Skip to main content
Top
Published in: European Spine Journal 7/2015

01-07-2015 | Original Article

Medially misplaced pedicle screws in patients without neurological deficits following scoliosis surgery: to observe or to remove?

Authors: Ryo Sugawara, Taichi Tsuji, Toshiki Saito, Ayato Nohara, Kazuki Kawakami, Norikaki Kawakami

Published in: European Spine Journal | Issue 7/2015

Login to get access

Abstract

Purpose

This study investigated whether pedicle screws medially misplaced into the spinal canal without neurological complications should be removed or not.

Methods

A total of 86 patients with scoliosis that underwent spinal fusion using 988 pedicle screws were retrospectively reviewed after a minimum follow-up of 2 years. The inclusion criteria were: (1) patients without outstanding problems during the insertion of pedicle screws, (2) patients without neurological deficits either intraoperatively or postoperatively, and (3) patients that had all implants removed after bone union upon the request of the patient. Medial perforations were evaluated using immediate postoperative helical CT images and classified into three grades: grade 1 (0–2 mm), grade 2 (2–4 mm), and grade 3 (over 4 mm). All unexpected events were recorded at the time of removal.

Results

CT images obtained 2 years postoperatively exhibited neither loosening of screws nor pseudoarthrosis in all patients. CSF leakage from screw holes were recognized in 3 of 87 medially misplaced screws (3.4 %). There was no CSF leakage in grade 1 (35 screws), one CSF leakage (2.5 %) in grade 2 (40 screws), and two (16.7 %) in grade 3 (12 screws). No neurological abnormalities occurred either intraoperatively or postoperatively.

Conclusion

This study indicated that screws medially misplaced at a distance greater than 2 mm, especially 4 mm, may be a cause of negative effects on the neural structure and should be removed during the early phase of the postoperative period, even among patients without postoperative neurological abnormalities.
Literature
1.
go back to reference Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M (1999) Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 8:156–160PubMedCentralPubMedCrossRef Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M (1999) Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 8:156–160PubMedCentralPubMedCrossRef
2.
go back to reference Suk SI, Kim WJ, Lee SM, Kim JH, Chung ER (2001) Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine 26:2049–2057PubMedCrossRef Suk SI, Kim WJ, Lee SM, Kim JH, Chung ER (2001) Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine 26:2049–2057PubMedCrossRef
3.
go back to reference Albayram S, Ulu MO, Hanimoglu H, Kaynar MY, Hanci M (2008) Intracranial hypotension following scoliosis surgery: dural penetration of a thoracic pedicle screw. Eur Spine J 17(Suppl 2):S347–S350PubMedCrossRef Albayram S, Ulu MO, Hanimoglu H, Kaynar MY, Hanci M (2008) Intracranial hypotension following scoliosis surgery: dural penetration of a thoracic pedicle screw. Eur Spine J 17(Suppl 2):S347–S350PubMedCrossRef
4.
go back to reference Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew D (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342PubMedCrossRef Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew D (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342PubMedCrossRef
5.
go back to reference Choi JB, Han JO, Jeong JW (2001) False aneurysm of the thoracic aorta associated with an aorto-chest wall fistula after spinal instrumentation. J Trauma 50:140–143PubMedCrossRef Choi JB, Han JO, Jeong JW (2001) False aneurysm of the thoracic aorta associated with an aorto-chest wall fistula after spinal instrumentation. J Trauma 50:140–143PubMedCrossRef
6.
go back to reference Wegener B, Birkenmaier C, Fottner A, Jansson V, Durr HR (2008) Delayed perforation of the aorta by a thoracic pedicle screw. Eur Spine J 17(Suppl 2):S351–S354PubMedCrossRef Wegener B, Birkenmaier C, Fottner A, Jansson V, Durr HR (2008) Delayed perforation of the aorta by a thoracic pedicle screw. Eur Spine J 17(Suppl 2):S351–S354PubMedCrossRef
7.
go back to reference Mac-Thiong JM, Parent S, Poitras B, Joncas J, Hubert L (2013) Neurological outcome and management of pedicle screws misplaced totally within the spinal canal. Spine 38:229–237PubMedCrossRef Mac-Thiong JM, Parent S, Poitras B, Joncas J, Hubert L (2013) Neurological outcome and management of pedicle screws misplaced totally within the spinal canal. Spine 38:229–237PubMedCrossRef
8.
go back to reference Reidy DP, Houlden D, Nolan PC, Kim M, Finkelstein JA (2001) Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws. J Bone Joint Surg Am 83:1009–1014CrossRef Reidy DP, Houlden D, Nolan PC, Kim M, Finkelstein JA (2001) Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws. J Bone Joint Surg Am 83:1009–1014CrossRef
9.
go back to reference Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM (1995) Placement of pedicle screws in the thoracic spine. I: Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM (1995) Placement of pedicle screws in the thoracic spine. I: Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed
10.
11.
go back to reference Liljenqvist U, Lepsien U, Hackenberg L, Niemeyer T, Halm H (2002) Comparative analysis of pedicle screw and hook instrumentation in posterior correction and fusion of idiopathic thoracic scoliosis. Eur Spine J 11:336–343PubMedCentralPubMedCrossRef Liljenqvist U, Lepsien U, Hackenberg L, Niemeyer T, Halm H (2002) Comparative analysis of pedicle screw and hook instrumentation in posterior correction and fusion of idiopathic thoracic scoliosis. Eur Spine J 11:336–343PubMedCentralPubMedCrossRef
12.
go back to reference Liljenqvist UR, Allkemper T, Hackenberg L, Link TM, Steinbeck J, Harm HF (2002) Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstruction. J Bone Joint Surg Am 84:359–368PubMed Liljenqvist UR, Allkemper T, Hackenberg L, Link TM, Steinbeck J, Harm HF (2002) Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstruction. J Bone Joint Surg Am 84:359–368PubMed
13.
go back to reference Di Silvestre M, Parisini P, Lolli F, Bakaloudis G (2007) Complications of thoracic pedicle screws in scoliosis treatment. Spine 32:1655–1661PubMedCrossRef Di Silvestre M, Parisini P, Lolli F, Bakaloudis G (2007) Complications of thoracic pedicle screws in scoliosis treatment. Spine 32:1655–1661PubMedCrossRef
14.
go back to reference Wang JC, Bohlman HH, Riew KD (1998) Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am 80:1728–1732PubMedCrossRef Wang JC, Bohlman HH, Riew KD (1998) Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am 80:1728–1732PubMedCrossRef
Metadata
Title
Medially misplaced pedicle screws in patients without neurological deficits following scoliosis surgery: to observe or to remove?
Authors
Ryo Sugawara
Taichi Tsuji
Toshiki Saito
Ayato Nohara
Kazuki Kawakami
Norikaki Kawakami
Publication date
01-07-2015
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 7/2015
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-015-3860-y

Other articles of this Issue 7/2015

European Spine Journal 7/2015 Go to the issue