Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 4/2014

01-05-2014 | Technical Note

The reinforcement of a C2 laminar screw by a C2 laminar hook as an anchor of occipito-C2 fusion

Authors: Masashi Neo, Hiroyuki Yoshitomi, Mitsuru Takemoto, Masanori Izeki

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 4/2014

Login to get access

Abstract

Although a C1–C2 transarticular screw (TAS) or a C2 pedicle screw (PS) is the most rigid anchor for C2, each entails the risk of vertebral artery injury. Although a C2 laminar screw (LS) is often used as an alternative anchor in such cases, its anchoring strength may be inadequate. We introduce a technical tip, in which a C2 LS is reinforced by a C2 infralaminar hook without extending the fusion range. Six patients, for whom a unilateral TAS or C2 PS was risky or impossible, were treated with O-C2 fusion using this technique. The post-operative course of each patient was uneventful. Bone union was achieved in all patients, except one who died of indifferent disease before the confirmation of bone union by computed tomography. This method would be a safe and non-technical-demanding option when the placement of a TAS or PS is risky or impossible.
Literature
1.
go back to reference Melcher RP, Puttlitz CM, Kleinstueck FS, Lotz JC, Harms J, Bradford DS (2002) Biomechanical testing of posterior atlantoaxial fixation techniques. Spine 27:2435–2440PubMedCrossRef Melcher RP, Puttlitz CM, Kleinstueck FS, Lotz JC, Harms J, Bradford DS (2002) Biomechanical testing of posterior atlantoaxial fixation techniques. Spine 27:2435–2440PubMedCrossRef
2.
go back to reference Neo M, Matsushita M, Iwashita Y, Yasuda T, Sakamoto T, Nakamura T (2003) Atlantoaxial transarticular screw fixation for a high-riding vertebral artery. Spine 28:666–670PubMedCrossRef Neo M, Matsushita M, Iwashita Y, Yasuda T, Sakamoto T, Nakamura T (2003) Atlantoaxial transarticular screw fixation for a high-riding vertebral artery. Spine 28:666–670PubMedCrossRef
3.
go back to reference Neo M, Sakamoto T, Fujibayashi S, Nakmaura T (2005) The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine 30:2800–2805PubMedCrossRef Neo M, Sakamoto T, Fujibayashi S, Nakmaura T (2005) The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine 30:2800–2805PubMedCrossRef
4.
go back to reference Yoshida M, Neo M, Fujibayashi S, Nakmaura T (2006) Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Spine 31:E513–E517PubMedCrossRef Yoshida M, Neo M, Fujibayashi S, Nakmaura T (2006) Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Spine 31:E513–E517PubMedCrossRef
5.
go back to reference Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158–162PubMedCrossRef Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158–162PubMedCrossRef
6.
go back to reference Wright NM (2005) Translaminar rigid screw fixation of axis. Technical note. J Neurosurg 3:409–414 Wright NM (2005) Translaminar rigid screw fixation of axis. Technical note. J Neurosurg 3:409–414
7.
8.
go back to reference Lehman RA, Dmitriev AE, Helgeson MD, Sasso RC, Kuklo TR, Riew KD (2008) Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine 20:960–965CrossRef Lehman RA, Dmitriev AE, Helgeson MD, Sasso RC, Kuklo TR, Riew KD (2008) Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine 20:960–965CrossRef
9.
go back to reference Claybrooks R, Kayanja M, Milks R, Benzel E (2007) Atlantoaxial fusion: a biomechanical analysis of two C1–C2 fusion techniques. Spine J 7:682–688PubMedCrossRef Claybrooks R, Kayanja M, Milks R, Benzel E (2007) Atlantoaxial fusion: a biomechanical analysis of two C1–C2 fusion techniques. Spine J 7:682–688PubMedCrossRef
10.
go back to reference Hong JT, Takigawa T, Udayakunmar R, Shin HK, Simon P, Espinoza Orías AA, Inoue N, An HS (2011) Biomechanical effect of the C2 laminar decortication on the stability of C2 intralaminar screw construct and biomechanical comparison of C2 intralaminar screw and C2 pars screw. Neurosurgery 69(1 Suppl Operative):ons 1–6 Hong JT, Takigawa T, Udayakunmar R, Shin HK, Simon P, Espinoza Orías AA, Inoue N, An HS (2011) Biomechanical effect of the C2 laminar decortication on the stability of C2 intralaminar screw construct and biomechanical comparison of C2 intralaminar screw and C2 pars screw. Neurosurgery 69(1 Suppl Operative):ons 1–6
