Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 6/2013

01-08-2013 | Original Article

Use of bone graft substitute in the treatment for distal radius fractures in elderly

Authors: Chintan Hegde, Vishvas Shetty, Sandeep Wasnik, Imthiaz Ahammed, Vijay Shetty

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 6/2013

Login to get access

Abstract

Introduction

Fractures of the distal radius in elderly patients are often associated with metaphyseal defects that can lead to collapse, malunion and therefore decreased function. An alternative approach to simple reduction is to fill the defects with materials that can provide structural support.

Methods

We used synthetic hydroxyapatite (HA) in unstable fractures of the distal radius in thirty-one elderly patients, of which four patients lost to follow-up, leaving twenty-seven patients for this study. All subjects underwent closed reduction with K-wire fixation and HA augmentation. They were followed up at 8- and 16-week intervals post-operatively to assess the functional outcome using patient-related wrist evaluation [PRWE], clinical outcome and radiological outcome.

Results

At mean 16 weeks, our results show that patients treated with this method showed no metaphyseal defect, no collapse and had satisfactory clinical outcome as assessed by PRWE.

Conclusion

We believe that fixation with hydroxyapatite augmentation for fractures of the distal radius in elderly patients is an attractive therapeutic option. This experience has changed our clinical practice.
Literature
1.
go back to reference Solgaard W, Petersen SV (1985) Epidemiology of distal radius fractures. Acta Orthop Scand 56:391–393PubMedCrossRef Solgaard W, Petersen SV (1985) Epidemiology of distal radius fractures. Acta Orthop Scand 56:391–393PubMedCrossRef
2.
go back to reference Dobyns JH, Linscheid RL (2006) Fractures and dislocations of wrist. In: Rockwood CA Jr., Green DP (eds), Fractures in adults, vol 1, 4th edn. Lippincott Williams and Wilkins, p 769–791 Dobyns JH, Linscheid RL (2006) Fractures and dislocations of wrist. In: Rockwood CA Jr., Green DP (eds), Fractures in adults, vol 1, 4th edn. Lippincott Williams and Wilkins, p 769–791
3.
go back to reference Colles A (1972) The classic: on the fracture of the carpal extremity of the radius. Clin Orthop 83:3–5 (Reprinted from the original 1814 article)CrossRef Colles A (1972) The classic: on the fracture of the carpal extremity of the radius. Clin Orthop 83:3–5 (Reprinted from the original 1814 article)CrossRef
4.
go back to reference Sarmiento A, Pratt GW, Berry NC, Sinclair WF (1975) Colles’ fractures. Functional bracing in supination. J Bone Joint Surg Am 57(3):311–317PubMed Sarmiento A, Pratt GW, Berry NC, Sinclair WF (1975) Colles’ fractures. Functional bracing in supination. J Bone Joint Surg Am 57(3):311–317PubMed
5.
go back to reference Jupiter JB (1991) Current concepts review: fractures of the distal end of the radius. J Bone Joint Surg Am 73(3):461–469PubMed Jupiter JB (1991) Current concepts review: fractures of the distal end of the radius. J Bone Joint Surg Am 73(3):461–469PubMed
6.
go back to reference Cooney WP, Linscheid RL, Dobyns JH (1979) External pins fixation for unstable Colles’ fracture. J Bone Joint Surg Am 61:840–845PubMed Cooney WP, Linscheid RL, Dobyns JH (1979) External pins fixation for unstable Colles’ fracture. J Bone Joint Surg Am 61:840–845PubMed
7.
go back to reference Cooney WP III, Dobyns JH, Llnscbeld RL (1975) Complications of Colles’ fractures complications. J Bone Joint Surg Am 57(3):311–317 Cooney WP III, Dobyns JH, Llnscbeld RL (1975) Complications of Colles’ fractures complications. J Bone Joint Surg Am 57(3):311–317
8.
go back to reference Willcox N, Kurta I, Menez D (2005) Treatment of distal radial fractures with grafting and K-wiring. Acta Orthop Belg 71:36–40PubMed Willcox N, Kurta I, Menez D (2005) Treatment of distal radial fractures with grafting and K-wiring. Acta Orthop Belg 71:36–40PubMed
9.
go back to reference Tyllianakis ME, Panagopoulos A, Giannikas D, Megas P, Lambiris E (2006) Graft-supplemented, augmented external fixation in the treatment of intra-articular distal radial fractures. Orthopedics 29(2):139PubMed Tyllianakis ME, Panagopoulos A, Giannikas D, Megas P, Lambiris E (2006) Graft-supplemented, augmented external fixation in the treatment of intra-articular distal radial fractures. Orthopedics 29(2):139PubMed
10.
go back to reference Goulet JA, Senunas LE, DeSilva GL, Greenfield ML (1997) Autogenous iliac crest bone graft: complications and functional assessment. Clin Orthop Relat Res 339:76–81PubMedCrossRef Goulet JA, Senunas LE, DeSilva GL, Greenfield ML (1997) Autogenous iliac crest bone graft: complications and functional assessment. Clin Orthop Relat Res 339:76–81PubMedCrossRef
11.
