Skip to main content
Top
Published in: European Spine Journal 5/2012

01-05-2012 | Original Article

Improving successful rate of transcranial electrical motor-evoked potentials monitoring during spinal surgery in young children

Authors: Junlin Yang, Zifang Huang, Haihua Shu, Yuguang Chen, Xinrui Sun, Weifeng Liu, Yunling Dou, Chaofan Xie, Xiang Lin, Yong Hu

Published in: European Spine Journal | Issue 5/2012

Login to get access

Abstract

Introduction

This prospective study was to investigate the successful rate of intraoperative motor evoked potentials (MEP) monitoring for children (<12 years old) with congenital scoliosis.

Materials and methods

A consecutive series of 27 young children (7 girls and 20 boys; from 1 to 11 years old) between September 2007 and November 2009, were enrolled to this study. 12 patients received general anesthesia based on TIVA, induced with propofol 2–4 mg/kg and fentanyl 3–5 µg/kg followed by a continuous infusion of propofol (20–150 µg/kg/min, at mean of 71.7 µg/kg/min). The other 15 patients received combined inhalation and intravenous anesthesia, induced with sevoflurane and fentanyl 3–5 µg/kg and maintained by sevoflurane (0.5–1%). The maintenance of anaesthesia management was performed with stable physiological parameters during surgery.

Results

Intraoperative MEP monitoring was successfully performed in all patients, while SEP was successfully performed in 26 of 27 patients. There was no significant difference of successful rates between SEP and MEP monitoring (P > 0.05). As well, no difference in MEP successful rates was observed in two groups with different anesthetic techniques. No wake-up test and no post-operative neurological deficits occurred in this series of patients.

