Excerpt

The article by Yuan et al. [1] in your journal brings up a very important, but sparsely talked about issue encountered while doing screw fixation of femoral neck fractures. We ourselves have faced the problem of in-out-in screws in our practice over the years [2]. This letter intends to present a few insights into how we have analyzed this problem. …
Literature
1.
go back to reference Yuan BJ, Shamaa MT, Aibinder WR, Parry JA, Cross WW, Barlow JD et al (2020) High incidence of “in–out–in” posterosuperior screws after cannulated screw fixation of femoral neck fractures. Eur J Orthop Surg Traumatol 30(8):1417–1420CrossRef Yuan BJ, Shamaa MT, Aibinder WR, Parry JA, Cross WW, Barlow JD et al (2020) High incidence of “in–out–in” posterosuperior screws after cannulated screw fixation of femoral neck fractures. Eur J Orthop Surg Traumatol 30(8):1417–1420CrossRef
2.
go back to reference Trikha V, Kumar A, Mittal S, Passey J, Chouhan D, Dubey S (2020) Risk of bony violation with standard triple screw configurations for fixation of femoral neck fractures: a preliminary computed tomography based analysis. J Clin Orthop Trauma 1(11):S546–S552CrossRef Trikha V, Kumar A, Mittal S, Passey J, Chouhan D, Dubey S (2020) Risk of bony violation with standard triple screw configurations for fixation of femoral neck fractures: a preliminary computed tomography based analysis. J Clin Orthop Trauma 1(11):S546–S552CrossRef
3.
go back to reference Estrada LS, Volgas DA, Stannard JP, Alonso JE (2002) Fixation failure in femoral neck fractures. Clin Orthop Relat Res 399:110–118CrossRef Estrada LS, Volgas DA, Stannard JP, Alonso JE (2002) Fixation failure in femoral neck fractures. Clin Orthop Relat Res 399:110–118CrossRef
4.
go back to reference Power J, Loveridge N, Kröger H, Parker M, Reeve J (2018) Femoral neck cortical bone in female and male hip fracture cases: differential contrasts in cortical width and sub-periosteal porosity in 112 cases and controls. Bone 1(114):81–89CrossRef Power J, Loveridge N, Kröger H, Parker M, Reeve J (2018) Femoral neck cortical bone in female and male hip fracture cases: differential contrasts in cortical width and sub-periosteal porosity in 112 cases and controls. Bone 1(114):81–89CrossRef
5.
go back to reference Mittal R, Banerjee S (2012) Proximal femoral fractures: principles of management and review of literature. J Clin Orthop Trauma 3:15–23CrossRef Mittal R, Banerjee S (2012) Proximal femoral fractures: principles of management and review of literature. J Clin Orthop Trauma 3:15–23CrossRef
Metadata
Title
In-out-in screws in femoral neck fractures: Can they be avoided?
Authors
Pulak Vatsya
Samarth Mittal
Buddhadev Chowdhury
Vivek Trikha
Publication date
01-01-2022
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 1/2022
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-021-02910-8

Other articles of this Issue 1/2022

European Journal of Orthopaedic Surgery & Traumatology 1/2022 Go to the issue