Skip to main content
Top
Published in: Acta Neurochirurgica 3/2010

01-03-2010 | Clinical Article

Influences of stents on the outcome of coil embolized intracranial aneurysms: comparison between a stent-remodeled and non-remodeled treatment

Authors: Dong Joon Kim, Sang Hyun Suh, Jae Whan Lee, Byung Moon Kim, Jae Wook Lee, Seung Kon Huh, Dong Ik Kim

Published in: Acta Neurochirurgica | Issue 3/2010

Login to get access

Abstract

Purpose

The influences of a stent on the outcome of embolized aneurysms are not well known. The purpose of this study is to assess and compare the angiographic follow-up (FU) results of stent-remodeled (StR) and non-remodeled (nonR) coil embolization of intracranial aneurysms.

Methods

Thirty-seven StR patients with FU digital subtraction angiography (DSA) were matched with 37 nonR patients according to presentation (ruptured or unruptured), location of the aneurysm (sidewall or bifurcation), initial sac occlusion (complete/near complete or incomplete/failure), and the sac size (largest diameter/less than 2 mm difference). The baseline clinical and aneurysm characteristics, initial/FU treatment success rates, and FU DSA findings between the StR and nonR groups with regard to the morphologic features (size and location) of the aneurysms were assessed and compared.

Results

The StR group showed more frequent progressive thrombosis compared to the nonR group (56.8 vs. 27.0%; p < 0.05). These differences were more prominent for small aneurysms (70 vs. 25%; p < 0.05). Small aneurysms showed a lower rate of FU recanalization in the StR group compared to the nonR group (0 vs. 25%; p < 0.05). Sidewall aneurysms also showed a higher rate of progressive thrombosis in the StR group (61.1 vs. 27.8%; p < 0.05).

