Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 7/2014

01-10-2014 | Original Article

Three-column classification and Schatzker classification: a three- and two-dimensional computed tomography characterisation and analysis of tibial plateau fractures

Authors: Sheethal Prasad Patange Subba Rao, James Lewis, Ziad Haddad, Vishal Paringe, Khitish Mohanty

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 7/2014

Login to get access

Abstract

Objective

The aim of the study was to evaluate inter-observer reliability and intra-observer reproducibility between the three-column classification and Schatzker classification systems using 2D and 3D CT models.

Materials and methods

Fifty-two consecutive patients with tibial plateau fractures were evaluated by five orthopaedic surgeons. All patients were classified into Schatzker and three-column classification systems using x-rays and 2D and 3D CT images. The inter-observer reliability was evaluated in the first round and the intra-observer reliability was determined during the second round 2 weeks later.

Results

The average intra-observer reproducibility for the three-column classification was from substantial to excellent in all sub classifications, as compared with Schatzker classification. The inter-observer kappa values increased from substantial to excellent in three-column classification and to moderate in Schatzker classification The average values for three-column classification for all the categories are as follows: (I–III) k2D = 0.718, 95 % CI 0.554–0.864, p < 0.0001 and average 3D = 0.874, 95 % CI 0.754–0.890, p < 0.0001. For Schatzker classification system, the average values for all six categories are as follows: (I–VI) k2D = 0.536, 95 % CI 0.365–0.685, p < 0.0001 and average k3D = 0.552 95 % CI 0.405–0.700, p < 0.0001. The values are statistically significant.