Conclusion

Low dose anesthesia by either TIVA with propofol or sevoflurane-based mixture anesthesia protocol can help the intraoperative spinal cord monitoring to successfully elicit MEP and perform reliable monitoring for patients below 12 years of age.
Literature
1.
go back to reference Dawson EG, Sherman JE, Kanim LE et al (1991) Spinal cord monitoring. Results of the Scoliosis Research Society and the European Spinal Deformity Society survey. Spine 16:S361–S364PubMedCrossRef Dawson EG, Sherman JE, Kanim LE et al (1991) Spinal cord monitoring. Results of the Scoliosis Research Society and the European Spinal Deformity Society survey. Spine 16:S361–S364PubMedCrossRef
2.
go back to reference Devlin V (2003) Intraoperative spinal monitoring. In: Spine secrets. Hanley & Belfus Inc., Philadelphia, pp 232–242. Devlin V (2003) Intraoperative spinal monitoring. In: Spine secrets. Hanley & Belfus Inc., Philadelphia, pp 232–242.
3.
go back to reference Nuwer MR, Dawson EG, Carlson LG et al (1995) Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 96:6–11PubMedCrossRef Nuwer MR, Dawson EG, Carlson LG et al (1995) Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 96:6–11PubMedCrossRef
4.
go back to reference Lo YL, Dan YF, Tan YE et al (2005) A prospective study of the utility of preoperative somatosensory evoked potentials in spinal surgery. Eur Spine J 14:521–522PubMedCrossRef Lo YL, Dan YF, Tan YE et al (2005) A prospective study of the utility of preoperative somatosensory evoked potentials in spinal surgery. Eur Spine J 14:521–522PubMedCrossRef
5.
go back to reference Gonzalez AA, Jeyanandarajan D, Hansen C et al (2009) Intraoperative neurophysiological monitoring during spine surgery: a review. Neurosurg Focus 27(4):E6PubMedCrossRef Gonzalez AA, Jeyanandarajan D, Hansen C et al (2009) Intraoperative neurophysiological monitoring during spine surgery: a review. Neurosurg Focus 27(4):E6PubMedCrossRef
6.
go back to reference Calancie B, Harris W, Brindle GF et al (2001) Threshold-level repetitive transcranial electrical stimulation for intraoperative monitoring of central motor conduction. J Neurosurg Spine 95:161–168CrossRef Calancie B, Harris W, Brindle GF et al (2001) Threshold-level repetitive transcranial electrical stimulation for intraoperative monitoring of central motor conduction. J Neurosurg Spine 95:161–168CrossRef
7.
go back to reference Kombos T, Kopetsch O, Suess O et al (2003) Does preoperative paresis influence intraoperative monitoring of the motor cortex? J Clin Neurophysiol 20:129–134PubMedCrossRef Kombos T, Kopetsch O, Suess O et al (2003) Does preoperative paresis influence intraoperative monitoring of the motor cortex? J Clin Neurophysiol 20:129–134PubMedCrossRef
8.
go back to reference Kombos T, Suess O, Ciklatekerlio O et al (2001) Monitoring of intraoperative motor evoked potentials to increase the safety of surgery in and around the motor cortex. J Neurosurg 95:608–614PubMedCrossRef Kombos T, Suess O, Ciklatekerlio O et al (2001) Monitoring of intraoperative motor evoked potentials to increase the safety of surgery in and around the motor cortex. J Neurosurg 95:608–614PubMedCrossRef
9.
go back to reference Pechstein U, Cedzich C, Nadstawek J et al (1996) Transcranial high-frequency repetitive electrical stimulation for recording myogenic motor evoked potentials with the patient under general anesthesia. Neurosurgery 39:335–343 Pechstein U, Cedzich C, Nadstawek J et al (1996) Transcranial high-frequency repetitive electrical stimulation for recording myogenic motor evoked potentials with the patient under general anesthesia. Neurosurgery 39:335–343
10.
go back to reference Pelosi L, Stevenson M, Hobbs GJ et al (2001) Intraoperative motor evoked potentials to transcranial electrical stimulation during two anaesthetic regimens. Clin Neurophysiol 112:1076–1087PubMedCrossRef Pelosi L, Stevenson M, Hobbs GJ et al (2001) Intraoperative motor evoked potentials to transcranial electrical stimulation during two anaesthetic regimens. Clin Neurophysiol 112:1076–1087PubMedCrossRef
11.
go back to reference Scheufler KM, Reinacher PC, Blumrich W et al (2005) The modifying effects of stimulation pattern and propofol plasma concentration on motor-evoked potentials. Anesth Analg 100:440–447PubMedCrossRef Scheufler KM, Reinacher PC, Blumrich W et al (2005) The modifying effects of stimulation pattern and propofol plasma concentration on motor-evoked potentials. Anesth Analg 100:440–447PubMedCrossRef
12.
go back to reference Zhou HH, Kelly PJ (2001) Transcranial electrical motor evoked potential monitoring for brain tumor resection. Neurosurgery 48:1075–1080PubMedCrossRef Zhou HH, Kelly PJ (2001) Transcranial electrical motor evoked potential monitoring for brain tumor resection. Neurosurgery 48:1075–1080PubMedCrossRef
13.
go back to reference Chen X, Sterio D, Ming X et al (2007) Success rate of motor evoked potentials for intraoperative neurophysiologic monitoring: effects of age, lesion location, and preoperative neurologic deficits. J Clin Neurophysiol 24(3):281–285PubMedCrossRef Chen X, Sterio D, Ming X et al (2007) Success rate of motor evoked potentials for intraoperative neurophysiologic monitoring: effects of age, lesion location, and preoperative neurologic deficits. J Clin Neurophysiol 24(3):281–285PubMedCrossRef
14.
go back to reference Frei FJ, Ryhult SE, Duitmann E et al (2007) Intraoperative monitoring of motor-evoked potentials in children undergoing spinal surgery. Spine 32(8):911–917PubMedCrossRef Frei FJ, Ryhult SE, Duitmann E et al (2007) Intraoperative monitoring of motor-evoked potentials in children undergoing spinal surgery. Spine 32(8):911–917PubMedCrossRef
15.
go back to reference Vitale MG, Moore DW, Matsumoto H et al (2010) Risk factors for spinal cord injury during surgery for spinal deformity. J Bone Joint Surg Am 92(1):64–71PubMedCrossRef Vitale MG, Moore DW, Matsumoto H et al (2010) Risk factors for spinal cord injury during surgery for spinal deformity. J Bone Joint Surg Am 92(1):64–71PubMedCrossRef
