Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 8/2008

01-11-2008 | Original Article

Digital pre-operative templating is more accurate in total hip replacement compared to analogue templating

Authors: M. Hossain, J. Lewis, A. Sinha

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 8/2008

Login to get access

Abstract

We prospectively evaluated the accuracy of digital compared to analogue pre-operative templating in 50 consecutive primary hip replacements between April 2006 and June 2007. The senior author pre-operatively templated implant size using TraumaCad (Orthocrat Limited, Israel). Thirty-one Exeter primary hip and 19 hybrid hip replacements were performed. Hips were templated using radiographs calibrated against a spherical metal ball. For each hip, an AP pelvis view was used. Acetabular implants used were either Trident PSL or Exeter contemporary cup (Stryker). Femoral stem was Exeter (Stryker). Predicted implant sizes were documented. Post-operatively, the predicted implant size was compared to the implanted components. All post-operative films showed good fit of components and there were no intraoperative or post-operative fractures. The intra-rater reliability (ICC) of analogue templating was 0.96 and digital templating was 0.90. Accurate templating score for acetabular cup was 46% (digital) 43% (analogue), femoral offset was 80% (digital) 70% (analogue), femoral stem was 76% (digital) 60% (analogue). The differences between templating and actual implant sizes were plotted in Bland–Altman plot. Digital templating produced narrower confidence interval compared to analogue templating. Digital templating proved to be statistically, significantly more accurate compared to analogue templating for acetabluar cup and femoral stem. Our data indicate that digital templating is more reliable in predicting actual implant sizes for total hip arthroplasty when performed by the operating surgeon.
Literature
1.
go back to reference Bertram T, Diercks RL, van Ooijen PM, Horn JR (2005) Comparison of analog and digital preoperative planning in total and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 76:78CrossRef Bertram T, Diercks RL, van Ooijen PM, Horn JR (2005) Comparison of analog and digital preoperative planning in total and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 76:78CrossRef
2.
go back to reference Della Valle AG, Padgett DE, Salvatti EA (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13:455PubMed Della Valle AG, Padgett DE, Salvatti EA (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13:455PubMed
3.
go back to reference Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Join Surg 80-B:382CrossRef Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Join Surg 80-B:382CrossRef
4.
go back to reference Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51PubMedCrossRef Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51PubMedCrossRef
5.
go back to reference Hossain M, Sinha AK (2007) A technique to avoid leg length discrepancy in total hip replacement. Ann R Coll Surg Engl 89:314PubMedCrossRef Hossain M, Sinha AK (2007) A technique to avoid leg length discrepancy in total hip replacement. Ann R Coll Surg Engl 89:314PubMedCrossRef
6.
go back to reference Knight JL, Atwater RD (1992) Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplasty 7(suppl):403PubMedCrossRef Knight JL, Atwater RD (1992) Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplasty 7(suppl):403PubMedCrossRef
7.
go back to reference Landis RJ, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159PubMedCrossRef Landis RJ, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159PubMedCrossRef
8.
go back to reference Martin J, Marsh JL, Nepola JV et al (2000) Radiographic fracture assessments: which ones can we reliably make? J Orthopedic Trauma 14:379CrossRef Martin J, Marsh JL, Nepola JV et al (2000) Radiographic fracture assessments: which ones can we reliably make? J Orthopedic Trauma 14:379CrossRef
9.
go back to reference Oddy MJ, Jones MJ, Pendegrass CJ (2006) Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg 88-B:581CrossRef Oddy MJ, Jones MJ, Pendegrass CJ (2006) Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg 88-B:581CrossRef
10.
go back to reference Remington RD, Schork MA (1970) Statistics with applications to the biological and health sciences. Prentice-Hall, Englewood Cliffs, p 188 Remington RD, Schork MA (1970) Statistics with applications to the biological and health sciences. Prentice-Hall, Englewood Cliffs, p 188
11.
go back to reference Suh KT, Cheon SJ, Kim DW (2004) Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand 75:40PubMedCrossRef Suh KT, Cheon SJ, Kim DW (2004) Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand 75:40PubMedCrossRef
12.
go back to reference Wimsey S, Pickard R, Shaw G (2006) Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods. J Bone Joint Surg 88:1508CrossRef Wimsey S, Pickard R, Shaw G (2006) Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods. J Bone Joint Surg 88:1508CrossRef
Metadata
Title
Digital pre-operative templating is more accurate in total hip replacement compared to analogue templating
Authors
M. Hossain
J. Lewis
A. Sinha
Publication date
01-11-2008
Publisher
Springer-Verlag
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 8/2008
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-008-0356-z

Other articles of this Issue 8/2008

European Journal of Orthopaedic Surgery & Traumatology 8/2008 Go to the issue