Conclusion

Statistically significant inter-observer values in both rounds were noted with the three-column classification, making it statistically an excellent agreement. The intra-observer reproducibility for the three-column classification improved as compared with the Schatzker classification. The three-column classification seems to be an effective way to characterise and classify fractures of tibial plateau.
Literature
1.
go back to reference Biggi F, Di Fabio S, D’Antimo C, Trevisani S (2010) Tibial plateau fractures: internal fixation with locking plates and the MIPO technique. Injury Int J Care Injured 41:1178–1182CrossRef Biggi F, Di Fabio S, D’Antimo C, Trevisani S (2010) Tibial plateau fractures: internal fixation with locking plates and the MIPO technique. Injury Int J Care Injured 41:1178–1182CrossRef
2.
go back to reference Chin TYP, Bardana D, Bailey M, Williamson OD, Miller R, Edwards ER, Esser MP (2005) Functional outcome of tibial plateau fractures treated with the fine-wire fixator. Injury Int J Care Injured 36:1467–1475CrossRef Chin TYP, Bardana D, Bailey M, Williamson OD, Miller R, Edwards ER, Esser MP (2005) Functional outcome of tibial plateau fractures treated with the fine-wire fixator. Injury Int J Care Injured 36:1467–1475CrossRef
3.
go back to reference Schatzker J (1987) Fractures of the tibial plateau. In: Schatzker J, Tile M (eds) The rationale of operative fracture care. Springer, New York, pp 279–295CrossRef Schatzker J (1987) Fractures of the tibial plateau. In: Schatzker J, Tile M (eds) The rationale of operative fracture care. Springer, New York, pp 279–295CrossRef
4.
go back to reference Watson JT (1994) High-energy Fractures of the tibial plateau. Orthop Clin North Am 25(4):723–751PubMed Watson JT (1994) High-energy Fractures of the tibial plateau. Orthop Clin North Am 25(4):723–751PubMed
5.
go back to reference Ali AM, Yang L, Hashmi M, Saleh M (2001) Bicondylar tibial plateau fractures managed with the Sheffield Hybrid Fixator Biomechanical study and operative technique-Injury. Int J Care Injured 32:86–91CrossRef Ali AM, Yang L, Hashmi M, Saleh M (2001) Bicondylar tibial plateau fractures managed with the Sheffield Hybrid Fixator Biomechanical study and operative technique-Injury. Int J Care Injured 32:86–91CrossRef
6.
go back to reference Doornberg JN, Rademakers MV, Van den Bekerom MP, Kerkhoffs GM, Ahn J, Steller EPh, Kloen P (2011) Two-dimensional and three-dimensional computed tomography for the classification and characterisation of tibial plateau fractures. Injury Int J Care Injured 42:1416–1425CrossRef Doornberg JN, Rademakers MV, Van den Bekerom MP, Kerkhoffs GM, Ahn J, Steller EPh, Kloen P (2011) Two-dimensional and three-dimensional computed tomography for the classification and characterisation of tibial plateau fractures. Injury Int J Care Injured 42:1416–1425CrossRef
7.
go back to reference Hu YL, Ye FG, Ji AY, Qiao GX, Liu HF (2009) Three-dimensional computed tomography imaging increases the reliability of classification systems for tibial plateau fractures. Injury Int J Care Injured 40:1282–1285CrossRef Hu YL, Ye FG, Ji AY, Qiao GX, Liu HF (2009) Three-dimensional computed tomography imaging increases the reliability of classification systems for tibial plateau fractures. Injury Int J Care Injured 40:1282–1285CrossRef
8.
go back to reference Tscherne H, Lobenhoffer P (1993) Tibial plateau fractures. Management and expected results. Clin Orthop Relat Res 292:87–100PubMed Tscherne H, Lobenhoffer P (1993) Tibial plateau fractures. Management and expected results. Clin Orthop Relat Res 292:87–100PubMed
9.
go back to reference Koval KJ, Helfet DL (1995) Tibial plateau fractures: evaluation and treatment. J Am Acad Orthop Surg 3:86–94PubMed Koval KJ, Helfet DL (1995) Tibial plateau fractures: evaluation and treatment. J Am Acad Orthop Surg 3:86–94PubMed
10.
go back to reference Papagelopoulos PJ, Partsinevelos AA, Themistocleous GS et al (2006) Complications after tibia plateau fracture surgery. Injury 37(6):475–484PubMedCrossRef Papagelopoulos PJ, Partsinevelos AA, Themistocleous GS et al (2006) Complications after tibia plateau fracture surgery. Injury 37(6):475–484PubMedCrossRef
11.
go back to reference Hohl M, Moore TM (1990) Articular fractures of the proximal tibia. In: Evarts CM (ed) Surgery of the musculoskeletal system, 2nd edn. Churchill Livingstone, New York Hohl M, Moore TM (1990) Articular fractures of the proximal tibia. In: Evarts CM (ed) Surgery of the musculoskeletal system, 2nd edn. Churchill Livingstone, New York
12.
