Abstract

Introduction

The 95-degree-fixed angle blade plate has been in use for decades for both acute femoral fractures and nonunions. Our objective was to examine the results of use by a single surgeon of the 95-degree-angled blade plate in proximal and distal femoral nonunion surgery.

Patients and methods

The nonunion database of a single surgeon over a 16 year period was used to identify all proximal and distal femoral nonunions that were treated with open reduction and internal fixation using the 95-degree-angled blade plate. There were 78 cases in which the blade plate was used, and 68 of 78 (87.2 % follow-up rate) were followed to a final outcome, which was defined as complete healing of the nonunion, conversion to arthroplasty, or amputation. Failure was defined as revision surgery for persistence of nonunion, conversion to arthroplasty prior to healing, or amputation. Three patients who failed were lost to follow-up prior to a final outcome.

Results

In the 71 patients who were followed to failure or complete follow-up, the rate of healing with one surgery was 77.5 % (55 of 71). Eight of 16 failures required a second surgery for persistence of nonunion and eventually went on to heal the nonunion. Eleven of the 16 failures were in patients who had a known infected nonunion. When the 21 cases of infected nonunions were excluded, the healing rate for aseptic nonunions with one surgery alone using the 95-degree-angled blade plate was 91.2 % (52 of 57) compared with 47.6 % (10 of 21) in the infected nonunion group (p < 0.0001). Eleven patients who had healed their nonunion underwent all or partial removal of the implant for irritation or prominence.

Conclusion

The 95-degree-angled blade plate is an effective reduction aid and fixation device for aseptic nonunions of the proximal and distal femur with acceptable healing rates with one surgery alone.
Literature
1.
go back to reference Altenberg AR, Shorkey RL (1949) Blade-plate fixation in non-union and in complicated fractures of the supracondylar region of the femur. J Bone Joint Surg Am 31A(2):312–316PubMed Altenberg AR, Shorkey RL (1949) Blade-plate fixation in non-union and in complicated fractures of the supracondylar region of the femur. J Bone Joint Surg Am 31A(2):312–316PubMed
2.
go back to reference Berkes MB, Little MT, Lazaro LE, Cymerman RM, Helfet DL, Lorich DG (2012) Catastrophic failure after open reduction internal fixation of femoral neck fractures with a novel locking plate implant. J Orthop Trauma. doi:10.1097/BOT.0b013e31823b4cd1 PubMed Berkes MB, Little MT, Lazaro LE, Cymerman RM, Helfet DL, Lorich DG (2012) Catastrophic failure after open reduction internal fixation of femoral neck fractures with a novel locking plate implant. J Orthop Trauma. doi:10.​1097/​BOT.​0b013e31823b4cd1​ PubMed
3.
go back to reference Button G, Wolinsky P, Hak D (2004) Failure of less invasive stabilization system plates in the distal femur: a report of four cases. J Orthop Trauma 18(8):565–570PubMedCrossRef Button G, Wolinsky P, Hak D (2004) Failure of less invasive stabilization system plates in the distal femur: a report of four cases. J Orthop Trauma 18(8):565–570PubMedCrossRef
4.
go back to reference Ebraheim NA, Liu J, Hashmi SZ, Sochacki KR, Moral MZ, Hirschfeld AG (2012) High complication rate in locking plate fixation of lower periprosthetic distal femur fractures in patients with total knee arthroplasties. J Arthroplasty 27(5):809–813. doi:10.1016/j.arth.2011.08.007 PubMedCrossRef Ebraheim NA, Liu J, Hashmi SZ, Sochacki KR, Moral MZ, Hirschfeld AG (2012) High complication rate in locking plate fixation of lower periprosthetic distal femur fractures in patients with total knee arthroplasties. J Arthroplasty 27(5):809–813. doi:10.​1016/​j.​arth.​2011.​08.​007 PubMedCrossRef
5.
go back to reference Ehlinger M, Adam P, Arlettaz Y, Moor BK, DiMarco A, Brinkert D, Bonnomet F (2011) Minimally-invasive fixation of distal extra-articular femur fractures with locking plates: limitations and failures. Orthop Traumatol Surg Res 97(6):668–674. doi:10.1016/j.otsr.2011.05.004 PubMedCrossRef Ehlinger M, Adam P, Arlettaz Y, Moor BK, DiMarco A, Brinkert D, Bonnomet F (2011) Minimally-invasive fixation of distal extra-articular femur fractures with locking plates: limitations and failures. Orthop Traumatol Surg Res 97(6):668–674. doi:10.​1016/​j.​otsr.​2011.​05.​004 PubMedCrossRef
6.
go back to reference Forward DP, Doro CJ, O’Toole RV, Kim H, Floyd JC, Sciadini MF (2012) A biomechanical comparison of a locking plate, a nail, and a 95 degrees angled blade plate for fixation of subtrochanteric femoral fractures. J Orthop Trauma 26(6):334–340. doi:10.1097/BOT.0b013e3182254ea3 PubMedCrossRef Forward DP, Doro CJ, O’Toole RV, Kim H, Floyd JC, Sciadini MF (2012) A biomechanical comparison of a locking plate, a nail, and a 95 degrees angled blade plate for fixation of subtrochanteric femoral fractures. J Orthop Trauma 26(6):334–340. doi:10.​1097/​BOT.​0b013e3182254ea3​ PubMedCrossRef
9.
go back to reference Kammerlander C, Gebhard F, Meier C, Lenich A, Linhart W, Clasbrummel B, Blauth M (2011) Standardised cement augmentation of the PFNA using a perforated blade: a new technique and preliminary clinical results. A prospective multicentre trial. Injury 42(12):1484–1490. doi:10.1016/j.injury.2011.07.010 Kammerlander C, Gebhard F, Meier C, Lenich A, Linhart W, Clasbrummel B, Blauth M (2011) Standardised cement augmentation of the PFNA using a perforated blade: a new technique and preliminary clinical results. A prospective multicentre trial. Injury 42(12):1484–1490. doi:10.​1016/​j.​injury.​2011.​07.​010
10.
go back to reference Mast J, Jakob R, Ganz R (1989) Planning and Reduction Technique in Fracture Surgery. Springer, BerlinCrossRef Mast J, Jakob R, Ganz R (1989) Planning and Reduction Technique in Fracture Surgery. Springer, BerlinCrossRef
11.
15.
go back to reference Weresh MJ, Hakanson R, Stover MD, Sims SH, Kellam JF, Bosse MJ (2000) Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures. J Orthop Trauma 14(5):335–338PubMedCrossRef Weresh MJ, Hakanson R, Stover MD, Sims SH, Kellam JF, Bosse MJ (2000) Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures. J Orthop Trauma 14(5):335–338PubMedCrossRef
16.
go back to reference Zickel RE (1988) Nonunions of fractures of the proximal and distal thirds of the shaft of the femur. Instr Course Lect 37:173–179PubMed Zickel RE (1988) Nonunions of fractures of the proximal and distal thirds of the shaft of the femur. Instr Course Lect 37:173–179PubMed
Metadata
Title
The use of the 95-degree-angled blade plate in femoral nonunion surgery
Authors
Louis F. Amorosa
Prem R. Jayaram
David S. Wellman
Dean G. Lorich
David L. Helfet
Publication date
01-08-2014
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 6/2014
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-013-1267-1

Other articles of this Issue 6/2014

European Journal of Orthopaedic Surgery & Traumatology 6/2014 Go to the issue