Skip to main content
Top
Published in: Surgery Today 9/2014

01-09-2014 | Case Report

A new device for MRI-guided surgical excision: report of a case

Authors: Yuko Tsunoda, Jun-ichi Sanuki, Nobuhito Katayama, Eisuke Fukuma, Kazue Hoshi

Published in: Surgery Today | Issue 9/2014

Login to get access

Abstract

A 37-year-old female was indicated to have a non-mass lesion in her left breast on ultrasonography (US) and visited our outpatient clinic. Mammography showed no findings of masses or microcalcification. Dynamic magnetic resonance imaging (MRI) showed a segmental enhanced lesion consisting of nodular and ring enhancement. A US-assisted vacuumed needle biopsy was performed, and the histological findings revealed sclerosing adenosis and apocrine metaplasia. After 1 year of follow-up, the MRI findings suggested both a benign lesion and ductal carcinoma in situ, and surgical excision was performed. We used a new device to evaluate the surgical margin on MRI. The non-mass lesion was excised according to the device-guided margin under local anesthesia. The histological findings revealed the features of mastopathy. Following excision, MRI showed no residual non-mass lesions, and the shape of the patient’s left breast was maintained.
Literature
1.
go back to reference Abe H, Mori T, Umeda T, Tanaka M, Kawai Y, Shimizu T, et al. Indocyanine green fluorescence imaging system for sentinel lymph node biopsies in early breast cancer patients. Surg Today. 2011;41:197–202.PubMedCrossRef Abe H, Mori T, Umeda T, Tanaka M, Kawai Y, Shimizu T, et al. Indocyanine green fluorescence imaging system for sentinel lymph node biopsies in early breast cancer patients. Surg Today. 2011;41:197–202.PubMedCrossRef
2.
go back to reference Orel SG, Schnall MD. MR imaging of the breast for the detection, diagnosis, and staging of breast cancer. Radiology. 2001;220:13–30.PubMedCrossRef Orel SG, Schnall MD. MR imaging of the breast for the detection, diagnosis, and staging of breast cancer. Radiology. 2001;220:13–30.PubMedCrossRef
3.
go back to reference Daniel BL, Birdwell RL, Butts K, Nowels KW, Ikeda DM, Heiss SG, et al. Freehand MRI-guided large-gauge core needle biopsy: a new minimally invasive technique for diagnosis of enhancing breast lesions. J Magn Reson Imaging. 2001;13:896–902.PubMedCrossRef Daniel BL, Birdwell RL, Butts K, Nowels KW, Ikeda DM, Heiss SG, et al. Freehand MRI-guided large-gauge core needle biopsy: a new minimally invasive technique for diagnosis of enhancing breast lesions. J Magn Reson Imaging. 2001;13:896–902.PubMedCrossRef
4.
go back to reference Heywang-Kobrunner SH, Heinig A, Pickuth D, Alberich T, Spielmann RP. Interventional MRI of the breast: lesion localization and biopsy. Eur Radiol. 2000;10:36–45.PubMedCrossRef Heywang-Kobrunner SH, Heinig A, Pickuth D, Alberich T, Spielmann RP. Interventional MRI of the breast: lesion localization and biopsy. Eur Radiol. 2000;10:36–45.PubMedCrossRef
5.
go back to reference Tsushimi T, Enoki T, Takemoto Y, Harada E, Hayashi M, Furuya T, et al. Adenoma of the nipple, focusing on the contrast-enhanced magnetic resonance imaging findings: report of a case. Surg Today. 2011;41:1138–41.PubMedCrossRef Tsushimi T, Enoki T, Takemoto Y, Harada E, Hayashi M, Furuya T, et al. Adenoma of the nipple, focusing on the contrast-enhanced magnetic resonance imaging findings: report of a case. Surg Today. 2011;41:1138–41.PubMedCrossRef
