Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 4/2019

01-05-2019 | Original Article • KNEE - ARTHROPLASTY

Noninvasive navigated assessment of the lower limb axis prior to knee arthroplasty: a feasibility study

Authors: Jean-Yves Jenny, Gauthier Dillmann, Vincent Gisonni, Henri Favreau

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 4/2019

Login to get access

Abstract

The purpose of the study was to assess accuracy and repeatability of a noninvasive navigated (NIN) measurement of the lower limb axes by comparison with the conventional, invasive navigated (IN) technique. The tested hypothesis was that NIN measure will significantly differ from IN measure when performed on a supine patient under general anesthesia just prior to knee arthroplasty. The accuracy study involved 20 cases. The following measures were performed with both systems: maximal extension angle, coronal mechanical femoro-tibial angle at the previously assessed maximal extension angle, coronal mechanical femoro-tibial angle at 30° of knee flexion. NIN and IN measures were compared with the appropriate statistical tests. The repeatability study involved 14 cases. The same measures were performed with the NIN system twice by two independent observers. The intra- and inter-observer variability was assessed by the calculation of the intra-class correlation coefficient. After correction for the systematic biases, the differences between the two systems were not significant. A good correlation, a good coherence and an excellent agreement between NIN and IN measures of maximal extension angle and coronal femoro-tibial mechanical angle at maximal extension. But measures at 30° of flexion were inconsistent. The NIN system can be considered as an accurate and precise tool for the assessment of the knee extension angle and the coronal deformation at maximal extension prior to knee arthroplasty. But this system is less accurate and less repeatable when measuring coronal femoro-tibial mechanical angle at 30° of flexion and should not be used for this purpose.
Literature
1.
go back to reference Brouwer GM, van Tol AW, Bergink AP, Belo JN, Bernsen RM, Reijman M, Pols HA, Bierma-Zeinstra SM (2007) Association between valgus and varus alignment and the development and progression of radiographic osteoarthritis of the knee. Arthritis Rheum 56:1204–1211CrossRefPubMed Brouwer GM, van Tol AW, Bergink AP, Belo JN, Bernsen RM, Reijman M, Pols HA, Bierma-Zeinstra SM (2007) Association between valgus and varus alignment and the development and progression of radiographic osteoarthritis of the knee. Arthritis Rheum 56:1204–1211CrossRefPubMed
2.
go back to reference Brinkman JM, Lobenhoffer P, Agneskirchner JD, Staubli AE, Wymenga AB, van Heerwaarden RJ (2008) Osteotomies around the knee: patient selection, stability of fixation and bone healing in high tibial osteotomies. J Bone Joint Surg Br 90:1548–1557CrossRefPubMed Brinkman JM, Lobenhoffer P, Agneskirchner JD, Staubli AE, Wymenga AB, van Heerwaarden RJ (2008) Osteotomies around the knee: patient selection, stability of fixation and bone healing in high tibial osteotomies. J Bone Joint Surg Br 90:1548–1557CrossRefPubMed
3.
go back to reference Zahn RK, Fussi J, von Roth P, Perka CF, Hommel H (2016) Postoperative increased loading leads to an alteration in the radiological mechanical axis after total knee arthroplasty. J Arthroplasty 31:1803–1807CrossRefPubMed Zahn RK, Fussi J, von Roth P, Perka CF, Hommel H (2016) Postoperative increased loading leads to an alteration in the radiological mechanical axis after total knee arthroplasty. J Arthroplasty 31:1803–1807CrossRefPubMed
4.
go back to reference Boonen B, Kerens B, Schotanus MG, Emans P, Jong B, Kort NP (2016) Inter-observer reliability of measurements performed on digital long-leg standing radiographs and assessment of validity compared to 3D CT-scan. Knee 23:20–24CrossRefPubMed Boonen B, Kerens B, Schotanus MG, Emans P, Jong B, Kort NP (2016) Inter-observer reliability of measurements performed on digital long-leg standing radiographs and assessment of validity compared to 3D CT-scan. Knee 23:20–24CrossRefPubMed
5.
