and is not associated with VAE or symptomatic intracranial hemorrhage when the operative method described is used.
Literature
2.
go back to reference Benabid AL, Wallace B, Hoffmann D, Chabardes S, Grand S, LeBas JF (2008) Implantation of multiple electrodes and robotic techniques. In: Bakay RAE (ed) Movement disorder surgery. Thieme, New York, pp 126–139 Benabid AL, Wallace B, Hoffmann D, Chabardes S, Grand S, LeBas JF (2008) Implantation of multiple electrodes and robotic techniques. In: Bakay RAE (ed) Movement disorder surgery. Thieme, New York, pp 126–139
3.
go back to reference Burns JM, Cronk BB, Anderson HS, Donnelly JE, Thomas GP, Harsha A, Brooks WM, Swerdlow RH (2008) Cardiorespiratory fitness and brain atrophy in early Alzheimer disease. Neurology 71:210–216CrossRefPubMed Burns JM, Cronk BB, Anderson HS, Donnelly JE, Thomas GP, Harsha A, Brooks WM, Swerdlow RH (2008) Cardiorespiratory fitness and brain atrophy in early Alzheimer disease. Neurology 71:210–216CrossRefPubMed
4.
go back to reference Daniluk S, Davies KG, Novak P, Vu T, Nazzaro JM, Ellias SA (2009) Isolation of the brain-related factor of the error between intended and achieved position of deep brain stimulation electrodes implanted into the subthalamic nucleus for the treatment of Parkinson’s disease. Neurosurgery 64:374–382CrossRefPubMed Daniluk S, Davies KG, Novak P, Vu T, Nazzaro JM, Ellias SA (2009) Isolation of the brain-related factor of the error between intended and achieved position of deep brain stimulation electrodes implanted into the subthalamic nucleus for the treatment of Parkinson’s disease. Neurosurgery 64:374–382CrossRefPubMed
5.
go back to reference Deogaonkar A, Avitsian R, Henderson JM, Schubert A (2005) Venous air embolism during deep brain stimulation surgery in an awake supine patient. Stereotact Funct Neurosurg 83:32–35CrossRefPubMed Deogaonkar A, Avitsian R, Henderson JM, Schubert A (2005) Venous air embolism during deep brain stimulation surgery in an awake supine patient. Stereotact Funct Neurosurg 83:32–35CrossRefPubMed
6.
go back to reference Elias WJ, Fu KM, Frysinger RC (2007) Cortical and subcortical brain shift during stereotactic procedures. J Neurosurg 107:983–988CrossRefPubMed Elias WJ, Fu KM, Frysinger RC (2007) Cortical and subcortical brain shift during stereotactic procedures. J Neurosurg 107:983–988CrossRefPubMed
7.
go back to reference Eller JL, Burchiel KJ (2008) Deep brain stimulation for tremor. In: Bakay RAE (ed) Movement disorder surgery. Thieme, New York, pp 153–165 Eller JL, Burchiel KJ (2008) Deep brain stimulation for tremor. In: Bakay RAE (ed) Movement disorder surgery. Thieme, New York, pp 153–165
8.
go back to reference Goodman RR, Kim B, McClelland S III, Senatus PB, Winfield LM, Pullman SL, Yu Q, Ford B, McKhann GM (2006) Operative techniques and morbidity with subthalamic nucleus deep brain stimulation in 100 consecutive patients with advanced Parkinson’s disease. J Neurol Neurosurg Psychiatry 77:12–17CrossRefPubMed Goodman RR, Kim B, McClelland S III, Senatus PB, Winfield LM, Pullman SL, Yu Q, Ford B, McKhann GM (2006) Operative techniques and morbidity with subthalamic nucleus deep brain stimulation in 100 consecutive patients with advanced Parkinson’s disease. J Neurol Neurosurg Psychiatry 77:12–17CrossRefPubMed
9.
go back to reference Halpern CH, Danish SF, Baltuch GH, Jaggi JL (2008) Brain shift during deep brain stimulation surgery for Parkinson’s disease. Stereotact Funct Neurosurg 86:37–43CrossRefPubMed Halpern CH, Danish SF, Baltuch GH, Jaggi JL (2008) Brain shift during deep brain stimulation surgery for Parkinson’s disease. Stereotact Funct Neurosurg 86:37–43CrossRefPubMed
10.
go back to reference Henderson JM (2008) Frameless functional stereotactic approaches. In: Bakay RAE (ed) Movement disorder surgery. Thieme, New York, pp 140–152 Henderson JM (2008) Frameless functional stereotactic approaches. In: Bakay RAE (ed) Movement disorder surgery. Thieme, New York, pp 140–152
11.
