Skip to main content
Top
Published in: European Spine Journal 2/2013

01-02-2013 | Chinese section

C1–2 transarticular screws combined with C1 laminar hooks fixation: a modified posterior atlantoaxial fixation technique and outcome in 72 patients

Authors: Bin Ni, Xiang Guo, Ning Xie, Songkai Li, Fengjing Zhou, Feng Zhang, Qi Liu

Published in: European Spine Journal | Issue 2/2013

Login to get access

Abstract

Purpose

To retrospectively evaluate the outcome of C1–2 transarticular screws combined with C1 laminar hooks fixation.

Methods

All patients underwent atlantoaxial fixation during a 5-year period. The surgical technique and treatment procedures were intensively reviewed and clinical symptoms, neurological function and imaging appearance were retrospectively evaluated.

Results

The clinical and radiology follow-up indicated a stable arthrodesis and clinical relief from symptoms for all patients. All patients with neurological defects improved an average of 1.33 grade at their most recent clinical assessment, P < 0.05; their average admission ASIA motor score, pin prick score and light touch score improved to an average follow-up ASIA score of 99.80 (99.83 ± 0.38), 111.83 (111.83 ± 0.45), and 111.89 (111.89 ± 0.32), respectively. No neurovascular impairment and case of implant failure were observed.

