Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 8/2018

01-12-2018 | Original Article • WRIST - FRACTURES

Treatment of distal radius fractures with locking plates: an update

Authors: Francois Loisel, Hugo Kielwasser, Grégoire Faivre, Thomas Rondot, Séverin Rochet, Antoine Adam, Pauline Sergent, Grégoire Leclerc, Laurent Obert, Daniel Lepage

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 8/2018

Login to get access

Abstract

Internal fixation with volar locking plates has revolutionized the treatment of distal radius fractures. Manufacturers have introduced plate designs that closely follow the anatomy of the distal radius. However, use of volar plates has also led to the emergence of new types of complications. While the use of monoaxial or polyaxial locking screws and of minimally invasive techniques (arthroscopy, preservation of pronator quadratus) increases the cost of the surgical procedure, it results in a tangible benefit for patients, allowing them to move their wrist almost immediately after surgery and to quickly regain their autonomy. We reviewed the literature to analyze the level of proof.
Literature
1.
go back to reference Koval KJ, Harrast JJ, Anglen JO, Weinstein JN (2008) Fractures of the distal part of the radius. The evolution of practice over time. Where’s the evidence? J Bone Joint Surg Am 90:1855–1861CrossRef Koval KJ, Harrast JJ, Anglen JO, Weinstein JN (2008) Fractures of the distal part of the radius. The evolution of practice over time. Where’s the evidence? J Bone Joint Surg Am 90:1855–1861CrossRef
2.
go back to reference Grewal R (2012) Acute management of distal radius fractures. In: Bhandari M (ed) Evidence-based orthopedics. Wiley, New York, pp 913–922 Grewal R (2012) Acute management of distal radius fractures. In: Bhandari M (ed) Evidence-based orthopedics. Wiley, New York, pp 913–922
3.
go back to reference MacDermid JC, Grewal R (2012) Prognosis, pain and disability after distal radius fracture. In: Bhandari M (ed) Evidence-based orthopedics. Wiley, New York, pp 923–929 MacDermid JC, Grewal R (2012) Prognosis, pain and disability after distal radius fracture. In: Bhandari M (ed) Evidence-based orthopedics. Wiley, New York, pp 923–929
4.
go back to reference Carter PR, Frederick HA, Laseter GF (1998) Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: a multicenter study of 73 patients. J Hand Surg Am 23:300–307CrossRef Carter PR, Frederick HA, Laseter GF (1998) Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: a multicenter study of 73 patients. J Hand Surg Am 23:300–307CrossRef
5.
go back to reference Rikli DA, Regazzoni P (1996) Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg Br 78:588–592CrossRef Rikli DA, Regazzoni P (1996) Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg Br 78:588–592CrossRef
6.
go back to reference Peine R, Rikli DA, Hoffmann R, Duda G, Regazzoni P (2000) Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study. J Hand Surg Am 25:29–33CrossRef Peine R, Rikli DA, Hoffmann R, Duda G, Regazzoni P (2000) Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study. J Hand Surg Am 25:29–33CrossRef
7.
go back to reference Hahnloser D, Platz A, Amgwerd M, Trentz O (1999) Internal fixation of distal radius fractures with dorsal dislocation; plate or two 1/4 plates? a prospective randomized study. J Trauma 47:760–765CrossRef Hahnloser D, Platz A, Amgwerd M, Trentz O (1999) Internal fixation of distal radius fractures with dorsal dislocation; plate or two 1/4 plates? a prospective randomized study. J Trauma 47:760–765CrossRef
8.
go back to reference Gesensway D, Putnam MD, Pl Mente, Lewis JL (1995) Design and biomechanics of a plate for the distal radius. J Hand Surg Am 20:1021–1027CrossRef Gesensway D, Putnam MD, Pl Mente, Lewis JL (1995) Design and biomechanics of a plate for the distal radius. J Hand Surg Am 20:1021–1027CrossRef