go back to reference Honea RA, Thomas GP, Harsha A, Anderson HS, Donnelly JE, Brooks WM, Burns JM (2009) Cardiorespiratory fitness and preserved medial temporal lobe volume in Alzheimer disease. Alzheimer Dis Assoc Disord 23:188–197CrossRefPubMed Honea RA, Thomas GP, Harsha A, Anderson HS, Donnelly JE, Brooks WM, Burns JM (2009) Cardiorespiratory fitness and preserved medial temporal lobe volume in Alzheimer disease. Alzheimer Dis Assoc Disord 23:188–197CrossRefPubMed
12.
go back to reference Hooper AK, Okun MS, Foote KD, Haq IU, Fernandez HH, Hegland D, Robicsek SA (2009) Venous air embolism in deep brain stimulation. Stereotact Funct Neurosurg 87:25–30CrossRefPubMed Hooper AK, Okun MS, Foote KD, Haq IU, Fernandez HH, Hegland D, Robicsek SA (2009) Venous air embolism in deep brain stimulation. Stereotact Funct Neurosurg 87:25–30CrossRefPubMed
13.
go back to reference Hunsche S, Sauner D, Maarouf M, Lackner K, Sturm V, Treuer H (2007) Combined X-ray and magnetic resonance imaging facility: application to image-guided stereotactic and functional neurosurgery. Neurosurgery 60:352–360CrossRefPubMed Hunsche S, Sauner D, Maarouf M, Lackner K, Sturm V, Treuer H (2007) Combined X-ray and magnetic resonance imaging facility: application to image-guided stereotactic and functional neurosurgery. Neurosurgery 60:352–360CrossRefPubMed
14.
go back to reference Hunsche S, Sauner D, Maarouf M, Poggenborg J, Lackner K, Sturm V, Treuer H (2009) Intraoperative X-ray detection and MRI-based quantification of brain shift effects subsequent to implantation of the first electrode in bilateral implantation of deep brain stimulation electrodes. Stereotact Funct Neurosurg 87:322–329CrossRefPubMed Hunsche S, Sauner D, Maarouf M, Poggenborg J, Lackner K, Sturm V, Treuer H (2009) Intraoperative X-ray detection and MRI-based quantification of brain shift effects subsequent to implantation of the first electrode in bilateral implantation of deep brain stimulation electrodes. Stereotact Funct Neurosurg 87:322–329CrossRefPubMed
15.
go back to reference Kenney C, Simpson R, Hunter C, Ondo W, Almaguer M, Davidson A, Jankovic J (2007) Short-term and long-term safety of deep brain stimulation in the treatment of movement disorders. J Neurosurg 106:621–625CrossRefPubMed Kenney C, Simpson R, Hunter C, Ondo W, Almaguer M, Davidson A, Jankovic J (2007) Short-term and long-term safety of deep brain stimulation in the treatment of movement disorders. J Neurosurg 106:621–625CrossRefPubMed
16.
go back to reference Khan MF, Mewes K, Gross RE, Skrinjar O (2008) Assessment of brain shift related to deep brain stimulation surgery. Stereotact Funct Neurosurg 86:44–53CrossRefPubMed Khan MF, Mewes K, Gross RE, Skrinjar O (2008) Assessment of brain shift related to deep brain stimulation surgery. Stereotact Funct Neurosurg 86:44–53CrossRefPubMed
17.
go back to reference Miyagi Y, Shima F, Sasaki T (2007) Brain shift: an error factor during implantation of deep brain stimulation electrodes. J Neurosurg 107:989–997CrossRefPubMed Miyagi Y, Shima F, Sasaki T (2007) Brain shift: an error factor during implantation of deep brain stimulation electrodes. J Neurosurg 107:989–997CrossRefPubMed
18.
go back to reference Moitra V, Permut TA, Penn RM, Roth S (2004) Venous air embolism in an awake patient undergoing placement of deep brain stimulators. J Neurosurg Anesthesiol 16:321–322CrossRefPubMed Moitra V, Permut TA, Penn RM, Roth S (2004) Venous air embolism in an awake patient undergoing placement of deep brain stimulators. J Neurosurg Anesthesiol 16:321–322CrossRefPubMed
19.
go back to reference Novak P, Klemp JA, Ridings LW, Lyons KE, Pahwa R, Nazzaro JM (2009) Effect of deep brain stimulation of the subthalamic nucleus upon the contralateral subthalamic nucleus in Parkinson disease. Neurosci Lett 463:12–16CrossRefPubMed Novak P, Klemp JA, Ridings LW, Lyons KE, Pahwa R, Nazzaro JM (2009) Effect of deep brain stimulation of the subthalamic nucleus upon the contralateral subthalamic nucleus in Parkinson disease. Neurosci Lett 463:12–16CrossRefPubMed
20.