Conclusions

The C1–2 transarticular screws combined with C1 laminar hooks fixation is a reliable technique for atlantoaxial instability.
Literature
1.
go back to reference Brooks AL, Jenkins EB (1978) Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 60(3):279–284PubMed Brooks AL, Jenkins EB (1978) Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 60(3):279–284PubMed
2.
go back to reference Fassett DR, Harrop JS, Maltenfort M, Jeyamohan SB, Ratliff JD, Anderson DG, Hilibrand AS, Albert TJ, Vaccaro AR, Sharan AD (2007) Mortality rates in geriatric patients with spinal cord injuries. J Neurosurg Spine 7(3):277–281. doi:10.3171/SPI-07/09/277 PubMedCrossRef Fassett DR, Harrop JS, Maltenfort M, Jeyamohan SB, Ratliff JD, Anderson DG, Hilibrand AS, Albert TJ, Vaccaro AR, Sharan AD (2007) Mortality rates in geriatric patients with spinal cord injuries. J Neurosurg Spine 7(3):277–281. doi:10.​3171/​SPI-07/​09/​277 PubMedCrossRef
3.
go back to reference Henriques T, Cunningham BW, Olerud C, Shimamoto N, Lee GA, Larsson S, McAfee PA (2000) Biomechanical comparison of five different atlantoaxial posterior fixation techniques. Spine (Phila Pa 1976) 25 (22):2877–2883 Henriques T, Cunningham BW, Olerud C, Shimamoto N, Lee GA, Larsson S, McAfee PA (2000) Biomechanical comparison of five different atlantoaxial posterior fixation techniques. Spine (Phila Pa 1976) 25 (22):2877–2883
4.
go back to reference Dickman CA, Sonntag VK (1998) Posterior C1–C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery 43(2):275–280 (discussion 280–271)PubMedCrossRef Dickman CA, Sonntag VK (1998) Posterior C1–C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery 43(2):275–280 (discussion 280–271)PubMedCrossRef
5.
go back to reference Gerbier G, Williams WT, Price PB, Guoxiao R, Vanderhaeghe G (1987) Charges and angular distributions of fast fragments produced in 3.2-TeV 16O collisions with Pb. Phys Rev Lett 59(22):2535–2538PubMedCrossRef Gerbier G, Williams WT, Price PB, Guoxiao R, Vanderhaeghe G (1987) Charges and angular distributions of fast fragments produced in 3.2-TeV 16O collisions with Pb. Phys Rev Lett 59(22):2535–2538PubMedCrossRef
6.
go back to reference Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86(6):961–968PubMedCrossRef Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86(6):961–968PubMedCrossRef
7.
go back to reference Paramore CG, Dickman CA, Sonntag VK (1996) The anatomical suitability of the C1–2 complex for transarticular screw fixation. J Neurosurg 85(2):221–224PubMedCrossRef Paramore CG, Dickman CA, Sonntag VK (1996) The anatomical suitability of the C1–2 complex for transarticular screw fixation. J Neurosurg 85(2):221–224PubMedCrossRef
9.
go back to reference Grob D, Crisco JJ 3rd, Panjabi MM, Wang P, Dvorak J (1992) Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine (Phila Pa 1976) 17(5):480–490 Grob D, Crisco JJ 3rd, Panjabi MM, Wang P, Dvorak J (1992) Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine (Phila Pa 1976) 17(5):480–490
10.
go back to reference Lapsiwala SB, Anderson PA, Oza A, Resnick DK (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58(3):516–521 (discussion 516–521). doi:10.1227/01.NEU.0000197222.05299.31 Lapsiwala SB, Anderson PA, Oza A, Resnick DK (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58(3):516–521 (discussion 516–521). doi:10.​1227/​01.​NEU.​0000197222.​05299.​31
12.
go back to reference Smith MD, Kotzar G, Yoo J, Bohlman H (1993) A biomechanical analysis of atlantoaxial stabilization methods using a bovine model. C1/C2 fixation analysis. Clin Orthop Relat Res 290:285–295PubMed Smith MD, Kotzar G, Yoo J, Bohlman H (1993) A biomechanical analysis of atlantoaxial stabilization methods using a bovine model. C1/C2 fixation analysis. Clin Orthop Relat Res 290:285–295PubMed
13.
14.
go back to reference Heuer GG, Hardesty DA, Bhowmick DA, Bailey R, Magge SN, Storm PB (2009) Treatment of pediatric atlantoaxial instability with traditional and modified Goel-Harms fusion constructs. Eur Spine J 18(6):884–892. doi:10.1007/s00586-009-0969-x PubMedCrossRef Heuer GG, Hardesty DA, Bhowmick DA, Bailey R, Magge SN, Storm PB (2009) Treatment of pediatric atlantoaxial instability with traditional and modified Goel-Harms fusion constructs. Eur Spine J 18(6):884–892. doi:10.​1007/​s00586-009-0969-x PubMedCrossRef
15.