go back to reference Holme TJ, Henckel J, Hartshorn K, Cobb JP, Hart AJ (2015) Computed tomography scanogram compared to long leg radiograph for determining axial knee alignment. Acta Orthop 86:440–443CrossRefPubMedPubMedCentral Holme TJ, Henckel J, Hartshorn K, Cobb JP, Hart AJ (2015) Computed tomography scanogram compared to long leg radiograph for determining axial knee alignment. Acta Orthop 86:440–443CrossRefPubMedPubMedCentral
6.
go back to reference Khare R, Jaramaz B (2016) Accuracy of leg alignment measurements from antero-posterior radiographs. Biomed Tech (Berl) 62:315–320 Khare R, Jaramaz B (2016) Accuracy of leg alignment measurements from antero-posterior radiographs. Biomed Tech (Berl) 62:315–320
7.
go back to reference Sorin G, Pasquier G, Drumez E, Arnould A, Migaud H, Putman S (2016) Reproducibility of digital measurements of lower limb deformity on plain radiographs and agreement with CT measurements. Orthop Traumatol Surg Res 102:423–428CrossRefPubMed Sorin G, Pasquier G, Drumez E, Arnould A, Migaud H, Putman S (2016) Reproducibility of digital measurements of lower limb deformity on plain radiographs and agreement with CT measurements. Orthop Traumatol Surg Res 102:423–428CrossRefPubMed
8.
go back to reference Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement: a controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br 86:818–823CrossRefPubMed Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement: a controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br 86:818–823CrossRefPubMed
9.
go back to reference Jenny JY, Boeri C, Picard F, Leitner F (2004) Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system. Comput Aided Surg 9:161–165CrossRefPubMed Jenny JY, Boeri C, Picard F, Leitner F (2004) Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system. Comput Aided Surg 9:161–165CrossRefPubMed
10.
go back to reference Kobayashi H, Akamatsu Y, Kumagai K, Kusayama Y, Aratake M, Saito T (2017) Influence of coronal bowing on the lower alignment and the positioning of component in navigation and conventional total knee arthroplasty. Orthop Traumatol Surg Res 103:251–256CrossRefPubMed Kobayashi H, Akamatsu Y, Kumagai K, Kusayama Y, Aratake M, Saito T (2017) Influence of coronal bowing on the lower alignment and the positioning of component in navigation and conventional total knee arthroplasty. Orthop Traumatol Surg Res 103:251–256CrossRefPubMed
11.
go back to reference Desseaux A, Graf P, Dubrana F, Marino R, Clavé A (2016) Radiographic outcomes in the coronal plane with iASSIST™ versus optical navigation for total knee arthroplasty: a preliminary case-control study. Orthop Traumatol Surg Res 102:363–368CrossRefPubMed Desseaux A, Graf P, Dubrana F, Marino R, Clavé A (2016) Radiographic outcomes in the coronal plane with iASSIST™ versus optical navigation for total knee arthroplasty: a preliminary case-control study. Orthop Traumatol Surg Res 102:363–368CrossRefPubMed
12.
go back to reference Clarke JV, Riches PE, Picard F, Deakin AH (2012) Non-invasive computer-assisted measurement of knee alignment. Comput Aided Surg 17:29–39CrossRefPubMed Clarke JV, Riches PE, Picard F, Deakin AH (2012) Non-invasive computer-assisted measurement of knee alignment. Comput Aided Surg 17:29–39CrossRefPubMed
13.
go back to reference Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839CrossRefPubMed Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839CrossRefPubMed
14.
go back to reference Siu D, Cooke TD, Broekhoven LD, Lam M, Fisher B, Saunders G, Challis TW (1991) A standardized technique for lower limb radiography. Practice, applications, and error analysis. Invest Radiol 26:71–77CrossRefPubMed Siu D, Cooke TD, Broekhoven LD, Lam M, Fisher B, Saunders G, Challis TW (1991) A standardized technique for lower limb radiography. Practice, applications, and error analysis. Invest Radiol 26:71–77CrossRefPubMed
15.
go back to reference Potvin BM, Shourijeh MS, Smale KB, Benoit DL (2017) A practical solution to reduce soft tissue artifact error at the knee using adaptive kinematic constraints. J Biomech 62:124–131CrossRefPubMed Potvin BM, Shourijeh MS, Smale KB, Benoit DL (2017) A practical solution to reduce soft tissue artifact error at the knee using adaptive kinematic constraints. J Biomech 62:124–131CrossRefPubMed
16.
go back to reference Shetty GM, Mullaji A, Lingaraju AP, Bhayde S (2011) How accurate are orthopaedic surgeons in visually estimating lower limb alignment? Acta Orthop Belg 77:638–643PubMed Shetty GM, Mullaji A, Lingaraju AP, Bhayde S (2011) How accurate are orthopaedic surgeons in visually estimating lower limb alignment? Acta Orthop Belg 77:638–643PubMed
