Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 8/2018

01-12-2018 | General Review • WRIST - FRACTURES

Is the external fixator yet useful for treating fractures of the distal radius?

Author: Michel Rongières

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 8/2018

Login to get access

Excerpt

We do not use external fixator (EF) in fractures of the distal radius (FDR) but open reduction and internal fixation (ORIF) with volar plate (VP). In this publication, we will try to show that EF can be used to prepare a correct ORIF before plating the fracture but not as a definitive technique. …
Literature
1.
go back to reference Pennig DW (1993) Dynamic external fixation of distal radius fractures. Hand Clin 9:587–602PubMed Pennig DW (1993) Dynamic external fixation of distal radius fractures. Hand Clin 9:587–602PubMed
2.
go back to reference Jakim I, Pieterse HS, Sweet MB (1991) External fixation for intra-articular fractures of the distal radius. J Bone Joint Surg Am 73:302–306CrossRef Jakim I, Pieterse HS, Sweet MB (1991) External fixation for intra-articular fractures of the distal radius. J Bone Joint Surg Am 73:302–306CrossRef
3.
go back to reference Farah N, Nassar L, Farah Z, Schuind F (2014) Secondary displacement of distal radius fractures treated by bridging external fixation. J Hand Surg Eur 39:423–428CrossRef Farah N, Nassar L, Farah Z, Schuind F (2014) Secondary displacement of distal radius fractures treated by bridging external fixation. J Hand Surg Eur 39:423–428CrossRef
4.
go back to reference Herzberg G, Dumontier C (2000) Symposium: les fractures fraîches du radius distal chez l’adulte. Rev Chir Orthop 86(suppl1):1585–1588 Herzberg G, Dumontier C (2000) Symposium: les fractures fraîches du radius distal chez l’adulte. Rev Chir Orthop 86(suppl1):1585–1588
5.
go back to reference Cui Z, Yu B, Hu Y, Lin Q, Wang B (2012) Dynamic versus static external fixation for unstable distal radius fractures: an up-to-date meta-analysis. Injury 43:1006–1013CrossRef Cui Z, Yu B, Hu Y, Lin Q, Wang B (2012) Dynamic versus static external fixation for unstable distal radius fractures: an up-to-date meta-analysis. Injury 43:1006–1013CrossRef
6.
go back to reference Vidal J, Buscayret C, Fischbach C, Brahin B, Paran M, Escare P (1977) Une méthode originale dans le traitement des fractures comminutives de l’extrémité inférieure du radius : le taxis ligamentaire. Acta Orthop Belg 43:781–789PubMed Vidal J, Buscayret C, Fischbach C, Brahin B, Paran M, Escare P (1977) Une méthode originale dans le traitement des fractures comminutives de l’extrémité inférieure du radius : le taxis ligamentaire. Acta Orthop Belg 43:781–789PubMed
7.
go back to reference Gu GL, Wang J, Li DQ, Gong MZ et al (2016) Bridging external fixation versus non bridging external fixation for unstable distal radius fractures: a systematic review and meta-analysis. J Orthop Science 21:24–31CrossRef Gu GL, Wang J, Li DQ, Gong MZ et al (2016) Bridging external fixation versus non bridging external fixation for unstable distal radius fractures: a systematic review and meta-analysis. J Orthop Science 21:24–31CrossRef
8.
go back to reference Margaliot Z, Haase SC, Kotsis SV, Myra Kim H, Chung KC (2005) A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures. J Hand Surg Am 30:1185–1199CrossRef Margaliot Z, Haase SC, Kotsis SV, Myra Kim H, Chung KC (2005) A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures. J Hand Surg Am 30:1185–1199CrossRef
9.
go back to reference Esposito J, Schemitsch EH, Saccone M, Sternheim A, Kuzyk PRT (2013) External fixation versus open reduction with plate fixation for distal radius fractures: a meta-analysis of randomised controlled trials. Injury 44:409–416CrossRef Esposito J, Schemitsch EH, Saccone M, Sternheim A, Kuzyk PRT (2013) External fixation versus open reduction with plate fixation for distal radius fractures: a meta-analysis of randomised controlled trials. Injury 44:409–416CrossRef
10.
go back to reference Cui Z, Yu B, Hu Y, Lin Q, Wang B (2012) Dynamic versus static external fixation for unstable distal radius fractures: an up-to-date meta-analysis. Injury 43:1013–1016CrossRef Cui Z, Yu B, Hu Y, Lin Q, Wang B (2012) Dynamic versus static external fixation for unstable distal radius fractures: an up-to-date meta-analysis. Injury 43:1013–1016CrossRef
11.
go back to reference Grewal R, MacDermid JC, King GLW, Faber KJ (2011) Open reduction internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial. J Hand surg Am 36:1899–1906CrossRef Grewal R, MacDermid JC, King GLW, Faber KJ (2011) Open reduction internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial. J Hand surg Am 36:1899–1906CrossRef
12.
go back to reference Marc J, Richard MJ, Wartinbee DA, Riboh J, Miller M, Leversedge FJ, Ruch DS (2011) Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius. J Hand Surg Am 36:1614–1620CrossRef Marc J, Richard MJ, Wartinbee DA, Riboh J, Miller M, Leversedge FJ, Ruch DS (2011) Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius. J Hand Surg Am 36:1614–1620CrossRef
13.
go back to reference Jeudy J, Steiger V, Boyer P, Cronier P, Bizot P, Massin P (2012) Treatment of complex fractures of the distal radius: a prospective randomised comparison of external fixation ‘versus’ locked volar plating. Injury 43:174–179CrossRef Jeudy J, Steiger V, Boyer P, Cronier P, Bizot P, Massin P (2012) Treatment of complex fractures of the distal radius: a prospective randomised comparison of external fixation ‘versus’ locked volar plating. Injury 43:174–179CrossRef
14.
go back to reference Capo JT, Rossy W, Henry P, Maurer RJ, Naidu S, Chen L (2009) External fixation of distal radius fractures: effect of distraction and duration. J Hand Surg Am 34:1605–1611CrossRef Capo JT, Rossy W, Henry P, Maurer RJ, Naidu S, Chen L (2009) External fixation of distal radius fractures: effect of distraction and duration. J Hand Surg Am 34:1605–1611CrossRef
15.
go back to reference Rongieres M (2016) Is external or internal distraction useful for treating distal radial fractures? Hand Surg Rehabil 35:86–88CrossRef Rongieres M (2016) Is external or internal distraction useful for treating distal radial fractures? Hand Surg Rehabil 35:86–88CrossRef
Metadata
Title
Is the external fixator yet useful for treating fractures of the distal radius?
Author
Michel Rongières
Publication date
01-12-2018
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 8/2018
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-018-2237-4

Other articles of this Issue 8/2018

European Journal of Orthopaedic Surgery & Traumatology 8/2018 Go to the issue

General Review • GENERAL ORTHOPAEDICS - RADIOLOGY

C-arm fluoroscopy in orthopaedic surgical practice