go back to reference Rohlfing T, Maurer CR Jr, Dean D, Maciunas RJ (2003) Effect of changing patient position from supine to prone on the accuracy of a Brown–Roberts–Wells stereotactic head frame system. Neurosurgery 52:610–618CrossRefPubMed Rohlfing T, Maurer CR Jr, Dean D, Maciunas RJ (2003) Effect of changing patient position from supine to prone on the accuracy of a Brown–Roberts–Wells stereotactic head frame system. Neurosurgery 52:610–618CrossRefPubMed
21.
go back to reference Sansur CA, Frysinger RC, Pouratian N, Fu KM, Bittl M, Oskouian RJ, Laws ER, Elias WJ (2007) Incidence of symptomatic hemorrhage after stereotactic electrode placement. J Neurosurg 107:998–1003CrossRefPubMed Sansur CA, Frysinger RC, Pouratian N, Fu KM, Bittl M, Oskouian RJ, Laws ER, Elias WJ (2007) Incidence of symptomatic hemorrhage after stereotactic electrode placement. J Neurosurg 107:998–1003CrossRefPubMed
22.
go back to reference Seijo FJ, Varez-Vega MA, Gutierrez JC, Fdez-Glez F, Lozano B (2007) Complications in subthalamic nucleus stimulation surgery for treatment of Parkinson’s disease. Review of 272 procedures. Acta Neurochir (Wien) 149:867–875CrossRef Seijo FJ, Varez-Vega MA, Gutierrez JC, Fdez-Glez F, Lozano B (2007) Complications in subthalamic nucleus stimulation surgery for treatment of Parkinson’s disease. Review of 272 procedures. Acta Neurochir (Wien) 149:867–875CrossRef
23.
go back to reference Sierens D, Kutz S, Pilitsis JG, Bakay AE (2008) Stereotactic surgery with microelectrode recordings. In: Bakay RAE (ed) Movement disorders surgery. Thieme, New York, pp 83–114 Sierens D, Kutz S, Pilitsis JG, Bakay AE (2008) Stereotactic surgery with microelectrode recordings. In: Bakay RAE (ed) Movement disorders surgery. Thieme, New York, pp 83–114
24.
go back to reference Suarez S, Ornaque I, Fabregas N, Valero R, Carrero E (1999) Venous air embolism during Parkinson surgery in patients with spontaneous ventilation. Anesth Analg 88:793–794CrossRefPubMed Suarez S, Ornaque I, Fabregas N, Valero R, Carrero E (1999) Venous air embolism during Parkinson surgery in patients with spontaneous ventilation. Anesth Analg 88:793–794CrossRefPubMed
25.
go back to reference Temel Y, Willbrink P, Duits A, Boon P, Tromp S, Ackermans L, van Kranen-Mastenbroek V, Weber W, Visser-Vandewalle V (2007) Single electrode and multiple electrode guided electrical stimulation of the subthalamic nucleus in advanced Parkinson’s disease. Neurosurgery 61:ONS346–ONS357CrossRef Temel Y, Willbrink P, Duits A, Boon P, Tromp S, Ackermans L, van Kranen-Mastenbroek V, Weber W, Visser-Vandewalle V (2007) Single electrode and multiple electrode guided electrical stimulation of the subthalamic nucleus in advanced Parkinson’s disease. Neurosurgery 61:ONS346–ONS357CrossRef
26.
go back to reference Videnovic A, Metman LV (2008) Deep brain stimulation for Parkinson’s disease: prevalence of adverse events and need for standardized reporting. Mov Disord 23:343–349CrossRefPubMed Videnovic A, Metman LV (2008) Deep brain stimulation for Parkinson’s disease: prevalence of adverse events and need for standardized reporting. Mov Disord 23:343–349CrossRefPubMed
27.
go back to reference Voges J, Waerzeggers Y, Maarouf M, Lehrke R, Koulousakis A, Lenartz D, Sturm V (2006) Deep-brain stimulation: long-term analysis of complications caused by hardware and surgery—experiences from a single centre. J Neurol Neurosurg Psychiatry 77:868–872CrossRefPubMed Voges J, Waerzeggers Y, Maarouf M, Lehrke R, Koulousakis A, Lenartz D, Sturm V (2006) Deep-brain stimulation: long-term analysis of complications caused by hardware and surgery—experiences from a single centre. J Neurol Neurosurg Psychiatry 77:868–872CrossRefPubMed
Metadata
Title
Head positioning and risk of pneumocephalus, air embolism, and hemorrhage during subthalamic deep brain stimulation surgery
Authors
Jules M. Nazzaro
Kelly E. Lyons
Robyn A. Honea
Matthew S. Mayo
Galen Cook-Wiens
Amith Harsha
Jeffrey M. Burns
Rajesh Pahwa
Publication date
01-12-2010
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 12/2010
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-010-0776-5

Other articles of this Issue 12/2010

Acta Neurochirurgica 12/2010 Go to the issue