6.
go back to reference Sanuki J, Katayama N, Tsunoda Y, Katoh M, Kaisaki S, Kitayama J. Breast-conserving surgery using 3 dimension subcutaneous markers: report of a case. Operation (In Japanese). 2011;65:1815–9. Sanuki J, Katayama N, Tsunoda Y, Katoh M, Kaisaki S, Kitayama J. Breast-conserving surgery using 3 dimension subcutaneous markers: report of a case. Operation (In Japanese). 2011;65:1815–9.
7.
go back to reference Genson CC, Blane CE, Helvie MA, Waits SA, Chenevert TC. Effect on breast MRI of artifacts caused by metallic tissue marker clips. AJR. 2007;188:372–6.PubMedCrossRef Genson CC, Blane CE, Helvie MA, Waits SA, Chenevert TC. Effect on breast MRI of artifacts caused by metallic tissue marker clips. AJR. 2007;188:372–6.PubMedCrossRef
8.
go back to reference Lehman CD, Eby PR, Chen X, Dee KE, Thursten B, McCloskey J. MR Imaging-guided breast biopsy using a coaxial technique with a 14-gauge stainless steel core biopsy needle and a titanium sheath. AJR. 2003;181:183–5.PubMedCrossRef Lehman CD, Eby PR, Chen X, Dee KE, Thursten B, McCloskey J. MR Imaging-guided breast biopsy using a coaxial technique with a 14-gauge stainless steel core biopsy needle and a titanium sheath. AJR. 2003;181:183–5.PubMedCrossRef
9.
go back to reference DiPiro PJ. Disappearance of a localizing clip placed after stereotactic core biopsy of the breast (letter). AJR. 1999;173:1134.PubMedCrossRef DiPiro PJ. Disappearance of a localizing clip placed after stereotactic core biopsy of the breast (letter). AJR. 1999;173:1134.PubMedCrossRef
10.
go back to reference Philpotts LE, Lee CH. Clip migration after 11-gauge vacuum-assisted stereotactic biopsy: case report. Radiology. 2002;222:794–6.PubMedCrossRef Philpotts LE, Lee CH. Clip migration after 11-gauge vacuum-assisted stereotactic biopsy: case report. Radiology. 2002;222:794–6.PubMedCrossRef
11.
go back to reference Davis PS, Wechsler RJ, Feig SA, March DE. Migration of breast biopsy localization wire. AJR. 1988;150:787–8.PubMedCrossRef Davis PS, Wechsler RJ, Feig SA, March DE. Migration of breast biopsy localization wire. AJR. 1988;150:787–8.PubMedCrossRef
12.
go back to reference Owen AW, Kumar EN. Migration of localizing wires used in guided biopsy of the breast. Clin Radiol. 1991;43:251.PubMedCrossRef Owen AW, Kumar EN. Migration of localizing wires used in guided biopsy of the breast. Clin Radiol. 1991;43:251.PubMedCrossRef
13.
go back to reference Sakakibara M, Nagashima T, Sangai T, Nakamura R, Fujimoto H, Arai M, et al. Breast-conserving surgery using projection and reproduction techniques of surgical-position breast MRI in patients with ductal carcinoma in situ of the breast. J Am Coll Surg. 2008;207:62–8.PubMedCrossRef Sakakibara M, Nagashima T, Sangai T, Nakamura R, Fujimoto H, Arai M, et al. Breast-conserving surgery using projection and reproduction techniques of surgical-position breast MRI in patients with ductal carcinoma in situ of the breast. J Am Coll Surg. 2008;207:62–8.PubMedCrossRef
Metadata
Title
A new device for MRI-guided surgical excision: report of a case
Authors
Yuko Tsunoda
Jun-ichi Sanuki
Nobuhito Katayama
Eisuke Fukuma
Kazue Hoshi
Publication date
01-09-2014
Publisher
Springer Japan
Published in
Surgery Today / Issue 9/2014
Print ISSN: 0941-1291
Electronic ISSN: 1436-2813
DOI
https://doi.org/10.1007/s00595-013-0621-6

Other articles of this Issue 9/2014

Surgery Today 9/2014 Go to the issue