11.
go back to reference Yoshitomi H, Neo M, Ito H, Takemoto M, Masaski Y, Nakamura T (2011) Doppler ultrasonography and computed tomography angiography demonstrate positional occlusion of vertebral artery associated with one-sided destruction of the atlantoaxial lateral mass caused by rheumatoid arthritis: a case report. Spine 36:E1493–E1496PubMedCrossRef Yoshitomi H, Neo M, Ito H, Takemoto M, Masaski Y, Nakamura T (2011) Doppler ultrasonography and computed tomography angiography demonstrate positional occlusion of vertebral artery associated with one-sided destruction of the atlantoaxial lateral mass caused by rheumatoid arthritis: a case report. Spine 36:E1493–E1496PubMedCrossRef
12.
go back to reference Chiba M, McLain RF, Yerby SA, Moseley TA, Smith TS, Benson DR (1996) Short-segment pedicle instrumentation: biomechanical analysis of supplemental hook fixation. Spine 21:288–294PubMedCrossRef Chiba M, McLain RF, Yerby SA, Moseley TA, Smith TS, Benson DR (1996) Short-segment pedicle instrumentation: biomechanical analysis of supplemental hook fixation. Spine 21:288–294PubMedCrossRef
13.
go back to reference Sun E, Alkalay R, Vader D, Snyder BD (2009) Preventing distal pullout of posterior spine instrumentation in thoracic hyperkyphosis. A biomechanical analysis. J Spinal Disord Tech 22:270–277PubMedCrossRef Sun E, Alkalay R, Vader D, Snyder BD (2009) Preventing distal pullout of posterior spine instrumentation in thoracic hyperkyphosis. A biomechanical analysis. J Spinal Disord Tech 22:270–277PubMedCrossRef
14.
go back to reference Hasegawa K, Takahashi HE, Uchiyama S, Hirano T, Hara T, Washino T, Sugiura T, Youkaichiya M, Ikeda M (1997) An experimental study of a combination method using a pedicle screw and laminar hook for the osteoporotic spine. Spine 22:958–962PubMedCrossRef Hasegawa K, Takahashi HE, Uchiyama S, Hirano T, Hara T, Washino T, Sugiura T, Youkaichiya M, Ikeda M (1997) An experimental study of a combination method using a pedicle screw and laminar hook for the osteoporotic spine. Spine 22:958–962PubMedCrossRef
15.
go back to reference Miyata M, Neo M, Ito H, Yoshida M, Miyaki K, Fujibayashi S, Nakayama T, Nakamura T (2008) Is rheumatoid arthritis a risk factor for a high-riding vertebral artery? Spine 33:2007–2011PubMedCrossRef Miyata M, Neo M, Ito H, Yoshida M, Miyaki K, Fujibayashi S, Nakayama T, Nakamura T (2008) Is rheumatoid arthritis a risk factor for a high-riding vertebral artery? Spine 33:2007–2011PubMedCrossRef
16.
go back to reference Miyata M, Neo M, Ito H, Yoshida M, Fujibayashi S, Nakamura T (2008) Rheumatoid arthritis as a risk factor for a narrow C-2 pedicle: 3D analysis of the C-2 pedicle screw trajectory. J Neutrosurg Spine 9:17–21CrossRef Miyata M, Neo M, Ito H, Yoshida M, Fujibayashi S, Nakamura T (2008) Rheumatoid arthritis as a risk factor for a narrow C-2 pedicle: 3D analysis of the C-2 pedicle screw trajectory. J Neutrosurg Spine 9:17–21CrossRef
17.
go back to reference Paxinos O, Tsitsopoulos PP, Zindrick MR, Voronov LI, Lorenz MA, Havey RM, Patwardhan AG (2010) Evaluation of pullout strength and failure mechanism of posterior instrumentation in normal and osteopenic thoracic vertebrae. J Neurosurg Spine 13:469–476PubMedCrossRef Paxinos O, Tsitsopoulos PP, Zindrick MR, Voronov LI, Lorenz MA, Havey RM, Patwardhan AG (2010) Evaluation of pullout strength and failure mechanism of posterior instrumentation in normal and osteopenic thoracic vertebrae. J Neurosurg Spine 13:469–476PubMedCrossRef
Metadata
Title
The reinforcement of a C2 laminar screw by a C2 laminar hook as an anchor of occipito-C2 fusion
Authors
Masashi Neo
Hiroyuki Yoshitomi
Mitsuru Takemoto
Masanori Izeki
Publication date
01-05-2014
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 4/2014
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-013-1349-0

Other articles of this Issue 4/2014

European Journal of Orthopaedic Surgery & Traumatology 4/2014 Go to the issue