go back to reference Cornefjord M, Henriques T, Alemany M, Olerud C (2003) Posterior atlanto-axial fusion with the Olerud Cervical Fixation System for odontoid fractures and C1–C2 instability in rheumatoid arthritis. Eur Spine J 12(1):91–96. doi:10.1007/s00586-002-0470-2 PubMed Cornefjord M, Henriques T, Alemany M, Olerud C (2003) Posterior atlanto-axial fusion with the Olerud Cervical Fixation System for odontoid fractures and C1–C2 instability in rheumatoid arthritis. Eur Spine J 12(1):91–96. doi:10.​1007/​s00586-002-0470-2 PubMed
16.
go back to reference Anderson RC, Kan P, Gluf WM, Brockmeyer DL (2006) Long-term maintenance of cervical alignment after occipitocervical and atlantoaxial screw fixation in young children. J Neurosurg 105(1 Suppl):55–61. doi:10.3171/ped.2006.105.1.55 PubMed Anderson RC, Kan P, Gluf WM, Brockmeyer DL (2006) Long-term maintenance of cervical alignment after occipitocervical and atlantoaxial screw fixation in young children. J Neurosurg 105(1 Suppl):55–61. doi:10.​3171/​ped.​2006.​105.​1.​55 PubMed
17.
go back to reference Anderson RC, Ragel BT, Mocco J, Bohman LE, Brockmeyer DL (2007) Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients. J Neurosurg 107(1 Suppl):36–42. doi:10.3171/PED-07/07/036 PubMed Anderson RC, Ragel BT, Mocco J, Bohman LE, Brockmeyer DL (2007) Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients. J Neurosurg 107(1 Suppl):36–42. doi:10.​3171/​PED-07/​07/​036 PubMed
18.
go back to reference Brockmeyer DL, York JE, Apfelbaum RI (2000) Anatomical suitability of C1–2 transarticular screw placement in pediatric patients. J Neurosurg 92(1 Suppl):7–11PubMed Brockmeyer DL, York JE, Apfelbaum RI (2000) Anatomical suitability of C1–2 transarticular screw placement in pediatric patients. J Neurosurg 92(1 Suppl):7–11PubMed
19.
go back to reference Gluf WM, Schmidt MH, Apfelbaum RI (2005) Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients. J Neurosurg Spine 2(2):155–163PubMedCrossRef Gluf WM, Schmidt MH, Apfelbaum RI (2005) Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients. J Neurosurg Spine 2(2):155–163PubMedCrossRef
20.
go back to reference Suchomel P, Stulik J, Klezl Z, Chrobok J, Lukas R, Krbec M, Magerl F (2004) Transarticular fixation of C1–C2: a multicenter retrospective study. Acta Chir Orthop Traumatol Cech 71(1):6–12PubMed Suchomel P, Stulik J, Klezl Z, Chrobok J, Lukas R, Krbec M, Magerl F (2004) Transarticular fixation of C1–C2: a multicenter retrospective study. Acta Chir Orthop Traumatol Cech 71(1):6–12PubMed
21.
go back to reference Kandziora F, Kerschbaumer F, Starker M, Mittlmeier T (2000) Biomechanical assessment of transoral plate fixation for atlantoaxial instability. Spine (Phila Pa 1976) 25 (12):1555–1561 Kandziora F, Kerschbaumer F, Starker M, Mittlmeier T (2000) Biomechanical assessment of transoral plate fixation for atlantoaxial instability. Spine (Phila Pa 1976) 25 (12):1555–1561
22.
go back to reference Farey ID, Nadkarni S, Smith N (1999) Modified Gallie technique versus transarticular screw fixation in C1–C2 fusion. Clin Orthop Relat Res 359:126–135PubMedCrossRef Farey ID, Nadkarni S, Smith N (1999) Modified Gallie technique versus transarticular screw fixation in C1–C2 fusion. Clin Orthop Relat Res 359:126–135PubMedCrossRef
23.
go back to reference Goel A, Gupta S (1999) Vertebral artery injury with transarticular screws. J Neurosurg 90(2):376–377PubMed Goel A, Gupta S (1999) Vertebral artery injury with transarticular screws. J Neurosurg 90(2):376–377PubMed
24.
go back to reference Abou Madawi A, Solanki G, Casey AT, Crockard HA (1997) Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation. J Bone Joint Surg Br 79 (5):820–823 Abou Madawi A, Solanki G, Casey AT, Crockard HA (1997) Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation. J Bone Joint Surg Br 79 (5):820–823
25.
go back to reference Bloch O, Holly LT, Park J, Obasi C, Kim K, Johnson JP (2001) Effect of frameless stereotaxy on the accuracy of C1–2 transarticular screw placement. J Neurosurg 95(1 Suppl):74–79PubMed Bloch O, Holly LT, Park J, Obasi C, Kim K, Johnson JP (2001) Effect of frameless stereotaxy on the accuracy of C1–2 transarticular screw placement. J Neurosurg 95(1 Suppl):74–79PubMed
Metadata
Title
C1–2 transarticular screws combined with C1 laminar hooks fixation: a modified posterior atlantoaxial fixation technique and outcome in 72 patients
Authors
Bin Ni
Xiang Guo
Ning Xie
Songkai Li
Fengjing Zhou
Feng Zhang
Qi Liu
Publication date
01-02-2013
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 2/2013
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-012-2397-6

Other articles of this Issue 2/2013

European Spine Journal 2/2013 Go to the issue