go back to reference Schatzker J, McBroom R, Bruce D (1979) The tibial plateau fracture; The Toronto experience 1968–1975. Clin Orthop Relat Res 138:94–104PubMed Schatzker J, McBroom R, Bruce D (1979) The tibial plateau fracture; The Toronto experience 1968–1975. Clin Orthop Relat Res 138:94–104PubMed
13.
go back to reference Müller ME, Nazarian S, Koch P, Schatzker J (1990) The comprehensive classification of fractures in long bones. Springer, BerlinCrossRef Müller ME, Nazarian S, Koch P, Schatzker J (1990) The comprehensive classification of fractures in long bones. Springer, BerlinCrossRef
14.
go back to reference Maripuri SN, Rao P, Manoj-Thomas A, Mohanty K (2008) The classification systems for tibial plateau fractures: how reliable are they? Injury Int J Care Injured 39:1216–1221CrossRef Maripuri SN, Rao P, Manoj-Thomas A, Mohanty K (2008) The classification systems for tibial plateau fractures: how reliable are they? Injury Int J Care Injured 39:1216–1221CrossRef
15.
go back to reference Luo CF, Sun H, Zhang B, Zeng B (2010) Three-column fixation for complex tibial plateau fractures. J Orthop Trauma 24(11):683–692PubMedCrossRef Luo CF, Sun H, Zhang B, Zeng B (2010) Three-column fixation for complex tibial plateau fractures. J Orthop Trauma 24(11):683–692PubMedCrossRef
16.
go back to reference Suero EM, Hufner T, Stubig T, Krettek C, Citak M (2010) Use of a virtual 3D software for planning of tibial plateau fracture reconstruction. Injury Int J Care Injured 41:589–591CrossRef Suero EM, Hufner T, Stubig T, Krettek C, Citak M (2010) Use of a virtual 3D software for planning of tibial plateau fracture reconstruction. Injury Int J Care Injured 41:589–591CrossRef
17.
go back to reference Brunner A, Horisberger M, Ulmar B, Hoffmann A, Babst R (2012) Classification systems for tibial plateau fractures; does computed tomography scanning improve their reliability? Injury 41(2):173–178CrossRef Brunner A, Horisberger M, Ulmar B, Hoffmann A, Babst R (2012) Classification systems for tibial plateau fractures; does computed tomography scanning improve their reliability? Injury 41(2):173–178CrossRef
18.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174PubMedCrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174PubMedCrossRef
19.
go back to reference Charalambous CP, Tryfonidis M, Alvi F et al (2007) Inter- and intra-observer variation of the Schatzker and AO/OTA classifications of tibial plateau fractures and a proposal of a new classification system. Ann R Coll Surg Engl 89(4):400–404PubMedCentralPubMedCrossRef Charalambous CP, Tryfonidis M, Alvi F et al (2007) Inter- and intra-observer variation of the Schatzker and AO/OTA classifications of tibial plateau fractures and a proposal of a new classification system. Ann R Coll Surg Engl 89(4):400–404PubMedCentralPubMedCrossRef
20.
go back to reference Malek IA, Machani B, Mevcha AM, Hyder NH (2006) Inter-observer reliability and intra-observer reproducibility of the Weber classification of ankle fractures. J Bone Joint Surg Br 88(9):1204–1206PubMedCrossRef Malek IA, Machani B, Mevcha AM, Hyder NH (2006) Inter-observer reliability and intra-observer reproducibility of the Weber classification of ankle fractures. J Bone Joint Surg Br 88(9):1204–1206PubMedCrossRef
21.
go back to reference Walton NP, Harish S, Roberts C, Blundell C (2003) AO or Schatzker? How reliable is classification of tibial plateau fractures? Arch Orthop Trauma Surg 123(8):396–398PubMedCrossRef Walton NP, Harish S, Roberts C, Blundell C (2003) AO or Schatzker? How reliable is classification of tibial plateau fractures? Arch Orthop Trauma Surg 123(8):396–398PubMedCrossRef
22.
go back to reference Smith SW, Meyer RA, Connor PM et al (1996) Interobserver reliability and intraobserver reproducibility of the modified Ficat classification system of osteonecrosis of the femoral head. J Bone Joint Surg Am 78(11):1702–1706PubMed Smith SW, Meyer RA, Connor PM et al (1996) Interobserver reliability and intraobserver reproducibility of the modified Ficat classification system of osteonecrosis of the femoral head. J Bone Joint Surg Am 78(11):1702–1706PubMed
23.
go back to reference Wainwright AM, Williams JR, Carr AJ (2000) Interobserver and intraobserver variation in classification systems for fractures of the distal humerus. J Bone Joint Surg Br 82:636–642PubMedCrossRef Wainwright AM, Williams JR, Carr AJ (2000) Interobserver and intraobserver variation in classification systems for fractures of the distal humerus. J Bone Joint Surg Br 82:636–642PubMedCrossRef
24.