Conclusions

Coil embolization is an effective treatment method for intracranial aneurysms, however, changes on follow-up may affect the long-term outcome. Stent remodeling may aid in preserving and enhancing the treatment durability especially in small aneurysms.
Literature
1.
go back to reference Akpek S, Arat A, Morsi H, Klucznick RP, Strother CM, Mawad ME (2005) Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol 26:1223–1231PubMed Akpek S, Arat A, Morsi H, Klucznick RP, Strother CM, Mawad ME (2005) Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol 26:1223–1231PubMed
2.
go back to reference Benitez RP, Silva MT, Klem J, Veznedaroglu E, Rosenwasser RH (2004) Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery 54:1359–1367 discussion 1368CrossRefPubMed Benitez RP, Silva MT, Klem J, Veznedaroglu E, Rosenwasser RH (2004) Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery 54:1359–1367 discussion 1368CrossRefPubMed
3.
go back to reference Cloft HJ (2006) HydroCoil for Endovascular Aneurysm Occlusion (HEAL) study: periprocedural results. AJNR Am J Neuroradiol 27:289–292PubMed Cloft HJ (2006) HydroCoil for Endovascular Aneurysm Occlusion (HEAL) study: periprocedural results. AJNR Am J Neuroradiol 27:289–292PubMed
4.
go back to reference Fiorella D, Albuquerque FC, Deshmukh VR, McDougall CG (2005) Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3–6-mo) follow-up. Neurosurgery 56:1191–1201 discussion 1201–1192CrossRefPubMed Fiorella D, Albuquerque FC, Deshmukh VR, McDougall CG (2005) Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3–6-mo) follow-up. Neurosurgery 56:1191–1201 discussion 1201–1192CrossRefPubMed
5.
go back to reference Fiorella D, Albuquerque FC, Deshmukh VR, Woo HH, Rasmussen PA, Masaryk TJ, McDougall CG (2006) Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms. Neurosurgery 59:291–300 discussion 291–300CrossRefPubMed Fiorella D, Albuquerque FC, Deshmukh VR, Woo HH, Rasmussen PA, Masaryk TJ, McDougall CG (2006) Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms. Neurosurgery 59:291–300 discussion 291–300CrossRefPubMed
6.
go back to reference Fiorella D, Albuquerque FC, Han P, McDougall CG (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–16 discussion 16–17CrossRefPubMed Fiorella D, Albuquerque FC, Han P, McDougall CG (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–16 discussion 16–17CrossRefPubMed
7.
go back to reference Fiorella D, Woo HH, Albuquerque FC, Nelson PK (2008) Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the pipeline embolization device. Neurosurgery 62:1115–1120 discussion 1120–1111CrossRefPubMed Fiorella D, Woo HH, Albuquerque FC, Nelson PK (2008) Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the pipeline embolization device. Neurosurgery 62:1115–1120 discussion 1120–1111CrossRefPubMed
8.
go back to reference Geremia G, Brack T, Brennecke L, Haklin M, Falter R (2000) Occlusion of experimentally created fusiform aneurysms with porous metallic stents. AJNR Am J Neuroradiol 21:739–745PubMed Geremia G, Brack T, Brennecke L, Haklin M, Falter R (2000) Occlusion of experimentally created fusiform aneurysms with porous metallic stents. AJNR Am J Neuroradiol 21:739–745PubMed
9.
go back to reference Hoi Y, Meng H, Woodward SH, Bendok BR, Hanel RA, Guterman LR, Hopkins LN (2004) Effects of arterial geometry on aneurysm growth: three-dimensional computational fluid dynamics study. J Neurosurg 101:676–681CrossRefPubMed Hoi Y, Meng H, Woodward SH, Bendok BR, Hanel RA, Guterman LR, Hopkins LN (2004) Effects of arterial geometry on aneurysm growth: three-dimensional computational fluid dynamics study. J Neurosurg 101:676–681CrossRefPubMed
10.
go back to reference Kwon OK, Kim SH, Oh CW, Han MH, Kang HS, Kwon BJ, Kim JH, Han DH (2006) Embolization of wide-necked aneurysms with using three or more microcatheters. Acta Neurochir (Wien) 148:1139–1145CrossRef Kwon OK, Kim SH, Oh CW, Han MH, Kang HS, Kwon BJ, Kim JH, Han DH (2006) Embolization of wide-necked aneurysms with using three or more microcatheters. Acta Neurochir (Wien) 148:1139–1145CrossRef
11.
go back to reference Lee YJ, Kim DJ, Suh SH, Lee SK, Kim J, Kim DI (2005) Stent-assisted coil embolization of intracranial wide-necked aneurysms. Neuroradiology 47:680–689CrossRefPubMed Lee YJ, Kim DJ, Suh SH, Lee SK, Kim J, Kim DI (2005) Stent-assisted coil embolization of intracranial wide-necked aneurysms. Neuroradiology 47:680–689CrossRefPubMed
12.
go back to reference Lehoux S, Tronc F, Tedgui A (2002) Mechanisms of blood flow-induced vascular enlargement. Biorheology 39:319–324PubMed Lehoux S, Tronc F, Tedgui A (2002) Mechanisms of blood flow-induced vascular enlargement. Biorheology 39:319–324PubMed
13.
go back to reference Lieber BB, Gounis MJ (2002) The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms. Neurol Res 24(Suppl 1):S33–S42CrossRefPubMed Lieber BB, Gounis MJ (2002) The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms. Neurol Res 24(Suppl 1):S33–S42CrossRefPubMed
14.
go back to reference Lieber BB, Livescu V, Hopkins LN, Wakhloo AK (2002) Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow. Ann Biomed Eng 30:768–777CrossRefPubMed Lieber BB, Livescu V, Hopkins LN, Wakhloo AK (2002) Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow. Ann Biomed Eng 30:768–777CrossRefPubMed
15.
go back to reference Lieber BB, Stancampiano AP, Wakhloo AK (1997) Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity. Ann Biomed Eng 25:460–469CrossRefPubMed Lieber BB, Stancampiano AP, Wakhloo AK (1997) Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity. Ann Biomed Eng 25:460–469CrossRefPubMed
16.