go back to reference Arrington ED, Smith WJ (1996) Complications of iliac crest bone graft harvesting. Clin Orthop Relat Res 329:300–309PubMedCrossRef Arrington ED, Smith WJ (1996) Complications of iliac crest bone graft harvesting. Clin Orthop Relat Res 329:300–309PubMedCrossRef
12.
go back to reference Wolfe SW, Pike L (1999) Augmentation of distal radius fracture fixation with coralline hydroxyapatite bone graft substitute. J Hand Surg 24:816CrossRef Wolfe SW, Pike L (1999) Augmentation of distal radius fracture fixation with coralline hydroxyapatite bone graft substitute. J Hand Surg 24:816CrossRef
13.
go back to reference Frykman GK (1967) Fracture of the distal radius including sequelae–shoulder–hand–finger syndrome: disturbance in the distal radioulnar joint and impairment of nerve function. Acta Orthop Scand Suppl 108:1–153 Frykman GK (1967) Fracture of the distal radius including sequelae–shoulder–hand–finger syndrome: disturbance in the distal radioulnar joint and impairment of nerve function. Acta Orthop Scand Suppl 108:1–153
14.
go back to reference Changulani M, Okonkwo U (2008) Outcome evaluation measures for wrist and hand—which one to choose? Int Orthop 32(1):1–6PubMedCrossRef Changulani M, Okonkwo U (2008) Outcome evaluation measures for wrist and hand—which one to choose? Int Orthop 32(1):1–6PubMedCrossRef
15.
go back to reference Gajdosik RL, Bohannon RW (1987) Clinical measurement of range of motion: review of goniometry emphasizing reliability and validity. Phys Ther 67(12):1867–1872PubMed Gajdosik RL, Bohannon RW (1987) Clinical measurement of range of motion: review of goniometry emphasizing reliability and validity. Phys Ther 67(12):1867–1872PubMed
16.
go back to reference Ng CY, McQueen MM (2011) What are the radiological predictors of functional outcome following fractures of the distal radius? J Bone Joint Surg Br 93(2):145–150PubMed Ng CY, McQueen MM (2011) What are the radiological predictors of functional outcome following fractures of the distal radius? J Bone Joint Surg Br 93(2):145–150PubMed
17.
go back to reference Dorozhkin SV (2009) Calcium orthophosphate cements and concretes. Materials 2:221–291CrossRef Dorozhkin SV (2009) Calcium orthophosphate cements and concretes. Materials 2:221–291CrossRef
18.
go back to reference Finkemeier CG (2002) Bone-grafting and bone-graft substitutes. J Bone Joint Surg Am 84:454–464PubMed Finkemeier CG (2002) Bone-grafting and bone-graft substitutes. J Bone Joint Surg Am 84:454–464PubMed
19.
go back to reference Brandoff JF (2002) Contemporary options in synthetic bone graft alternatives. J Trauma 53:1103–1108CrossRef Brandoff JF (2002) Contemporary options in synthetic bone graft alternatives. J Trauma 53:1103–1108CrossRef
20.
go back to reference Dickson KF, Friedman J, Buchholz JG, Flandry FD (2002) The use of bone source hydroxyapatite cement for traumatic metaphyseal bone void filling. J Trauma 53:1103–1108PubMedCrossRef Dickson KF, Friedman J, Buchholz JG, Flandry FD (2002) The use of bone source hydroxyapatite cement for traumatic metaphyseal bone void filling. J Trauma 53:1103–1108PubMedCrossRef
21.
go back to reference Sanchez-Sotelo J, Munuera L, Madero R (2000) Treatment of fractures of the distal radius with a remodellable bone cement—a prospective, randomised study using Norian SRS. J Bone Joint Surg Br 82(B):856–863PubMedCrossRef Sanchez-Sotelo J, Munuera L, Madero R (2000) Treatment of fractures of the distal radius with a remodellable bone cement—a prospective, randomised study using Norian SRS. J Bone Joint Surg Br 82(B):856–863PubMedCrossRef
22.
go back to reference Liverneaux P, Vernet P, Robert C, Diacono P (2006) Cement pinning of osteoporotic distal radius fractures with an injectable calcium phosphate bone substitute: report of 6 cases. Eur J Orthop Surg Traumatol 16(1):10–16CrossRef Liverneaux P, Vernet P, Robert C, Diacono P (2006) Cement pinning of osteoporotic distal radius fractures with an injectable calcium phosphate bone substitute: report of 6 cases. Eur J Orthop Surg Traumatol 16(1):10–16CrossRef
23.
go back to reference Liverneaux PA (2006) Osteoporotic distal radius curettage-filling with an injectable calcium phosphate cement. A cadaveric study. Eur J Orthop Surg Traumatol 15(1):1–6CrossRef Liverneaux PA (2006) Osteoporotic distal radius curettage-filling with an injectable calcium phosphate cement. A cadaveric study. Eur J Orthop Surg Traumatol 15(1):1–6CrossRef
Metadata
Title
Use of bone graft substitute in the treatment for distal radius fractures in elderly
Authors
Chintan Hegde
Vishvas Shetty
Sandeep Wasnik
Imthiaz Ahammed
Vijay Shetty
Publication date
01-08-2013
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 6/2013
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-012-1057-1

Other articles of this Issue 6/2013

European Journal of Orthopaedic Surgery & Traumatology 6/2013 Go to the issue