go back to reference Sidor ML, Zuckerman JD, Lyon T et al (1993) The Neer classification system for proximal humeral fractures. An assessment of interobserver reliability and intraobserver reproducibility. J Bone Joint Surg Am 75(12):1745–1750PubMed Sidor ML, Zuckerman JD, Lyon T et al (1993) The Neer classification system for proximal humeral fractures. An assessment of interobserver reliability and intraobserver reproducibility. J Bone Joint Surg Am 75(12):1745–1750PubMed
25.
go back to reference Chan PS, Klimkiewicz JJ, Luchetti WT et al (1997) Impact of CT scan on treatment plan and fracture classification of tibial plateau fractures. J Orthop Trauma 7:484–489CrossRef Chan PS, Klimkiewicz JJ, Luchetti WT et al (1997) Impact of CT scan on treatment plan and fracture classification of tibial plateau fractures. J Orthop Trauma 7:484–489CrossRef
26.
go back to reference Wicky S, Blaser PF, Blanc CH et al (2000) Comparison between standard radiography and spiral CT with 3D reconstruction in the evaluation, classification and management of tibial plateau fractures. Eur Radiol 10:1227–1232PubMedCrossRef Wicky S, Blaser PF, Blanc CH et al (2000) Comparison between standard radiography and spiral CT with 3D reconstruction in the evaluation, classification and management of tibial plateau fractures. Eur Radiol 10:1227–1232PubMedCrossRef
27.
go back to reference Yacoubian SV, Nevins RT, Sallis JG et al (2002) Impact of MRI on treatment plan and fracture classification of tibial plateau fractures. J Orthop Trauma 16:632–637PubMedCrossRef Yacoubian SV, Nevins RT, Sallis JG et al (2002) Impact of MRI on treatment plan and fracture classification of tibial plateau fractures. J Orthop Trauma 16:632–637PubMedCrossRef
28.
go back to reference Kode L, Lieberman JM, Motta AO, Wilber JH, Vasen A, Yagan R (1994) Evaluation of tibial plateau fractures: efficacy of MR imaging compared with CT. AJR Am J Roentgenol 163(1):141–147PubMedCrossRef Kode L, Lieberman JM, Motta AO, Wilber JH, Vasen A, Yagan R (1994) Evaluation of tibial plateau fractures: efficacy of MR imaging compared with CT. AJR Am J Roentgenol 163(1):141–147PubMedCrossRef
29.
go back to reference Pilson HT, Reddix Jr RN, Mutty CE, Webb LX (2008) The long lost art of preoperative planning—resurrected? Orthopedics 31 Pilson HT, Reddix Jr RN, Mutty CE, Webb LX (2008) The long lost art of preoperative planning—resurrected? Orthopedics 31
30.
go back to reference Citak M, Citak M, Kendoff D et al. (2009) Estimation of pretraumatic femoral antetorsion in bilateral femoral shaft fractures. Skeletal Radiol Citak M, Citak M, Kendoff D et al. (2009) Estimation of pretraumatic femoral antetorsion in bilateral femoral shaft fractures. Skeletal Radiol
31.
go back to reference Citak M, Gardner MJ, Kendoff D et al (2008) Virtual 3D planning of acetabular fracture Reduction. J Orthop Res 26:547–552PubMedCrossRef Citak M, Gardner MJ, Kendoff D et al (2008) Virtual 3D planning of acetabular fracture Reduction. J Orthop Res 26:547–552PubMedCrossRef
32.
go back to reference Gosling T, Klingler K, Geerling J et al (2009) Improved intra-operative reduction control using a three-dimensional mobile image intensifier—a proximal tibia cadaver study. Knee 16:58–63PubMedCrossRef Gosling T, Klingler K, Geerling J et al (2009) Improved intra-operative reduction control using a three-dimensional mobile image intensifier—a proximal tibia cadaver study. Knee 16:58–63PubMedCrossRef
33.
go back to reference HacklW Riedl J, Reichkendler M et al (2001) Preoperative computerized tomography diagnosis of fractures of the tibial plateau. Unfallchirurg 104:519–523CrossRef HacklW Riedl J, Reichkendler M et al (2001) Preoperative computerized tomography diagnosis of fractures of the tibial plateau. Unfallchirurg 104:519–523CrossRef
34.
go back to reference Atesok K, Finkelstein J, Khoury A, Peyser A, Weil Y, Liebergall M, Mosheiff R (2007) The use of intraoperative three-dimensional imaging (ISO-C-3D) in fixation of intraarticular fractures. Injury Int J Care Injured 38:1163–1169CrossRef Atesok K, Finkelstein J, Khoury A, Peyser A, Weil Y, Liebergall M, Mosheiff R (2007) The use of intraoperative three-dimensional imaging (ISO-C-3D) in fixation of intraarticular fractures. Injury Int J Care Injured 38:1163–1169CrossRef
Metadata
Title
Three-column classification and Schatzker classification: a three- and two-dimensional computed tomography characterisation and analysis of tibial plateau fractures
Authors
Sheethal Prasad Patange Subba Rao
James Lewis
Ziad Haddad
Vishal Paringe
Khitish Mohanty
Publication date
01-10-2014
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 7/2014
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-013-1308-9

Other articles of this Issue 7/2014

European Journal of Orthopaedic Surgery & Traumatology 7/2014 Go to the issue