9.
go back to reference Cochran GVB (1993) A primer of orthopaedic biomechanics. Churchill Livingstone, New York, pp 143–216 Cochran GVB (1993) A primer of orthopaedic biomechanics. Churchill Livingstone, New York, pp 143–216
10.
go back to reference Obert L, Vichard P, Garbuio P, Tropet Y (2001) Ostéosynthèse des fractures du radius distal par plaque postérieure: avantages et inconvénients. Chir Main 20:436–446CrossRef Obert L, Vichard P, Garbuio P, Tropet Y (2001) Ostéosynthèse des fractures du radius distal par plaque postérieure: avantages et inconvénients. Chir Main 20:436–446CrossRef
11.
go back to reference Letsch R, Infanger M, Schimdt J, Koch HJ (2003) Surgical treatment of fractures of the distal radius with plates: a comparison of palmar and dorsal plate position. Arch Orthop Trauma Surg 123:333–339CrossRef Letsch R, Infanger M, Schimdt J, Koch HJ (2003) Surgical treatment of fractures of the distal radius with plates: a comparison of palmar and dorsal plate position. Arch Orthop Trauma Surg 123:333–339CrossRef
12.
go back to reference Finsen V, Asaheim T (2000) Initial experience with the forte plate for dorsally displaced distal radius fractures. Injury 31:445–448CrossRef Finsen V, Asaheim T (2000) Initial experience with the forte plate for dorsally displaced distal radius fractures. Injury 31:445–448CrossRef
13.
go back to reference Bahm J, Faye N, Nonnenmacher J (1994) Surgical treatment of fractures of the distal radius—a closed therapy concept. Initial results with the bowl osteosynthesis. Chirurg 65:999–1003PubMed Bahm J, Faye N, Nonnenmacher J (1994) Surgical treatment of fractures of the distal radius—a closed therapy concept. Initial results with the bowl osteosynthesis. Chirurg 65:999–1003PubMed
14.
go back to reference Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 27:205–215CrossRef Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 27:205–215CrossRef
15.
go back to reference Obert L, Rey PB, Uhring J, Gasse N, Rochet S, Lepage D, Serre A, Garbuio P (1993) Fixation of distal radius fractures in adults: a review. Orthop Traumatol Surg Res 99(2):216–234CrossRef Obert L, Rey PB, Uhring J, Gasse N, Rochet S, Lepage D, Serre A, Garbuio P (1993) Fixation of distal radius fractures in adults: a review. Orthop Traumatol Surg Res 99(2):216–234CrossRef
16.
go back to reference Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ (2004) Biomechanics of locked plates and screws. J Orthop Trauma 18:488–493CrossRef Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ (2004) Biomechanics of locked plates and screws. J Orthop Trauma 18:488–493CrossRef
17.
go back to reference Levin SM, Nelson CO, Botts JD, Teplitz GA, Kwon Y, Serra-Hsu F (2008) Biomechanical evaluation of volar locking plates for distal radius fractures. Hand 3:55–60CrossRef Levin SM, Nelson CO, Botts JD, Teplitz GA, Kwon Y, Serra-Hsu F (2008) Biomechanical evaluation of volar locking plates for distal radius fractures. Hand 3:55–60CrossRef
18.
go back to reference Trease C, Mc Iff T, Toby EB (2005) Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study. J Hand Surg Am 30:756–763CrossRef Trease C, Mc Iff T, Toby EB (2005) Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study. J Hand Surg Am 30:756–763CrossRef
19.
go back to reference Koh S, Morris RP, Patterson RM, Kearney JP, Buford WL, Viegas SF (2006) Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study. J Hand Surg Am 31:771–779CrossRef Koh S, Morris RP, Patterson RM, Kearney JP, Buford WL, Viegas SF (2006) Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study. J Hand Surg Am 31:771–779CrossRef
20.