17.
go back to reference Lavernia C, D’Apuzzo M, Rossi MD, Lee D (2008) Accuracy of knee range of motion assessment after total knee arthroplasty. J Arthroplasty 23(Suppl 1):85–91CrossRefPubMed Lavernia C, D’Apuzzo M, Rossi MD, Lee D (2008) Accuracy of knee range of motion assessment after total knee arthroplasty. J Arthroplasty 23(Suppl 1):85–91CrossRefPubMed
18.
go back to reference Lenssen AF, van Dam EM, Crijns YH, Verhey M, Geesink RJ, van den Brandt PA, de Bie RA (2007) Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty. BMC Musculoskelet Disord 8:83CrossRefPubMedPubMedCentral Lenssen AF, van Dam EM, Crijns YH, Verhey M, Geesink RJ, van den Brandt PA, de Bie RA (2007) Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty. BMC Musculoskelet Disord 8:83CrossRefPubMedPubMedCentral
19.
go back to reference Bennett D, Hanratty B, Thompson N, Beverland D (2009) Measurement of knee joint motion using digital imaging. Int Orthop 33:1627–1631CrossRefPubMed Bennett D, Hanratty B, Thompson N, Beverland D (2009) Measurement of knee joint motion using digital imaging. Int Orthop 33:1627–1631CrossRefPubMed
20.
go back to reference Mündermann A, Dyrby CO, Andriacchi TP (2008) A comparison of measuring mechanical axis alignment using three-dimensional position capture with skin markers and radiographic measurements in patients with bilateral medial compartment knee osteoarthritis. Knee 15:480–485CrossRefPubMed Mündermann A, Dyrby CO, Andriacchi TP (2008) A comparison of measuring mechanical axis alignment using three-dimensional position capture with skin markers and radiographic measurements in patients with bilateral medial compartment knee osteoarthritis. Knee 15:480–485CrossRefPubMed
21.
go back to reference Lustig S, Magnussen RA, Cheze L, Neyret P (2012) The KneeKG system: a review of the literature. Knee Surg Sports Traumatol Arthrosc 20:633–638CrossRefPubMed Lustig S, Magnussen RA, Cheze L, Neyret P (2012) The KneeKG system: a review of the literature. Knee Surg Sports Traumatol Arthrosc 20:633–638CrossRefPubMed
22.
go back to reference Russell DF, Deakin AH, Fogg QA, Picard F (2013) Non-invasive, non-radiological quantification of anteroposterior knee joint ligamentous laxity: a study in cadavers. Bone Joint Res 2:233–237CrossRefPubMedPubMedCentral Russell DF, Deakin AH, Fogg QA, Picard F (2013) Non-invasive, non-radiological quantification of anteroposterior knee joint ligamentous laxity: a study in cadavers. Bone Joint Res 2:233–237CrossRefPubMedPubMedCentral
23.
go back to reference Russell DF, Deakin AH, Fogg QA, Picard F (2014) Quantitative measurement of lower limb mechanical alignment and coronal knee laxity in early flexion. Knee 21:1063–1068CrossRefPubMed Russell DF, Deakin AH, Fogg QA, Picard F (2014) Quantitative measurement of lower limb mechanical alignment and coronal knee laxity in early flexion. Knee 21:1063–1068CrossRefPubMed
24.
go back to reference Deep K, Picard F, Baines J (2016) Dynamic knee behaviour: does the knee deformity change as it is flexed-an assessment and classification with computer navigation. Knee Surg Sports Traumatol Arthrosc 24:3575–3583CrossRefPubMed Deep K, Picard F, Baines J (2016) Dynamic knee behaviour: does the knee deformity change as it is flexed-an assessment and classification with computer navigation. Knee Surg Sports Traumatol Arthrosc 24:3575–3583CrossRefPubMed
25.
go back to reference Sangeux M, Marin F, Charleux F, Dürselen L, Tho MCHB (2006) Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging. Clin Biomech 21:984–991CrossRef Sangeux M, Marin F, Charleux F, Dürselen L, Tho MCHB (2006) Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging. Clin Biomech 21:984–991CrossRef
Metadata
Title
Noninvasive navigated assessment of the lower limb axis prior to knee arthroplasty: a feasibility study
Authors
Jean-Yves Jenny
Gauthier Dillmann
Vincent Gisonni
Henri Favreau
Publication date
01-05-2019
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 4/2019
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-019-02380-z

Other articles of this Issue 4/2019

European Journal of Orthopaedic Surgery & Traumatology 4/2019 Go to the issue