16.
go back to reference Coe JD, Arlet V, Donaldson W et al (2006) Complications in spinal fusion for adolescent idiopathic scoliosis in the new millennium. A report of the Scoliosis Research Society Morbidity and Mortality Committee. Spine 31:345–349PubMedCrossRef Coe JD, Arlet V, Donaldson W et al (2006) Complications in spinal fusion for adolescent idiopathic scoliosis in the new millennium. A report of the Scoliosis Research Society Morbidity and Mortality Committee. Spine 31:345–349PubMedCrossRef
17.
go back to reference Skaggs DL, Choi PD, Rice C et al (2009) Efficacy of intraoperative neurologic monitoring in surgery involving a vertical expandable prosthetic titanium rib for early-onset spinal deformity. J Bone Joint Surg Am 91:1657–1663PubMedCrossRef Skaggs DL, Choi PD, Rice C et al (2009) Efficacy of intraoperative neurologic monitoring in surgery involving a vertical expandable prosthetic titanium rib for early-onset spinal deformity. J Bone Joint Surg Am 91:1657–1663PubMedCrossRef
18.
go back to reference Boor R, Li L, Goebel B et al (2008) Subcortical somatosensory evoked potentials after posterior tibial nerve stimulation in children. Brain Dev 30:493–498PubMedCrossRef Boor R, Li L, Goebel B et al (2008) Subcortical somatosensory evoked potentials after posterior tibial nerve stimulation in children. Brain Dev 30:493–498PubMedCrossRef
19.
go back to reference Journee HL, Polak HE, De Kleuver M (2007) Conditioning stimulation techniques for enhancement of transcranially elicited evoked motor responses. Neurophysiol Clin 37:423–430PubMedCrossRef Journee HL, Polak HE, De Kleuver M (2007) Conditioning stimulation techniques for enhancement of transcranially elicited evoked motor responses. Neurophysiol Clin 37:423–430PubMedCrossRef
20.
go back to reference Kalkman CJ, Drummond JC, Ribberink AA (1991) Low concentrations of isoflurane abolish motor evoked responses to transcranial electrical stimulation during nitrous oxide/opioid anesthesia in humans. Anesth Analg 73:410–415PubMedCrossRef Kalkman CJ, Drummond JC, Ribberink AA (1991) Low concentrations of isoflurane abolish motor evoked responses to transcranial electrical stimulation during nitrous oxide/opioid anesthesia in humans. Anesth Analg 73:410–415PubMedCrossRef
21.
go back to reference Magit DP, Hilibrand AS, Kirk J et al (2007) Questionnaire study of neuromonitoring availability and usage for spine surgery. J Spinal Disord Tech 20:282–289PubMedCrossRef Magit DP, Hilibrand AS, Kirk J et al (2007) Questionnaire study of neuromonitoring availability and usage for spine surgery. J Spinal Disord Tech 20:282–289PubMedCrossRef
22.
go back to reference Sloan TB, Janik D, Jameson L (2008) Multimodality monitoring of the central nervous system using motor-evoked potentials. Curr Opin Anaesthesiol 21:560–564PubMedCrossRef Sloan TB, Janik D, Jameson L (2008) Multimodality monitoring of the central nervous system using motor-evoked potentials. Curr Opin Anaesthesiol 21:560–564PubMedCrossRef
23.
go back to reference Kawaguchi M, Sakamoto T, Inoue S et al (2000) Low dose propofol as a supplement to ketamine-based anesthesia during intraoperative monitoring of motor-evoked potentials. Spine 25:974–979PubMedCrossRef Kawaguchi M, Sakamoto T, Inoue S et al (2000) Low dose propofol as a supplement to ketamine-based anesthesia during intraoperative monitoring of motor-evoked potentials. Spine 25:974–979PubMedCrossRef
24.
go back to reference Davidson AJ (2007) Monitoring the anaesthetic depth in children—an update. Curr Opin Anaesthesiol 20(3):236–243PubMedCrossRef Davidson AJ (2007) Monitoring the anaesthetic depth in children—an update. Curr Opin Anaesthesiol 20(3):236–243PubMedCrossRef
25.
go back to reference Weber F, Hollnberger H, Weber J (2008) Electroencephalographic Narcotrend Index monitoring during procedural sedation and analgesia in children. Paediatr Anaesth 18(9):823–830PubMedCrossRef Weber F, Hollnberger H, Weber J (2008) Electroencephalographic Narcotrend Index monitoring during procedural sedation and analgesia in children. Paediatr Anaesth 18(9):823–830PubMedCrossRef
26.
go back to reference Schultz B, Grouven U, Schultz A (2002) Automatic classification algorithms of the EEG monitor Narcotrend for routinely recorded EEG data from general anesthesia: a validation study. Biomed Tech (Berl) 47:9–13CrossRef Schultz B, Grouven U, Schultz A (2002) Automatic classification algorithms of the EEG monitor Narcotrend for routinely recorded EEG data from general anesthesia: a validation study. Biomed Tech (Berl) 47:9–13CrossRef
27.
go back to reference Felmet K, Nguyen T, Clark RS et al (2003) The FDA warning against prolonged sedation with propofol in children remains warranted. Pediatrics 112(4):1002–1003PubMedCrossRef Felmet K, Nguyen T, Clark RS et al (2003) The FDA warning against prolonged sedation with propofol in children remains warranted. Pediatrics 112(4):1002–1003PubMedCrossRef
28.
go back to reference Lyon R, Feiner J, Lieberman JA (2005) Progressive suppression of motor evoked potentials during general anesthesia: the phenomenon of “anesthetic fade”. J Neurosurg Anesthesiol 17:13–19PubMed Lyon R, Feiner J, Lieberman JA (2005) Progressive suppression of motor evoked potentials during general anesthesia: the phenomenon of “anesthetic fade”. J Neurosurg Anesthesiol 17:13–19PubMed
Metadata
Title
Improving successful rate of transcranial electrical motor-evoked potentials monitoring during spinal surgery in young children
Authors
Junlin Yang
Zifang Huang
Haihua Shu
Yuguang Chen
Xinrui Sun
Weifeng Liu
Yunling Dou
Chaofan Xie
Xiang Lin
Yong Hu
Publication date
01-05-2012
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 5/2012
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-1995-z

Other articles of this Issue 5/2012

European Spine Journal 5/2012 Go to the issue