go back to reference Lopes D, Sani S (2005) Histological postmortem study of an internal carotid artery aneurysm treated with the Neuroform stent. Neurosurgery 56:E416 discussion E416CrossRefPubMed Lopes D, Sani S (2005) Histological postmortem study of an internal carotid artery aneurysm treated with the Neuroform stent. Neurosurgery 56:E416 discussion E416CrossRefPubMed
17.
go back to reference Meng H, Wang Z, Kim M, Ecker RD, Hopkins LN (2006) Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting. AJNR Am J Neuroradiol 27:1861–1865PubMed Meng H, Wang Z, Kim M, Ecker RD, Hopkins LN (2006) Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting. AJNR Am J Neuroradiol 27:1861–1865PubMed
18.
go back to reference Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J, Holman R (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1267–1274CrossRefPubMed Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J, Holman R (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1267–1274CrossRefPubMed
19.
go back to reference Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases. J Neuroradiol 24:30–44PubMed Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases. J Neuroradiol 24:30–44PubMed
20.
go back to reference Nguyen TN, Hoh BL, Amin-Hanjani S, Pryor JC, Ogilvy CS (2007) Comparison of ruptured vs unruptured aneurysms in recanalization after coil embolization. Surg Neurol 68:19–23CrossRefPubMed Nguyen TN, Hoh BL, Amin-Hanjani S, Pryor JC, Ogilvy CS (2007) Comparison of ruptured vs unruptured aneurysms in recanalization after coil embolization. Surg Neurol 68:19–23CrossRefPubMed
21.
go back to reference Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambert A, Lamoureux J, Chagnon M, Roy D (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403CrossRefPubMed Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambert A, Lamoureux J, Chagnon M, Roy D (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403CrossRefPubMed
22.
go back to reference Sluzewski M, van Rooij WJ, Rinkel GJ, Wijnalda D (2003) Endovascular treatment of ruptured intracranial aneurysms with detachable coils: long-term clinical and serial angiographic results. Radiology 227:720–724CrossRefPubMed Sluzewski M, van Rooij WJ, Rinkel GJ, Wijnalda D (2003) Endovascular treatment of ruptured intracranial aneurysms with detachable coils: long-term clinical and serial angiographic results. Radiology 227:720–724CrossRefPubMed
23.
go back to reference Steiger HJ (1990) Pathophysiology of development and rupture of cerebral aneurysms. Acta Neurochir Suppl (Wien) 48:1–57 Steiger HJ (1990) Pathophysiology of development and rupture of cerebral aneurysms. Acta Neurochir Suppl (Wien) 48:1–57
24.
go back to reference Szikora I, Berentei Z, Kulcsar Z, Barath K, Berez A, Bose A, Nyary I (2006) Endovascular treatment of intracranial aneurysms with parent vessel reconstruction using balloon and self expandable stents. Acta Neurochir (Wien) 148:711–723 discussion 723CrossRef Szikora I, Berentei Z, Kulcsar Z, Barath K, Berez A, Bose A, Nyary I (2006) Endovascular treatment of intracranial aneurysms with parent vessel reconstruction using balloon and self expandable stents. Acta Neurochir (Wien) 148:711–723 discussion 723CrossRef
25.
go back to reference Tumialan LM, Zhang YJ, Cawley CM, Dion JE, Tong FC, Barrow DL (2008) Intracranial hemorrhage associated with stent-assisted coil embolization of cerebral aneurysms: a cautionary report. J Neurosurg 108:1122–1129CrossRefPubMed Tumialan LM, Zhang YJ, Cawley CM, Dion JE, Tong FC, Barrow DL (2008) Intracranial hemorrhage associated with stent-assisted coil embolization of cerebral aneurysms: a cautionary report. J Neurosurg 108:1122–1129CrossRefPubMed
26.
go back to reference Vallee JN, Pierot L, Mont'alverne F, Turjman F, Bonafe A, Bracard S, Lo D, Crozier S, Duffau H, Barragan-Campos HM, Jean B, Guillevin R, Chiras J (2005) Unruptured intracranial aneurysms treated by three-dimensional coil embolization: evaluation of the postoperative aneurysm occlusion volume. Neuroradiology 47:438–445CrossRefPubMed Vallee JN, Pierot L, Mont'alverne F, Turjman F, Bonafe A, Bracard S, Lo D, Crozier S, Duffau H, Barragan-Campos HM, Jean B, Guillevin R, Chiras J (2005) Unruptured intracranial aneurysms treated by three-dimensional coil embolization: evaluation of the postoperative aneurysm occlusion volume. Neuroradiology 47:438–445CrossRefPubMed
27.
go back to reference Wakhloo A, Lieber BB, Sandhu JS, Gounis M (2004) Flow dynamics in aneurysms. In: Le Roux PD, Winn HR, Newell DW (eds) Management of cerebral aneurysms. Saunders, Philadelphia, pp 99–120 Wakhloo A, Lieber BB, Sandhu JS, Gounis M (2004) Flow dynamics in aneurysms. In: Le Roux PD, Winn HR, Newell DW (eds) Management of cerebral aneurysms. Saunders, Philadelphia, pp 99–120
28.
go back to reference Wanke I, Doerfler A, Schoch B, Stolke D, Forsting M (2003) Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience. AJNR Am J Neuroradiol 24:1192–1199PubMed Wanke I, Doerfler A, Schoch B, Stolke D, Forsting M (2003) Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience. AJNR Am J Neuroradiol 24:1192–1199PubMed
29.
go back to reference Weber W, Bendszus M, Kis B, Boulanger T, Solymosi L, Kuhne D (2007) A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms. Neuroradiology 49:555–561CrossRefPubMed Weber W, Bendszus M, Kis B, Boulanger T, Solymosi L, Kuhne D (2007) A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms. Neuroradiology 49:555–561CrossRefPubMed
Metadata
Title
Influences of stents on the outcome of coil embolized intracranial aneurysms: comparison between a stent-remodeled and non-remodeled treatment
Authors
Dong Joon Kim
Sang Hyun Suh
Jae Whan Lee
Byung Moon Kim
Jae Wook Lee
Seung Kon Huh
Dong Ik Kim
Publication date
01-03-2010
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 3/2010
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-009-0522-z

Other articles of this Issue 3/2010

Acta Neurochirurgica 3/2010 Go to the issue