go back to reference Drobetz H, Bryant AL, Pokorny T, Spitaler R, Leixnering M, Jupiter JB (2006) Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction—a biomechanic study in a cadaveric model. J Hand Surg Am 31:615–622CrossRef Drobetz H, Bryant AL, Pokorny T, Spitaler R, Leixnering M, Jupiter JB (2006) Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction—a biomechanic study in a cadaveric model. J Hand Surg Am 31:615–622CrossRef
21.
go back to reference Koshimune M, Kamano M, Takamatsu K, Ohashi H (2005) A randomized comparison of locking and non-locking palmar plating for unstable Colles’ fractures in the elderly. J Hand Surg Br 30:499–503CrossRef Koshimune M, Kamano M, Takamatsu K, Ohashi H (2005) A randomized comparison of locking and non-locking palmar plating for unstable Colles’ fractures in the elderly. J Hand Surg Br 30:499–503CrossRef
22.
go back to reference Huard S, Blanchet N, Leclerc G, Rochet S, Lepage D, Garbuio P, Obert L (2010) Fractures of the distal radius in patients over 70 years old: volar plates or K-wires? Chir Main 29:236–241CrossRef Huard S, Blanchet N, Leclerc G, Rochet S, Lepage D, Garbuio P, Obert L (2010) Fractures of the distal radius in patients over 70 years old: volar plates or K-wires? Chir Main 29:236–241CrossRef
23.
go back to reference Herron M, Faraj A, Craigen MA (2003) Dorsal plating for displaced intra-articular fractures of the distal radius. Injury 34:497–502CrossRef Herron M, Faraj A, Craigen MA (2003) Dorsal plating for displaced intra-articular fractures of the distal radius. Injury 34:497–502CrossRef
24.
go back to reference Arora R, Lutz M, Deml C, Krappinger D, Haug L, Gabl M (2011) A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Joint Surg Am 7(93):2146–2153CrossRef Arora R, Lutz M, Deml C, Krappinger D, Haug L, Gabl M (2011) A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Joint Surg Am 7(93):2146–2153CrossRef
25.
go back to reference Loisel F, Bouilloux X, Uhring J, Rochet S, Obert L (2015) Early postoperative improvements in the QuickDASH score after distal radius fracture are related to the type of surgical treatment. Eur J Orthop Surg Traumatol 25:865–869CrossRef Loisel F, Bouilloux X, Uhring J, Rochet S, Obert L (2015) Early postoperative improvements in the QuickDASH score after distal radius fracture are related to the type of surgical treatment. Eur J Orthop Surg Traumatol 25:865–869CrossRef
26.
go back to reference Voigt C, Lill H (2006) What advantages does volar plate fixation have over K-wire fixation for distal radius extension fractures in the elderly? Unfallchirurg 109(845–6):8–54 Voigt C, Lill H (2006) What advantages does volar plate fixation have over K-wire fixation for distal radius extension fractures in the elderly? Unfallchirurg 109(845–6):8–54
27.
go back to reference Drobetz H, Koval L, Weninger P, Luscombe R, Jeffries P, Ehrendorfer S, Heal C (2016) Volar locking distal radius plates show better short-term results than other treatment options: a prospective randomised controlled trial. World J Orthop 18(7):687–694CrossRef Drobetz H, Koval L, Weninger P, Luscombe R, Jeffries P, Ehrendorfer S, Heal C (2016) Volar locking distal radius plates show better short-term results than other treatment options: a prospective randomised controlled trial. World J Orthop 18(7):687–694CrossRef
Metadata
Title
Treatment of distal radius fractures with locking plates: an update
Authors
Francois Loisel
Hugo Kielwasser
Grégoire Faivre
Thomas Rondot
Séverin Rochet
Antoine Adam
Pauline Sergent
Grégoire Leclerc
Laurent Obert
Daniel Lepage
Publication date
01-12-2018
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 8/2018
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-018-2274-z

Other articles of this Issue 8/2018

European Journal of Orthopaedic Surgery & Traumatology 8/2018 Go to the issue

General Review • GENERAL ORTHOPAEDICS - RADIOLOGY

C-arm fluoroscopy in orthopaedic surgical practice